CHARACTERISTICS : SPECIFICATION :
Eleven field-selectable output modes
Operating voltage AC/DC(V): 12~48 or 100~240
accommodate a wide variety of applications
Allowable operating
85~110% of rated operating voltage
7-segment-display for clear display and voltage range
effective monitoring Rated frequency 50 / 60 Hz
All parameters set by scrollthrough menus Contact rating 250VAC 5A (resistive load)
accessed from the front panel
Reset time MAX 0.1s
Field-selectable time ranges from 0.001
second to 9999 hours Reset time Approx. 2.5VA
Mechanical: 5,000,000 times
Precision control possible to 0.001 second Life
Electrical: 100,000 times
Four levels of key protection provided Ambient temperature -10 ~ +50к
Count Up or Count Down mode user selectable Ambient humidity MAX 85%RH
Memory function available Weight Approx. 120g
UL, C-UL recognized and CE certified
TYPE SELECTION :
RESET
START
4 8 K/P 4 8
2 7 2 7 3 9 3 9
1 8 1 8 2 10 Common (0V) 2 10
1 11 1 11
TIMING CHART :
Output mode A : Signal ON delay 1 (Timer resets when power comes ON.)
SOURCE Timing starts when the start signal goes ON.
Start signal
While the start signal is ON, the timer starts
Gate
when the power comes ON or when the reset
Reset
t t input goes OFF.
Control output
Set value The control output is controlled using a
UP
0 sustained or one-shot time period.
Set value
DOWN
0
Output mode A-1 : Signal ON delay 2 (Timer resets when power comes ON.)
SOURCE Timing starts when the start signal goes ON,
Start signal
and is reset when the start signal goes OFF.
Gate
While the start signal is ON, the timer starts
Reset
t when the power comes ON or when the reset
Control output input goes OFF.
Set value
UP
0 The control output is controlled using a
Set value
DOWN sustained or one-shot time period.
0
Output mode A-2 : Power ON delay 1 (Timer resets when power comes ON.)
SOURCE Timing starts when the reset input goes OFF.
Start signal
The start signal disables the timing function (
Gate
ie., same function as the gate input).
Reset
t
Control output The control output is controlled using a
Set value sustained or one-shot time period.
UP
0
Set value
DOWN
0
Output mode A-3 : Power ON delay 2 (Timer dose not reset when power comes ON.)
SOURCE Timing starts when the reset input goes OFF.
Start signal
The start signal disables the timing function (
Gate
ie., same function as the gate input).
Reset
t t a t-a
Control output The control output is controlled using a
Set value sustained or one-shot time period.
UP
0
Set value
DOWN
0
Output mode B : Repeat cycle 1 (Timer resets when power comes ON.)
SOURCE Timing starts when the start signal goes ON.
Start signal
The status of the control output is reversed
Gate
when time is up (OFF at start).
Reset
Control output While the start signal is ON, the timer starts
Set value when the power comes ON or when the reset
UP
0 input goes OFF.
Set value
DOWN
0
Output mode B-1 : Repeat cycle 2 (Timer dose not reset when power comes ON.)
SOURCE Timing starts when the start signal goes ON.
Start signal
The status of the control output is reversed
Gate
when time is up (OFF at start).
Reset
Control output While the start signal is ON, the timer starts
Set value when the power comes ON or when the reset
UP
0 input goes OFF.
Set value
DOWN
0
Output mode B-2 : Repeat cycle ON start (Timer resets when power comes ON.)
SOURCE Timing starts when the start signal goes ON.
Start signal
The status of the control output is reversed
Reset
when time is up (OFF at start).
Control output
Set value While the start signal is ON, the timer starts
UP
0 when the power comes ON or when the reset
Set value
DOWN input goes OFF.
0
Output mode C : Signal ON/OFF delay (Timer resets when power comes ON.)
SOURCE Timing starts when the start signal goes ON
Start signal
or OFF.
Reset
The status of the control output is ON when
Control output the start signal goes ON or OFF.
Set value
UP
0
Set value
DOWN
0
Output mode D : Signal OFF delay (Timer resets when power comes ON.)
SOURCE The control output is ON when the start signal
Start signal
is ON(except when the power is OFF or the
reset is ON).
Gate
Output mode F : Cumulative (Timer does not reset when power comes ON.)
SOURCE Start signal enables timing (timing is stopped
Start signal
when the start signal is OFF or when the
power is OFF)
Gate
DIMENSIONS : (mm)
N type(Surface Mounting): Using P2CF-08 , PF085A Socket or
PF113A Socket(for H5CLR-11/11M use only)
H5CLR
RUN
OUT
K/P
RESET h
START m
GATE s
RESET
Y type(Flush Mounting): Using Y50 Frame & US-08 Socket , P3G-08 Socket or
P3G-11 Socket(for H5CLR-11/11M use only)
H5CLR
RUN
OUT
K/P
45 +0.5
-0
RESET h
START m
GATE s
RESET
45 +0.5
-0