You are on page 1of 43
TEST REPORT FOR CIRCUIT BREAKER ‘owysno.101/2022 POSH Reportno:; | AUBR C01 | Jobno: 3228H POSH STEENBOK Date: 7210112023, Location: | DMC , DUBAI Class: ‘ABS ‘TEMPERATURE: 30 HUMIDITY: 40%. ‘TEST MODE: ‘Secondary injection “TEST DATE = 12.01.2022 RECOMMENDED TEST DATE 11-01-2023 J BREAKER NAME PLATE DATA M9 Family: MASTERPACT. Breaker Type NW25 ‘Standard 166 Trierrupt Rating: Ht Serial # 116505136002 TRIP UNIT DATA Family: MIGROLOGIC ‘Type: 208 Serial # 01992680 TRIP UNIT BASIC PROTECTION SETTINGS: Parameter AsFound | AsLeft | AsTested | Ft Current Level [Sensor Rating (FD 2500 A 2500 A LT Switch Setting (6) xh A Long Tire Pickup (I) axh 2500 A Long Tire Detay (t) 24 Sec inverse Definite Nin.Time Lag (kind OFF [Short Time Fckup (1s. kn) 410x6 25000 A Short Time Delay (tsd) 0 Sec_| Off instantaneous Pckup (P Off xn OA [Ground Faut Pickup (a) xh A [Ground Fault Delay (1a) ‘Seo [Ground Faut Push to Tip Button FFTK File Name:_ POSH-A-B-BUS-TIE Automatic Test Results Parameter Test Gurrent Level Trip Time Status [Long Time Pickup (ir) 47500 A Txt 16.13 Sec Pass [Short Time Fckup (sd, rp 31250_A, Wasxr | 0.06 Seo Pass. Instantaneous Pickup (6) xin [Ground Fault Pickup (Ig) xin ‘SINO GENERAL VOLTAGE AC RESULTS | REMARKS 7__ [SPRING CHARGE BY HANDLE 7200-250 V OK [ z CLOSE / OPEN OPERATIONS 200.250 V OK [ {3 UNDER VOLTAGE COIL "200-250 V OK | ‘OPERATION i | PROTECTIVE RELEASE = OK 1 VERIFICATION 5 BREAKER STATUS = OK 6 SPRING CHARGED 7 OK Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates, TEST REPORT FOR CIRCUIT BREAKER caw/sR0 01/2022 0 Client POSH AU.BR.C.01 | Job no: ‘322A Vessel: | POSH STEENBOK 1210172023 Location: | DMC, DUBAT ‘ABS BUSTIE A-B BREAKER TRIP CURVE t(s) Mioinim ——Maximem | NI wo Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates. MR. PRAKASH NAME & SIGNATURE NAME & SIGNATURE AUTOMATION FOREMAN ELECTRICAL ENGINEER(HOD) TEST REPORT FOR CIRCUIT BREAKER: POSH Reportno: | AU.BR COt | Vessel’ | POSH STEENBOK Date: | 1210772023 Location: | DMC, DUBAI Hi “Class: [Aas : BREAKER SERVICING - REFERENCE PICTURES 1. ARCHUTE SERVICES 's, Dubal Maritime City, Dubai - United Arab Emi sew/sn0 01/2022 0 Client: | POSH Peer Reportno: | AUBR CO ‘322AH [Vessel | POSH STEENBOK Dae 7210112023 Location: | OMC , DUBAI Class: ABS 2. BREAKER CONTACT SERVICES re — m TT t ‘cit Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates. ] TEST REPORT FOR CIRCUIT BREAKER cwsnoao.en2 | 0 POSH Report no: ‘AU.BR.C.02 | Job no: 322AH POSH STEENBOK Date: 12/01/2023 DMC , DUBAT Cem ‘ABS: TEMPERATURE Fy HUMDITY, : 30% ae TEST MODE: Senda necion TEST DATE: ‘20-2022 zl RECOMMENDED TEST oATE: | 1-01-2003 BREAKER NAME PLATE DATA is ary: MASTERPACT Breaor Toe: NIE Sear 16E TaUpl Rat! Sera BYTZBDREDEDOR TRIP UNIT DATA. Faniy: MIGROLOGIC “ype: 204 Sorat 1002858 TRIP UNIT BASIC PROTECTION SETTINGS Param fAsFound | Aston | As Tested | Pt Current Level Sensor Ratna fo) 1600.5 1600 A [er Swi Seting (op rT x Long Tire Peta (F Tan 700-8 Gong ire Day 9 24 S00 verse Dette. Tre aa a) OFF Short Tne Pcp (ed 10xF e000 A Shor Te Oly (8) 0 Seo | OF startaneous Pcp G) orf xn oA [round Fut kun 7 x [ound Feut ty Ca) See round Fou uch to Tip Baton FFikRe New POSHACBUS-TIE ‘Ritomatie Test Results Parameter Test Current Level Trip Time status Long Te Reap Timo A Tar | 132 See Pass Shor Te Pou (ed 000 A Wasnt | 008 S00 Pass staianeous Rekup (0) T frund Faut cx (a) zi SILNO GENERAL VOLTAGE AC RESULTS REMARKS 7 | SPRING CHARGE BY HANDLE 2002500 1 OK 2 | CLOSE / OPEN OPERATIONS 200250 OK 3 UNDER VOLTAGE COIL 200-250 V OK fs OPERATION | a PROTECTIVE RELEASE = VERIFICATION | BREAKER STATUS z SPRING CHARGED 7 Grandweld Shipyards, Dubai Maritime City, Dubal - United Arab Emirates. Fo TEST REPORT FOR CIRCUIT BREAKER ‘@w/sR0.103/2022 0 POSH Reportno: | AUBR C02 | Jobno: 322AH POSH STEENBOK Date: 20112023 DMC, DUBAT Class: ABS BUSTIE A-C BREAKER TRIP CURVE t(s) xir SS | oO MR. PRAKASH \ VTIREN NAME & SIGNATURE NAME & SIGNATURE ELECTRICAL ENGINEER(HOD) AUTOMATION FOREMAN Grandweld Shipyards, Dubal Maritime City, Dubal - United Arab Emirates. TEST REPORT FOR CIRCt BREAKER ew/sn0.101/2022 a 0 Client; | POSH Reportno; | AUBR C02 | Jobno: 322AH Vessel: _| POSH STEENBOK Date: 7210772028 Location: | DMC , DUBAI Class: ABs! BREAKER SERVICING - REFERENCE PICTURES 1, ARCHUTE SERVICES Grandweld Shipyards, Dubal Maritime City, Dubal - United Arab Emirates. ‘TEST REPORT FOR CIRCUIT BREAKER: cowistoanyan2 0 Client: _| POSH Reportno, [AUBR C02 _] Jobno: 322AH Vessel: POSH STEENBOK Date: 12101/2023 a ‘Location: OMC , DUBAI Class: ABS 2. BREAKER CONTACT SERVICES Grandweld Shipyards, Dubai Maritime City, Dubal - United Arab Emirates, TEST REPORT FOR CIRC IT BREAKER Fou ‘oww/saD 01/2022 POSH Reportno: | AU.BRC.03 | Job no ‘S22AH POSH STEENBOK Date: 71210712023, DMC, DUBAI Clas ABS ‘TEMPERATURE. 30 z 40% ‘Secondary injection 12-01-2022 RECOMMENDED TEST DATE: 1-01-2025, BREAKER NAME PLATE DATA Mig Famly: MASTERPACT ‘Greater Type: NTI: Standard 156 Terrpt atin: He ‘Serial #: 8112008596003 TRIP UNIT DATA Famiy: MIGROLOGIC “ype: 208 ‘Serial 02504827 TTRIPUNIT BASIC PROTECTION SETTINGS. Parameter ‘AsFound | Asteft | As Tested ‘Current Level Sensor Raing (A) 1600 A 1600 A LT Switch Seting (b) xn A Long Time Reka (1) Tn 7600.A Long Time Del () 2A Seo fnverse Osfnte Mn Tire Lag (Br) OFF [Short Tne ekup (16, Fr) 1oxr ye000 A Short Ti Delay (1S) 0 See | Off stentaneous Pekan ( Offxn OFA [Ground Faut chu (9) T A [Ground Fat Dey (6) ‘Sec [Ground Faut Push to Tp Buton FiTK Fie Nene POSH-BD-BUS-TIE ‘Automatic Test Results Parameter Test Current Level Trip Time Status Long Time Pe (7 71200 A Tar | 1584 Sec Pass Short Time Pckup (59. 20000 A Tas xr | 005 See Pass stantaneous chp () xh [Ground Fault ehup (o) xh GENERAL VOLTAGE AC RESULTS | REMARKS ‘SPRING CHARGE BY HANDLE 200-250 V OK LOSE OPEN OPERATIONS 200-250 V OK UNDER VOLTAGE COIL 200-2500 OK ‘OPERATION, i PROTECTIVE RELEASE = OK VERIFICATION BREAKER STATUS, OK SPRING CHARGED. OK Grandweld Shipyards, Dubal Maritime City, Dubal - United Arab Emirates. ST REPORT FOR CIRCUIT BREAKER ‘ew/sRo.101/2022 10 POSH Reportnor | AUBR.CO3 | Job no: 320RH POSH STEENBOK Date: 2101/2023 Location: | DMC, DUBAT Class: ABS BUSTIE B-D BREAKER TRIP CURVE Minima — Mai MR. PRAKASH -HTREN NAME & SIGNATURE NAME & SIGNATURE AUTOMATION FOREMAN ELECTRICAL ENGINEER(HOD) Grandweld Shipyards, Dubai Maritime City, Dubal - United Arab Emirates, Form: TEST REPORT FOR CIRCUIT BREAKER ‘Gw/SRD.101/2022 ‘0 Client: POSH Reportno: | AU.BR.C.03 | Job no: 322AH Vessel: | POSH STEENBOK Date: "1210112023 zi Location: | DMC , DUBAI Class: ABS BREAKER SERVICING - REFERENCE PICTURES. 1. ARCHUTE SERVICES Grandweld Shipyards, Dubai Maritime City, Dubal - United Arab Emirates. TEST REPORT FOR CIRCUIT BREAKER cow/sto byez fo POSH Reportno: | AUBR.C.03 | Job no: — ‘322A | POSH STEENBOK aamiooed Location: | DMC, DUBAI 7s 3. BREAKER ACCESSORIES SERVICES & TESTING Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates. TEST REPORT FOR CIRCUIT BREAKER wstoabyeaze "0 POSH Reportno: | AU.BR 6.04 | Job no: 322AH POSH STEENBOK Date: 2107/2023 DMC, DUBAI Class: ‘ABS TEMPERATURE: 30 HUMIDITY: 40% a TESTMODE: ‘Secondary injection ‘TEST DATE 12-01-2022 RECOMMENDED TEST DATE: 11-09-2023 BREAKER NAME PLATE DATA Mig. Famiy: MASTERPAGT Breaker Type: NT12 ‘Standard: IEC Tnierupi Rating: He Serial B11982634000% TRIP UNIT DATA Famiy: MIGROLOGIG Type: 20 A Serial 02585054 TRIP UNIT BASIC PROTECTION SETTINGS: Parameter ‘AsFound | Asteft | AsTested | Ft Current Level [Sensor Rating (n) 12504 1250 A [LT Switch Soting (i) x A Long Tere Fokup(F) oa an 1000 Long Tere Deby (1) 2 See [rverse Define Min Time Lag (ra) OFF [Short Tine Pkup (In) 4xr 4000 A [Short Tine Dee (tsd) 0 Sec_| Off Instantaneous Pckup ofan OWA [Ground Fauht Pckup (o) Ty A [Ground Fault Delay (to) Sec [Ground Fault Push io Tip Button FEIKFis Name POSH-BT-2 ‘Automatic Test Results Parameter ‘Test Gurrent Level Trip Time Status Long Time Pip (F) 3000 A Sur | 753 Sec Pass Shor Tine Pickup (6. np 3000 A Sar | 005 See, Pass Instantaneous Pekup (0) TT [Ground Fault kup () iT SLNO ‘GENERAL VOLTAGE AC RESULTS | REMARKS 1 SPRING CHARGE 8Y HANDLE 200-250 V OK 2 ‘CLOSE 7 OPEN OPERATIONS 200-250 V OK 3 UNDER VOLTAGE COIL 200-250 OK ‘OPERATION. [4 PROTECTIVE RELEASE = OK VERIFICATION eee 5 BREAKER STATUS = OK 6 ‘SPRING CHARGED = OK Grandweld Shipyards, Dubai Maritime City, Dubal - United Arab Emirates. Form TEST REPORT FOR CIRCUIT BREAKER ‘GW/SRD,101/2022 #0 POSH Reporte: | AUBR C04 | Jobno: 3220 POSH STEENBOK Date: 1210112023 i DMC, DUBAI Class: ‘ABS BT-2 BREAKER TRIP CURVE 109000 t(s) Minimum — Maximum o ow . HIREN NAME & SIGNATURE ELECTRICAL ENGINEER(HOD) MR. PRAKASH NAME & SIGNATURE AUTOMATION FOREMAN Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates REPORT FOR CIRCUIT BREAKER Form sew/sRo.101/2022 0 Client: | POSH Reportno: | AU.BR.C.04 | Job no: 322AH Vessel: | POSH STEENBOK Date: 72/01/2023 A Location: | OMC , DUBAI Class: [aes BREAKER SERVICING - REFERENCE PICTURES 1. ARCHUTE SERVICES Grandweld Shipyards, Dubal Maritime City, Dubal - United Arab Emirates. TEST REPORT FOR CIRCUIT BREAKER cow/snoi01/2002 RO POSH in Reportno: | AUBR.C.04 | Job no: ‘322AH | POSH STEENBOK DNs 7210172023 ; | DMC , DUBAT Class: “BS 2. BREAKER CONTACT SERVICES en | 3. BREAKER ACCESSORIES SERVICES & TESTING Grandweld Shipyards, Dubat Maritime City, Dubai - United Arab Emirates. TEST REPORT FOR CIRCUIT BREAKER: cow/sroanvanze *0 POSH Reportno; | AUBR.C05 | Jobno: ‘322RH POSH STEENBOK Date: "1210112023 DNC , DUBAI Class: ‘ABS “TEMPERATURE. 20 HUMOITY: 40% TEST MODE: Secondary irjacton ‘TEST DATE: ‘12.01.2022 RECOMMENDED TEST DATE: “01-2023 A aaa BREAKER NAME PLATE DATA ia Family MASTERPACT Breaker Type: NTOB: Siaidard TES Tierrpt Rating He Soria BI19826380007 TRIP UNIT DATA Faniy. MICROLOGIC “Type 208 ee Sori #02585087 TRIP UNIT BASIC PROTECTION SETTINGS Parameter ‘As Found | Asteft | As Tested | i ‘current Lev [Sensor Rating (h) 800 A 800A Sw ten Seting (5) am A Long Tine Rehm (1) Tor a0 A Long Tere Delay (i) 24 Sec verse Defnde hin Tme Lag (mi) OFF [Short Time Fokup (6. m) t0xt 00a [Shor Tre Deby (50) 0 Seo | of instantaneous Rekup onan Ona [Ground Fault Pekup (a) on | A [Ground Fat Delay (i) See [Ground Faut Aish to 1rp Baton FFTKFietiane POSH-CD-BUS-TIE ‘Automatic Test Results Parameter Test Current Level Trip Time Status Long Tie Rehm 1 5500 A Tar | 15 see Pave [Short Time Rokup (64h) 10000. Tasxr | 006 See Pass stantaneous Rekup () oe [Ground Faut Fekup (a) oe SINO GENERAL VOLTAGE AC [RESULTS | REMARKS 1 ‘SPRING CHARGE BY HANDLE 200-250 V | ‘OK 2 ‘CLOSE J OPEN OPERATIONS 200-250 OK 3 UNDER VOLTAGE COIL 200-250 V OK OPERATION oe 4 PROTECTIVE RELEASE = OK VERIFICATION 5 BREAKER STATUS = OK 6 SPRING CHARGED = OK Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates. i T ry 1 foo TEST REPORT FOR CIRCUIT BREAKER ‘Gw/SRo,101/2022 0 Cli POSH Report no: | AU-BR.C.05 | Job no: 322AH Vessel: | POSH STEENBOK Date: 1210112023 Location: | DMC, DUBAI Class: ABS: BUSTIE C-D BREAKER TRIP CURVE ‘100000 t(s) Simm — oem MR. PRAKASH NAME & SIGNATURE AUTOMATION FOREMAN Oy r- . HIREN NAME & SIGNATURE ELECTRICAL ENGINEER(HOD) Grandweld Shipyards, Dubai Maritime City, Dubal - United Arab Emirates. @ TEST REPORT FOR CIRC! BREAKER owistosou/i0z2 0 Client: | POSH Report no: | AU.BR.C.05 [vob no: ‘S22AH Vessel: | POSH STEENBOK Date: ~~ | 1210172023 i Location: | OMC , DUBAI 7 Class: ABS BREAKER SERVICING - REFERENCE PICTURES 1. ARCHUTE SERVICES Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates. faim EST REPORT FOR CIRCUIT BREAKER cowrsno 10/2022 ‘0 cli POSH Report no: ‘AU.BR. C.05 I Jobno: | 322AH Vessel: | POSH STEENBOK Date: 12/01/2023 Location: | DMC, DUBAT Class: ABS 2. BREAKER CONTACT SERVICES = Bo oe 3. BREAKER ACCESSORIES SERVICES & TESTING Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates, TEST REPORT FOR CIRCUIT BREAKER cowisto soya 0 Client: | POSH Reportno:; | AU.BRC.06 | Jobno: 322A Vessel: | POSH STEENBOK Date: 7210112023 i Location: | DMC , DUBAI Class: ABS ‘TEMPERATURE: 20 HUMIDITY: 40% TEST MODE: ‘Secondary injection TEST DATE: 12.01.2022 RECOMMENDED TEST OATE: 11-01-2023 BREAKER NAME PLATE DATA Mg: Family: MASTERPACT Breaker Type: NTOS: Standard: EC interrupt Rating: He Serial # 8116505386004 TRIP UNIT DATA Family: MICROLOGIC Type: 5.08 Soval# 02142974 TRIP UNIT BASIC PROTECTION SETTINGS Parame ‘As Found | AsLeft | AsTested | ft Current Level [Sensor Rating (In) 800 A 800 A LT Switch Seting (o) TT A Long Time Pickup (F 08 xin 40 A Long Tie Delay (i) 0.5 Sec verse Definite Mn. Tire Lag (rt) OFF [Short Time Pickup (6d, fn) 25x06 1600 A Short Time Doty (sd) 0.4 sec_|_of instantaneous okuo (i 15x "72000 A [Ground Faut Pickup (9) xin A [Ground Faut Delay (tg) Sec [Ground Fault Push to Trp Button FETK Fie Name: POSH-DGA ‘Automatic Test Results: Parameter ‘Test Current Level Trip Time Status Long Time Fickup (F) 1280 A 2xk | 458 Sec Pass [Short Time Pickup (6, 6800 A 10.63 xi | ot Seo Pass Trstanianeous Pickup (I) 15000. 1875 xi | 0.05 Seo Pass [Ground Fault Pcku (ta) xh {SINO GENERAL Hy VOLTAGE AC RESULTS | REMARKS [[1__[- SPRING CHARGE BY HANDLE 200-250 V OK 2__| _ CLOSE / OPEN GPERATIONS 200-250 V OK [3 UNDER VOLTAGE COIL 200-250 V OK ‘OPERATION i et [4 PROTECTIVE RELEASE = OK VERIFICATION a 5 BREAKER STATUS OK 6 ‘SPRING CHARGED. OK Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates. ‘TEST REPORT FOR CIRCUIT BREAKER ws aoiz022 POSH Reportno: | AUBR.C.06 | Job no: 322AH Vessel; | POSH STEENBOK Date: 4210112023 Location: | DMC , DUBAI Class: ABS DG-1 BREAKER TRIP CURVE 00000 t(s) Hnmum — Maxim] G i oe MR. PRAKASH . HIREN NAME & SIGNATURE NAME & SIGNATURE ELECTRICAL ENGINEER(HOD) AUTOMATION FOREMAN Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates. TEST REPORT FOR CIRCUIT BREAKER Form 5w/5Ro,201/2022 nO POSH Reportno: | AUBR C06 | Jobno: 22K POSH STEENBOK Date: 210172023, Location: | DMC , DUBAI Class: ABS BREAKER SERVICING - REFERENCE PICTURES 1. ARCHUTE SERVICES Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates. TEST REPORT FOR CIRCUIT BREAKER cowiseo 1/2022 RO POSH Reportner[AUBRC06 [Jobno: [32204 Vessel; | POSH STEENBOK Date: 1210112023 | Location: | DMC , DUBAI - Class: ABS 2. BREAKER CONTACT SERVICES Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates. ‘TEST REPORT FOR CIRCUIT BREAKER cow/sto12022 0 POSH Reportno: | AU.BR.C.07_| Jobno: ‘322AH POSH STEENBOK Date: F2I0T12023 DMC , DUBAI | ABS TENPERATURE: 20 Humor. 0h TEST MODE ‘Seconda injecon TEST OATE: 1291-2022 RECOMMENDED TEST OATE: | 11-01-2025 BREAKER NAME PLATE DATA wig Femiy: MASTERPACT Breaker Type NTO Sanders TES WernptRetng He Serial 8116505386 TRIP UNIT DATA. Family, MICROLOGIC Type: 5.0 A Serial #: 02143023 __TRIP UNIT BASIC PROTECTION SETTINGS: Parameter As Found | Asteft | AsTested | i Current Level [Sensor Rating (In) ee ~ | 800 A 800 A [cTSw den Seting (op oh A ong Time Fekup () txh HOA |Long Time Delay (tr) 05 Sec verse Detinte Nin Tine Lag (ant) OFF [Short Tme Pokup (64, 25x40 1600 A [Short Te Delay (sd) 04 Seo] Of istantaneous Pekup 76x 72000 A [Ground Faur Fckup (b) rT A [Ground Faut Delay (to) see [Ground Fault Push to Trip Button See FFTK File Name: POSH-DG-2 Automatic Test Results Parameter ee Test Current Le Trip Time status Long Tere elu () i220 A Tur | 463 see Pass [Sort Tmo Pokup (86, Tso xr | oat See Pass stantancous Pekup @) 175 xn | 008 Sec Pass: [round Faut ekup (6) on a ‘SI.NO. GENERAL VOLTAGE AC RESULTS REMARKS + | SPRING CHARGE BY HANDLE 200-250 V ‘OK 2 | CLOSE 7 OPEN OPERATIONS 200-250,V ‘OK 3 UNDER VOLTAGE COIL ‘200-250V—— ‘OK OPERATION + PROTECTIVE RELEASE = OK L VERIFICATION 3 BREAKER STATUS = OK 6 SPRING CHARGED Si OK Grandweld Shipyards, Dubai Maritime 1d Arab Emirates. TEST REPORT FOR CIRCUIT BREAKER Fer ew/sno.101/2022 fo ci POSH Reportno: | AUBRCO7 | Jobno: 322AH Vessel: _| POSH STEENBOK Date: 4210112023 Location: | DMC, DUBAI Class: ABS DG-2 BREAKER TRIP CURVE 100000 t(s) tinimim — vax] es oF MR. PRAKASH. . HIREN NAME & SIGNATURE NAME & SIGNATURE AUTOMATION FOREMAN ELECTRICAL ENGINEER(HOD) Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates, TEST REPORT FOR CIRCUIT BREAKER owseo soem fo POSH Reportno: | AU.BRC.07 | Job no: 322AH POSH STEENBOK Date: ¥2I0172028 Location: | DMC, DUBAI Class: ABS BREAKER SERVICING - REFERENCE PICTURES 1. ARCHUTE SERVICE Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirate TEST REPORT FOR CIRCUIT BREAKER Form: ‘ow/sto.101/2022 fa Client: POSH Report no: AU.BR.C.07 | Job no: ‘322AH Vessel; | POSH STEENBOK Date: "120112023 Location: | DMC , DUBAI Class: ABS 2. BREAKER CONTACT SERVICES TEST REPORT FOR CIRCt TT BREAKER Form «ews 3032002 0 POSH Reportno: | AUBR.C.08 | Job no: 322AH POSH STEENBOK Date: *2i0172023 Location: | DMC, DUBAI Class: [ABs “TEMPERATURE: 30 HUMOITY: 40% ‘TEST MODE ‘Secondary jection TEST DATE: 12.01.2022 RECOMMENDED TEST DATE: ‘1-01-2023 BREAKER NAME PLATE DATA ig Fam MASTERPACT Breaker Type NWI Slandard TE FieuptRaing AE Serial #817 9826350002 TRIP UNIT DATA Famiy. MICROLOGIC Type 508 Sonal OTSA ‘TRIP UNIT BASIC PROTECTION SETTINGS [Param eter ‘As Found | Asleh | As Tested | CurrentLevel [Sensor Rating tr) 00 200A [CT Switch Seting (io) xh R [Long Tine Fekup (0) Osx 720A [Cong Tire Delay () ase inverse Defnte in Tere Lag (Gt) oF I~ Stor Time Pika (sd, 25x0 eHOR [Shor Tere Delay (ts) Os Se | Of nstantanesus Fekup 1x 00K (Ground Faut Pick (0) xn R (Ground Fast Deay (a) See [Ground Fauk Push o Tip Baton FFikFielane POSHSG4 ‘Automatic Test Results Param eter Test Current Level Trip Time ‘Status Long Tire Pickup (F) SOA i_| AB8 Sec Pass [Shor Tare ACK (0 Fy 22600 Bink 026 Sec Pass instantaneous Pekup () 480008 Axin_| 0.06 See Pass [Ground Fauk Pickup () xh ‘SINO GENERAL VOLTAGE AC [RESULTS | REMARKS 1 SPRING CHARGE BY HANDLE 200-250 V | OK 2 ‘CLOSE OPEN OPERATIONS 200-250 V [ (OK 3 UNDER VOLTAGE COIL 200-250 | OK (OPERATION a PROTECTIVE RELEASE = OK VERIFICATION 5 BREAKER STATUS = OK ane ‘SPRING CHARGED Ho = OK 7 Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates. Forms TEST REPORT FOR CIRCUIT BREAKER ‘@wy/sR0.101/2022 70 POSH Reportno: | AUBR.C.08 | Jobno: 322AH POSH STEENBOK Date: TRIOTT2023 DMC , DUBAT Class: ABS SG-1 BREAKER TRIP CURVE Weim — Maxima \.Qust— MR. PRAKASH NAME & SIGNATURE AUTOMATION FOREMAN 0 Wr HIREN NAME & SIGNATURE ELECTRICAL ENGINEER(HOD) Grandweld Shipyards, Dubai Maritime City, Dubal - United Arab Emirates. Client: Vessel: Location: BREAKER SERVICING - REFERENCE PICTURES 1, ARCHUTE SERVICE Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates, w/sRo.101/2022 ‘322A REPORT FOR CIRCUIT BREAKER ows 4222 fo ~ | POSH Reportno: | AU.BR.C.08 | Jobno: 322AH_—— POSH STEENBOK 7210112028 cet | DMC , DUBAI | Class ~ | ABS Pee eee Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates. TEST REPORT FOR CIRCUIT BREAKER cw/sto 12022 0 Client: | POSH Report no: | AUBR.C09 | Job no: ‘S22AH Vessi POSH STEENBOK Date: | 12/01/2023 Location: | DMC, DUBAI Class: [ABs TEMPERATURE: 30. [aumorry 08 TEST MODE Secondary injection TEST DATE 201-2002 RECOMMENDED TEST oATE: | 11.01.2003 BREAKER NAME PLATE DATA a Fammiy: MASTERPACT Dresher Type. MABE Sanders Tiarapt Rating” Ht Sonal BY 9526900007 TRIP UNIT DATA Family. MIGROLOGIC Type: 59 A are Seral#: 09114760, TRIP UNIT BASIC PROTECTION SETTINGS Sen Parameter ‘As Found | Ae Left | As Tested [Ft Current Level [Sensor Ratna (rd 3200 A 3200 A LT Sw itch Setting (Jo) xh A Cong Tine Pla (F) Dae xh Taw A Long Tere Delay (0) 0 See Inverse Definge Min. Tme Lag (iimt) ‘OFF ia Son Time Fila (6d tm) wa Short Tine Delay (53) 03 Seo | OF stantaneous Rekup GD tx Tei00 A Ground Fout Pickup Co) 7 A [Ground Fault Delay (tg) Sec oe [Ground Fauk Rush to Trp Buton FFTK Fie Name: POSH-SG-2 Automatic Test Results | Parameter Test Current Level Trip Time status Long Tene Pokop Baa A Zan [470 soc Pass Short Tine lok (6d. WD 72600-A B51 xr | 026 See Pass Instantaneous Pekup (i) 48000. 18xn | 005 See Pass [Ground Fault Pickup (la) xh an SILNO- GENERAL VOLTAGE AC RESULTS REMARKS 1 | SPRING CHARGE BY HANDLE 700-250 V OK 2 ‘CLOSE / OPEN OPERATIONS: "200-250 V 7 OK 3 UNDER VOLTAGE COIL 200.250 OK OPERATION a PROTECTIVE RELEASE = OK VERIFICATION 5 GREAKER STATUS = OK 6 ‘SPRING CHARGED = Oo | Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emira EST REPORT FOR CIRCUIT BREAKER ows size 0 POSH Reportno: | AU.BR.C.09 | Job no: ‘322AH POSH STEENBOK Date: 4210112023 DMC, DUBAI Class: ABS SG-2 BREAKER TRIP CURVE 100000 t(s) xir rar = Maxim | MR. PRAKASH TREN NAME & SIGNATURE IE & SIGNATURE AUTOMATION FOREMAN ELECTRICAL ENGINEER(HOD) Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emir TEST REPORT FOR CIRCUIT BREAKER Da 2101/2023 Class: a) Location: | DMC, DUBAl BREAKER SERVICING - REFERENCE PICTURES. 1. ARCHUTE SERVICES Grandweld Shipyards, Dubai Maritime City, Dubai - United Arab Emirates, Reportno: [AUBRC09 [Jobno: | 322AH |

You might also like