You are on page 1of 11
GOULDS PUMPS Goulds Model 5100 Vertical Cantilever Top Suction Pumps © 1985, Goulds Pumps, Inc. Goulds Model 5100 Vertical Cantilever Pumps Designed for Corrosive/ Extremely Abrasive Slurries Capacities to 7500 GPM (1703 m®/n) Heads to 240 feet (73 m) Temperatures to 200°F (93°C) Pit Depths to 11 feet (3.4 m)" Solids to 3-3/8 in. (86 mm) *Deptnstoa eet (@:2m) with submerged bearing design (page 1). Design Features Cantilever Design No submerged bearings. (Submerged bearing design optional.) External Impeller Adjustment Maintains pump efficiency and performance. Dual Volute Casing Eliminates radial unbalance; reduces wear Materials of Construction Available ina wide range of corrosive/abrasive resistant alloys. Heavy-Duty Bearings Top Suction Eliminates air binding. Ease of Maintenance Removal of rearhead provides easy access to all wear parts. ‘Maximum Interchangeability Services Coal Prep Plant Fly Ash Sump Mine Slurry ‘Storm Water Runoff Iron Ore Slurry Effluent Sludge Phosphate Mining Clarified Water Lime Sturry Froth Flotation Ash Slurry Waste Chemicals Clean-up Sump Foundry Sand Heavy Media Separation Clay Slurry Coal Pile Runoff Underflows TRACE EC OSC Heavy-Duty Design Features for Wide Range of Severe Corrosive/Abrasive Slurry Services DIRECT OR BELT DRIVE Direct EXTERNAL IMPELLER ADJUSTMENT Permits restoring running clearance ‘ter abrasive wear without de ‘assembling pump, Maintains pump Application Flexibility Direct or Belt Drive cous ots cive anangaments to meet speci user requirements Bolt drive allows use of standard speed motors ‘wi full diameter Direct drive offers Impellrs. Adapts pump ‘simplicity, ease of Rormeet any head or instalation and ‘capacity, Extends wear ‘minimum ie through tow ‘maintenance. ‘operating speeds Optional Floor Plate ‘Two standard floor plate con- figurations, circular and rectangular, are available. Custom designed floor plates can be provided. Horizontal Pumps Goulds makes a complete line of horizontal abrasive slurry pumps in sizes from 2” to 14” discharge with capacities to 30,000 GPM (6813 mi/h) and heads to 970 feet (113 m). Pumps are available in side suction or end suction con- figurations, The side suction design offers inherent advantages such as low sealing water requirements, and ease of maintenance — pumps can be repaired without disturbing piping, Pact Name Car ear Head ‘Suction ner impetie Bearing End Cover Tews Beam ‘Salt Dotesior ‘Sat Sess “Thrust Bearing Hon ain ering inpoler Key 12 192 795 Baa ‘Bearing Frame ‘bt | impede Fat ‘315__|_Dischar 53 Lip seal PaCS aa rgttorad Paso Rowe bow Corporation Materials of Construction 1H0500 | High Chrome hon — Simla to ASTM ASS2 C12 Type D HC600 | igh Chrome iron — Sima to ASTM ASS2 C13 Type A PACE™ | Proprietary — Abex Corporation ‘Goyne 316 | Similar io AISI S16 or AC! CFM (eae Elsi Penn Modified AIS 1144 rs-machring seal CTT eS Taal Penn Fubper 2 ale ala 2lé g|z ele ele elelé lel alelel als] z Sal dala lala lalla ls | ele = lca cl late Va sete ae ster nae atins ee eS Sectional View model 5100 Hydraulic Coverage Model 5100 capacity — mim 150 m0 500 tomo mo 150000 rT | 0 ‘TOTAL HEAD — FEET sua1an —ovaH Wi0L (600 a00 100015002000 [GALLONS PER MINUTE Pum Size x3 12, 454K Sxant0, 5x0 x15 Pump Size exe e (6x0 178, 6x8x2,6x 0x1, x On TH C_ | frat ax8x21% ‘Bx Ox Wh, Bx 10K Ws 6x8, Bx TOE, Dx ae 66x 15, xx 18 4xGxET 012421 ©] Sx@n16.6x6x 17%, 6xORT7E, txOx 1, Bx Ox 710x124 i bxBx21 Gx6410,6x8x71,4x6x017, OXOKETD 646417, 6x0471, 8410471, 004217 EUTEIES (6x8x21,6x 10271, 0x De7T B02, 10x 2d, x ATT FEESISEIEA Gate ea ae att [1851470 standard 33 (898) | | stgensien® [42 000) | 25,000) sresn— 10s eer — a6 —] (Caesars Tastes | MOY Faaiizt 9070 Sx 208 (623) 3 in. (76 mm) __38 086) 23 (584) eee cae on 2) si) | 097) 68-21 | Bei | oseer) soem | 3.6%) Siem er [atoat aoa aia) aew fosraei | s06 6) $3118 ap go, $2121 535 (851) 66 (1676) = A 3 (5) 455 (158) 208 (1290) 33.4 (355) Dimensions °. u 7 ss) _| 258 eo) 25 (660) 290737) 30762 280 (733) 338 658) Submerged Bearing Design For Deeper Sumps For settings greater than 11 feet (241m), Goulds afers a submerged Model 5100 bearing design. Hydraulic coverage s merge Bor, Same as cantlever design since both Steton Pome"? lse same wet end pars, EXTERNAL IMPELLER, ADJUSTMENT Maintain original performance. DUPLEX THRUST. BEARINGS. High thrust capability extends ‘mochanieat ile and overall reliably. Grease-lubricaled, ‘Sealed for outdoor instalation. HEAVY COLUMN PIPE: Provides rigid support for pump ‘and bearings. REPLACEABLE SHAFT SLEEVE STEADY BEARING Under bearing to protect shat. HOUSING ‘Accurate machined register fit of ‘column and bearing housing ‘assures bearing and shalt alignment. Cuties rubber or bronze bearings avalable for waler or grease lube. in Slurry Pumping. ..Backe Goulds Slurry Pump Division (formerly Morris Pumps, Inc. and Goyne Pump Company) utilizes a combination of experience and state-of-the-art techniques such as computer-aided design (CAD) to assure that all products, both old and new, meet the highest standards. of performance. Goulds own state-of-the-art foundry with heat treat capability is unsurpassed in the industry. Many special alloys have been developed for particular slurry pump applications. The most rigid quality standards are imposed on all parts and pumps. Samples of all alloys are checked by spectrometer at Goulds foundry to assure the metalluray and hardness are right. Other tests from hydrostatic to vibration and performance provide the user with ‘confidence that the pump will perform as intended Goulds has the finest parts program in the industry. Ready availability of parts is assured by Goulds network of warehouses and distributors. Availability, Service, Quality and Value of pump parts is Goulds commitment. Since Goulds makes pumps and nothing but, every salesman is a pump specialist. He can tell you which ump is best for the job, oversee delivery, advise proper installation, and assure the customer of service .. right. down the line. Plus engineering support from the division ... experienced engineers who are committed to service Goulds has a fully equipped slurry lab designed to test customers’ slurries for pump performance and pipeline characteristics, This added service allows the best pump for the service to be specified One Cantilever Design—Four Pump Models Model 5100 Model 5150 Vertical Cantilever Vertical Cantilever Top Suction Pump Bottom Suction Pump Model VJC Vertical Cantilever Bottom Suction Pump Model VHS Vertical Cantilever Recessed Impeller Pump, Designed for wide range of Ccortosive and severe ry services. ‘abrasive slurry services. Top jon removes suction design eliminatesair is trom sump floor. binding, provides ease of Handles solids o 3-7 in. minora, cs (98mm) Submergesbearing ‘Similar to Model 5150, WJC ‘Submerged bearing design also available. Designed to handle are or fibrous soles. Recess ‘non-clog impelor ‘maximum solid sizes equal to pump suction. Solids to 10in. (254 mm). Also matress peers ope eee feunmceacen | Sls eal ae ese eee, was Hydraulic Coverage Hydraulic Coverage Hydraulic Coverage Hydraulic Coverage : : i i = i 2 i call lao Pes . ‘cauLos PER wn. ‘OkLLONS PeR MINUTE “GALLONS PER MINUTE For more information about Goulds Vertical Cantilever Pumps, calll your nearest Goulds sales office or representative. (soups | PUMPS. INC, CA FALLS NEW YORK [3148 Form No. SPO-63 4/85 Printed in USA,

You might also like