You are on page 1of 2

MAXPRO®

ACCESS
CONTROL
NEXT
GENERATION
ACCESS
CONTROL
INTRODUCING With its superior
MPA2 INTELLIGENT 2-DOOR MAXPRO flexibility and
ACCESS CONTROL PANEL. scalability,
MPA2 works
Meet the most stringent compliance requirements with more capacity. MPA2 hard for your
provides larger card databases, access levels and event buffers to offer a modular, business.
scalable, and flexible solution.

Lower Cost Per Door


• 20% lower price for 2-door MPA2 vs 2-door
NetAXS-123
• 8% lower price for 6 doors vs NetAXS-123

OSDP Support
• Provides an encrypted, bi-directional
communication path between the reader and
control panel (OSDP)
• Legacy Wiegand support for retrofits and
takeovers

Reduce Install Time


• No screwdriver necessary, simply plug-in the
Ethernet cable (click & done!)
• Standardize on Cat5/6 cabling
• QR Code Configuration Coming Soon

Backwards Compatible
• Easily upgrade existing NetAXS
• Same interface as NetAXS reduces training time

3-in-1 Host Modes


• Manage using the Embedded Browser, MAXPRO
Cloud, or WIN-PAK Software
SPECIFICATION
COMPARISON TABLE
MPA2 VS NETAXS123
SPECIFICATION NETAXS.123 MPA2

BUILT-IN COMMUNICATION
Ethernet; RS-485; USB 2 x Ethernet; 3 x RS-485; 2 x USB
OPTIONS

1 Door/2 Readers -
Door/Reader capability 2 Door/4 Readers
(expandable to 3 Doors/6 Readers)
READERS / DOORS

Reader compatibility Standard Wiegand supported OSDP and Wiegand supported

2 SPDT (jumper-selectable NO or NC) per door 4 SPDT (jumper-selectable NO or NC) per door rated
rated at 3 A@28 VDC; 2 open collector outputs at 3 A@28 VDC; 4 open collector outputs (OC) rated
OUTPUTS Number of outputs
(OC) rated at 16 mA@12 VDC: reader LED (Aux) at 16 mA@12 VDC: reader LED (Aux) and reader
and reader buzzer (Aux) per door are available buzzer (Aux) per door are available

6 configurable four-state supervised inputs 8(+4) configurable four-state supervised inputs


points (Factory default settings are: Status, REX, points (Factory default settings are: Status, REX,
Number of inputs
Reader Tamper A, Reader Tamper B, Power Fail Reader Tamper A, Reader Tamper B, Power Fail and
INPUTS and General Input) General Input)

Power-fail and
Yes Yes, Panel Door, Off-Wall and External Tamper
Panel tamper

100 to 240 VAC, 50/60 Hz Input Provides 13,8 VDC,


93-264 VAC, 50/60 Hz input provides 12 VDC,
POWER INPUTS Unit input 3,5A Output, Battery Voltage Low Shutdown at
4 A output
10.50 V

Power for locks/strikes/ 1.15 A per Door for Locks/Strickes, Readers, and 1.25 A per Door for Locks/Strickes, Readers, and Input
POWER OUTPUTS
reader(s)/input devices Input Devices (3.5 A @ 12 VDC total) Devices (2.5 A @ 12 VDC total)

ENCLOSURE Wiring access holes/knockouts 19 24

INSTALLATION Graphic wiring cards/labels Yes Yes (Intuitive Info Card)

SYSTEM Processor Freescale Coldfire 32-bit IMX6-X1 (10 x Faster)

12 LEDs total (12V Power, PoE, Over Current, 37 LEDs total (13,8V Power, PoE, Over Current,
LEDS Status leds Ethernet, RS-485, reader[s], Door State, Run, Ethernet, RS-485, reader[s], Door State, Run, Relay
Relay Status) Status, ...)

Card and event buffer capacity 100,000 Card Capacity; 25,000 Event Capacity 100,000 Card Capacity; 100,000 Event Capacity
CARDS AND DATABASE
Access levels 128 65,535

Honeywell Commercial Security


Security715 Peachtree Street NE
Atlanta, GA 30308
security.honeywell.com © 2020 Honeywell International Inc.