ตารางที่ 1 บ ันทึกผลการทดลองของอ ัตราการไหลของนา้ 27.

5 g/s
 เมือ ่ ความต่างศักย์ไฟฟ้ า
่ เพิม
Flow rate (measured): 0.0275 kg/s
Area of condenser : 0.0320 m2
Area of heater : 0.0018 m2
Heat capacity of water 4.1800 kJ/kg-°C

Boiling heat Boiling


No. V (Volt) I (A) Theater 2 2
Tliquid (°C) DT (°C) Q (W) q (W/m ) h (W/m -°C)
(°C)
1 0 0.00 24.2 23.0 1.2 0.00 0.00 0.00
2 10 0.13 24.5 26.0 1.5 1.30 722.22 481.48
3 20 0.28 24.0 29.0 5.0 5.60 3111.11 622.22
4 30 0.40 25.0 34.0 9.0 12.00 6666.67 740.74
5 40 0.54 25.0 32.0 7.0 21.60 12000.00 1714.29
6 50 0.67 25.0 35.0 10.0 33.50 18611.11 1861.11
7 60 0.82 25.0 37.0 12.0 49.20 27333.33 2277.78
8 70 0.95 25.0 39.0 14.0 66.50 36944.44 2638.89
9 80 1.10 26.0 40.0 14.0 88.00 48888.89 3492.06
10 90 1.24 26.0 42.0 16.0 111.60 62000.00 3875.00
11 100 1.37 26.4 43.0 16.6 137.00 76111.11 4585.01
12 110 1.57 27.0 45.0 18.0 172.70 95944.44 5330.25
13 120 1.65 27.3 47.0 19.7 198.00 110000.00 5583.76
14 130 1.82 27.5 50.0 22.5 236.60 131444.44 5841.98
15 140 1.97 27.8 56.0 28.2 275.80 153222.22 5433.41
16 150 2.07 28.5 63.0 34.5 310.50 172500.00 5000.00
17 160 2.22 30.0 75.0 45.0 355.20 197333.33 4385.19
18 165 2.28 30.5 87.0 56.5 376.20 209000.00 3699.12

Condenser Condensing
No. P (kPa)
Tin (°C) Tout (°C) DT (°C) DTL (°C) Q (W) q (W/m2) h (W/m2-°C)
1 15.2 16.1 0.9 8.5 103.46 3232.97 378.47 93.325
2 15.5 15.8 0.3 8.8 34.49 1077.66 121.78 93.325
3 15.4 16.0 0.6 8.3 68.97 2155.31 259.79 94.325
4 15.5 16.0 0.5 9.2 57.48 1796.09 194.22 95.325
5 15.5 16.0 0.5 9.2 57.48 1796.09 194.22 95.325
6 15.5 16.0 0.5 9.2 57.48 1796.09 194.22 96.325
7 15.5 16.5 1.0 9.0 114.95 3592.19 399.54 97.325
8 15.5 16.5 1.0 9.0 114.95 3592.19 399.54 99.325
9 15.5 16.6 1.1 9.9 126.45 3951.41 397.53 100.325
10 15.5 16.9 1.4 9.8 160.93 5029.06 514.05 101.325
11 15.5 17.2 1.7 10.0 195.42 6106.72 609.09 102.325
12 15.5 17.5 2.0 10.5 229.90 7184.38 686.31 103.325
13 15.5 17.6 2.1 10.7 241.40 7543.59 703.97 105.325
14 15.5 17.9 2.4 10.8 275.88 8621.25 801.57 106.325
15 15.5 18.5 3.0 10.7 344.85 10776.56 1004.32 109.325
16 15.5 19.0 3.5 11.2 402.33 12572.66 1126.72 112.325
17 15.8 19.5 3.7 12.3 425.32 13291.09 1084.36 114.325
18 16.2 20.2 4.0 12.2 459.80 14368.75 1178.65 119.325
ตารางที่ 2 บ ันทึกผลการทดลองของอ ัตราการไหลของนา้ 27.5 g/s
่ ลดความต่างศักย์ไฟฟ้ า
 เมือ
Flow rate (measured): 0.0275 kg/s
Area of condenser : 0.0320 m2
Area of heater : 0.0018 m2
Heat capacity of water 4.1800 kJ/kg-°C

Boiling heat Boiling


No. V (Volt) I (A) Theater
Tliquid (°C) DT (°C) Q (W) q (W/m2) h (W/m2-°C)
(°C)
1 165 2.28 30.5 87.0 56.5 376.20 209000.00 3699.12
2 160 2.22 30.0 76.0 46.0 355.20 197333.33 4289.86
3 150 2.08 29.5 64.0 34.5 312.00 173333.33 5024.15
4 140 1.96 28.7 56.0 27.3 274.40 152444.44 5584.05
5 130 1.82 28.0 51.0 23.0 236.60 131444.44 5714.98
6 120 1.68 27.6 47.0 19.4 201.60 112000.00 5773.20
7 110 1.52 26.5 44.0 17.5 167.20 92888.89 5307.94
8 100 1.37 26.0 42.0 16.0 137.00 76111.11 4756.94
9 90 1.25 25.5 40.0 14.5 112.50 62500.00 4310.34
10 80 1.10 25.0 38.0 13.0 88.00 48888.89 3760.68
11 70 0.95 24.9 36.0 11.1 66.50 36944.44 3328.33
12 60 0.82 24.3 34.0 9.7 49.20 27333.33 2817.87
13 50 0.68 24.0 32.0 8.0 34.00 18888.89 2361.11
14 40 0.55 24.0 30.0 6.0 22.00 12222.22 2037.04
15 30 0.40 24.0 28.0 4.0 12.00 6666.67 1666.67
16 20 0.27 23.7 26.0 2.3 5.40 3000.00 1304.35
17 10 0.14 23.5 25.0 1.5 1.40 777.78 518.52
18 0 0.00 23.0 23.0 0.0 0.00 0.00 -

Condenser Condensing
No. P (kPa)
Tin (°C) Tout (°C) DT (°C) DTL (°C) Q (W) q (W/m2) h (W/m2-°C)
1 16.2 20.2 4.0 12.2 459.80 14368.75 1178.65 119.325
2 16.3 20.2 3.9 11.6 448.31 14009.53 1203.43 117.325
3 16.3 20.0 3.7 11.2 425.32 13291.09 1181.56 115.325
4 16.3 19.0 2.7 11.0 310.37 9698.91 882.14 113.325
5 16.1 18.5 2.4 10.7 275.88 8621.25 809.13 110.325
6 16.0 18.3 2.3 10.4 264.39 8262.03 793.84 106.325
7 15.5 17.5 2.0 10.0 229.90 7184.38 720.85 104.325
8 15.5 17.0 1.5 9.7 172.43 5388.28 553.74 101.325
9 15.5 16.7 1.2 9.4 137.94 4310.63 459.20 100.325
10 15.0 16.5 1.5 9.2 172.43 5388.28 583.80 98.325
11 15.0 16.2 1.2 9.3 137.94 4310.63 464.15 97.325
12 15.0 16.1 1.1 8.7 126.45 3951.41 452.19 96.325
13 15.0 16.0 1.0 8.5 114.95 3592.19 423.10 95.325
14 15.0 16.0 1.0 8.5 114.95 3592.19 423.10 95.325
15 15.0 16.0 1.0 8.5 114.95 3592.19 423.10 94.325
16 15.0 16.0 1.0 8.2 114.95 3592.19 438.62 93.825
17 15.0 15.5 0.5 8.2 57.48 1796.09 217.78 93.325
18 15.0 15.5 0.5 7.7 57.48 1796.09 231.83 92.325
ตารางที่ 3 บ ันทึกผลการทดลองของอ ัตราการไหลของนา้ 15 g/s
 เมือ ่ ความต่างศักย์ไฟฟ้ า
่ เพิม
Flow rate (measured): 0.0150 kg/s
Area of condenser : 0.0320 m2
Area of heater : 0.0018 m2
Heat capacity of water 4.1800 kJ/kg-°C

Boiling heat Boiling


No. V (Volt) I (A) Theater
Tliquid (°C) DT (°C) Q (W) q (W/m2) h (W/m2-°C)
(°C)
1 0 0.00 24.0 23.0 1.0 0.00 0.00 0.00
2 10 0.14 24.0 26.0 2.0 1.40 777.78 388.89
3 20 0.27 24.0 30.0 6.0 5.40 3000.00 500.00
4 30 0.41 24.5 33.0 8.5 12.30 6833.33 803.92
5 40 0.54 24.5 35.0 10.5 21.60 12000.00 1142.86
6 50 0.68 25.0 38.0 13.0 34.00 18888.89 1452.99
7 60 0.88 25.0 40.0 15.0 52.80 29333.33 1955.56
8 70 0.95 26.0 41.0 15.0 66.50 36944.44 2462.96
9 80 1.09 26.0 42.0 16.0 87.20 48444.44 3027.78
10 90 1.24 26.0 44.0 18.0 111.60 62000.00 3444.44
11 100 1.37 27.0 46.0 19.0 137.00 76111.11 4005.85
12 110 1.52 27.5 48.0 20.5 167.20 92888.89 4531.17
13 120 1.67 28.0 48.0 20.0 200.40 111333.33 5566.67
14 130 1.80 29.0 52.0 23.0 234.00 130000.00 5652.17
15 140 1.95 29.5 57.0 27.5 273.00 151666.67 5515.15
16 150 2.06 30.5 65.0 34.5 309.00 171666.67 4975.85
17 160 2.20 32.0 76.0 44.0 352.00 195555.56 4444.44
18 165 2.30 34.0 89.0 55.0 379.50 210833.33 3833.33

Condenser Condensing
No. 2 2 P (kPa)
Tin (°C) Tout (°C) DT (°C) DTL (°C) Q (W) q (W/m ) h (W/m -°C)
1 15.5 16.0 0.5 8.2 31.35 979.69 118.79 93.325
2 15.5 16.1 0.6 8.2 37.62 1175.63 143.43 94.325
3 15.5 16.2 0.7 8.1 43.89 1371.56 168.39 95.325
4 15.5 16.5 1.0 8.5 62.70 1959.38 230.78 96.325
5 15.5 16.5 1.0 8.5 62.70 1959.38 230.78 97.325
6 15.5 16.7 1.2 8.9 75.24 2351.25 264.59 98.325
7 15.5 17.0 1.5 8.7 94.05 2939.06 336.72 98.325
8 15.5 17.5 2.0 9.5 125.40 3918.75 414.03 100.325
9 15.5 18.0 2.5 9.2 156.75 4898.44 532.82 101.325
10 15.5 18.5 3.0 8.9 188.10 5878.13 659.28 102.825
11 15.5 19.0 3.5 9.6 219.45 6857.81 711.07 105.325
12 15.7 20.0 4.3 9.5 269.61 8425.31 887.98 108.325
13 15.7 20.0 4.3 10.0 269.61 8425.31 842.84 110.325
14 15.7 20.5 4.8 10.7 300.96 9405.00 877.21 111.325
15 15.7 21.3 5.6 10.8 351.12 10972.50 1019.92 114.325
16 16.0 22.5 6.5 10.9 407.55 12735.94 1165.25 121.325
17 16.0 24.5 8.5 11.2 532.95 16654.69 1484.59 129.325
18 16.5 26.5 10.0 11.8 627.00 19593.75 1660.17 134.325
ตารางที่ 4 บ ันทึกผลการทดลองของอ ัตราการไหลของนา้ 15 g/s
่ ลดความต่างศักย์ไฟฟ้ า
 เมือ
Flow rate (measured): 0.0150 kg/s
Area of condenser : 0.0320 m2
Area of heater : 0.0018 m2
Heat capacity of water 4.1800 kJ/kg-°C

Boiling heat Boiling


No. V (Volt) I (A) Theater
Tliquid (°C) DT (°C) Q (W) q (W/m2) h (W/m2-°C)
(°C)
1 165 2.30 34.0 89.0 55.0 379.50 210833.33 3833.33
2 160 2.23 34.0 80.0 46.0 356.80 198222.22 4309.18
3 150 2.06 31.0 65.0 34.0 309.00 171666.67 5049.02
4 140 1.95 30.0 58.0 28.0 273.00 151666.67 5416.67
5 130 1.80 29.0 53.0 24.0 234.00 130000.00 5416.67
6 120 1.65 28.0 48.0 20.0 198.00 110000.00 5500.00
7 110 1.50 27.5 45.0 17.5 165.00 91666.67 5238.10
8 100 1.37 27.0 42.0 15.0 137.00 76111.11 5074.07
9 90 1.24 26.5 40.0 13.5 111.60 62000.00 4592.59
10 80 1.10 26.0 38.0 12.0 88.00 48888.89 4074.07
11 70 0.95 25.5 36.0 10.5 66.50 36944.44 3518.52
12 60 0.82 25.0 34.0 9.0 49.20 27333.33 3037.04
13 50 0.67 25.0 33.0 8.0 33.50 18611.11 2326.39
14 40 0.55 24.0 31.0 7.0 22.00 12222.22 1746.03
15 30 0.41 24.0 29.0 5.0 12.30 6833.33 1366.67
16 20 0.28 24.0 27.0 3.0 5.60 3111.11 1037.04
17 10 0.14 24.0 25.0 1.0 1.40 777.78 777.78
18 0 0.00 24.0 23.0 1.0 0.00 0.00 0.00

Condenser Condensing
No. 2 2 P (kPa)
Tin (°C) Tout (°C) DT (°C) DTL (°C) Q (W) q (W/m ) h (W/m -°C)
1 16.5 26.5 10.0 11.8 627.00 19593.75 1660.17 134.325
2 16.5 26.5 10.0 11.8 627.00 19593.75 1660.17 136.325
3 16.5 23.0 6.5 10.9 407.55 12735.94 1165.25 124.325
4 16.5 22.5 6.0 10.2 376.20 11756.25 1151.69 120.325
5 16.5 21.5 5.0 9.8 313.50 9796.88 1000.90 117.325
6 16.0 20.5 4.5 9.6 282.15 8817.19 920.91 113.325
7 16.0 19.5 3.5 9.6 219.45 6857.81 711.07 107.125
8 15.5 19.0 3.5 9.6 219.45 6857.81 711.07 105.325
9 15.5 18.5 3.0 9.4 188.10 5878.13 623.97 102.325
10 15.5 18.0 2.5 9.2 156.75 4898.44 532.82 101.325
11 15.5 17.5 2.0 9.0 125.40 3918.75 437.22 100.325
12 15.5 17.0 1.5 8.7 94.05 2939.06 336.72 98.325
13 15.5 16.8 1.3 8.8 81.51 2547.19 288.34 97.325
14 15.5 16.5 1.0 8.0 62.70 1959.38 245.24 96.325
15 15.5 16.5 1.0 8.0 62.70 1959.38 245.24 96.325
16 15.5 16.2 0.7 8.1 43.89 1371.56 168.39 95.325
17 15.5 16.2 0.7 8.1 43.89 1371.56 168.39 94.325
18 15.5 16.0 0.5 8.2 31.35 979.69 118.79 93.325
บ ันทึกผลการทดลอง

125

120

115
q (W/m2)

110

105

100
0.0 10.0 20.0 30.0 40.0 50.0 60.0
DT (°C)

Increase voltage Decrease voltage

รูปที่ 2 ความสัมพันธ์ระหว่าง Pressure (kPa) กับ DT (°C) ทีอ


่ ต
ั ราการไหลของน้ า 27.5 g/s

140

135

130

125
q (W/m2)

120

115

110

105

100
0.0 10.0 20.0 30.0 40.0 50.0 60.0
DT (°C)

Increase voltage Decrease voltage

รูปที่ 3 ความสัมพันธ์ระหว่าง Pressure (kPa) กับ DT (°C) ทีอ


่ ต
ั ราการไหลของน้ า 15 g/s
1000000.00

100000.00
q (W/m2)

10000.00

1000.00

100.00
1.0 10.0 100.0
DT (°C)

Increase voltage Decrease voltage

รูปที่ 4 ความสัมพันธ์ระหว่าง Heat flux (W/m2) กับ DT (°C) ทีอ ั ราการไหลของน้ า 27.5 g/s ของ Boiling heat
่ ต

100000.00

10000.00
q (W/m2)

1000.00

100.00
0.1 1.0 10.0
DT (°C)

Increase voltage Decrease voltage

รูปที่ 5 ความสัมพันธ์ระหว่าง Heat flux (W/m2) กับ DT (°C) ทีอ


่ ต
ั ราการไหลของน้ า 27.5 g/s ของ Condenser
1000000.00

100000.00
q (W/m2)

10000.00

1000.00

100.00
1.0 10.0 100.0
DT (°C)

Increase voltage Decrease voltage

รูปที่ 6 ความสัมพันธ์ระหว่าง Heat flux (W/m2) กับ DT (°C) ทีอ ั ราการไหลของน้ า 15 g/s ของ Boiling heat
่ ต

100000.00

10000.00
q (W/m2)

1000.00

100.00
0.1 1.0 10.0 100.0
DT (°C)

Increase voltage Decrease voltage

รูปที่ 7 ความสัมพันธ์ระหว่าง Heat flux (W/m2) กับ DT (°C)ทีอ


่ ต
ั ราการไหลของน้ า 15 g/s ของ Condenser
10000.00
h (W/m2-°C)

1000.00

100.00
1.0 10.0 100.0
DT (°C)

Increase voltage Decrease voltage

รูปที่ 8 ความสมั พันธ์ระหว่าง Surface heat transfer coefficient (W/m2-°C) กับ DT (°C)
ทีอ่ ต
ั ราการไหลของน้ า 27.5 g/s ของ Boiling heat

10000.00
h (W/m2-°C)

1000.00

100.00
0.1 1.0 10.0
DT (°C)

Increase voltage Decrease voltage

รูปที่ 9 ความสมั พันธ์ระหว่าง Surface heat transfer coefficient (W/m2-°C) กับ DT (°C)
ทีอ่ ต
ั ราการไหลของน้ า 27.5 g/s ของ Condenser
10000.00
h (W/m2-°C)

1000.00

100.00
1.0 10.0 100.0
DT (°C)

Increase voltage Decrease voltage

รูปที่ 10 ความสมั พันธ์ระหว่าง Surface heat transfer coefficient (W/m2-°C) กับ DT (°C)
ทีอ่ ต
ั ราการไหลของน้ า 15 g/s ของ Boiling heat

10000.00
h (W/m2-°C)

1000.00

100.00
0.1 1.0 10.0 100.0
DT (°C)

Increase voltage Decrease voltage

รูปที่ 11 ความสมั พันธ์ระหว่าง Surface heat transfer coefficient (W/m2-°C) กับ DT (°C)
ทีอ่ ต
ั ราการไหลของน้ า 15 g/s ของ Condenser