You are on page 1of 1

This list only contains alarm and shutdown list suitable for process operator to monitor and alert

of EGC
Check by: Dat-EI Date: 31March2023

LUBE
TAG DESCRIPTION ALARM S/D UNITS NOTE
RT327-1 Brg1 Drain Temp Hdr Temp +25 - DegC
RT327-2 Brg2/3 Drain Temp Hdr Temp +61 Hdr Temp+69 DegC
RT327-4 Brg4/5 Drain temp Hdr Temp +25 - DegC
RT380 Lube Oil Header Temp 43 Low Alarm 74 High DegC
68 High - DegC
TL388 Lube Oil Tank Level 43.2 Low 40.6 Low cm
55.9 High - cm
TP380 Lube Oil Hdr. Pr. 1.86 Low 1.03 or 1.72 Delay 5 Sec Barg upto 70.637% NGP
1.86 Low 1.72 Low Barg Above 70.637% NGP
TPD324 Lube Oil Tank Vent Pr. 0.586 High 0.689 High Bard
TPD397 Lube Oil Filter 2.07 High Bard

Fuel
TAG DESCRIPTION ALARM S/D UNITS NOTE
RT389 Gas Fuel Temp. 85 Delay 10 Sec High 96 Delay 120 Sec DegC
or 121 Delay 0.1 Sec
TP342-1 Gas Valve Check 27.58 27.92 Barg
TP386 Gas Fuel Pr. 27.58 27.92 Barg
TP341 Instrument Air Pr. 5.5 - Barg
TP389 Fuel Control Upstream Pr. 27.58 27.92 Barg
T5 Temperature Delayed AL/SD >765.5 Delay 10Sec >765.5 Delay 20Sec DegC SetPoint-765.5
T5 Temp. Inst. S/D - 815.5 DegC
T5 Temp. Single Sensor High - 982 DegC
T5 Single T5 Sensor Higher than Avg 93.3 Delay 5 Sec - DegC
Ngp Over Speed - 102.5 % 100 % Speed=15200rpm
Ngp Under Speed - 76 % 20 Sec Delay Arm after Starter dropout
Ngp Back-Up Overspeed - 108 %
Ngp Failed to accelerate - <70 % 420 sec delay after ignition
Npt OverSpeed - 105 % 100 % Speed=12000rpm
Npt Under Speed - 42 % During running or When Compressor Unloaded
Npt Fail To Breakaway - 5 % At Ngp 65%
EGF388 Gas Fuel Valve FB Pos. Fail 10 % 2 Sec Delay 10% difference between Cmd & FB

Temperature/Vibration Compressor Turbine


TAG DESCRIPTION ALARM S/D UNITS NOTE
TV360Y/X HP Cmpr. Fwd Y & X axis 50.8 63.5 Micron
TV361Y/X HP Cmpr. Aft Y & X axis 50.8 63.5 Micron
TV360Z HP Cmpr. Axial +/-0.305 +/-0.432 mm
RT370-4 HP Compressor OutBrd. Thrust 121.1 126.6 DegC
RT370-5 HP Compressor InBrd. Thrust 121.1 126.6 DegC
RT370-6 HP Compressor Suction Jrnl. Brg 115.6 121.1 DegC
RT370-7 HP Compressor Disch. Jrnl. Brg 115.6 121.1 DegC

TV351Y/X GP Brg1 63.5 101.6 Micron


TV352Y/X GP Brg2 63.5 101.6 Micron
TV353Y/X GP Brg3 63.5 101.6 Micron
TV351Z GP axial +0.102/-0.508 +0.178/-0.584 mm

TV354Y/X PT Brg4 63.5 101.6 Micron


TV355Y/X PT Brg5 63.5 101.6 Micron
TV355Z PT axial +0.102/-0.508 +0.178/-0.584 mm
TV3501 Accessory Gear ox 5.08 7.11 mm/sec rms

Seal
TAG DESCRIPTION ALARM S/D UNITS NOTE
RT370 HPC seal gas Temperature Low 29 DegC
TIT207 Seal Gas Htr. Outlet temp. Low 115 and RT370 < 40.5 82 and RT370 < 35 DegC
Seal Gas Htr. Outlet temp.High 130 135 DegC
TP385-1 HPC Disch. Primary Seal Vent 0.55 1.38 Barg
TP385-4 HPC Suc. Primary Seal Vent 0.55 1.38 Barg
TPD379-1 HPC Seal Filter DP 1.37 Delay 10 Sec - Bard
TPD372 HPC Buffer air Filter DP 2.06 - Bard
TPD383-1 HPC Buffer air DP Low 1.52 1.38 Bard
HPC Buffer air DP High 2.41 - Bard
TPD346-1 HPC seal as DP low 0.48 0.276 Bard
S391-1 HPC Secondary Seal Flow High 0.13 0.13 nm3/min Activate SD when start up and alarm only when running

Enclosure ,Fire & Gas


TAG DESCRIPTION ALARM S/D UNITS NOTE
S799A/B Air Inlet Filter DP 5 7 inH20
RT396 Enclosure Tempr. 75 85 DegC
TPD396-2 Enclosure Pressure 0.25 0.15 Delay 90 Sec inH20 If Fire system Inhibit only alarm
Any Two UV Flame detector Fire detect SD
Any One Gas Detector High 15 % LEL Start Permissive
Any One Gas Detector High High 40 % LEL Shut down with Enclosure fan running
Any One thermal heat detector high Trip Fire detect SD
UCP 24V Dc 24 Vdc Low 21.5 21 Vdc
25 Vdc High 32 Vdc
Process
TAG DESCRIPTION ALARM S/D UNITS NOTE
TP363-1 Compr. Suction Pr. 66.88 Low 63.43 Barg Shutdown by Pr. Sw. S363-1
TP364-1 Compr. Disch. Pr. 168.23 High 176.5 High Barg Shutdown by Pr. Sw. S364-1
RTD364-1 Compr. Disch. temp. 115.55 High not avail. Deg C