GE Vivid 7 Quickstart Reference Guide
System overview
Display Monitor:
Swivels to the left and right, tilts up and down.
Speakers
Source: GE Vivid 7 Manual, Copyright 2011GE Vivid 7 Quickstart Reference Guide
Svstem overview
Legend
Control panel:
Contains all the buttons and the alphanumeric
keyboard used to operate the system.
Probe and gel holders:
Situated on either side of the Control panel.
Qa
oo. GS]
too COOAG 888,
VCR
Probe ports:
Three active and one park phased array
probe ports, and two pencil probe ports.
Foot brakes:
Control swivel and brake of the wheels. See
page 19 for further details.
CD-RW is not
‘supported, only
CD-R
(recordable).
Portable disks:
+ Magneto optical disk
+ CD-ROM
Patient /0
Black & white video printer
Console swivel operating handle:
Situated in the middle beneath the front
handles.
+ Vivid 7 Dimension: swivel and in/out
displacement
+ Vivid 7 PRO: limited swivel only
Source: GE Vivid 7 Manual, Copyright 2011GE Vivid 7 Quickstart Reference Guide
Control The following pictures illustrate the layout of the Vivid 7 control
panel panel. The buttons and controls are grouped together for ease
of use.
Left Side Control Panel
Source: GE Vivid 7 Manual, Copyright 2011
eo Repe
|. TGC sliders
. Loudspeaker volume control
On/Off button
Protocol in/out
|. Navigation keys: Archiving &
Reporting buttons Pre-examination
buttons Video playback
. Function keys:
+ On-line manual
+ System Configuration
+ Annotations
+ Body marks
+ DICOM spooler
. Alphanumeric keyboard
|. 4D mode (Vivid 7 Dimension only)
|. Multi-plane mode (Vivid 7 Dimension
only)GE Vivid 7 Quickstart Reference Guide
Control The following pictures illustrate the layout of the Vivid 7 control
panel panel. The buttons and controls are grouped together for ease
of use.
10. Active mode gain
14, 2D gain
12, Scan mode selection keys
13. Assignable keys
14, Zoom control
1. Depth control
16. Display format keys
17, Measurement, Image store and
menu keys
18. Soft menu rocker
19. VCR controls and print keys
20. Freeze keys
24, Trackball operation
Right Side Control Panel
Source: GE Vivid 7 Manual, Copyright 2011GE Vivid 7 Quickstart Reference Guide
Power On/Off key
Description
Turns the unit on and off.
Navigation keys
Description
Displays the Search/Create patient window.
Enables the creation of a new patient record.
Displays the Select Probe and Application dialog
box that enables the users to select the desired
probe and application preset for the current
examination.
Displays the Application dialog box that enables
the users to select the appropriate application
preset for the current examination.
Gives access to controls for physiological traces.
The controls appear on the assignable keys.
Displays the examination report.
Source: GE Vivid 7 Manual, Copyright 2011GE Vivid 7 Quickstart Reference Guide
Navigation keys
Description
Brings the scanner into the Image review mode,
that enables the user to select images from the
clipboard for analysis, activate the image
browser or enter the Image Review screen
where bigger previews of the images are shown
for image selection.
Displays the Search/Create patient window if no
patient record is currently selected. Enables the
user to search a patient record in a patient
archive.
Displays the Measurement worksheet where the
user may edit or delete measurements, change
averaging etc.
Brings scanner into video playback mode that
enables the user to look at video tape
recordings.
Source: GE Vivid 7 Manual, Copyright 2011GE Vivid 7 Quickstart Reference Guide
Scan Mode The following keys are used to select the required scan mode,
Selection keys and to select additional tools that enhance the application's
capabilities.
Key Description
Displays the 2D live acquisition mode that is the
default scanning screen for the unit.
M-Mode can be
added from a 2D
scan also in
replay.
Displays the M-Mode examination screen and
enables M-Mode functions. Used for viewing
motion patterns.
Displays the examination screen in Color Flow
Mapping mode. Used to display color-coded
blood flow information.
In replay mode Displays the examination screen in Pulsed Wave
with TV! the Doppler mode. Used for displaying the Doppler
velocity trace spectrum of blood flow at a selected part of the
mode will be anatomy.
toggled on by the
PW key.
CW mode is not Displays the examination screen in Continuous
available on all
scanning probes.
Wave Doppler mode. Allows examination of
blood flow data all along the Doppler CW cursor.
Displays the tissue velocity overlay on 2D and
M-Mode scans. If TVI is on, the Doppler modes
(PWICW) will also be optimized for tissue
velocity.
Depending on the options installed on the
scanner, this key will bring up the menu for
selection of additional scanning modes.
Source: GE Vivid 7 Manual, Copyright 2011GE Vivid 7 Quickstart Reference Guide
Basic Mode Parameter Adjustment Controls
The following controls are used to modify and adjust the unit's
display to best suit the user’s requirements, such as color, gain,
zoom and image depth, according to the mode being operated
by the user.
Controls Description
2D Gain Controls the total gain of the gray scale images
et in 2D Mode.
Active mode Controls the total gain of other activated modes,
Gain such as, M-Mode. Color, PW, or CW Doppler
mode.
Ss
Tec Sliding keys that compensate for depth-related
7 attenuation in an image. The upper slider
ir corresponds to the smallest depth.
Depth Controls the displayed depth of tissue scan. Has
-O
no effect in replay.
Toggles the cursor display on/off in 2D scanning
mode.
Changes the Doppler ultrasound beam angle on
linear probes. The steering angles are fixed for
each linear probe. This key has no effect with
sector imaging probes.
Source: GE Vivid 7 Manual, Copyright 2011GE Vivid 7 Quickstart Reference Guide
Basic Mode Parameter Adjustment Controls
The following controls are used to modify and adjust the unit's
display to best suit the user’s requirements, such as color, gain,
zoom and image depth, according to the mode being operated
by the user.
Controls
Description
Toggles the high resolution (HR) 200m on/off.
The key has no effect in replay. The HR zoom
concentrates the image processing to a user
selectable portion of the image, resulting in an
improved image quality and a higher frame rate
in the chosen RO!
Controls image magnification. Rotate clockwise
to activate zoom mode and increase zoom
factor. Rotate counterclockwise to decrease and
turn off zoom. Zoom is available in both live and
replay.
Freeze keys
The freeze keys are used to freeze images and cine loops in all
modes for on-line analysis and storage for future use.
Key
Description
Stops or restarts all data acquisition. When scan
is frozen, the Trackball can be used to scroll
through the cine loop.
Activates or freezes 2D mode. In simultaneous
mode, pressing 2D FREEZE will activate or
deactivate the 2D image, leaving the other mode
display unchanged. In freeze mode, stops/starts
the cineloop.
Source: GE Vivid 7 Manual, Copyright 2011GE Vivid 7 Quickstart Reference Guide
Display format keys
The following keys provide different view formats to best suit
the user's requirements.
Key
Description
Toggles the display priority of 2D-Mode or
Doppler/M-Mode and top/bottom or side by side
display when working in combined mode.
Enables multiple image display windows in
which two or four images can be viewed
simultaneously. When reducing the number of
images, the active window will always been kept.
In combined mode, switches between the mode
specific assignable controls of the currently used
modes.
Toggles the active window in multiple imaging
mode. The active window is indicated by a
highlighted frame. All imaging controls are
normally applied only to the active window.
Measurement controls
The following keys are used to take measurements and
perform calculations.
Key
Description
Activates the Measurement & Analysis (M&A)
calculation program. This program is context
sensitive and will display relevant measurements:
to the current mode and application.
Activates measurement tools (unassigned
measurement).
Source: GE Vivid 7 Manual, Copyright 2011GE Vivid 7 Quickstart Reference Guide
Clear, Menu, and Image Store keys
Key
Description
Used for navigation between menus and
screens. CLEAR brings the display back to the
previous state.
Activates menu with additional options and
controls not available from the assignable keys.
Stores the currently active imaging window to
disk. The stored information depends of the
configuration of the current application. Stored
images are shown on the clipboard.
VCR Control
and Print key
Key
Description
Rec/Pause
Toggles the VCR to Record or Pause. For further
information about using VCR,
Prints the current imaging screen content to a
selected (configurable) printer. For more
information about printing.
The PRINT key can also be configured for
alternative storing of images.
Prints the current imaging screen content to a
printer assigned to a second port (configurable).
The ALT key can also be configured
for alternative storing of images.
Source: GE Vivid 7 Manual, Copyright 2011GE Vivid 7 Quickstart Reference Guide
Trackball operation
The Trackball area consists of the trackball and five
surrounding keys. Three of these have the very same function
Key
Description
Trackball
Used for navigation and together with the
surrounding keys, to move, select or activate
objects on the screen.
SF
Trackball key | Toggles between the trackball functional groups
Select Depending on the situation:
So + Performs the selected control or highlighted
menu item.
+ Toggles between the Trackball functions within
the active group.
The key is duplicated for ergonomic reasons.
Update Menu
9
In live mode, toggles between 2D imaging and
live time-motion imaging (Doppler/M-Mode). in
freeze, displays the function-specific menu
(same function as MENU )-
Source: GE Vivid 7 Manual, Copyright 2011GE Vivid 7 Quickstart Reference Guide
Assignable keys and rotary knobs
The functions of the assignable keys vary according to the
mode and/or module in which the user is working.
Key
Description
Assignable
rotary knobs
oll
Four rotary knobs, whose functions vary
according to the scan mode and position that is
currently active. The assigned functions are
indicated above the rotary on the LCD display.
Assignable
Buttons
[ol |
Five buttons, whose functions vary according to
the scan mode and position that is currently
active. The assigned functions are indicated
above the button on the LCD display
Gives access to additional controls trom the
assignable buttons.
The soft menu rocker
Key Description
Soft Menu
Rocker A 4-way rocker used to access mode-specific
menus, select a menu option and adjust
option-related values.
+ The vertical arrows are used to select the menu
options.
+ The horizontal arrows are used to adjust the
values.
Source: GE Vivid 7 Manual, Copyright 2011GE Vivid 7 Quickstart Reference Guide
The 4D and Mu
plane keys
Description
‘Starts the 4D application (probe dependent),
Vivid 7 Dimension only.
Starts the Multi-piane application (probe
dependent), Vivid 7 Dimension only.
The alphanumeric keyboard
a
ey
Description
Fi
Displays the on-line version of the user manual.
Displays the configuration dialog box, allowing
user configuration of various settings on the
scanner. Some settings are configured for each
application, press APPL. to access to
application-specific settings.
Displays the DICOM spooler window. The
DICOM spooler is used for checking the current
job's status when a job is saved or when the total
‘spooler status on the right of the Archive
windows displays an error.
F6
Displays the available body marks for the current
application.
FT
pv
Erases all previously typed annotations (and
body marks.
Source: GE Vivid 7 Manual, Copyright 2011GE Vivid 7 Quickstart Reference Guide
The alphanumeric keyboard
Key Descri
Activates a cursor for selection of a single
i annotation to be deleted from an image.
SJ
= Displays an arrow that can be used to point at a
Fo specific structure in the image.
s)
Enables text annotation to be inserted on the
image in two layers.
Inserts predefined annotation on the image.
Source: GE Vivid 7 Manual, Copyright 2011