You are on page 1of 1

PRELIMINARY CALCULATION FOR PILE CAPACITY DATE 26-Jul-23

Project : PROPOSE RC PILE FOUNDATION Calculated by: Ir Dr Ramli


Structure :
Borehole No.: BH5 Concrete Class (MS or C): MS
Ground Level RL + 89.125 m Concrete Grade: 45 N/mm2 Correlation for Cu (kPa): (2/3)10 * SPT-N 6.6666667
GWT RL + Nil m Pile X-Sectional Area: 0.063 m2 Unit shaft friction (sand): 2 * SPT-N
Platform Level RL + 81 m Structural Capacity: 784 kN End bearing (sand): 400 * SPT-N
CUT -8.125 m 70% of Struct Cap: 549 kN Adhesion a for driven pile in clay (API method):
Pile Size (dia.): 250 mm Partial Safety Factor for Shaft Friction, Fps 2.0 = 1.0 for cu<25kPa
Type of pile: RC Partial Safety Factor for End Bearing, Fpb 3.0 = 0.5 for cu>70kPa
Shape of pile: Square Global Safety Factor,F 2.0 = 1.0-0.5(cu-25)/50 for 25<cu<70kPa
Asc : 78.54 mm 2
fs limit = 150kPa
fsc: 175 N/mm2 fb limit = 10000kPa

Soil SPTave Frictional Resistance End Bearing Negative


Description Depth SPT for end Adhesion Skin
c-clay,s-sand (m) bearing cu factor fs Qs sum(Qs) fbu Qp (Qns)
r-rock (kPa) a (kPa) (kN) (kN) (kPa) (kN)
C 0 - 1.5 5 5 33 0.9 30.6 45.8 45.8 300 18.8
S 1.50 - 3.00 5 5 - - 10.0 15.0 60.8 2000 125.0
S 3.00 - 4.50 6 5.5 - - 12.0 18.0 78.8 2200 137.5
S 4.50 - 6.00 7 9.75 - - 14.0 21.0 99.8 3900 243.8
S 6.00 - 7.50 9 12.25 - - 18.0 27.0 126.8 4900 306.3
C 7.50 - 9.00 10 14 67 0.6 38.9 58.3 185.2 600 37.5
S 9.00 - 10.50 11 15.75 - - 22.0 33.0 218.2 6300 393.8
S 10.50 - 12.00 7 12.25 - - 14.0 21.0 239.2 4900 306.3
S 12.00 - 13.50 9 13.5 - - 18.0 27.0 266.2 5400 337.5
S 13.50 - 15.00 18 22 - - 36.0 54.0 320.2 8800 550.0
C 15.00 - 16.50 23 29.75 153 0.5 76.7 115.0 435.2 1380 86.3
C 16.50 - 18.00 52 62.25 347 0.5 173.3 260.0 695.2 3120 195.0
C 18.00 - 19.50 100 118.75 667 0.5 333.3 500.0 1195.2 6000 375.0
C 19.50 - 21.00 100 138 667 0.5 333.3 500.0 1695.2 6000 375.0
C 21.00 - 22.50 214 264 1427 0.5 150.0 225.0 1920.2 12840 802.5
C 22.50 - 24.00 300 378.5 2000 0.5 150.0 225.0 2145.2 18000 1125.0

Note : SPTave = Average SPT 10D above and 4D below the pile point
Allowable Geotechnical Capacity(Partial FOS) 246.3 kN
Allowable Geotechnical Capacity(Global FOS) 260.7 kN
PILE LENGTH = 18 m
Allowable Geotechnical Pile Capacity 246.3 kN PILE CAPACITY = 24.6 TON