You are on page 1of 5
MITSUBISHI ELECTRIC Changes for the Better PUERTO LIBERTADOR CORDOBA-COLOMBIA fo eee GECELCA3 POWER PLANT OPERATION DATA ANALYSIS ae REPORT (SUMMARY) COMPANY PROPRIETARY NOT TO BE REPRODUCED OR DISCLOSED WITHOUT SPECIFIC WRITTEN PERMISSION OF MITSUBISHI ELECTRIC CORPORATION al V|DATE [REVISED [CHECKED [APPROVED] DISCRIPTION REMARKS, DRAWN ‘CHECKED "APPROVED DWGNo ENERGY SYSTEMS CENTER GENERATOR DEPARTMENT QUALITY ASSURANCE SECTION ART-T-12608 MITSUBISHI ELECTRIC CORPORATION as) 4. RATING Aor To a remomeeno& o1scss Teh PEBSION OF MITSUISH ELECTRIC COROT Changes for the Better TURBINE GENERATOR NOMINAL CAPACITY ‘TERMINAL VOLTAGE LINE CURRENT POWER FACTOR No. OF PHASE FREQUENCY RATED SPEED THERMAL INS, CLASS 60. 3600 F (155°C Rise) ART-1-12608 (2/5) are names or ate HERBS Changes for the Better 2. THE RESULT OF OPERATION DATA ANALYSIS. Attachment-1 shows operation condition of maximum value every month from Nov-18 to Nov-19, The evaluation of main monitored items are shown in Table-1 Table-1 Evaluation of main monitored item: Evaluation INo remarkable change was observed, jenerator stator col temperatures are good condilian because no remarkable change was observed and their temperatures are within criteria, jenerator Stator core Temperatures are good condilion Because nO ISTATOR CORE TEMP. remarkable change was observed and their temperatures are within criteria, [AIR TEMP, No remarkable change was observed. tbrormal condifon was confimed Th DOaTng Metal Temperature (T-side) on Nov-19. Please confirm detector condition and eee een. measurement circuit of bearing metal temperature because bearing rain was soundness Bearing cain of lenteraarer are good conation because To RG. DRAIN OIL TEMP. remarkable change was observed and thelr temperatures are within eter AFT VIBRATION Ik igh baton Value was cbssrvee a han Walon No.6 on SepTE JAT RATED SPEED(#5.#6) _|compare to other manth. However, this vibration is within criteria, ERG STAL Mise Vibration values are low and stable. 3.Conclusion We confirmed that all value were within criteria and soundness. However, it was observed following concerns. please investigate for warm air temperature and provide vibration data for detailed analysis. + Fluctuation of Warm air temperature, Bearing metal temperature No.6 and Bearing drain oil temperature No.6 were observed previous report Please confirm each detector condition and circuit, + Relatively high vibration value on No.6 shaft was observed after synchronize, it tends to decrease. immediately on Oct. 2019. We need the data of the vibration analyzer for detailed analysis, RI=T=12608 (3/5) Attachment=1(1/2) PUERTO LIBERTADOR CORDOBA-COLOMBIA GECELGAS POWER PLANT ‘TURBINE GENERATOR OPERATION CONDITION Nort@ Droit Mari8 Mori Aert8 Way-1D GurrIO GurIAUIB Gap-3 Oct-18 Nov-19 (GY GENERATOR OUTPUT sf Eso - : t i +t | | Mat Mari Apri® Moy19 dun-IO dui AwI8 ST Ost-19 Norl® (® GENERATOR FIELD CURRENT AND GENERATOR FIELD VOLTAGE » eS ay = ee oot Desmd—Jari8Mar-10 Marl Ape19May-19 ur Aue 18 Gari GeRTBNov-18 (@) STATOR COIL TENPERATURE 3 Be z : go = =r = a Bn See SEAgeee | SatSeaie ° Novi@ Dee-I8 Dec-IB _Jan-i8\Mar-18_Mor-I9__Ap1o__My-19_an-i_ aul ul Semele Ost-18Nev18 (@) STATOR CORE TEMPERATURE 00 Scarce RTE a an LD A Ta —— cen NorI8 Deo=1@ Deo-i8 Jari MariB Mai®Aei8 Mayt@ dol (GAR TENPERATURE re eS ART-1-12608 cas) Bl 10BA-COLOMEL ‘TURBINE GENERATOR OPERATION CONDITION ‘Attachment—1(2/2) aoe RS" Ghanges ore LANT | o SF METAL TEMP rade) _— BRO NETAL TONP(G-va)_—Ca or ORGNETAL TEMP Rose ara nee ene ale ee Mc Nene ipo p meaenet ; TT NERATORER ETAL TSOP : 4 aa a a ge 8 wo F ee GTR TORERG RAN OL TEES £ 10 2 « jo i : het ped tot ae te Wel et mre oe AD Ae Se Ow are Sra ERO sie eS pe 3 0 & go i ; 2 ul : eer saa We Og OR Sana es a TN aavie (5/5)

You might also like