pT re Jinhuimo Technology Co.,Ltd
Qingdao Jinhuimo International Trading Co.,Ltd
‘Stock code: 831623
SOLUTION PROPOSAL
(50M3/day)Qingdao Jinhuimo International Trading Co.,Ltd
pu nr Jinhuimo Technology Co.,Ltd
‘Stock code: 831623
Contact information
Seller info: Buyer info:
Name Jack Name | amra yacine
Email ‘Jack@jinhuimouf.com Email ‘amrayacine@livecom
Mobile “+86 18210208702 Mobile
Country | China mainiana Country | Algeria
Date: 3*Feb,2023
1.Project design basis
1.4 Capacity:
The total water capacity of sewage treatment system is 50m*/d
4.2 Water parameters
Water type : Domestic waste water and cleaning waste water
1.2.2 Output water quailty table
1.3 Power supply
according to our system capacity, parly a is responsible.
Power supply voltage:single phase 220V,
Three-phase 380V,
power frequency: 50Hz2. Process flow
2.1 PID is attached
2.2 Layout drawing is attached
Septic-tank
Equalization tank
Anoxic tank
Nitrification
reflux
Phosphorus
removal
Disinfection device
Water outlet
pT re Jinhuimo Technology Co.,Ltd
Qingdao Jinhuimo International Trading Co.,Ltd
‘Stock code: 831623
returnpT re Jinhuimo Technology Co.,Ltd
Qingdao Jinhuimo International Trading Co.,Ltd
‘Stock code: 831623
3 .The projcet investion buget
3.1 Sewage Treatment
‘At present, some experience has been accumulated in hospital sewage treatment process
at home and abroad. In view ofthe characteristics of domestic sewage, the main
technology is mainly biochemical, assisted by cerlain physical and chemical methods.
Such as biological contact oxidation (biological rotary table, SBR), coagulation
precipitation, air flotation. fitration, carbon adsorption, etc. The process of this project
adopts hydrolysis + contact oxidation + precipitation + disinfection.
3.2 Process flow
Because the discharge sewage is domestic sewage, its organic matter concentration is
low, the water quality indexis more stable, the biodegradability is better. Therefore, a
mature bioflm wastewater treatment process is adopted. In view of the characteristics of
hospital sewage. the design fuly consider the killing of bacteria in hospital sewage.
disinfection disinfectant with excellent bactericidal effect of chlorine dioxide.
3.3 Process specification
Pretreatment
@ Grille
It is used to intercept large floating objectsin sewage, to ensure the normal operation of
subsequent treatment structures and reduce the treatment load. and to ensure the
long-term normal operation of the system. The grid design specification is B=500mm
@ Equalization tank
Due to ine airferentwater quality and quantity rom each time, the general peak flow Is 2-8
times ofthe average treatment capacity, so in order to make the sewage treatment system
Tun continuously and stably, and the concentration of sewage can be adjusted, so the
design of an adjustment pool. The designed effective volume of the regulating tank is
usually 4-8 times ofthe average treatment capacity. The built-in submersible sewage
lifting pump and backflow measures ensure that a certain rated flow rate can be raised to
the sewage treatment equipment. WA series sewage pump is used for submersible
sewage pump. The pump is an underwater submersible pump with no blockage, long
service life and low energy consumption. The designed hydraulic retention time of the
regulating pool is 10 hours, and the material is concrete structure.
secondary treatment
Anoxic tank
The main function of hydrolytic acidification tank is to effectively remove organic
Components in sewage and further reduce the load of contact oxidation tank. Equipped
with combined packing, and the tank for periocic intermittent aeration,®shandong Jinhuimo Technology Co.,Ltd
Ly
md aft Qingdao Jinhuimo International Trading Co.,Ltd
‘Stock code: 831623
@ Aerobictank
Aerobic biological contact oxidation is one of the mature and commonly used aerobic
biological treatment technologies. The combined elastic fer is set in the pool, the specific
surface area of the filler is 280m2/m3, and the flow characteristics are very stable, easy to
hang the film, is the best place for biofilm growth. The aerobic biological contact oxidation
tank adopts the propulsion aeration method, and the wastewater in the biochemical tank is,
constantly in contact with the dissolved oxygen in the water and constantly advancing, so
as to fully make the bioflm on the filerand the organic matterin the sewage get full
contact degradation.
‘The design residence time of the aerobic biological contact oxidation tank is 6 hours, the
gas-water ratio is 20:1, and the aeratoris a diaphragm rubber aerator. The aerator has the
advantages of uniform air distribution, long service lite, high utilization rate of oxygen and
convenient disassembly.
‘@ Sedimentation tank
‘The effluent from the aerobic biological contact oxidation tank flows into the secondary
sedimentation tank for precipitation treatment to precipitate the shed biofilm and inorganic
small parties. The sedimentation tank is designed for vertical flow sedimentation tank.
‘The upper part ortne sedimentation tank Is an overflow tank, the midale part is a
sedimentation area, and the lower partis a sludge hopper. The precipitated water enters
the contact disinfection tank through the overflow tank, and the preciptated sludge is
regularly discharged tothe sludge tank for digestion and disin‘ection treatment.
‘ Clean water tank
‘The effluent from the sedimentation tank enters the contact disinfection tank. in orderto
ensure that the sewage meets the discharge siancard after treatment, It must be
disinfected by chlorine dioxide and eliminate harmful bacteria. The disinfectant is chlorine
dioxide, and the output of chlorine dioxide is 190g.
4. Design parameters of equipment
Pretreatment
¢ Grille
Rules: B= 500mm
Installation Angie: 600
‘Quantity: 1 set
Bocy material: carbon steel
‘@ Equalization tank
Capacity: 50T/D
Material: concrete mix®shandong Jinhuimo Technology Co.,Ltd
Ly
md aft Qingdao Jinhuimo International Trading Co.,Ltd
‘Stock code: 831623
level controller
‘Type: float ball type level controller
Model number: KEY-10
‘Quantity: 2 sets
Measuring depth: 0-5.0m
@Feedng pump
Type no. Wa6-16-0.75
‘Type: submersible sewage pump
Installation postion: inside the sewage regulating tank
Unit: 2 sets (1 for 1 spare)
Flow material: cast steel
Traffic: @ = 50 vD
1 secondary treatment
@ Anoxic tank
Material: carbon steel
Packing specification: biological combination packing
Packing material: Tsuen silk
Aeration main pipe: DNSO
Microporous aerator: rubber aerator head
@ Aerobictank
Material: carbon steel
Packing specification: biological combination packing
Packing material: Tsuen silk
Aeration main pipe: DN150
Microporous aerator: rubber aerator head
‘@ Sedimentation tank
Structure: vertical flow
Material: carbon steel
sludge retum pump
Type no. WQ6-10-0.75
‘Type: submersible sewage pump
Installation postion in the sludge tank
Quantity: 1 set
Flow material: cast steel
vertical water distributor
Type no. : DN125
Quantity: 4 set®shandong Jinhuimo Technology Co.,Ltd
Ly
md aft Qingdao Jinhuimo International Trading Co.,Ltd
‘Stock code: 831623
@ Clean water tank
Residence time: 21 hour
Quantity: 1 set
Material: carbon steel anti-corrosion
Disinfection form: chlorine dioxide disinfection
@ Equipments room
Contact oxidation tank blower
Model specification: GHBH1D7 342R4
Number: 2 sets (1 for use and 1 for standby, alternate use and each other for standby)
Manufacturer: Ruljing
®chiorine dioxide generator
Model number: 20-60
Chiorine production: Q=50g/h
Quantity: 4 set
Manufacturer: self-made by our factory
@Biectric control system
5.Process characte!
‘* This process adopts the conventional anoxia + aerobic + precipitation + sand fiter
carbon filter + disinfection combined method, the processis mature and reliable.
In the process, the sludge precipitated from the sedimentation tank is carried to the
aciaizing sedimentation tank Tor re-agestion treatment, so the amount of residual
sludge in the system is small.
‘* By adopting the contact oxidation treatment process which mainly removes organic
pollutants, the removal rate of pollutants can be improved to ensure effluent discharge
up to standard. Moreover, nh3-N can be transformed while removing organic pollutants
due to the extension of contact oxidation time.
‘* Sewage treatment system hes real-time water quality monitoring system, including flow
rate, pH value, in order to timely monitor water quality, adjust the operating status of
equipment.
* Preparation of chiorine dioxide wastewater disin‘ection with chlorine dioxide generator,
ZQ series water-cooled chionne dioxide generator as the standard chlorine dioxide
generator, is developed for the pharmaceutical, food, chemical industry and so on the
latest generation of chlorine dioxide generator, USES the international most advanced®$handong Jinhuimo Technology Co.,Ltd
Ly
md aft Qingdao Jinhuimo International Trading Co.,Ltd
Stock code: 831623,
technology, has the advantages of efficient, integrated and complete contra functions,
¢ The processing system is modular, and the constructionis simple and convenient.
6.Noise, Anti-corrosion
@ Noise
In the wastewater treatment system, thenoise sources are mainly water pumps and
fans. For this reason, we use low noise water pumps and fans in the design and
selection, while adding damping pads during installation, so as to reduce noise sources.
Anti-corrosion
The main equipment of the system is made of Q235A steel anticorrosive
material
7.The projcet investion buget
7.1 Equipment and civil engineering work
No Project Volume