GET STARTED WITH WinKFP 5.

1. Install WinKFP
2. After installation we get some directories:

After installation the directory (Drive letter):\EC-APPS\NFS\SGDAT contains file


CABI.h only, and doesn’t contains files, required for working.
3. Mount the Progman disk in virtual drive (or insert in usual DVD-drive), extract all files
SP-daten-Exx.rar from directory (Drive letter):\CIP-Installer\bin, each one in its own
directory. (You must get directories like SP-daten-Exx)
4. Now copy all *.IPO files from every directory (Drive letter):\SP-daten-Exx\sgdat to
directory (Drive letter):\EC-APPS\NFS\SGDAT. For this purpose better use Total
Commander, it allows to overwrite elder files with newest.
This directory now looks like this:

5. In the same way refresh directory (Drive letter):\EDIABAS\Ecu with files taken from
(Drive letter):\SP-daten-Exx\ecu
6. Run WinKFP
7. Choose “Import/Export – Import – Assemly line data” and import all data needed from
directories (Drive letter):\SD-daten-Exx\DATA
Details how to import assembly line data are given in official manual for WinKFP
8. After importing the data, copy all files from directory (Drive letter):\SD-daten-
E70\DATA\gdaten to directory (Drive letter):\EC-APPS\NFS\DATA\GDATEN,
overwriting all existing files.

Note: If you use Progman v.30 for updating WinKFP, it has error in file
\GDATEN\Sgidc.as2. Simply open this file with Notepad and delete line 165.

WinKFP is ready for programming