Equipment Calibrations

OSD-T-4009-B
Calibrations

 Gyrocompass Calibration

 DGPS Verification

 DGPS Comparison

 Motion Sensor Calibrations

 Offset Measurements

www.fugro.com
Gyro Calibrations

 Gyro Calibration presentation

www.fugro.com
DGPS Verification

 Purpose:

 - prove integrity of positioning system

 - offset check

 - prove correctness of geodetic datum

www.fugro.com
DGPS Verification Methods

 Several methods of performing DGPS Verification

 Alongside reference stations

 Platform transit

 Primary Positioning System versus Secondary System

www.fugro.com
Alongside Verification

 Same principle as gyrocompass calibration using two known points onshore


measuring range and bearing to a point on the vessel, preferably CRP or
the GPS antenna

 Alternatively, put the vessel’s GPS antenna on top of the control point

 If CRP is used gyro calibration and offset measurements must have been
performed beforehand

 Log positioning data using COP and process in form F- Positioning


Verification

 Agreement must be within 2 or 3 metres for standard DGPS, better than


0.5m for Starfix.HP or SkyFix XP

www.fugro.com
Alongside Verification

www.fugro.com
Platform Transit Method
Fix 4 Fix 3

Fix 5 Fix 2

Structure

Fix 6 Fix 1

Fix 7 Fix 8

www.fugro.com
Offshore - Platform Transit

 Sail around platform clockwise and anti-clockwise

 Centre coordinate of platform must be known

 Take fixes from an offset location every time two legs are in
line

 F - Transit Check Platform 4 Legs.xls

www.fugro.com
Positioning System Comparison Method

 Preferably alongside

 Compare primary and secondary position

 Integrity of positioning systems and offsets checks

 Logging every three minutes for one hour using COP-file

 F - Positioning System Comparison.xls

www.fugro.com
Motion Reference Unit Calibrations

www.fugro.com
Calibrations - Motion Reference Unit

 Vessel must be stable for proper calibration

 Measure by Total Station or Spirit Level


– along centre line (pitch)
– across centre line (roll)

 Alternatively: average measurements over 1 hour

 Important: MRU must be aligned with centreline within 0.5 degree !!

www.fugro.com
Calibrations - Motion Reference Unit

www.fugro.com
Calibrations - Motion Reference Unit

 Compare MRU units if possible

 Set C-O values in:


– Software
or in
– Motion sensor

www.fugro.com
Calibrations - Motion Reference Unit

www.fugro.com
Offset Measurements

 Offset Measurements presentation

www.fugro.com
End of Module

www.fugro.com
www.fugro.com
www.fugro.com