COATING
AG Min, Pressure at nozzle required for Abrasive blast cleaning.
a) 90 PSI b) 40 PSI c) 120PS!
2. For cone shaped tanks coating, Coating shall be done.
a) Shell side, b) Roof to bottom. c) Bottom
¥ PH value shows
Ans: Acid / alkaline nature /agvase
4. FBE coating powder in liquid form stage is mentioned as
Ans: Gel stage
5. Dew point (definition)
The amount of water vapors in the air expressed in percentage
6. Induction time (definition)
The length of time a paint has to remain after mixing and before application to
allow air bubbles to escape and chemical reaction to take place (The induction
time of a paint will be varied depends upon the ambient temperature).
The length of time a paint can remain applicable condition after mixing
following the induction time. (The Induction time of a paint will be varied
depends upon the ambient temperature).
; Min moisture content required for new concrete structure prior to coating.
a) 0.14 b) 0.1 c)0.04
8.1.4 The coating shall be applied after the full curing time of concrete in
accordance to SAES-Q-001. New concrete must have a moisture content of 4%
or less before the coating applications commence.
Max allowed speed of probe in Holiday test.
a) 30mm/s b)3mm/s_ c)300mm/s
9. Type of field adhesion test used for FBE coating.
Ans: Cross cut
10.Solvents and paints shall not be applied over substrate if temp. Greater than
Ans: 80°C ¢O”COATING
11.SSPC-SP7
a) Commercial blast cleaning b) Brush off blast cleaning c) White metal
cleaning
12.Surface profile measurement instrument.
Ans: Dial micrometer
13.Part of blasting equipment helped when a worker fainted down during
abrasive blasting.
Ans: Dead man’s Handle
14.Holiday test shall not be done if temperature of substrate is more than...
a) 78°C b) 68°C cyaerc. (Ko )
15.Potassium Ferro cyanide test is used for detecting.
Ans: Soluble Iron salts Ceresn) (s we )
ax allowed chloride content for abrasives.
a) 100 ppm b) 50 ppm c) 40pm
17.Stripe coating for Inorganic zinc coating shall be done at.
a) Before first coat application b) After first coat application
18.Attachment form submitted for coating inspector to review daily activities
according to SAES-H-100-01
a) Attachment Aand Bb) Attachment Cc) Attachment D
-SSPC SP1
Ans: Solvent cleaning
20.PE coating on piping can be done by Cross extrusion / sideways extrusion.
True /False
21.Profile measurement range for X-Coarse testex tape.
Ans: 35-115 Microns
22.Gauge used for dry film thickness on thin film coating.
a) Digital gauge b)Banana gauge c) Pocket spot Instrument gauge d)Alll of the
above
23.MSDS shall be used by.
a) Coating b) Solvent c) Cleaners d) AllCOATING
20Weld cap / internal protrusion shall not be more than
1.5mm
Requirement of Light used for confined space
a) 24 V explosion proof b) 12V explosion proof c)110V explosion proof d)12V
normal
26Sigma paint can be over coated with Jotun
False
Milica gel is nota good desiccant.
True /False
28.Silica sand can use for abrasive blasting
True /False
Coating shall be done within ----hrs of blasting completion.
a)2 b)3 4
30.Lining is not suitable for
a) Corrosion b) UV protection ¢) Abrasion
31.Who will recommend the solvent type for coating
a) Coating Inspector b) Manufacturer datasheet c) Contractor
32.VS% of Paint system is available in
a) SAES-H-001 b) SAES-H-002 c) SAES-H-101V
33.Hand tool cleaning will make the surface
a) Rough b) Smooth and shiny c) Very good Profile
34.Surface cleaning requirement for Road crossing area pipeline coating except
APCS-113C
a) Sal b) Sa2 c) Sa3 d) Sa2.5
listers formed on coating by
Water/solvent entrapment underneath the coating film.
36.Coating on sharp edges /corners will be
Removed / peeled offCOATING
37.Method of coating application used for immersed service
a) Air spray coating b) Airless spray coating c) Thermal spray d) Electrostatic
coating
38.Sealer coat application is possible immediately following thermal spray
coating.
True/falseQUESTIONS — 29.12.2019
1) Which standard to be follow for surface cleanliness of pictorial chart?
2) What is the moisture content allow before coating on concrete surfaces?
ose oy
3) What is standard for safety requirement of painting?
(hat is the maximum size of brush for paint application?
5) In what sequence the internal blasting will be done for the tank?
6) In inorganic zinc silicate what is zinc known as?
7) What is the speed for high voltage holiday detector?
[30cm
-} What is the maximum relative humidity for coating application?
Lok
(hich standard to be follow for surface cleanliness for commercial blast cleaning?
What is the percent of clean blast for commercial blast cleaning?
‘A-33 PERCENT ( C5 —
11) Which standard to be follow for surface cleanliness for near metal white blast cleaning?
12) What does the discontinuity mean?
13) In what sequence the internal blasting will be done for the tank? or:
8
Q
3
2
:
14) Holiday testing for the external FBE coating?
Ys
o
0
°
15) Blisters?
16) Where the dead men handle (shut off ) to be attached?
|
17) X coarse replica tape range?
18) What is dial micrometer?
gel is a good desiccant?
x
10) Define dew point?
21) Which adhesion test shall be done for FBE coating ?
N
2) Can new galvanized will be coated with APCS for more protection?
23) Corrosion?
Saudi Aramco: Company General Use24) Preparation of the damage areas known as?
hat is the 45:1 ratio for the airless spray pump?
26) How to store 12-meter length pipe FBE coated pipes? (2-4 )
jow to store 12-meter length pipe FBE coated pipes Cece
27) What is the maximum height of weld cap or internal root protrusion?
28) Sulfate and chloride content for abrasive?
29) Solvent shall not be applied to surface warmer then?
30) Thinner can be added to paint?
“1) Coating pull back in after paint cure happen on the sharp edges?
33 during internal blasting of a crude oil tank what surface preparation is required prior to start blasting?
fet sponge holiday volts for the internal tank
35) Before filling the water inside the tank what test has to be done?
36) Paint over buried ss pipe?
7) Profile range given in MSDS, PDS, and APCS specification?
ring water jetting blasting which device will protect from slippery of nozzle
‘WHIP LOCK
i
here the trigger safety catch shall be engaged in airless or conventional?
40) Relative humidity can be obtained by
41) What is pot life?
42) What is induction time?
‘Saudi Aramco: Company General Use1. blasting and coating shall not be performed if:
a) The substrate contains oil, grease, dirt, loose coating, loose rust, or other surface contaminants.
b) The substrate temperature is less than 3°c (5°f) above the dew point.
¢) Wind is strong enough to blow sand, salt spray, or other foreign matter onto the surface being
coated.
2. the following coating defect may be seen immediately after a thick film of epoxy coating sprayed
a) checking and cracking
c)_ mud cracking and chalking
d) blistering
3. anode, cathode, metallic pathway and electrolyte are elements of corrosion cells
b) false
4. Relative humidity can be obtained by using?
a) surface profile gauge
b) electronic dft gauge
d) surface thermometer
5. After applying paint on the surface, paint got wetted by raining, as a painting inspector what will you do?
a) recoat painting without removing existing coating
b) wait for water dry
¢) re-blast and re application
6. Single pack epoxy paint drying by?
a) oxidation
b) chemical curing
c) coalescence
7. the Swedish standard designation for commercial blast cleaning is.
a) sa
c) sa2s
sa3.
owe white metal blast for steel surface is defined as,
a) 100% of the blasted surface grains are in white metal conditions
£) 65% of the blasted surface grains are in white metal conditions
d) 35% of the blasted surface grains are in white metal conditions
9. an “induction” time for a paint is the
a) time between the manufacture date and application date
b) time between the application and fully drying of coating
d) time the coating and applied by spray after mixing
Saudi Aramco: Company General Use10. Saudi Aramco engineering standard which describe safety rules of abrasive blasting and coating
a) SAES-H-002
b)_SAES-H-002v
©) SAES-H-102
d) SAES-H-001
11. an abrasive blaster shall keep dead man control switch by
a) ATHIS HAND HOLDING ALONG WITH BLASTING NOZZLE
b) connected with blasting pot
©) control by crew supervisor
4) control by blasting helper
12, when an abrasive blaster is working in an offshore area, he must wear
a) safety shoe, leather gloves and coverall
b) blasting hood with fresh air line
)_ safety belt & life jacket
13, the tip size of an airless spray gun is define as 319
a) the fan width is 3° and the nozzle size is 019”
¢)_ THE FAN WIDTH IS 3002 AND THE NOZZLE SIZE IS .019”
d) the fan width is 302 and the nozzle size is .319”
14, the coating system that is applied on a splash zone area is
a) APCS-20
©) APCS-22
d) APCS-113
15. the recoating interval is the time between
b) the minimum time between the application top coat and color coding
©) the minimum time between the application stripe coat and spray application
4d) the minimum time between the application touch-up and full coat system
16. grounding shall be carried out for the following equipment
a) airless spray machine
b) air compressor
c) air receiver tank
17. corrosion can be control by
a) design and material selection
coatings and catholic protection
itors and alteration of the environment
18. what is anchor pattern
b) surface pitting
¢) milscale
d) all of above
‘Saudi Arameo: Company General Use19. what is rust grade Con steel surface
a) steel surface covered with both mill scale and rust - GRB
b) steel surface completely covered with rust pitting visible — GRD
©) steel surface completely covered with adherent mill scale litle or no rust visible —
20. galvanic corrosion occurs on which of the following substrate
a) concrete
b) wood
d) fiberglass reinforced plastic
21. relative humidity is
a) The amount of water vapour present in air expressed as a percentage of the amount needed for
saturation at the same temperature.
b) the lowest temperature at which moisture forms on a steel surface
c)_ the temperature at which moisture forms on a steel surface
22. dew point is the temperature at which
a) water freezes
b) humidity decreases
c)_ the air is saturated
d) CONDENSATION OccURS
23. the distance from nozzle to blotter paper when performed the compressed air quality test shall be
a) 30-40 cm
<) 60-70 em
4d) 55-65 cm
24. high thickness of zinc silicate cause
a) sagging
b) MUD CRACKING
©) curtai
4) cohesive failure
25. Ral number represents
a) thinner code
b) coLouR CODE
©) batch number
d) solvent code
26. if an airless spray pump ratio 35:1 fluid pressure 2800 required for inlet pressure
a) 100 psi
b) 90 psi
d) 60 psi
27. Which of the following is not information of daily report sheet?
a) dew point
b) relative humidity
¢)_air temperature
‘Saudi Aramco: Company General Use28, what profile range can be measured using x-coarse testex
a) 20-50p
©) 38-50 yn
d) 40-65 4
29, How many microns are in 4 mils?
a) 1154
b) 904
d) 1500
30, What are the characteristics of an abrasive?
a) density
b) hardness
©) shape
31. name the gauge used for measuring pressure at the blast nozzle
b) relief pressure gauge
©) air pressure gauge
) all of above
32, the air receivers that are used as a surge tank between compressor and blasting pot shall be hydro
tested at a pressure of at least
a) 150 psi
b) 125 psi
©) 175 psi
33. coating materials used for construction site must be cover and the temporary storage period shall not
exceed
d) 07 days
34, the use of recycled abrasives is permitted only in shops provided that the recycling system is
a) inspected and approved by coating inspector
b) approved by project manager
d) approved by project inspection department
35. after blasting the external coating surface chloride content shall not exceed
‘Saudi Aramco: Company General Use37. in case of brush application, the maximum brush size shall be used
a) 75mm
b) 100mm
4) 150mm.
38, what defect could occur if the profile is higher than specified
a) blister
b) mill scale
d) cause paint adhesion
39, SSPC SP 3 is a standard for
a) white metal blast cleaning
b) pickling
d) hand tool cleaning
40. the temperature of which moisture begins to condensate on a steel surface is called
a) relative humidity
©) maximum surface temperature
d) minimum surface temperature
41, What standard explains how to measure dry film thickness with magnetic gages?
a) sspc-pal
©) sspe-pa3
d) sspe-pa4
42. What documents will describe the health and safety of hazard of a coating material?
a) the job specification
c) SPC safety specification
d) OSHA standard
43, What is the correct storage temperature range for coating?
a) 30to90f
b) 40 to 120f
c) 45to 100f
44. Standard test method for measuring adhesion by the tape test.
b) ASTM D 3363
c) ASTM D 3350
d) ASTM D 3747
45. wet sponge holiday detector is checked with-----de volts for DFT not exceedin,
a) 90v/ 600microns
b) 69.5v/ 500microns
d) 67.5v/1000microns
Saudi Aramco: Company General Use46. What DFT will get, when applied 150, WFT with 50% of volume solid?
a) 85micron
b) 90micron
©) 100micron
d) 75MICRON
47. What is the field adhesion test on FBE?
a) cross cut adhesion test
b) dolly test
d) allofthe above
48. What is the minimum nozzle air pressure required for abrasive blasting?
b) 75 psi
©) 100 psi
4) 80 psi
49. What would you do if you receive coatings that have exceeded their shelf life?
a) use the coating if it’s the appearance is normal
b) use the material if there is no hard setting of pigment
Q
d) Contact the coating manufacturer for information about the usability of the coatings.
50. What is the correct formula for computing the wet film thickness (WFT), needed to achieve the specified
dry film thickness (DFT) of a coating?
b) wit = dftx 0.50
)_ wft = dft x percent of solids by wt.
d) dftxvs
51. which of the following characteristics of paint is easily tested in the field?
b) dry opacity
¢) identification of the solvent in the paint
4d) identification of the paint resin
52. Windy condition can cause which of the following paint defects?
a) wrinkling
b) sagging
©) fish eyes
53. if the given DFT is 400 microns and volume of solids is 100% what is the WFT
a) 450micron
b) 500micron
d) 350micron
54. Grounding wire for blasting and coating equipment shall be awg?
a) 6 or larger
b) 8 or larger
d) Sorlarger
Saudi Aramco: Company General Use55. What profile range can be measured using coarse testex?
* a) 40-65microns
¢) 30-70microns
d) 15-SOmicrons
56. What profile range can be measured using x coarse testex?
a) 20-SOmicrons
b) 42-70microns
d) 30-70microns
57. The maximum length of field girth weld coating on pipeline shallbe? Fg (6 256
a) 12inch or 300mm 4
b) 10inch or 250mm Lig uwo — bl 20
cc) 1Sinch or 200mm
58. for internal FBE coating, the weld cap or internal root protrusion shall not be more than
gon
338
2
HH
59. Which APCS is followed for external FBE coating of pipe?
a) apes-117
b) apcs-102 a,b,c
d) apcs-113 a
60. Which apcs is followed for internal FBE coating of pipe?
a) APCS-117
cc) APCS-104 A,B,C
d) APCS-113
61. Whatis the de volt range for holiday testing of FBE coating?
a) 1000-1500 de aa2ky
b) 2000-5000 de area L co TWTEROBLK
©) 1500-2000 de Qlooy SP +
EXTER NAL LSS
62. What is SAMSS for internal FBE coating?
a) 09-samss-067 [Qual Reqs for Internal Coating Systems Used in Immersion Services-APCS-
2A,8,C E[SFEL FIGFPE],GIGFVE]
bb) 09-samss-087 [Qual Requ for Epoxy Coatings for Application on Damp Steel Surfaces]
)_09-samss-107 [Qual Req and Application of Composite Fluropolymer/Ceramic Coatings to Fasteners}
[Qualification Requirements for Shop-Applied Internal FBE Coatings}
63. What is SAMSS for external FBE coating?
a) 09-samss-067[Qual Regs for Internal Coati
2A,B,C EISFE],FIGFPE],G[GFVE]
b) 09-SAMSS-089 [Qual Reqs for Shop-Applied External Fusion Bonded Epoxy Coating for Steel Line]
)_09-samss-107 [Qual Req and Application of Composite Fluropolymer/Ceramic Coatings to Fasteners]
4) (09-samss-091 [Qualification Requirements for Shop-Applied Internal FBE Coatings]
Systems Used in Immersion Services-APCS-
‘Saudi Aramco: Company General Use64. In which form FBE coating material is prior to use?
a) liquid containers
b) solid
d) gas
65, SSPC stands for?
a) steel structure painting council
b) steel structure painting code
d) steel structure painting committee
66. What is the speed of high voltage holiday detector while performed testing?
a) 90cm/sec
b) 80cm/sec
d) 75cm/sec
67. while repair on touch up of galvanized steel surface, what generic paint used as primer?
a) zinc phosphate epoxy
b) zincsilicate
d) mastic epoxy
68. Which information is not available in TDS?
a) volume solids
b) flash point
d) thinning ratio
69. For blasting nozzle size of 1/2”, what shall be the minimum CFM of compressor?
a
gees
Bake
au
70. Aramco standard safety for blasting and painting
lok
71. VIL TEAST for?
72. brush off blast
73. Which is not surface preparation method?
74, Blasting on concrete surface is slowly, oe horoughly?
Gort
75. Buried stainless steel lines shall be externally coated with FBE, halide free liquid coating, APCS-113A, or
viscoelastic coating APCS-113C depending on operating temperature
76. Abrasive blasting shall be carried out only when the steel surface is at least 3°c above the dew point
77. Coupling used in blasting?
‘Saudi Aramco: Company General Use78. Unit for adhesion pull off test as per ASTM 4541 result
79, Flash rusting will start if the humidity level is?
80. The high-pressure hose is fitted with a safety device known as?
81. One advantage of centrifugal blast machine is low cost, easy to clean, complex structures, less moving
parts and contaminants?
82. What is the coating interval?
83. ASTM D 4128 stands for?
84. Hand applied splash zone compound is ?,
85. Brush off blasting standard?
86. Where do you find the surface profile range?
87. When the blaster is about to faint which device helps him from stopping the blasting?
88. The minimum temp difference between metal temp and the dew point?
89. ioz is
90. In which instrument surface profile measurement can be done
91. Maximum length required for FBE field girth weld is
‘92when steel surface is contaminated by water of salts, the failure the coating occurs in the form of bubbles
shape is called?
‘Saudi Aramco: Company General UseCoating Questions
Blotter paper used to check
a
b.
d
Quality of airy
Pressure of air
Quantity of air contamination
None of the above
Airles spray pressure 421 denotes what?
a
b.
4
Fan width 4 degrees and tip size 0.021inch
Fan width 400 degrees and tip size 21mm.
Fan width 40 degrees and tip size 0.021inchy
Fan width 40 degrees and tip size 2.1 micron xg
Thermometer shows
a
b
©
d
Thinner level
Surface cleaning
Humidity
Air temperaturey-
In psycometer RH & TD can be measured by what two temperature?
b.
4.
Dry blub & wet bulb temperature
Dry bulb & air temperature
Substrate & air temperature y
Air & dry bulb temperature
Apes-4 is a/an:
b.
c
d
Epoxy coating in atmospheric services
Alkyd coating for atmosphere services
Heat resistant aluminum for atmospheric services
None of the above
‘APCS 113A can be applied as
b
«
4
Coal tar epoxy
Epoxy coating on buried pipeline y~
Viscoelastic coating system for buried pipeline rehal
Epoxy coating on weld joints
iltation
What should be the difference between substrate temperature and dew point
a
b.
c
d
3degreew
S degree
I degree
None of the above
MDS shall be available on site for
b.
4
Solvent
Coating
Surface cleanliness
Allof the above 710.
wy
12,
13,
14,
45.
16.
Lining shal not be used to protect the substrate from following sy,
a Corrosion
b. UV protection
©. Erosion
d. Abrasion
Epoxy immersion system consist of
a. Hardener & base 2can
b. Hardener, base & thinner
c. Primer, base & hardener
d. Single component
SSPC-SP-5
a. Solvent cleaning
b. Seay
©. Brush of blast cleaning
4d. None of the above
Brush of blast cleaning
a SSPC-SP7
b. SA25
cc. SSPC-SP1
d. SSPC-SP6
Blasting on concrete surface will be
a. Use large abrasive
b. Move the nozzle slowly
© Move the nozzle quickly
d. Keep the nozzle close to substrate
Blasting and painting shall be carried only if the substrate temperature
a. 3degree less than dew point
b. 3 degree above the dew point w
Not required
dd. None of the above
In Galvanic term, ‘metal contact each other which results in electrolyte reaction
a. Similar
b. Dissimilac”
©. Allof the above
d. None of the above
Amine isa
a. Solvent
b. Curing agentyy
. Thinner
d. None of the above1.
18,
19.
20.
21.
22,
23.
24,
Induction time
Time paint is kept after mixing, before application.
b. Time taken to mix the paint
Time with in the paint shall be used
4. Time taken for curing of paint
Pot life
a. Life time of blasting pot
b. Usable time of the mixed paint —
. Total time of application with the mixed paint
d. None of the above
Which of the following shall not be done for glass line coating
High voltage AC current
b. Low voltage sponge holiday
©. Visual inspection
d._ Blasting inspection
Air receiver Vessel/tank should be tested
a. Annually
b. Every 2 months
Every 6 month
d. Noneed if the vessel is new
‘What is maximum length of FBE coating on field girth weld
a. 110mm
b. 280mmy
400mm
d. 450mm
FBE coating shall be
‘a. Thermos set
b. Thermoplastic
Liquid coating ~
d. Electromagnetic fused
Grounding shall be done for
a. Air compressor
b. Air receiver tank
©. Blasting nozzle
d. Allofthe above y
Immersion coating system (hot evaporator) can be applied by
a. Hot spray machine
Brush
k
: Airless spray machine 7 er ane
None of the above25.
26.
27.
28,
29.
30.
31.
32,
33,
34,
35.
Rust bloom / rust back happened on freshly blasted surface because of
h humidity
b. Moisture
Salt in air
d. Ally
‘Comb gauge is used for
a. Checking blasting nozzle size
b. Pressure of air in the blasting hose
WET on horizontal metal surface y
d. WET on circular metal surface
In immersion services, after complete coating system is done before operating the tank which of the following
point is to be done.
a. Holiday & repair »
b. Left for curing
Check DFT
d. Check damages
Silica gel is not very good desiccant.
TRUE OR FALSE
DFT formula is WET x 96VS
TRUE OR FALSE
v
If the blaster fell down during the bla:
injuries.
ig, what is the safety precaution should be taken to save him from
What isthe Unit of ASTM 04541 adhesion test?
Coarse and X-coarse range?
What attachment should be filed for critical coatings for Saudi Aramco inspector review?
What i the standard for safety?
What is Saudi Aramco standards for plant & equipment facilities?1. Bar to Psi
a)60 b)45 c) 14.5
2. Thermal Spray Coating can be sealed immediately after application
True / False
3). Sealer coat applic
True / False
4). Power tool cleaning of steel surface will
A) Make the surface smooth and polishing
b) Make the surface rough and etched
) Make the surface high anchor pattern
d) Be easy to and less time consuming
5). Commercial blasting of steel surface is defined as.
a). 100% of the blasted surface grains are in white metal conditions
b). 95% of the blasted surface grains are in white metal conditions
). 65% of the blasted surface grains are in white metal conditions
4d). 35% of the blasted surface grains are in white metal conditions
6). Potassium ferricyanide paper turn color in presence of ferrous salt
a) Black 8) Blue ) White D) Green
7). ASTM D 4541 Pull off Adhesion test Values are reported
A).0B—-5B —B).OA--SA —_C) Barcol unit _D) kg/m2.Mpa.psi
8). PH value Shows
a). Acid Alkaline Aquase
9). An Epoxy Immersion coating system consists of
a). A Base, A Hardener and powder- Total of 3 Cans,
b) A Base, A Hardener and Thinner- Total of 3 Cans
). A Premixed base and hardener ~ One and Only
d). A Base, A Hardener ~ Total of 2 Cans
10). If a coating operation requires only 5 liter of epoxy coating and the painter has only 20 liters of
consists of a base can and a hardener can. Then he should mix
a). By taking % can of base and % can of hardener
b) By taking % can of base and % can of hardener
‘Saudi Aramco: Company General Use
coating which©) Full can of base with full can of hardener
4d) He should not mix at all but wait for arrival of new 5 liter cans
11). What is the formula finding DFT = WET X % OF VS
True / False
112). what is the formula finding WFT = DFT/ % OF VS
True / False
13). Swedish Standard designation for Near White metal blast cleaning is
a). SA2
b). SA2-1/2
0). SA3
d) SAL
14). In a Confined Space, the lighting system to be used shall be of
a). 110 Volts of Ordinary lamp
b). 24 Volts explosion proof type
€).12 volts of Ordinary lamp
d). 12 Volts, of Explosion proof Type
15). The Pressure ratio of an airless spray machine is the ratio of
a). Compressor outlet pressure and airless spray machine inlet pressure
b). Airless spray machine in let pressure and the outlet pressure
©). Airless spray machine outlet pressure and the spray tip outlet pressure
4d). Air receiver out let pressure and spray machine inlet pressure
16). The travel rate of detector electrode shall not exceed nor shall it be allowed to remain stationary while the power
ison
a). 15 inches /S
b). 300 mm/s
©).500 mm/s
4d), there is no limit
17). The holiday test of tank bottom internal coating shall be carried out using
a). 3000 volts high voltage comb type holiday tester
»). 2000 volts high voltage comb type holiday tester
¢). 100 volts low voltage wet sponge type holiday tester
Saudi Aramco: Company General Used}. 67.5 volts low voltage wet sponge type holiday tester
18). To aid in avoiding pinholes and bubbles occurring in the intermediate coat of epoxy be applied to the inorganic
zine primer
a). A Mist-Coat thinned 30 to 50%
b). A Mist-Coat thinned 10 to 20%
). A Mist-Coat thinned 20 to 40%
4d). None of the above
19). what will you do if blasting profile will come more from the specification.
Ans: 45°
20). could you apply to the chlorinated rubber paint on Phenolic
Ans: False
22). during abrasive blasting not included for the PPE from below
A) Safety Shoe 8) Coverall C) Hard Rubber gloves D) Water Jet nozzle / Gun
23). Epoxy immersion service coating application overspray coated surface root cause..
a), Wastage
b). Improper Spray technique on the surface
0.A&B
D). None of the above
24) Storage Tank Inspection survey
A) 1 year one time Inspection
8) Tow year one time inspection
¢) One month Inspection
4) No inspection
25) Define SSPC
‘Ans: Procedure for Determining Conformance to Dry Coating Thickness Requirements
Saudi Aramco: Company General Use