You are on page 1of 1

MOTOR GENERATOR SYSTEM MODEL MG-1

The Motor and Generator / Alternator system consists of a control panel and
various machines. The machines are mounted on a special frame to accommodate
coupling and electrical connections. All wiring connections from machine windings
are brought out to 4mm terminals. Connection leads with banana plugs facilitate
quick and easy connections between the Motor-Generator System and other
controls. A fault insertion module for machine winding is available as an optional
item for student troubleshooting exercises. An operation Manual with student
experiment activities is provided.

Educational Objectives:
• Induction motor as prime mover principles • Saturation Curve of Generator/Alternator • Balance Load Effect of
Generator/Alternator • Unbalance Load Effect of Generator/Alternator • Open circuit, Short Circuit characteristics •
Voltage regulation in Generator/Alternator • Losses and Efficiency in Generator/Alternator • Troubleshooting Generator/
Alternator system

Specifications:

Control Panel :
• Power supply : 220/380 VAC, 3A
• Power Indicator : Indicate the incoming power at L1/R, L2/Y, L3/B
• Power Control : Start Button, Stop Button, Emergency Button
• Lamp Indicator : Indicate run, overload and emergency condition on Instrument panel
• Circuit Breaker : ELCB (Earth Leakage Circuit Breaker), MCB (Miniature Circuit Breaker)
• AC Voltmeter : Used to measure AC voltage
• AC Ammeter : Used to measure AC Current
• Motor Switch : Used to connect-disconnect the motor with the power supply
• Generator Switch : Used to connect-disconnect the generator output to load.
• Generator Excitation : To control the generator output
• DC Voltmeter : To measure the DC Voltage
• DC Ammeter : To measure the DC Current
• DC MCB : for short circuit protection
• Excitation Switch : To connect the Excitation voltage to the Excitation winding
• Excitation Control : To control the Excitation voltage
• Variable DC supply : 0 to 180VDC
• Generator : DC Shunt Wound Generator
• Alternators : 1 Ph. Alternator 300VA
• Motors : 1. DC Shunt Motor 1 HP
2. AC Three Phase Induction Motor, 1 HP
• Accessories : (i) 1 Set of test leads.
(ii) Base plate machine bed with anti vibration rubber feet and protective cover.
(iii) Student experiment manual.
• Extras : (i) 1-phase resistive load
(ii) Faults Insertion System for Motor/Generator winding
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT ANY PRIOR NOTICE
DUE TO CONSTANT DEVELOPMENTS

Advance Electronic Industries


1/135, Nahar & Seth Indl Estate, Pannalal Compd., L.B.S.Marg, Bhandup (W), Mumbai 400078.
Phone: 2596 9769, 9770, 2147, Fax: 2596 2147
E-mail: info@adtrontechnologies.com, sales@adtrontechnologies.com