Carrier Current Systems

Power Line Carrier


UL Listed Signal Generator
6850 Series
FEATURES:
Solid-State Design
Compatible with Simplex Time Control
Centers
4 Frequencies - Individually Tuned
Individual Frequency Amplitude Control
For Single-Phase or Three-Phase Power
Distribution Systems
Complies with UL Standard 863

DESCRIPTION:

The 6850 solid-state signal generator provides power


line carrier current capabilities for electronic clock 6850-9003/2850-9004
systems and control applications. When the signal SIGNAL GENERATOR
generators are combined with Simplex Time Control
Centers, existing AC power distribution systems can be
utilized to transmit control and synchronization
information to clock, signalling and relay control SPECIFICATIONS:
modules. 6850-9003/2850-9004
6850-9003 Master Signal Generator, Single-Phase or Input: . . .. . . .. .. . . .. . .. . . .. . .. . .. . .. . . .. . .. . .. . . 120/240 VAC 50/60Hz
Three-Phase Signal with Oscillators, *3510, l 4200, 3A @ 12OVAC
*5010 and *8000 Hz Output*. 600V Maximum 1.5A @ 240VAC
Distribution Capability. Finish: .. . . .. .. . . .. . . .. . .. . .. . .. . . .. . .. . . .. .. . . . .. .. . . .. . .. Textured Black
2850-9003 Slave Signal Generator for 6850, without Size: . . . .. . .. . .. . . .. . .. . . .. .. . . .. . .. . . .. . .. . .. . . 12”W x 18”H x 8 1/8”D
Oscillators, 600V Maximum Distribution Capability. Approx. weight: . . .. . .. . . .. . .. . . .. .. . . .. . .. . . .. . .. . .. . .. . . .. 55 Pounds
Environmental Limitation: . . . .. .. . . . .. .. . . .. .. . . 32°F to 122°F
(0°C to 50°C)
* The 6850-9003 Signal Generator is supplied with 95% Relative Humidity
four standard output frequencies. Each of the four (Non-Condensing)
frequencies is individually field adjustable. Not intended for outdoor use.

Note: Consult Local Simplex office regarding proper


application and determination of required signal
generator quantity.

Q 1994 Simplex Time Recorder Co. Publication S6850-0001 1-94


firealarmresources.com
6850 SINGLE-PHASE SIGNAL APPLICATIONS

(Phase to Ground)

TYPICAL BLOCK DIAGRAM

BUILDING POWER DISTRIBUTION SYSTEM


120/208VAC OR 120/24OVAC

PRIMARY
VOLTAGE

120
VAC

NOTE: KVA rating of main transformer will determine the number of 2850s required to feed adequate signal within
the facility.

01 FUSED DISCONNECT, 30 AMP, BY OTHERS

2
firealarmresources.com
6850 THREE-PHASE SIGNAL APPLICATIONS

(Across Phase)

TYPICAL BLOCK DISTRIBUTION SYSTEM


277148OVAC OR 346/6OOVAC

;X&DING’S

TRANSFORMER

I
L----e-- __----- ----a---

6850 2850
9003 9004

6351 OR
6400 MTG LV
120 120 \ 1
VAC VAC

NOTE: Additional 2850s may be required depending on KVA rating of main transformer.

01 FUSED DISCONNECT, 30 AMP, BY OTHERS

3
firealarmresources.com
STANDARD PRODUCT DESCRIPTION

,,
DIMENSIONS 6850/2850

a l/8” (3OEnm)
(206mm)
(270mm)

[
I”
nr n:‘I
16 13132”
(417mm)

I
L A-

1 I,
(25.4mm)

sBSimplex Offices
Gardner, Massachusetts
and Representatives
01441-0001
Throughout
U.S.A.
the World

All specifications and other mformation shown were current as of publication, and are subject to change without notice. Printed I” U.S.A.

firealarmresources.com