Loss-in-Weight Feeder
Instructions Manual
BV-H2064GB'
PASS - Service you can rely on
Fast, comprehensive, anywhere in the world
Quality and reliability are the cornerstones of our company’s philosophy. That is why we consider a
comprehensive service concept simply par for the course, from strict quality control, installation and
commissioning through to seamless support across the entire product life cycle.
With over 30 service stations and over 180 service specialists, you can count on us to be there whenever –
and wherever – you need us. It doesn’t matter where you are, our specialists are there to advise and assist
with the best in worldwide, personal, comprehensive service.
During office hours, service specialists from all divisions are on hand to analyse problems and failures.
Look at w w w .s c h e n c k p r o c e s s . c o m for your nearest Schenck Process Location.
Customised to meet your requirements, our comprehensive Process Advanced Service System provides
you with the best service. Are you looking for individual, perfect-fit service solutions?
Then our, the modular service system PASS, is the ticket. It covers the entire service spectrum, from simple
inspections through to full service. Interested?
Then find out more about the individual components at w w w . s c h e n c k p r o c e s s . c o m / e n / s e r vi c e .
All information is given without obligation. All specifications are subject to change.
1 ON MANUAL...................................................................................... 1
3 OVERVIEW ........................................................................................ 4
3.1 What is DISOCONT? .............................................................................................. 4
3.10 Batching.............................................................................................................. 11
3.11 Linearization....................................................................................................... 12
4 CONTROL........................................................................................ 13
4.1 Start DISOCONT................................................................................................... 13
5 COMMISSIONING............................................................................ 50
5.1 Installation.............................................................................................................50
6 CHECK............................................................................................. 59
6.1 Starting Check...................................................................................................... 59
7 PARAMETERS ................................................................................ 62
7.1 General Information............................................................................................. 62
1 On Manual
The Operating and Service Manual is designed for use by the operator and the service
engineer.
This manual is available both in printed and Windows-Help (Winhlp) formats.
You may also access the printed version electronically in the Adobe PDF format.
The daily user will find the information he needs in the Operating Manual.
Information on the DISOCONT electronic design is included in the System Manual
(BV-H2085).
2 Safety Instructions
To avoid personal injury and equipment damage, follow the safety regulations stated
below.
Additionally, you should observe:
The presence of this symbol indicates that the machine or component used
has the potential to cause severe injury or death.
Personnel
Preparation, installation, commissioning, operation, maintenance, and servicing may
exclusively be performed by skilled persons only.
All persons working on the measuring system are required to observe the safety hints
and know the parts of the technical documentation relevant to their work.
The supervisor is responsible for instructing his operators to observe all regulations
and instructions given.
Parameter Changes
The measuring system's functionality is determined by parameters, which must
exclusively be changed by persons familiar with the measuring system operating
principles (e.g. after training by Schenck Process). Parameters incorrectly set may
cause injuries or damage to the machine whenever a user control system is
connected. They can also adversely affect weighing operation.
Password
Software parameters are protected from unintended change by password. The
measuring system user has to ensure safe password handling.
Error Message Acknowledgement
2 BV-H2064GB , 0915 DISOCONT Instructions Manual Loss-in-Weight Feeder
© Schenck Process
Safety Instructions
Error messages may be acknowledged only after cause of fault has been remedied.
Before you acknowledge an error message, check to see that connected peripherals
properly operate. Check to see that connected control systems, if any, are in fail-safe
state.
Maintenance and Repair
• During maintenance and repair, observe any warning symbols on the scale.
• The devices may be operated only in the provided housings. There is danger
of contacting live parts.
Moisture Protection
Protect all system parts, electrical items in particular, from moisture (e.g. during
maintenance and servicing) when housings are open. Observe housing protection
standards.
Modification & Replacement
Unauthorized modifications to the system and/or use of replacement parts not
supplied by Schenck Process voids Schenck Process's liability for any resulting
damages. This particularly applies to modifications, which have the potential to affect
the operating safety of the measuring system.
Replacement of Components
Spare parts must meet the technical specifications indicated by Schenck Process. To
ensure this requirement is met, only genuine Schenck Process spare parts should be
used. When using other spare parts, the warranty will be void.
3 Overview
The Overview chapter explains the principle functions of the DISOCONT system used
in conjunction with a feeder or meter.
The DISOCONT is designed for continuous measuring and control tasks as well as
discontinuous batching.
The system also performs all weighing and processing functions required for the
measuring and feeding of bulk solids.
• Steel
• Basic Materials
• Cement
• Food
• Chemical
In connection with the corresponding mechanical equipment, the following systems
are supported:
• Belt weighers
• Weighfeeders
• Filling systems
• Volumetric/Synchronous Mode
Designed as special feature of volumetric mode, this mode ensures smooth
change-over from gravimetric to volumetric mode.
MAX
FILL
LEVEL
MIN
FILL
ECHO
VOL GRAV VOL
TB fuellwaeg_gb.cdr
3.7 Control
The DISOCONT controls the material discharge from the loss-in-weight feeder in a
closed or open-loop. There are speed controlled feed units (e.g. feed screws and
spindles) and amplitude controlled feed units (e.g. vibro feeds). There are speed-
controlled feed units, e.g. feed screws and spindles, and amplitude-controlled feed
units, e.g. vibro feeders.
The "Control" figure shows the loss-in-weight feeder control principle. Set point is
compared to actual feed rate by the SET/ACT difference, routed to controller RP. The
controller varies feed unit (F) feed rate until actual value corresponds to setpoint. The
controller is equipped with additional pre-control, which enables set point variations to
be acquired faster.
Fig.: Control
• Disturbances resulting from the weighing process, such as, discharge errors
caused by inhomogeneous material, varying material properties, or feed unit
non-linearities.
The first type is available, both in measuring signal and material flow. The second type
exclusively affects the measuring signal and must not enter into measurement value
evaluation or control system. To prevent this from occurring, this kind of disturbance
has to be recognized and classified.
The figure below shows disturbance patterns of the second type:
• Filling without fill control: The (DAE)'s Disturbance Auto Eliminator permits
material to be refilled with no need to change operating mode ("basket filling").
With normal eliminator calibration, this has to take place smoothly without
delay. A special setting enables even more sophisticated filling processes to
be realized.
To simulate the conditions during filling, the fill unit control magnitude is adapted to fill
weight.
This helps to increase feeding accuracy during the filling phase and ensures smooth
change-over to gravimetric mode.
See parameter 10.11 "Material flow compensation"
3.10 Batching
In batch mode, a preselected amount of material is discharged. If batch setpoint is
reached, batching process is complete.
Batching can be performed in any mode and with any variant.
The figure below shows the batching sequence of a controlled system:
Fig.: Batching
The represented sections mean:
0 : Start batch
1 : Stop batch
2 : Continue stopped batch
3 : Continuously decrease set feed rate
4 : Stop batch automatically if preset amount has been batched.
3.11 Linearization
If a vibro feeder is used as feed unit, we have to consider that the feed rate of the
vibro feeder's feed rate range is non-linear. Feed rate behaves progressively as a
function of amplitude. The "Linearization" figure shows the correlation between feed
rate I and amplitude S.
Linearization ensures a higher control quality over the entire setting range.
Overshooting in the case of setpoint steps is avoided. In volumetric mode, setpoint
and feed rate actual value are fairly balanced.
100%
1,5
I~ a . S
50%
S
0 1 mm 2 mm
Vh206415.cdr
Fig.: Linearization
4 Control
This chapter describes the DISOCONT control in the case of controlled discharge
weighing. The DISOCONT and a connected loss-in-weight feeder can be controlled
either via a local control unit VLB, Easyserve software from a PC or a local controol
box VLG (emergency mode).
DISOCONT and connected loss-in-weight feeder can be controlled either via
• Parameter settings
• Setpoints
• Counter readings
• Feed index
This manual uses the abbreviations "<Key Name...> key", e.g. <Return> key. Cursor
keys are called "cursor <UP> or <DOWN>".
The DISOCONT is operated with the use of function keys (yellow), keypad (white) and
Return key (red).
Function keys are assigned in accordance with the specific control situation. The
particular function is displayed over or right next to the key.
You can increase display contrast by operating key <.> and single or repeated
operation of the <UP> cursor. Use <.> keys and <DOWN> cursor to decrease display
contrast.
On standard, the background lighting cuts off after 15 minutes and comes on again
after operation of any key. Use shortcut <.> and cursor key <Left> for steady light.
Shortcut <.> and cursor key <Right> lets you return to default state.
The state selected last is maintained also after power failure.
The elements shown in the figure have the following meanings:
4.2.1 LED
If the green LED lights, DISOCONT is ready to operate.
Function key F7 serves as hot-key designed to directly perform special functions. Key
is assigned using Parameter P 02.14 "Hot-Key F7".
• No alarm is available.
• External release signal has to be given. If this is not the case, event message
IL-01 "No Release" is output.
Starting scale:
1. Press <ON> key.
Feature
"ON" appears in first text line in double-size letters.
Stopping scale:
1. Press <OFF> key.
Scale cuts off. Measurement terminates if the time set in Parameter P 05.02
"Measuring Delay" has elapsed.
Feature
"OFF" appears in first text line in double-size letters.
NOTE: The use of the operating functions always starts from normal display.
Go to normal display by pressing the <ESC> key as many times as required.
NOTE: You can abort an automatically started filling process by using the "STOP
Filling" function.
Filling continues until
• the time set by Parameter P05.19 "Pulse Filling" has elapsed (P05.09 =
F_CONTROLmin)
Features
• Event message LO-08 "<LIFTmin Event": If fill level falls below the LIFTmin
limit value, no automatic filling takes place. Feeder can be filled only with the
aid of the filling function.
• Event message HI-01 "L/C Input > MAX": Filling aborts (full scale value).
NOTE: "START Emptying" function does not stop automatically. Abort discharge by
using the "STOP Emptying" function or the <OFF> key.
To empty hopper during discharge weighing:
1. Call up function distributor using <MENU> key.
2. Select function using cursor keys.
3. Activate function using <Return> key.
4. Start discharge process using <ON> key.
5. If need be: Stop discharge process using <OFF> key.
6. Complete discharge using "STOP Emptying" function.
Features
• Event message LO-08 "LIFTmin Event": Beyond the LIFTmin limit, filling is
automatic provided that discharge mode has been deselected. Below this limit
(event message LO-08), the filling function has to be used.
Differential of F 1000 kg/h Bin level differential filtered only with P 07.02
Bypass
1.007 Currently active correction value
adaptation
Data are also acquired in turned-off state of feeder.
NOTE: Value on display remains active until function is terminated by operating the
<ESC> key in normal display.
4.5.4 Trend
The trend refers to the graphical representation of results measured over the time on
control unit VLB. Resolution is 50 * 100 pixels (value, time).
Settings are made using Parameters P02.15-P02.18. The following measurement
values can be displayed:
Rel. bin level F
Current setpoint W
Bin weigher rel. fill
B
weight
Deviation Xd
Control magnitude Y
NOTE:
The trend values are continuously transferred to VLB and stored there. Only if time
axis of P02.17 or represented value P02.18 are changed, the values stored in VLB are
deleted. The Upper and Lower Limit parameters can be changed without loss of
values.
Selecting Mode
1. Call function distributor with <MENU> key.
NOTE: You can also print totalizing counter readings during batching.
Take these steps:
1. Call up function distributor using the <MENU> key.
3. If several events are available, these can be viewed by operating the <UP> or
<DOWN> cursor.
5. Enter password.
Prerequisites
4. Acquire measuring result with <Return> key or abort with <ESC> key.
The result of the taring program enters into P09.04 "Basic Tare", and Parameter
P09.05 "Tare Correction" is set to zero.
NOTE: Load cell loads below 3% are reported by event message.
Display
• After taring, deviation of new tare from previous tare is displayed in first
display field.
3. Start program.
4. Wait for "Apply Check Weight" prompt to appear in first text field.
• After weight check, weight value measured is displayed in first display field.
• Weighing systems directly supported on load cells: Error smaller than 0.5%
• After 5 seconds, maximum feed rate signal disturbance value "DAE: max =" is
displayed in the first display field and disturbance value standard deviation in
the second display field.
Special Messages
Message Cause
Aborted Result not acquired
Event message SC-07 "DAE Event" Disturbance Auto Eliminator responds
Event message SC-08 "DAE Fault Event" Strong disturbance signals
• Basic calibration is complete (i.e. external controller zero point and range
have been set).
After performing the steps below, you may start "Controller Optimization"
program.
• Perform linearization.
Prerequisites
None. You can call up program at any time.
• After 5 sec., "CG: P-Component KP" and "I-Component TN" values appear on
display.
• No simulation mode
• No batch mode
• Volumetric mode
• Feeder switched on
Procedure:
1. Select the calibration program „set nominal feed rate“
3. Before the actual start of program the current control magnitude is displayed
on the upper display and the control magnitude of the calibration program on
the lower display as a check. After a new start command the calibration
control magnitude is displayed on the upper display. The measured feed rate
can be observed on the lower display.
• at control unit VLB or via EasyServe by starting the calibration programs „set
feed rate“ or „feed rate + nominal lift“.
• via Softkey from control unit VLB. Here it is possible to choose between the
variants nominal feed rate or nominal feed rate + nominal lift by repeatedly
pressing the key during the measurement. (Parameter P02.14 = „Calibr. Feed
Rate“)
After starting the feeder is automatically switched to volumetric mode, the sum of the
parameters „bypass“ and „increase control magnitude“ being displayed as control
magnitude and the scale switched on. Current filling and the simulation mode are
interrupted. During the run time of the calibration program the monitoring of the limit
values I-Min and I-Max and automatic filling are not active.
The program starts only if the following starting conditions have been met:
• No batch mode
• No alarm
• the scale is switched off (also in the event of an ALARM or missing release) or
switched over to simulation mode
• 0,1 * LC nominal load/h < feed rate determined < 60 * LC nominal load/h
• Volumetric/gravimetric
To start/stop:
1. Select function in Calibrating Menu using cursor keys.
3. Enter password.
10. Acquire new value with <Return> key, or reject with <ESC>
key.
3. Enter password.
Sample Printout:
• Feeder disconnected
Take these steps:
1. Call function distributor using <MENU> key.
5. Acquire batch setpoint and return to normal display using <Return> key, or
• Batch setpoint
• Batching started
To deselect batch mode, take these steps:
1. Call up function distributor using <MENU> key.
Prerequisite
Prerequisites
• Feeder disconnected
To deselect batch mode, take these steps:
1. Call up function distributor using <MENU> key.
4. Acquire measuring result with <Return> key or abort with <ESC> key.
Display:
• While function is active, first text field reads "TB: Measurement running", and
first display field shows the residual run time in %.
• If function is complete, first text field displays "Deviation", and first display field
shows the deviation value related to previous tare value.
• Second text field changes to "Tare", and second display field shows the tare
value related to load cell rated capacity in % (P26.04 "L/C Rated Cap.").
Special Messages
Message Cause
Aborted! Process aborted; no change.
7. Acquire measuring result with <Return> key or abort with <ESC> key.
New value for Parameter P24.24 "Range Correction" is computed using the following
formula:
Abbreviation Description
KOR Parameter P26.24
new New value
old Old value
set Check weight
act Measured check weight
Display:
• During first measuring phase, first text field reads "CB: Measurement running",
and first display field shows residual run time in %.
• Second text field displays "Weight"; second display field, current hopper
weight.
• In second measuring phase, with check weight applied or removed, first field
shows the residual run time; second field, the measured check weight value. If
check weight has been removed, value is negative.
• If setting program is complete, first text fields displays "Weight"; first display
field, measured check weight value. If check weight has been removed, value
is negative.
• Second text field displays "Set/Act"; second display field, the ratio between
check weight and measured value.
Special Messages
Message Cause
Aborted! Process aborted; no change.
5 Commissioning
This chapter describes the commissioning of DISOCONT and connected loss-in-
weight feeder. The application is controlled discharge weighing.
Commissioning for fill weighing applications can be derived from the text with very
slight modifications.
Observing the sequence below helps to avoid errors:
1. Testing Control Functions
2. Enter parameters.
3. Calibrate hopper.
5.1 Installation
Depending on equipment supplied, the DISOCONT assemblies come preassembled,
e. g. mounted on scale or in control cubicle.
NOTE: Should you use bought-in items, please see DISOCONT Hardware Manual
BVH-2085 for mounting dimensions and DISOCONT system architecture.
• Total of load cell rated capacities. Parameter P 04.05 "L/C Rated Cap.".
Prerequisites:
2. Set I * R-compensation to 0.
3. Calibrate current limitation to approx. two times the motor rated current.
Prerequisites
2. Enter setpoint.
3. Start scale.
NOTE: No material is required.
4. Read off speed value.
NOTE: Select "Speed" display in normal display using cursor keys.
5. Read off control magnitude value "Service Values" function.
NOTE: Select "Service Values" function in function distributor using cursor
keys.
6. Compute Parameter P 10.18 "Calib.Speed Red." using the following formula:
10. Set Parameter P 04.02 "Speed Charac.Value" in accordance with Spec Sheet.
• Check cabling.
• Switch ammeter into sensor current circuit: If one tooth of measuring wheel
stands before sensor, a value between 0.1 mA and 1.65 mA has to be
measured. In all other cases, measurement value is between 1.65 mA and 8
mA.
• Ambient influences.
Measuring filter is selected as a function of the last two items. Therefore, no generally
valid statement on measuring filter size can be made.
NOTE: "Rule of thumb": Big hoppers and small feed rates require longer filter times.
If no empirical system data are available, we recommend to start with default values.
Setting feed rate controller
1. Calibrate external controller (s. "Calibrating External Controller" item).
• Perform linearization.
4. If need be, start various times: If displayed values are almost equal, result can
be acquired. If values heavily vary, mechanical interference may be given
which has to be removed.
2. With smaller and higher feed rate, call up "DAE Calibration" setting program
various times.
a. highest value
b. medium feed rate value and start adaption (Parameter "DAE Adap." =
YES).
The adaption enables the eliminator to match varying operating
conditions. In some cases, the eliminator can "learn" certain
disturbance patterns which adversely affects elimination.
6 Check
6.1 Starting Check
Use "Check Meas. START" function to acquire the loss-in-weight feeder feed
constancy. After self-check, feed constancy display is normally poorer than in reality.
The reasons are interferences in measuring signal which are, however, not reflected
by the material flow.
NOTE: Used in conjunction with an additional weighing system and with "Check Meas.
START" function activated, DISOCONT can be used as independent check scale.
Measuring Principle
Weight change mean value is acquired in equal-time measuring intervals (e.g. 2 s).
After a certain number of measuring intervals (e.g. 30), measurement is complete and
restarts from the beginning. After every complete measurement, mean feed rate and
feed constancy are acquired. This means that feed constancy is a measure of chance
variation of the material amount fed in defined intervals.
You can print the results as service values or view them in form of a report.
Meaned values are computed using the following formulas:
Print Report
Report is printed if Parameter P 18.03 "Print Event" is set to "YES+CM". Printing takes
place
5. Turn on power.
If the stated resistors are used, the following service values result:
• L/C utilization approx. 75% for 2mV/V load cell characteristic value.
• L/C utilization approx. 53% for 2.85mV/V load cell characteristic value.
If raw measurement value is in specified range, measuring amplifier operates free
from fault.
Measured load display depends on scale rated data.
Note: With other resistors R1 and R2, the following raw measured value results:
Raw measured value ~ 500 * R2 / R1 [mV/V]
If parameter default values are used, display reads approx. 75 kg.
2. Adapt feed rate using the "Vol. Discharge Adaption" setting program. If
discharge characteristic heavily varies, readjust external controller.
• adjust feed rate using the "Vol. Discharge Adaption" setting program
7 Parameters
This chapter discusses the parameters available with DISOCONT and presents a list
of event messages relating to the individual parameters.
Dependencies
There are parameters whose availability depends on other parameters setting values.
These dependencies are stated in the header of every single parameter description.
Abbreviations
Source Description
FB Fieldbus
OP Operator Panel (control unit)
DI Digital input
DO Digital output
AI Analog input
AO Analog output
DI 4 Analog input with low resolution
W1 Warning 1 (acknowledgement required)
W2 Warning 2 (no acknowledgement required)
A Alarm
IG No event message but contact outputs
LC Load cell
LS Logical signal
VSE System unit
VEA Input/output unit
I Feed rate
Q Belt load
V Belt speed
EIO Externe I/O-Einheit
Notes
Inputs/outputs
Number Description
1. Select source DI, DO ...,...
"--" means "not assigned", i.e. function is not
available.
2. Select unit VSE 1 ...
Display only shows units selected in Parameter
Block 1.
3. Select channel number DI 1 ...
4. Select signal level LOW or HIGH (N/C or N/O
contact)
Analog Input DI 4:
Hardware Configuration
Upon parametrization of the hardware used, the source determines whether unit,
channel and level must be additionally indicated or not. The following table applies:
VSE1-VSE3 DI1-DI4
DO1-DO4
EIO DI1-DI8
DO1-DO8
As you can see, with fieldbus (FB), control unit (OP), speed (v), are not assigned (--)
and the low-resolution analog input (DI4) does not require additional specification for
unit, channel or level.
Analog inputs (AI), outputs (AO) and load cell (LC) require the unit to be specified.
Digital inputs (DI), outputs (DO) and logical signals (LS) require unit, channel and level
to be specified.
The external input/output unit (EIO) readies 4 analog inputs and outputs, and 16 digital
inputs and outputs.
Example:
Parameter P 03.02 determines the scale start source.
Description Source
P 03.02 Start FB
Alternatives OP, DI
On standard, the scale is connected via fieldbus (FB). Alternatively, you can select
control unit (OP) or a digital input (DI). If DI is desired, additionally specify active unit
with channel and level (see Possible Hardware Configurations table).
Event messages
The reaction on events can be parametrized using the event classes. As a rule, all
classes (Alarm (A), Warning 1 (W1), Warning 2 (W2) and No Message (IG) can be
set. Therefore, the parameter default value suffices.
Example:
P 06.09 Power Down A Event WE 01
After power failure, event WE 01 is set as Alarm.
01 - Hardware Modules
Number: Name Default Sys ID
P 01.01 Comm.-Error OP IG 4218
P 01.02 VEA-Unit 1 NO 4208
P 01.03 VEA-Unit 2 NO 4209
P 01.04 VEA-Unit 3 NO 4210
P 01.05 VSE-Unit 2 NO 4211
P 01.06 VSE-Unit 3 NO 4212
P 01.07 Comm.-Error VEA1 A 4213
P 01.08 Comm.-Error VEA2 A 4214
P 01.09 Comm.-Error VEA3 A 4215
P 01.10 Comm.-Error VSE2 A 4216
P 01.11 Comm.-Error VSE3 A 4217
P 01.12 External I/O NO 4219
P 01.13 Com. Ext. I/O A 4220
P 01.14 VEA 20101 NO 4221
P 01.15 Com. VEA 20101 A 4222
02 - Scale Definitions
Number: Name Default Sys ID
P 02.01 Language DEUTSCH 4224
P 02.02 Units SI 4225
P 02.03 Control YES 4590
P 02.04 Meas. Direction DOWN 4589
P 02.05 Nominal Feed Rate Io 1000.000 kg/h 4226
P 02.06 Display Formats STANDARD 4228
P 02.07 Feed Rate Units ----.- kg/h 4229
P 02.08 Fill Weight Unit ----.-- kg 4622
P 02.09 Counter 1 Unit -----.- kg 4230
P 02.10 Pulse Length Total. 0.000 s 4231
P 02.11 Counter 2 Unit ------- kg 4232
P 02.12 Counter 3 Unit ----.-- t 4233
P 02.13 Feed Index Active NO 4857
P 02.14 Hot-Key F7 Reset Totalizer 4238
P 02.15 Upper Limit Trend 100.00 % 4235
P 02.16 Lower Limit Trend 0.00 % 4234
P 02.17 Trend Period 1.00 h 4236
DISOCONT Instructions Manual Loss-in-Weight Feeder BV-H2064GB , 0915 65
©Schenck Process
Parameters
03 - Control Sources
Number: Name Default Sys ID
P 03.01 Control Sources STANDARD 4240
P 03.02 Feeder Start FB 4241
P 03.03 Absolute Setpoint FB 4242
P 03.04 Setpoint Range 20.00 mA 4243
P 03.05 Setpoint Offset 4.00 mA 4244
P 03.06 Release -- 4245
P 03.07 Event No Release W2 4246
P 03.08 Relative Setpoint -- 6233
P 03.09 Rel.Setp. Range 20.00 mA 6240
P 03.10 Rel. Setp. Offset 4.00 mA 6241
05 - Scale Controlling
Number: Name Default Sys ID
P 05.01 Volum. Start-Up 0.0 s 4272
P 05.02 Afterfl.Totalizer 3.0 s 4274
P 05.03 START Agitator 30.0 % Io 4572
P 05.04 Nominal Amount Fo 100.0 % LC 4609
P 05.05 Fo Event W2 4611
P 05.06 AMOUNTmin 5.0 % Fo 4610
P 05.07 AMOUNTmin Event W2 4612
P 05.08 Filling Control MIN/MAX 4591
P 05.09 F_CONTROLmin 10.0 % Fo 4613
P 05.10 F_CONTROLmax 90.0 % Fo 4614
P 05.11 Cancel Filling auto. NO 5419
P 05.12 Gate Feedback -- 4615
P 05.13 Gate Feedback Time 3.0 s 4616
P 05.14 Gate Feedback Error A 4618
P 05.15 T_Volumetric 30 s 4617
P 05.16 T_Volum. Event W1 4619
P 05.17 Settling Time 5s 4620
P 05.18 Extended Functions STANDARD 4592
P 05.19 Blow-Out Time 0s 4571
P 05.20 Pulse Filling 1.0 s 4621
P 05.21 Filling Pause 3.0 s 4860
P 05.22 DO Start Prefeeder -- 4435
P 05.23 Gate Delay Time 0s 4940
P 05.24 DO Discharge Gate -- 4942
P 05.25 Echo Discharge Gate -- 4943
P 05.26 Discharge Gate Error A 4944
P 05.27 DO: Clean Filter -- 4948
P 05.28 DO: Bin Ventilation -- 4949
P 05.29 Pulse Bin Ventilat. 1.0 s 4950
06 - Scale Monitoring
Number: Name Default Sys ID
P 06.01 Scale Monitoring STANDARD 4288
P 06.02 Stand-By Event W2 4289
P 06.03 Stand-By Limit Value 0 % Io 4290
P 06.04 Tacho Event A 4291
P 06.05 Error LC Input A 4293
P 06.06 LC Input < MIN A 4294
P 06.07 LC Input > MAX A 4295
P 06.08 Setpoint Limited W1 4296
P 06.09 Power Failure A 4297
P 06.10 Time Deviation 20.0 s 4298
P 06.11 Threshold Deviation 5.0 % 4299
P 06.12 Factor Deviation 1.0 4320
P 06.13 Event Deviation A 4300
P 06.14 Controller Limited W2 4301
P 06.15 Memory Error A 4302
P 06.16 License Violation A 4303
P 06.17 Password 10000 4292
P 06.18 Analog Input< Offset A 5418
07 - Display Filters
Number: Name Default Sys ID
P 07.01 Display Filters STANDARD 4327
P 07.02 T-Differential 3.00 s 4608
P 07.03 I-Display 3.0 s 4328
P 07.04 I-Analog Output 3.0 s 4329
P 07.05 I-Serial Output 3.0 s 4330
P 07.06 F Display 3.0 s 4636
P 07.07 N Display 3.0 s 4637
P 07.08 Deviation 3.0 s 4333
P 07.09 LC Filter 0.25 s 4334
08 - Limit Values
Number: Name Default Sys ID
P 08.01 Limit Values STANDARD 4336
P 08.02 Value for I-Min 5.0 % Io 4337
P 08.03 Event Class I-Min W1 4338
P 08.04 Value for I-Max 120.0 % Io 4339
P 08.05 Event Class I-Max W1 4340
P 08.06 F-Min Value 0.0 % LC 4624
P 08.07 Event Class F-Min W1 4626
P 08.08 F-Max Value 120.0 % LC 4627
P 08.09 Event Class F-Max W1 4629
P 08.10 N-Min Value 5.0 % n 4630
P 08.11 Event Class N-Min W1 4632
P 08.12 N-Max Value 120.0 % n 4633
P 08.13 Event Class N-Max W1 4635
09 - Calibration Data
10 - Controller
Number: Name Default Sys ID
P 10.01 P-Component KP 0.92308 4369
P 10.02 I-Component TN 7.0 s 4370
P 10.03 Bypass 10.00 mA 4375
P 10.04 Contr. Magn. Offset 4.00 mA 4373
P 10.05 Controller Functions STANDARD 4361
P 10.06 Lower Limit 4.00 mA 4371
P 10.07 Upper Limit 20.00 mA 4372
P 10.08 Position at STOP 0 4374
P 10.09 Store NO 4376
P 10.10 Contr. Outp. Storage 3s 4573
P 10.11 Material Flow Comp NO 4593
P 10.12 Setp. Filter 2nd Ord 0.25 s 4379
P 10.13 Setpoint Adaptation YES 4640
P 10.14 KP Adaptation 1.00 4644
P 10.15 Speed Transducer NO 4641
P 10.16 P-Comp. KPn 0.50 4574
P 10.17 I_Comp. TNn 1.5 s 4575
P 10.18 Calib.Speed Red. 0.0100 mA/(1/min) 4576
P 10.19 Controller Index 1 4923
P 10.20 Controller Adaptat. NO 5464
P 10.21 CORR. Meas.Time 30 s 4587
P 10.22 Bypass Adaptation 1.000 5653
11 - Linearization
Number: Name Default Sys ID
P 11.01 Linearization ON NO 4577
P 11.02 Lin. Y1 15.00 % 4578
P 11.03 Lin.-I1 5.0 % Io 4579
P 11.04 Lin. Y2 30.00 % 4580
P 11.05 Lin.-I2 15.0 % Io 4581
P 11.06 Lin. Y3 50.00 % 4582
P 11.07 Lin.-I3 35.0 % Io 4583
P 11.08 Lin. Y4 100.00 % 4584
P 11.09 Lin.-I4 100.0 % Io 4585
P 11.10 Lineariz. Error W2 4586
12 - Fuzzy DAE
Number: Name Default Sys ID
P 12.01 DAE ON NO 4560
P 12.02 Adaptive DAE NO 4561
P 12.03 Fuzzy MIN 10.0000 kg/h 4562
P 12.04 Fuzzy Factor 10.0 4563
P 12.05 Fuzzy Mean 0.50 4564
P 12.06 Fuzzy Controller 1.0 4565
P 12.07 Fuzzy Tracking 1.5 s 4566
P 12.08 DAE Event W2 4567
P 12.09 DAE Fault Event W1 4568
13 - Analog Outputs
Number: Name Default Sys ID
P 13.01 Analog Outputs STANDARD 4384
P 13.02 Setpoint -- 4385
P 13.03 Setpoint Offset 4.00 mA 4386
P 13.04 Setpoint Range 20.00 mA 4387
P 13.05 Actual Feed Rate -- 4388
P 13.06 Feed Rate Offset 4.00 mA 4389
P 13.07 Feed Rate Range 20.00 mA 4390
P 13.08 Fill Weight -- 4646
P 13.09 Fill Weight Offset 4.00 mA 4647
P 13.10 Fill Weight Range 20.00 mA 4648
P 13.11 Speed -- 4651
P 13.12 Speed Offset 4.00 mA 4649
P 13.13 Speed Range 20.00 mA 4650
P 13.14 Deviation -- 4397
P 13.15 Deviation Offset 4.00 mA 4398
P 13.16 Deviation Range 20.00 mA 4399
P 13.17 Controller Magnit. Y AO 4400
14 - Digital Inputs
Number: Name Default Sys ID
P 14.01 Digital Inputs STANDARD 4416
P 14.02 Error Ext. Event 1 A 4417
P 14.03 DI Ext. Event 1 DI 4418
P 14.04 Error Ext. Event 2 A 4430
P 14.05 DI Ext. Event 2 DI 4431
P 14.06 DI Acknowl. Events -- 4419
P 14.07 DI Local Mode -- 4420
P 14.08 DI Volumetric ON -- 4421
P 14.09 NAMUR Error VSE1-DI3 A 4424
P 14.10 NAMUR Error VSE1-DI4 A 4425
P 14.11 NAMUR Error VSE2-DI3 A 4426
P 14.12 NAMUR Error VSE2-DI4 A 4427
P 14.13 NAMUR Error VSE3-DI3 A 4428
P 14.14 NAMUR Error VSE3-DI4 A 4429
P 14.15 DI 1: Feed Index -- 4858
P 14.16 DI 2: Feed Index -- 4859
P 14.17 Error Ext. Event 3 IG 4730
P 14.18 DI Ext. Event 3 -- 4731
P 14.19 Error Ext. Event 4 IG 4732
P 14.20 DI Ext. Event 4 -- 4733
P 14.21 DI Volum. Sync. ON -- 4941
P 14.22 DI:Filling ON/OFF -- 4945
P 14.23 DI:Discharge ON/OFF -- 5420
P 14.24 DI:Reset Totalizer 1 -- 5414
P 14.25 DI:Reset Totalizer 2 -- 5415
P 14.26 DI 3: Feed Index -- 5649
P 14.27 DI 4: Feed Index -- 5650
P 14.28 DI 5: Feed Index -- 5651
P 14.29 DI 6: Feed Index -- 5652
15 - Digital Outputs
Number: Name Default Sys ID
P 15.01 Digital Outputs STANDARD 4432
P 15.02 DO Feeder Start DO 4433
16 - Batch Mode
Number: Name Default Sys ID
P 16.01 Batch Mode NO 4448
P 16.02 Batch Setp. Source FB 4449
P 16.03 Adaptation Mode Ramp 5426
P 16.04 Correction Amount 0.000000 kg 4451
P 16.05 Adaptation Factor 0.50 4452
P 16.06 Automatic Printing NO 4453
P 16.07 DI Batch Terminate -- 4454
P 16.08 DO Batch is Running -- 4455
P 16.09 DO Dribble Feed -- 4456
P 16.10 DO Full Feed -- 4457
P 16.11 Stock Filling NO 4645
P 16.12 Analog Setp. Relat. 1000.000 kg 4936
P 16.13 Batch Setp. Range 20.00 mA 4937
P 16.14 Batch Setp. Offset 4.00 mA 4938
P 16.15 Adaptation Time 3.00 s 4450
P 16.16 Adapt. Start Value 300.0 % Io 5382
P 16.17 Time Dribble Feed 2 0.0 % 5428
P 16.18 Value Dribble Feed 2 0.0 % 5427
P 16.19 DO Dribble Feed 2 -- 5429
P 16.20 Batch Tolerance 100000.000000 kg 4458
P 16.21 Out of Tolerance W2 4459
P 16.22 Error Mat. Amount W1 5424
P 16.23 DO: Mat. Amount ! -- 5441
17 - Process Control
Number: Name Default Sys ID
P 17.01 Process Control STANDARD 4464
P 17.02 Maintenance Elec. 3000 h 4465
P 17.03 Event Maint. EL. IG 4466
P 17.04 Maint. Feeder Run. 3000 h 4467
P 17.05 Ev.Maint Feeder Run. IG 4468
P 17.06 Check Meas.Time 60 s 4638
P 17.07 Check Meas. No. 30 4639
18 - Printer
Number: Name Default Sys ID
19 - Comm. EasyServe
Number: Name Default Sys ID
P 19.01 Own Address 1 4520
P 19.02 EasyServe Baudrate 9600 4521
P 19.03 EasyServe Diagnose 0 4522
P 19.04 Flag 1 0 5444
P 19.05 Flag 2 0 5445
P 19.06 Format Data 8-O-1 4523
P 19.07 Connection Serial 4526
P 19.08 Modbus Idle Time 4 ms 4527
20 - Comm. Fieldbus
Number: Name Default Sys ID
P 20.01 Protocol Type NO 4528
P 20.02 Timeout Host 10 s 4529
P 20.03 Comm.-Error Host A 4530
P 20.04 Station Address Host 1 4531
P 20.05 Modbus Diagnose 0 4532
P 20.06 Resolution 4096 4533
P 20.07 Modbus-IEEE-Format IEEE:std / LONG:std 4534
P 20.08 Modbus Baudrate 19200 4535
P 20.09 Modbus Format Data 8-O-1 4656
P 20.10 S5-Diagnose 0 4536
P 20.11 S5-Float-Format SIEMENS-KG 4537
P 20.12 S5-Baudrate 9600 4538
P 20.13 S5 Format Data 8-E-1 4657
P 20.14 PB-DP Address 10 4539
P 20.15 PB-DP-FLOAT-Format IEEE 4540
P 20.16 PB-DP-Parameter NO 4658
P 20.17 PB-DP-ID-Count 6 4659
P 20.18 DeviceNet Address 63 4541
P 20.19 DeviceNet Baudrate 125K 4542
P 20.20 SE-Bus Address 33 4543
P 20.21 IB-FLOAT-Format SIEMENS-KG 4686
P 20.22 IB-Effective Data NO PARAM / 2 ID 4685
P 20.23 PB-DP-Set-Val-Count 2 Preset IDs 4734
P 20.24 DVN-Parameter NO 4780
P 20.25 DVN-ID-Count 6 4779
P 20.26 DVN-Set-Val-Count 2 Preset IDs 4781
P 20.27 DVN-Byte Sequence Low - High 4924
P 20.28 Word Sequence IEEE:std / LONG:std 5474
P 20.29 WEB Coding XML 6228
P 20.30 DHCP NO 6229
P 20.31 IP Address 1 192 6216
P 20.32 IP Address 2 168 6217
P 20.33 IP Address 3 240 6218
P 20.34 IP Address 4 1 6219
P 20.35 Net Mask 1 255 6220
P 20.36 Net Mask 2 255 6221
P 20.37 Net Mask 3 255 6222
P 20.38 Net Mask 4 0 6223
P 20.39 Gateway 1 0 6224
P 20.40 Gateway 2 0 6225
P 20.41 Gateway 3 0 6226
P 20.42 Gateway 4 0 6227
P 20.43 Byte Sequence High - Low 6231
DISOCONT Instructions Manual Loss-in-Weight Feeder BV-H2064GB , 0915 71
©Schenck Process
Parameters
21 - PLS Outputs
Number: Name Default Sys ID
P 21.01 PLS Binary OUT 1 -- 4662
P 21.02 PLS Binary OUT 2 -- 4663
P 21.03 PLS Binary OUT 3 -- 4664
P 21.04 PLS Binary OUT 4 -- 4665
P 21.05 PLS Binary OUT 5 -- 4666
P 21.06 PLS Binary OUT 6 -- 4667
P 21.07 PLS Binary OUT 7 -- 4668
P 21.08 PLS Binary OUT 8 -- 4669
P 21.09 PLS Analog OUT 1 -- 4670
P 21.10 PLS Analog OUT 2 -- 4671
22 - Interlocking
Number: Name Default Sys ID
P 22.01 DI Error Mechanics 1 -- 4760
P 22.02 DI Error Mechanics 2 -- 4761
P 22.03 DI Error Mechanics 3 -- 4762
P 22.04 DI Error Mechanics 4 -- 4763
P 22.05 DI Error Mechanics 5 -- 4764
P 22.06 DI Error Electr. 1 -- 4765
P 22.07 DI Error Electr. 2 -- 4766
P 22.08 DI Error Electr. 3 -- 4767
P 22.09 DO Error Mechanics -- 4768
P 22.10 Error Mechanics W1 4769
P 22.11 DO Error Electricity -- 4770
P 22.12 Error Electricity W1 4771
P 22.13 DO Error Mechatr. 1 -- 4772
P 22.14 DO Error Mechatr. 2 -- 4773
P 22.15 Error Mechatronics W1 4774
P 22.16 DO Ready -- 4775
P 22.17 Not Ready W1 4776
P 22.18 DO Ready for Start -- 4777
P 22.19 Not Ready for Start W1 4778
P 22.20 LS_1 AND-Gate 1 -- 5376
P 22.21 LS_2 AND-Gate 1 -- 5377
P 22.22 Error AND-Gate 1 W1 5378
P 22.23 LS_1 AND-Gate 2 -- 5379
P 22.24 LS_2 AND-Gate 2 -- 5380
P 22.25 Error AND-Gate 2 W1 5381
P 22.26 DO: AND-Gate 1 -- 5416
P 22.27 DO: AND-Gate 2 -- 5417
P 22.28 LS TIME-Gate 1 -- 5520
P 22.29 Delay TIME Gate 1 0.0 s 5521
P 22.30 Pulse TIME Gate 1 10.0 s 5522
P 22.31 Active at OFF:TIME 1 YES 5523
P 22.32 DO: TIME Gate 1 -- 5524
P 22.33 LS TIME-Gate 2 -- 5525
P 22.34 Delay TIME Gate 2 0.0 s 5526
P 22.35 Pulse TIME Gate 2 10.0 s 5527
P 22.36 Active at OFF:TIME 2 YES 5528
P 22.37 DO: TIME Gate 2 -- 5529
26 - Bin Weigher
Number: Name Default Sys ID
P 26.01 Bin Weigher Active NO 4704
P 26.02 Load Measurement -- 4705
P 26.03 LC Charac. Value 2.0000 mV/V 4706
P 26.04 LC Rated Cap. 1000.000 kg 4707
P 26.05 LC Filter 0.25 s 4708
P 26.06 Bipolar Measuring NO 4712
P 26.07 Error LC Input W1 4709
P 26.08 LC Input > MAX W1 4710
P 26.09 Nominal Bin Load 100.0 % LC 4711
P 26.10 Display Format ---.--- t 4672
P 26.11 Display Filter 3.0 s 4713
P 26.12 Control Level MIN 60.0 % 4714
P 26.13 Control Level MAX 70.0 % 4715
P 26.14 DO Bin Filling -- 4716
P 26.15 Bin Level MIN 5.0 % 4717
P 26.16 Event Bin Level MIN W1 4718
P 26.17 DO Bin Level MIN -- 4719
P 26.18 Bin Level MAX 120.0 % 4720
P 26.19 Event Bin Level MAX W1 4721
P 26.20 DO Bin Level MAX -- 4722
P 26.21 AO Bin Load -- 4723
P 26.22 AO Offset 4.00 mA 4724
P 26.23 AO Range 20.00 mA 4725
P 26.24 Range Correction 1.0000 4726
P 26.25 Tare 0.000 kg 4727
P 26.26 Check Weight 10.00 kg 4728
P 26.27 Control. in OFF-Mode NO 4755
P 26.28 DI: Bin Load Sensor -- 5401
P 26.29 Bin Load MAX Sensor W1 5402
27 - Safety Functions
Number: Name Default Sys ID
P 27.01 Pulv. Coal Feeder NO 4955
P 27.02 Source Emerg. Setp. -- 4930
P 27.03 Emergency Setpoint 0.0 kg/h 4931
P 27.04 Setpoint Step + 300.0 % Io 4932
P 27.05 Setpoint Step - 300.0 % Io 4933
P 27.06 Reset Setpoint 1.0 4934
P 27.07 If OFF: Reset Setp. NO 4939
P 27.08 Scale Check FC NO 4956
P 27.09 FC: Speed -- 4957
P 27.10 FC: Delay-Time 10.0 s 4958
P 27.11 FC:Tolerance at 100% 40.0 % 4959
P 27.12 FC:Tolerance at 50% 20.0 % 4960
P 27.13 FC:Tolerance at 0% 20.0 % 4961
P 27.14 FC: Speed MIN 1.0 % 4962
P 27.15 FC: Speed < MIN A 4963
P 27.16 FC: MIN Limit W1 4964
P 27.17 FC: MAX Limit A 4965
P 27.18 FC: DO MAX Limit -- 4966
P 27.19 FC: DO MIN Limit -- 5398
28 - Dead Time
Number: Name Default Sys ID
P 28.01 Dead Time Active NO 5403
P 28.02 Dead Time 0.00 s 5404
P 28.03 Setpoint Select -- 5405
P 28.04 Setpoint Clock ON -- 5406
P 28.05 ON/OFF Select -- 5407
P 28.06 ON/OFF Clock ON -- 5408
P 28.07 Time Elem. Preassign -- 5409
P 28.08 Time Elements Init. -- 5410
P 28.09 DO Dead Time Active -- 5411
P 28.10 DO Setpoint Active -- 5412
P 28.11 DO ON/OFF Active -- 5413
50 - Feed Index 2
Number: Name Default Sys ID
P 50.01 Nominal Flow Rate Io 1000.0 kg/h 6464
P 50.02 Nominal Amount Fo 100.0 % LC 6465
P 50.03 F_CONTROLmin 10.0 % Fo 6466
P 50.04 F_CONTROLmax 90.0 % Fo 6467
P 50.05 F-Max Value 120.0 % LC 6468
P 50.06 Tare 0.00 kg 6469
P 50.07 T-Differential 3.0 s 6470
P 50.08 Fuzzy MIN 10.00 kg/h 6471
P 50.09 P-Component KP 0.92308 6472
P 50.10 I-Component TN 7.0 s 6473
P 50.11 Bypass 10.00 mA 6474
P 50.12 Contr. Magn. Offset 4.00 mA 6475
P 50.13 Controller Index 1 6476
P 50.14 Lin. Y1 15.00 % 6477
P 50.15 Lin. I1 5.0 % Io 6478
P 50.16 Lin. Y2 30.00 % 6479
P 50.17 Lin. I2 15.0 % Io 6480
P 50.18 Lin. Y3 50.00 % 6481
P 50.19 Lin. I3 35.0 % Io 6482
P 50.20 Lin. Y4 100.00 % 6483
P 50.21 Lin. I4 100.0 % Io 6484
P 50.22 Setpoint Range 20.00 mA 6485
P 50.23 Flow Rate Range 20.00 mA 6486
P 50.24 Fill Weight Range 20.00 mA 6487
P 50.25 START Agitator 30.0 % Io 6488
P 50.26 Correction Amount 0.0000 kg 6489
P 50.27 Bypass Adaptation 1.000 6490
51 bis 98 - Förderindex 3 bis 50
Alle Parameter entsprechen Parametergruppe 50.
Die SysID eines Parameters von Förderindex n = SysID des Parameters von
Förderindex 2 + (32 * (n-2)) für n > 2 und n < 50
External I/O expansion (EIO) for additional digital and analog inputs/outputs
To equip VSE base card with additional I/O, extension card VEA 20101 is available.
Plugged on the base card fieldbus connector, the extension card offers the following
additional inputs/outputs on VSE 1:
Analog output A02
Analog input AI1
Digital inputs DI5, DI6 and DI7
Digital outputs DO5, DO6 and DO7
Output DO7 can also be used for pulse output.
NOTE:
After start-up, plugged-on card is automatically identified and activated.
Select DISOCONT dialog langue. OTHERS let you use your own texts that can be
created using EasyServe.
Change over displays and parameter inputs from SI units to the American metric
system (NON-SI). Numerical values entered are automatically converted.
The table below shows the conversion from one unit system into the other:
NON-SI unit SI-unit Conversion
pound lb Kilogramm kg 1 lb = 0.453593 kg
ton t Tonne t 1 t = 0.907185 t = 2000 lb
feet f Meter m 1 f = 0.3048 m
inch " Millimeter mm 1" = 25.4 mm
This table equally applies to combined units, e.g. kg/hr.
DISOCONT Instructions Manual Loss-in-Weight Feeder BV-H2064GB , 0915 77
©Schenck Process
Parameters
Nominal flow rate is the scale characteristic value used as reference for limit values
and service displays.
Determine whether standard or user specific display formats are to be used. Preset
standard display formats are matched to scale depending on nominal flow rate .
Normally, display formats suit the practical application.
Lets you display format of flow rate actual value and setpoint.
Display format for counter 1 and pulse weighting for external counter.
See also section Details: Pulse output.
NO:
Feed index 1, no switch-over possible, OP indication "FI" is hidden.
OP:
Presetting of feed index via keyboard.
DI:
Presetting of feed index via a max. of 6 dig. inputs
(P 14.14 und P 14.16, P14.26 bis P14.19).
FB:
Presetting of feed index via field bus.
Note:
The feed index may be modified only if the scale has been switched off!
The trend is a graphical representation of measuring results over the time displayed
on control unit VLB.
The resolution is 50 * 100 pixels (value, time).
See Operating Functions chapter, Trend item.
I:
Feed rate
F:
Fill weight
W:
Setpoint
B:
Bin weigher fill weight (Block 26)
Xd:
Deviation
Y:
Control magnitude
Totalizing counter 1 pulse output can alternatively be output via digital output.
Default value "---" uses the pulse output on VEA 1. The "DO" alternative uses the
configured output.
Pulse time is determined by Parameter P02.08 now as before. Values below 10ms
totally block output, and values up to 1 second are set to "High" for 1 second.
Parameter blocks for feed indices bigger than P02.21 are hidden at the operating
console and by EasyServe.
P 02.18 (Codepage) selects the character set to be used by the operator panel VLB.
The change of the character set is possible only with software VLB 20150-05 or
higher. After switching to the Cyrillic character set, characters above the normal ASCII
set will be shown as Cyrillic characters on the VLB. Special German characters and
Cyrillic characters cannot be shown at the same time.
Determine whether default or user specific parameter values are to be used for control
source configuration.
Maximum input current for 100% analog setpoint. The range and elevation parameters
are effective only if Parameter P03.03 "Absolute Setpoint" is set to A1 or DI4.
Elevates input current for 0% nominal feed rate setpoint. Active only if Parameter P
03.03 "Setpoint" is set to AI or DI4.
--
no percent evaluation of demand values.
OP
Percent evaluation via keyboard
AI, DI4
percent evaluation via analog input.
Only the absolute demand value is active in keyboard mode or if parameter P03.03
(preselection absolute demand value) is at OP.
Increase of the input current to the analog relative demand value of 0%.
The parameter is only active if P03.08 is at Ai or DI4.
During this period of time, after scale stop, the amount fed out is still acquired.
Limit value for agitator start-up. Agitator starts 30 seconds after setpoint has exceeded
threshold in ON state of prefeeder. Prefeeder cut-off immediately stops agitator.
Indicates the maximum hopper capacity. Value serves as reference for relative fill
weight display, Parameters P 05.07 "LIFTmin", " Parameter P 05.09 F-CONTROLmin"
and analog output.
Minimum material amount in hopper considered for control. Between values Nominal
Lift Fo and LIFT min, control is gravimetric, outside, always volumetric.
Until software version VLW20150-10, automatic filling is cut off below LIFTmin. Filling
can be started only using the "Start Filling" function. From version VLW 20150-11, see
Parameter O05.33.
Events "event Fo" and "event LIFTmin" do not affect this behaviour.
See Parameter P05.33 "LIFTmin Initial Filling".
MIN/MAX:
Controls filling process using limit values of parameters P 05.09 "F_Controlmin", P
05.10 "F_Controlmax".
PULSE:
Start filling process with P 05.09 "F_Controlmin" for the time set in P 05.20 "Pulse
Filling". Aborts at latest with limit value P 05.10 "F_Controlmax". Pulse filling also acts
on the "Filling" menu function.
PULSES:
Controls filling process using limit values "F-CONTROLmin." and "F-CONTROLmax" .
Unlike the MIN/MAX setting, the fill signal is output in form of a pulse series settable
with P 05.20/P 05.21.
NO:
No gate control, output is set to "Gate CLOSED". Menu function "START Filling" is
ineffective.
Control is active only in turned-on state of scale. After cut-off, active filling operation is
run to completion.
In case of alarm, filling aborts immediately.
If the scale has been switched on and the filling weight falls below this value, filling is
started.
If the values are smaller than 0 or smaller than the parameter P 05.06 "HUBmin" the
filling control is not activated.
If "Cancel Filling auto." has been selected, scale automatically terminates filling
process after elapse of maximum filling time (P05.15) and goes to discharge mode.
Discharge mode can be output via contact P15.21, say for control of a hooter.
See also P14.23 " DI:Discharge ON/OFF" digital input.
Setting "--" means that no feedback is required. If setting is maintained, no inputs for
unit, channel and level are necessary.
If a digital input is used for feedback, HIGH level means that gate is open.
Time portion in filling process during which control still runs in volumetric mode after
filling.
Hopper blow-out starts 2s before opening of feed gate and ends after set time after
gate closing.
If Parameter P 02.04 "Meas. Direction" is set to "UP", no hopper blow-out takes place.
Active only if Parameter P 05.08 "Gate Control" has been set to "PULSE" or
"PULSES".
Active only if Parameter P 05.08 "Gate Control" has been set to "PULSES" for pulse-
pause filling.
Gate delay time >0 causes the fill gate to remain open after filling until prefeeder is cut
off.
Contact is set upon start of filling, and reset with Gate CLOSED after filling.
Note:
Below this limit value, automatic fill control is inactive. Initial filling can be started only
using the "Start Filling" function. This helps to avoid uncontrolled material flow into the
bin in case of critical materials.
Event LO 08 (P05.07).
Function: :
As long as the contact is existing, any filling command is ignored. Ongoing filling is
finished.
Respective event see P05. 37
Determine whether default values or user specific parameter values are to be used for
scale monitoring.
Time during which the deviation may exceed the limit determined by "Deviation
Threshold" parameter.
See also "Deviation Factor" parameter.
If the deviation absolute value exceeds threshold P 06.11(12) for time P 06.10 , event
message HI 5 (P 06.13) is output.
At 100% setpoint, the effective threshold should be equal to Parameter P 06.11. For
smaller setpoints, threshold can be reduced using Parameter P 06.12.
P 06.12 = 0 : Effective threshold = P 06.11 * Setpoint/nominal value
P 06.12 = 1 : Effective threshold = P 06.11
2. Electronics error
Check external feed rate controller and motor cablings. Check feed controller
for proper setting (current limitation, speed range).
3. Calibration error
During initial calibration, controller was set so critically that smallest changes
of system properties cause unreliable operation.
Action: Repeat this commissioning step.
Change the password protecting parameters, calibrating functions, etc. from access
through the control unit.
Changed password is displayed in encoded form. Default password 7353 results in
return display 10 000.
Password forgotton:
Tell the Schenck Prosses service the value of Parameter P 06.17, or change
password using EasyServe.
Determine if default values or user defined values of display filter parameters are to be
used
Differentiator filter value used to compute feed rate from measured weight values. In
some few cases, value has to be adjusted empirically.
If parameter value changes, reoptimize feed rate controller.
Filter for feed rate display and output on operator panel, EasyServe and all fieldbuses
(except SEBUS).
Filter for serial output via SEBUS (see "Protocol Type" parameter)
Deviation display
Load cell filter acts on all load cell dependent measurement values.
Determine whether default values or user specific parameter values are to be used for
limit value messages.
Digital outputs for limit value messages report excess of MIN/MAX values independent
of event class.
Limit values are monitored only in turned-on state of scale. Monitoring starts 10s after
start of scale.
Minimum fill weight value. Reference: Load cells rated capacities (Parameter "L/C
Rated Cap.").
Maximum fill weight value. Reference: Load cell rated capacity. (Parameter "L/C
Rated Cap.").
The parameter determines wether the program "set nominal feed rate" previously
manually controlled or automatic calibration of the nominal feed rate is used.
Determine if default values or user defined parameter values for controller functions
are to be used.
In stop state of scale, control magnitude can be set either to 0 or to the elevation value
set by Parameter P 10.06 "Lower Limit".
Store last value of control magnitude memory, after scale stop. Next start uses this
values.
NO : No storage
YES : Store
YES-A : Store only if scale has not been stopped by alarm.
Alarm in stop state of scale does not influence stored value.
As a rule, speed controller is reset upon stop.
Controller may be activated only with speed controlled feed units and connected
speed measuring system.
Speed controller is active in volumetric and gravimetric mode.
Parameter acts on Feed Index 1 only (for feed indices 2-4, see Blocks 23-25).
Used to change over the range of an external feed rate controller together with
Parameter P15.19 "DO: Contr. Index 2" Index = 2 activates digital output "DO: Contr.
Index 2".
YES:
Automatically adjusts controller in turn-on state of feeder. Internally stored for each
feed index, the acquired adaption factor is displayed as service value and maintained
also after power failure. Automatic acquisition stops if calibrating program is running or
scale is in volumetric mode. Calibrating programs "Volum. Discharge Adaption" and
"Set Nominal Feed Rate" set the adaption factor to neutral value 1.
The adaption factor can be displayed as service value and assume values between
0.33 and 3.0. Values outside this range are rejected.
Scale uses the acquired adaption factors, but automatic acquisition is stopped.
PASSIVE:
Scale uses the acquired adaption factors, but automatic acquisition is stopped.
NO:
Controller adaption is cut off. All adaption factors assume neutral start value 1.0.
The automatic adaption acquires the prefeeder's feed behaviour over the set period.
Measurement stops for an equally long time. If the adaption stops (conditons not met),
controller adaption restarts after a break of approx. the triple adaption time.
The linearization function lets you linearize the relation between controller control
magnitude and prefeeder.
Set parameters in manual or use the "Linearization" calibrating program.
Linearization point 1:
Controller control magnitude for feed rate LIN-I1.
Linearization point 1:
Check amount read off from DISOCONT counter divided by the measuring time.
Linearization point 2:
Controller control magnitude for feed rate LIN-I2.
Linearization point 3:
Controller control magnitude for feed rate LIN-I3.
Linearization point 4:
Controller control magnitude for feed rate LIN-I4.
Start/stop adaption.
Adaption is used to adjust the eliminator to the normal interference on scale which
must not be faded out.
The natural dynamics of the control upon of disturbances in material flow and software
changes must be ensured. Control and faults to be faded out are decoupled from one
another with the use of the "Fuzzy Reg." parameter.
Big values produce strong decoupling, but also weaker fade-out during the control
process.
Used to monitor the elimination intensity time integral. Strong eliminations are more
liable to fault message output than weak eliminations.
The monitoring function is designed to ensure system safety through cut-off or
extension of elimination thresholds.
Determine whether default values or user specific parameter values are to be used for
analog outputs.
In cut-off state of scale, all analog outputs are set to the value of the particular
elevation.
Analog output source for fill level. Bezugswert ist der Nenn-Hub Fo.
Determine whether default values or user specific parameter settings are to be used
for digital inputs.
Input 1 for external fault signal. Linked with internal fault logic (Block: Interlocking).
Input 2 for external fault signal. Linked with internal fault logic (Block: Interlocking).
Local control unit feedback signal reports that mode has been switched to "Local".
DISOCONT operates as display unit only. To suppress event messages, it is
automatically set to "Volumetric" mode. Upon reset, DISOCONT cuts off.
see P14.15
Input 3 for external fault signal. Linked with internal fault logic (Block: Interlocking).
Input 4 for external fault signal. Linked with internal fault logic (Block: Interlocking).
Note:
Not active in Local or Discharge modes.
Positive signal edge starts filling if no filling operation is active, or stops active filling
operation.
NOTE:
Positive signal edge starts discharging if no discharge operation is active, or stops
active discharge operation.
Digital input used to reset totalizing counter 1. The positive edge is active.
Digital input used to reset totalizing counter 2. The positive edge is active.
see P14.15
see P14.15
see P14.15
see P14.15
Determine whether default values or user specific parameter settings are to be used
for digital outputs.
NOTE:
See Parameter P 05.03.
Digital output for agitator START/STOP.
118 BV-H2064GB , 0915 DISOCONT Instructions Manual Loss-in-Weight Feeder
© Schenck Process
Parameters
Digital output signal output when minimal flow rate (P08.02) is exceeded down.
Contact output is independent of event class.
Digital output signal output when maximum flow rate (P08.04) is exceeded up.
Contact output is independent of event class.
Digital output signal if minimum fill weight (P08.06) value is exceeded down.
Digital output signal used to report shortfall of speed MIN value (P08.10)
unterschritten wird.
Contact output is independent of event class.
Shifts the start of the adaption time by the correction amount. Adaption time = 0
corresponds to a pre-cut-off point.
Upon commissioning, the correction amount should be 0.
Start of tracking time automatically adapts the cut-off function, so that system is nearer
to real conditions upon next batch.
Adaption factor = 0 : No adaption
Adaption factor = 1 : Full adaption
Intermediate values lead to filtered adaption which is to be preferred with systems with
inaccurate repeat behaviour.
The adaption result enters into the Correction Amount parameter.
YES:
Automatic printout after every complete batch .
NO:
Batch printout is possible only via a control menu.
Printout is possible only if batch has been terminated automatically or in manual.
Full feed signal is output from feed start to end of adaption time. Feeding continues in
dribble feed.
Reference value used to parametrize the "Batch Setpoint" analog input. (Source P
16.02 = AI or DI4)
Input current for batch setpoint 0. With negative values, the input range can be
expanded, e.g.
P 16.12 = 1000 kg
P 16.13 = 20mA
P 16.14 = -20mA
0...20mA correspond to 500 ... 1000 kg
Note:
Determines the duration of the entire dribble feed phase
Bezug: P16.15
Bezug: P16.16
If batch is out of tolerance, the correction amount maximally changes by the set
tolerance value during adaption.
Determine whether default values or user specific parameter settings are to be used
for process control.
NO :
No printout.
YES :
Every event is automatically printed the moment it occurs.
YES + CM:
Same as with "YES", however, additional measurement value output for external
evaluation on PC.
Station addresses and baud rates of scale and EasyServe must be identical.
Settings (including the COM interface) can be searched using EasyServe (Menu:
Extra/Options/Communication).
The station address is specially designed for systems with Service bus. If there is no
Service bus, select address 1.
Baud rate
Note:
Scale does not evaluate this parameter.
Parameter can be used for fail-safe storage of user-specific characteristic.
Lets you freely select message end-of-text character for Modbus driver.
According to the Modbus standard, the idle time is 3.5 digits depending on baud rate.
For setting details, see Manual BVH2104.
4ms value fits 9600 baud rate. For other speeds, calculate and enter correct time.
Faulty input can increase fieldbus error rate.
Note:
It may be necessary to key in longer times with modem connections, although you
should normally work with the original value of 4 ms (the standard value for 9,600
baud).
Activate various diagnostic stages. Zero means that diagnostics is not active.
Baud rate
Activates various diagnostic stages. Zero means that diagnostics is not active.
Format indication for all setpoints, measurement values and floating-point parameters.
Baud rate
Attention!
Active only after a 30-second POWER DOWN.
Slave address on Profibus
Format indication for all setpoints, measurement value and floating-point parameters.
Attention!
Active only after a 30-second POWER DOWN.
Select whether user data package includes parameter block or not.
Attention!
Active only after a 30-second POWER DOWN.
Select optional measurement and status values (scale --> Master).
Attention!
Parameter is active only after a 30-second power down.
Slave address on DeviceNet.
Attention!
Parameter is active only after a 30-second power down.
Baud rate.
Attention!
Active only after a 30-second POWER DOWN.
Attention!
Active only after a 30-second POWER DOWN.
Attention!
Active only after a 30-second POWER DOWN.
Attention!
Active only after a 30-second POWER DOWN.
Attention!
Active only after a 30-second POWER DOWN.
The complete interlock circuitry consists of a big interlock block and two smaller
blocks.
1. Big block P22.01...P22.19
The entire interlock circuitry comprises 1 big and 2 smaller interlock blocks.
The load cell filter acts on all measurement values depending on measured load.
NO :
Measurement value 0...175% of load cell rated capacity (2mV/V).
YES :
Measuring range -175%...175% of load cell rated capacity
Since the A/D converter resolution is higher in case of "NO", "YES" should be used
only in special cases (e.g. if measuring eyes are used).
Indicated in percent of load cell rated capacity (P 26.04), nominal bin load serves as
reference value for limit values and analog outputs.
Filter applies to analog, or serial, output, however, not to limit values and control
contacts.
MIN/MAX levels can be used to control a fill unit (output P 26.14). Fill unit stops if MIN
value is reached, and cuts off if MAX value is reached.
Serving for correction of measuring result, parameter is automatically set by the "CB:
Weight Check" setting program.
Setting program "TB: Tare" automatically acquires tare and enters value into
parameter.
Enter relevant check weight for the "CB: Weight Check" setting program.
Determines whether fill weight (P26.12 and P26.13) and bin control (Block: Bin
Control) are active always or only in turned-on state of scale.
Fill weight sensor digital input. If sensor responds, filling is suppressed or aborted for
60s.
1. DO (P 26.14) OFF
2. DO (P 27.04) OFF
For safety reasons, pulverized coal feeding does not allow for certain parameter
settings. For details, see "Pulverized Coal Feeder" item in the Appendix.
YES:
Upon cut-off of feeder, keyed-in setpoint is set to zero.
Dead time elements for setpoint and ON/OFF command are available and can be
activated separately.
NO :
No dead time active
Setpoint :
Only setpoint dead time active
ON/OFF :
Only ON/OFF dead time active
Setpoint + ON/OFF:
Setpoint and ON/OFF dead times are active.
Time elements can be assigned from outside with available setpoint, or current
ON/OFF command.
Upon initialization, setpoint element is preset with zero; the ON/OFF element, with
OFF.
The event messages are comprised in form of groups. The following priority applies:
Event Group Symbol
System message SY
Sequence monitoring SC
Electrical system WE
Mechanical system WM
Material flow MF
Interlocking IL
Controllers CO
Check-and-correct system CH
Calibration CA
Maximum HI
Minimum LO
NOTE: In the following list, the parameters appertaining to the event message
displayed are stated in brackets.
8 Appendix
This chapter details special functions.
o DI = Digital input
o DO = Digital output
o AO = Analog output
o AI = Analog input
"Select Setpoint" and "Start/Stop" sources can be started from various operating
sources. Source is preselected by parameter.
Using the "Keyboard Mode" dialog function, you can change from preselected source
to keyboard, and vice versa.
Parameter Function Range
P03.02 Start source Keyboard/serial/contact
P03.03 Setpoint source Keyboard/serial
analog
P03.08 Setpoint with percental evaluation - -, OP, AI, DI4
Setpoint Displays:
Value Description
P Effective setpoint
Pe External setpoint (if selected with P03.03)
Pr Percental evaluation (if selected with P03.08)
Point in time:
1. As long as contact is open (no release signal), no start command is active.
3. Feeder starts with L-H edge of the START input or after START command
from another source.
7. During counter tracking time (P05.03), feed rate acquisition and totalization
are still active.
Alarm:
If feeder is cut off due to Alarm, prefeeder immediately stops.
If the time set by Parameter P05.02 has elapsed, measurement is
complete.
Measurement and Displays:
The measured load is always acquired and displayed.
Feed rate is acquired only in turned-on state and
during counter tracking time (P05.02). All phases of
active feed rate acquisition are reported by ON
message.
Overview
The central control unit is designed as two-stage cascade controller for control of feed
rate and speed. It consists of two PI controllers of the types.
Controller Parameters
The scheme below shows the correlation between controller parameters and control
magnitude.
Changing KP Changing TN
Vh206414_gb.cdr
Stand-By
If setpoint falls below the limit value set by Parameter P 06.03 "Standby Limit Value",
output sets drive to OFF. Controller control magnitude is set to its lower value in
accordance with Parameter P 10.08 "Position at Stop".
Controllers do not operate; the feed rate controller integral component is cleared, or
remains stored, as a function of Parameter P 10.09 "Store".
Speed controller integral component is cleared.
Measurement remains active.
If setpoint exceeds the limit set by Parameter P 06.03 "Standby Limit Value", system
immediately returns to normal mode.
Deviation
Deviation is displayed and monitored in gravimetric mode only.
Display is filtered using P 07.08 "Deviation"; monitoring is not filtered at all.
If the time of control difference Xd set by Parameter P 06.10 "Time Deviation" exceeds
the value of Parameter P 06.11 "Threshold Val. Dev.", event message HI-05 "Event
Deviation" is output. If controller difference exceeds threshold during the set time,
monitoring restarts.
NOTE: The most important batch settings are effected in Parameter Block 16 "Batch
Mode".
Batching Sequence:
(Fig. Details: Batching)
Point 0 : Start batch using scale START command.
Point 3 : Feed rate setpoint approaches zero and "Dribble Feed" and
"Full Feed" signals change edges. Determine point using Parameter P
16.15 "Adaptation Time". The effective setpoint is reduced in form of a
ramp or in steps as a function of Parameter P16.03 "Adaptation
Mode".
Condition for cut-off function (a):
• You can start new batch only when afterflow time has
elapsed.
Adaption
After every complete batch, system computes a correction amount based on missing
amount and stores value in Parameter "Correction Amount". Steps 3 and 4
automatically shift during next batching operation .
K(new) = K(old) + adap * Error
K(new) = New correction amount
adap. = Adaption factor
Errors exceeding the batch tolerance set by P 16.20 are limited to the set tolerance
value.
Errors smaller than smallest display digit are not corrected.
Alarm
Aborts batch. After remedy of cause and acknowledgement of message, batching can
be resumed.
Power OFF
Batch aborts, batching mode remains selected. All counter readings and batch values
are stored. Next start command starts new batch
Stand-By Mode
During deceleration time, feeder can go to stand-by mode. Relevant message is
suppressed.
Limit Values
Event messages Pmin and nmin are suppressed during deceleration time. This does
not apply to digital outputs.
Feature
Explanations:
All signal levels can be inverted by parameter setting. The drawing shows the default
values.
• E = Event message
• DI = Digital input
• DO = Digital output
Note:
With signals DI E1 - DI E2 and DI M1 - DI M5, you can also select LS (Logical Signal)
for source. This enables digital outputs to be used as well.
Note:
The time gate output cycle always consists of delay time plus pulse time.
Input is not reevaluated before this cycle has elapsed.
Use:
(i) Short signals --> extend for fixed time
(ii) Long signals --> generate cycle (pulse/pause)
iii) Doubling a digital output
The delay time has to be set to 0 sec. and the pulse time has to be set to 0.3 sec.
Example:
Simple fill control using single contact (e.g. MAX).
If MAX contact is open, filling interrupts for a defined time. When this time has
elapsed, MAX contact is reevaluated, and cycle restarts.
Parameter "Active in OFF" lets you determine whether fill control operates in ON state
only or also in OFF state.
• via the "mere" pulse output (open collector) only at VEA1 (-X6: 4, 5)
frequency <10Hz for electronic totalizing counter,
• via a relay output at VSEs or VEA; the minimum pulse length being 1sec, or
• via output D07 available on VSE1 when a VEA 20101 is used. DO7 is an
open collector output which can be used both as a quick pulse output and
as a "binary output", the maximum output frequency being 10Hz when used
as a quick pulse output.
The relevant parameters are:
• P02.19 Pulse output ("--" for pulse output at VEA1 or any digital output "DO")
Installation 50
Interlocking P22.01.P22.19 172
Interlocking P22.20...P22.27 174
LED 14
Linearization 12
Load Default Parameters 41
Material Discharge During Filling 10
Measuring Principle 5
Message Field 16
On Manual 1
Operating Functions 21
Operating Modes 5
Overview 4
Parameter Group 01 - Hardware Modules 75
Parameter Group 02 - Scale Definitions 77
Parameter Group 03 - Control Sources 83
Parameter Group 04 - Rated Data of Feeder 85
Parameter Group 05 - Scale Controlling 86
Parameter Group 06 - Scale Monitoring 92
Parameter Group 07 - Display Filters 97
Parameter Group 08 - Limit Values 98
Parameter Group 09 - Calibration Data 100
Parameter Group 10 - Controller 101
Parameter Group 11 - Linearization 107
Parameter Group 12 - Fuzzy DAE 109
Parameter Group 13 - Analog Outputs 111
Parameter Group 14 - Digital Inputs 113
Parameter Group 15 - Digital Outputs 118
Parameter Group 16 - Batch Mode 121
Parameter Group 17 - Process Control 124
Parameter Group 18 - Printer 126
Parameter Group 19 - Comm. EasyServe 127
Parameter Group 20 - Comm. Fieldbus 129
Parameter Group 21 - PLS Outputs 137
Parameter Group 22 - Interlocking 138
Parameter Group 26 - Bin Weigher 142
Parameter Group 27 - Safety Functions 147
Parameter Group 28 - Dead Time 150
Parameter Group 50 - Feed Index 2 152
Parameter groups 51-98- Feed index 3-50 155
Parameter List 65
Parameters 62
Performing Recalibration 61
Print Batch 45
Print FMZ (Totalizing Counter Readings) 27
Print Parameter Shortlist 43
Print Parameters 41
Programming Functions 39
Pulse output for delivery counters 178
Read Parameters 39
Relative Setpoint 20
Reset Totalizing Counters 20
Safety Instructions 2
Service Values 23
Setpoint and Start Sources 162
Setpoint Input 19
Setting DAE for normal requirements: 58
Setting DAE for special requirements: 58
Some Definitions 5
Speed Controller (external) 53
START / STOP Keyboard Mode 26
Start DISOCONT 13
START/STOP Scale 19
Starting Check 59
Status Field 15
Status Report 43
Testing Control Functions 50
Trend 25
Volumetric / Volumetric Synchronous / Gravimetric Modes 26
What is DISOCONT? 4