ø22 TW Series Selection Guide
Function Pushbutton
Flush Extended Extended w/Full Shroud ø29mm Mushroom ø40mm Mushroom
Category
Momentary/Maintained
Shape
Function Pushbutton
ø40mm Mushroom
ø29mm Mushroom ø40mm Mushroom ø40mm Mushroom ø29mm Mushroom
Category w/Full Shroud
Momentary Pushlock Turn Reset Pushlock Turn Reset Push Turn Lock Pushlock Key Reset
Shape
Function Pushbutton
ø40mm Mushroom ø40mm Mushroom Square Flush Square Extended
Category
Pushlock Key Reset Push Pull Momentary/Maintained
Shape
ABQW1 ABQW2
Model AXW4 AYW4
AOQW1 AOQW2
Page 9 9 9 9
Shape
APW1
Model APW2 APQW1B
APW1B
Page 10 10 10
2 (14/05/22)
TW Series Selection Guide ø22
Function Illuminated Pushbutton (LED/Incandescent)
Extended Extended w/Full Shroud Square Extended ø29mm Mushroom ø40mm Mushroom
Category
(Non-marking/Marking) (Non-marking/Marking) (Marking) Pushlock Turn Reset Pushlock Turn Reset
Shape
Shape
Illuminated Selector
Function Selector Switch Switch
(LED/Incandescent)
Category Knob Lever Key Knob
Shape
(14/05/22) 3
TW
ø22 Series Switches & Pilot Lights
General-purpose switches & pilot lights for various applications
Heavy-duty type for high-level protection against
harsh environment
• Highly reliable HW contact blocks are used.
• Degree of protection: IP65 (IEC 60529)
• UL and CSA approved, EN compliant
Applicable Standards Mark File No. or Organization
UL Listing
UL508
File No. E68961
TÜV Rheinland
EN60947-5-1
EU Low Voltage Directive
CCC
GB14048.5 No. 2003010305027380
(pilot light: No. 2007010304226713)
Contact Ratings
Rated Insulation Voltage 600V
Rated Continuous Current 10A
Contact Block
Contact Ratings by Utilization Category AC-15 (A600)
IEC 60947-5-1 DC-13 (P600)
Characteristics
Contact Ratings by Utilization Category
Operational Voltage 24V 48V 50V 110V 220V 440V
AC AC-12 Control of resistive loads and solid state loads 10A — 10A 10A 6A 2A
Operational 50/60 Hz AC-15 Control of electromagnetic loads (> 72 VA) 10A — 7A 5A 3A 1A
Current DC-12 Control of resistive loads and solid state loads 8A 4A — 2.2A 1.1A —
DC
DC-13 Control of electromagnets 4A 2A — 1.1A 0.6A —
Minimum applicable load: 3V AC/DC, 5 mA (applicable range may vary with operating conditions and load types)
For the switches & pilot Lights listed below, the rated current (load switching current) is reduced to a half of the rated operational current of
the contact block. The rated insulation voltage (600V) and the rated thermal current (10A) remain unchanged.
• Selector switches and illuminated selector switches with contact code 2S, 3S, 4S, 2R, or 4R.
Push rod
Snap-fit latch
Color-coded for
A maximum of four contact blocks in two
different contacts
layers can mount on the operator.
4 (14/05/22)
TW Series Switches & Pilot Lights ø22
LED Lamp Ratings (LSTD)
Part No. LSTD-6 LSTD-1 LSTD-2
Lamp Base BA9S/13
Rated Voltage 6V AC/DC 12V AC/DC 24V AC/DC
Voltage Range 6V AC/DC ±10% 12V AC/DC ±10% 24V AC/DC ±10%
AC 8 mA 11 mA 11 mA
Current Draw
DC A, R, W: 7 mA, G, PW, S: 5.5 mA 10 mA 10 mA
A (amber), G (green), PW (pure white), R (red), S (blue), W (white)
Color Code Use a pure white LED lamp for yellow illumination
Lamp Base Color Same as illumination color
Voltage Marking Die stamped on the base
Approx. 50,000 hours (until the brightness reduces to 50% of the initial value when lit at complete direct
Life (reference value)
current of the rated voltage under 25ºC environment.)
X1 LED Chip
Protection Diode
Internal Circuit
Zener Diode
X2 Resistor
Specifications
Operating Temperature –25 to +50°C (no freezing)
Storage Temperature –40 to +80°C
Operating Humidity 45 to 85% RH (no condensation)
Contact Resistance 50 mΩ maximum (initial value)
Insulation Resistance 100 MΩ minimum (500V DC megger)
Between live and dead metal parts: 2,500V AC, 1 minute
Dielectric Strength
(Full voltage illuminated units: 2,000V AC, 1 minute)
Damage Limits: 30 Hz, amplitude 1.5 mm
Vibration Resistance
Operating extremes: 5 to 55 Hz, amplitude 0.5 mm
Damage limits: 1,000 m/s2
Shock Resistance
Operating extremes: 100 m/s2
Pushbuttons, Illuminated pushbuttons
Momentary: 5,000,000
Mechanical Life (minimum operations) Others: 500,000
Selector switches: 500,000
Illuminated selector switches: 500,000
Pushbuttons: 500,000 (switching frequency 1,800 operations/h, duty ratio 40%)
Electrical Life (minimum operations) Illuminated pushbuttons: 500,000 (switching frequency 1,800 operations/h, duty ratio 40%)
Selector switches: 500,000 (switching frequency 1,200 operations/h, duty ratio 40%)
68g (ABW122)
33g (APW122D)
89g (ALW22222D)
Weight (approx.) 68g (ASW222)
107g (ASW2K22)
90g (ASLW22222D)
95g (APW126D)
30 (Note 2)
50
Degree of Protection
Part No. Unit NEMA ICS 6-110 IEC 60529
Pushbuttons, pilot lights, illuminated pushbuttons, and selector switches Type 1, 2, 3, 3R, (3S), 4, 5, 12,13 IP65
A∗∗∗∗ Illuminated selector switches, key pushbuttons, key reset pushbuttons, and
Type 1, 2, 3R, 5, 12, 13 IP54
key selector switches
Note: (3S) of NEMA ICS 6-110 applies to the pilot lights with round lens.
(14/05/22) 5
ø22 TW Series Ordering Information
Ordering Information
• Specify an operator or lens color code in the Part No. • When a terminal cover is required, order an applicable
• All standard units are UL, CSA, EN, and TÜV approved. terminal cover referring to page 29.
Part No. development charts shown below can be used to specify switches/pilot lights other than those listed on the following
pages. Gold-plated silver contacts are also available.
6 (14/05/22)
TW Series Pushbuttons ø22
2NC ABW102
2NO-2NC ABW122
ø24
ø29
37
1NO AOW110
1NC AOW101 48.5 (1-2 blocks) 13
68.5 (3-4 blocks) 30
1NO-1NC AOW111
Maintained
2NO AOW120
2NC AOW102
2NO-2NC AOW122
Extended 1NO ABW210
ABW2 1NC ABW201
AOW2
1NO-1NC ABW211
Momentary M3.5 Terminal
2NO ABW220 Screws Panel Thickness 1 to 6
2NC ABW202
2NO-2NC ABW222
ø24
ø29
37
1NO AOW210
48.5 (1-2 blocks) 13
1NC AOW201
Specify a button 68.5 (3-4 blocks) 19 30
1NO-1NC AOW211 color code in
Maintained
2NO AOW220 place of in the
2NC AOW202 Part No.
2NO-2NC AOW222
B: black
Extended with Full Shroud 1NO ABFW210 G: green
ABFW2 1NC ABFW201 R: red
AOFW2 S: blue
1NO-1NC ABFW211 M3.5 Terminal
Momentary W: white Screws
2NO ABFW220 Panel Thickness 1 to 6
Y: yellow
2NC ABFW202
2NO-2NC ABFW222
ø24
ø29
37
1NO AOFW210
48.5 (1-2 blocks) 19.5
1NC AOFW201
68.5 (3-4 blocks) 30
1NO-1NC AOFW211
Maintained
2NO AOFW220
2NC AOFW202
2NO-2NC AOFW222
ø29mm Mushroom 1NO ABW310
ABW3 1NC ABW301
AOW3
1NO-1NC ABW311
Momentary M3.5 Terminal
2NO ABW320 Screws Panel Thickness 1 to 6
2NC ABW302
2NO-2NC ABW322
ø29
37
1NO AOW310
1NC AOW301 48.5 (1-2 block) 13
22.5
1NO-1NC AOW311 68.5 (3-4 blocks) 30
Maintained
2NO AOW320
2NC AOW302
2NO-2NC AOW322
• Round bezel and shroud (metal): Mat aluminum color
• Pushbuttons with one or three contact blocks contain a dummy block.
• Other contact arrangements and gold-plated silver contacts are also available. See page 6.
(14/05/22) 7
ø22 TW Series Pushbuttons
Mushroom / Pushlock Turn Reset / Push Turn Lock / Pushlock Key Reset
2NC ABW402
2NO-2NC ABW422
ø40
37
1NO AOW410
Specify a button 48.5 (1-2 blocks) 13
1NC AOW401 color code in 68.5 (3-4 blocks) 22.5 30
1NO-1NC AOW411 place of in the
Maintained Part No.
2NO AOW420
2NC AOW402
B: black
2NO-2NC AOW422 G: green
ø40mm Mushroom ABGW410 R: red
1NO
w/Full Shroud S: blue
M3.5 Terminal
ABGW4 W: white Panel Thickness 1 to 6
1NC ABGW401 Screw
Y: yellow
1NO-1NC ABGW411
ø46
37
Momentary
2NO ABGW420
48.5 (1-2 blocks)
68.5 (3-4 blocks) 23 30
2NC ABGW402
2NO-2NC ABGW422
ø29mm Pushlock Turn Reset 1NO AVW310 M3.5 Terminal
AVW3 (Note) Screws
Panel Thickness
1 to 6 Reset Angle 75
1NC AVW301
1NO-1NC AVW311
ø29
37
2NO AVW320
48.5 (1-2 blocks) 13
2NC AVW302 30
68.5 (3-4 blocks) 22.5
2NO-2NC AVW322 R: red
ø40mm Pushlock Turn Reset 1NO AVW410 Y: yellow
M3.5 Terminal Panel Thickness
AVW4 (Note) Screws 1 to 6 Reset Angle 75
1NC AVW401
1NO-1NC AVW411
ø40
37
2NO AVW420
48.5 (1-2 blocks) 13
2NC AVW402
68.5 (3-4 blocks) 22.5 30
2NO-2NC AVW422
ø40mm Push Turn Lock 1NO AJW410
M3.5 Terminal Panel Thickness
AJW4 Screws 1 to 6 Reset Angle 75
1NC AJW401
B: black LO
1NO-1NC AJW411 G: green
H
S
CK
PU
ø40
37
1NO-1NC AXW311R
ø29
Red only
37
2NO AXW320R
13
2NC AXW302R 48.5 (1-2 blocks) 25
68.5 (3-4 blocks) 47 30
2NO-2NC AXW322R
• Round bezel (metal): Mat aluminum color
• Pushbuttons with one or three contact blocks contain a dummy block.
• Other contact arrangements and gold-plated silver contacts are also available. See page 6.
Note: AVW3, AVW4, and AXW3 pushbuttons cannot be used as emergency stop switches. When emergency stop switches are required,
use XW or HW series pushbuttons (ISO 13850 and IEC 60947-5-5 compliant).
8 (14/05/22)
TW Series Pushbuttons ø22
1NO-1NC AXW411R
Red only
ø40
37
2NO AXW420R
13
48.5 (1-2 blocks) 25
2NC AXW402R
68.5 (3-4 blocks) 47 30
2NO-2NC AXW422R
ø40mm Mushroom Push-Pull 1NO AYW410 M3.5 Terminal Panel Thickness
AYW4 Screws 1 to 6
1NC AYW401
ø40
37
1NO-1NC AYW411
13
2NO AYW420 48.5 (1-2 blocks) 25
68.5 (3-4 blocks) 30.5 30
2NC AYW402
Square Flush 1NO ABQW110
ABQW1 1NC ABQW101
AOQW1
1NO-1NC ABQW111
Momentary M3.5 Terminal
2NO ABQW120 Screws Panel Thickness
Specify a button 1 to 6
2NC ABQW102
color code in
2NO-2NC ABQW122 place of in the
30
25
37
1NO AOQW110 Part No.
1NC AOQW101 48.5 (1-2 blocks) 13
AOQW111 B: black
1NO-1NC 30
Maintained G: green 68.5 (3-4 blocks)
2NO AOQW120 R: red
2NC AOQW102 S: blue
2NO-2NC AOQW122 W: white
Square Extended 1NO ABQW210 Y: yellow
ABQW2 1NC ABQW201
AOQW2
1NO-1NC ABQW211
Momentary M3.5 Terminal
2NO ABQW220 Screws
Panel Thickness
1 to 6
2NC ABQW202
2NO-2NC ABQW222
30
25
37
1NO AOQW210
1NC AOQW201 48.5 (1-2 blocks) 13
(14/05/22) 9
ø22 TW Series Pilot Lights
Dome
APW2 A: amber, G: green, R: red, S: blue, W: white,
Without Lamp APW299 Y: yellow
Designation Code
Specify an designation code in place of in the Part No.
Operating Voltage Code Input Type
LED Incandescent
66: 6V AC/DC 66: 6V AC/DC
11: 12V AC/DC 88: 12V AC/DC Full Voltage
22: 24V AC/DC 33: 24V AC/DC
16: 100/110V AC
126: 115/120V AC
26: 200/220V AC
246: 230/240V AC Transformer
386: 380V AC
46: 400/440V AC
486: 480V AC
16D: 110V DC — DC-DC Converter *
• Use a pure white LED lamp for yellow illumination.
• The white (W) lens of APW1B and APQW1B consists of a clear lens and a white marking plate.
• Round bezel (metal): Mat aluminum color Square bezel (plastic): Black
∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).
10 (14/05/22)
TW Series Pilot Lights ø22
Dimensions
Round Flush APW1 Round Flush APW1
Full Voltage Transformer, DC-DC Converter
Panel Thickness Panel Thickness
1 to 6 M3.5 Terminal Screw 1 to 6
ø24
ø29
ø24
ø29
37
37
28.5 13 30 28.5 13 30
17 66.5 17
37
ø24
ø29
37
28.5 13 30 28.5 13 30
17 66.5 17
Marking plate: ø15.5 mm Marking plate: ø15.5 mm
ø23.6
ø29
ø29
37
37
28.5 13 30 28.5 13 30
25 66.5 25
37
37
28.5 13 30 28.5 13 30
16 66.5 16
Marking plate: 22 mm Marking plate: 22 mm
TOP TOP
M3.5
M3.5
X1
X1
X2
X2
(14/05/22) 11
ø22 TW Series Illuminated Pushbuttons
Designation Code
Specify a designation code in place of or in the Part No.
Lens/Illumination Color Code Operating Voltage Code
Input Type
Without Lamp LED Incandescent LED Incandescent
66: 6V AC/DC 66: 6V AC/DC
11: 12V AC/DC 88: 12V AC/DC Full Voltage
22: 24V AC/DC 33: 24V AC/DC
A: amber A: amber A: amber
G: green G: green G: green 16: 100/110V AC
R: red PW: pure white R: red 126: 115/120V AC
S: blue R: red S: blue 26: 200/220V AC
W: white S: blue W: white
246: 230/240V AC Transformer
Y: yellow W: white
Y: yellow 386: 380V AC
46: 400/440V AC
486: 480V AC
16D: 110V DC — DC-DC Converter *
• Use a pure white LED lamp for yellow illumination.
*DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).
12 (14/05/22)
TW Series Illuminated Pushbuttons ø22
Designation Code
Specify a designation code in place of or in the Part No.
Lens/Illumination Color Code Operating Voltage Code
Input Type
Without Lamp LED Incandescent LED Incandescent
66: 6V AC/DC 66: 6V AC/DC
11: 12V AC/DC 88: 12V AC/DC Full Voltage
A: amber A: amber A: amber 22: 24V AC/DC 33: 24V AC/DC
G: green G: green G: green 16: 100/110V AC
R: red PW: pure white R: red 126: 115/120V AC
S: blue R: red S: blue
26: 200/220V AC
W: white S: blue W: white
Y: yellow W: white 246: 230/240V AC Transformer
Y: yellow 386: 380V AC
46: 400/440V AC
486: 480V AC
16D: 110V DC — DC-DC Converter *
• Use a pure white LED lamp for yellow illumination.
*DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).
(14/05/22) 13
ø22 TW Series Illuminated Pushbuttons
Designation Code
Specify a designation code in place of or in the Part No.
Lens/Illumination Color Code Operating Voltage Code
Input Type
Without Lamp LED Incandescent LED Incandescent
66: 6V AC/DC 66: 6V AC/DC
11: 12V AC/DC 88: 12V AC/DC Full Voltage
22: 24V AC/DC 33: 24V AC/DC
A: amber A: amber A: amber
G: green G: green G: green 16: 100/110V AC
R: red PW: pure white R: red 126: 115/120V AC
S: blue R: red S: blue 26: 200/220V AC
W: white S: blue W: white
Y: yellow W: white 246: 230/240V AC Transformer
Y: yellow 386: 380V AC
46: 400/440V AC
486: 480V AC
16D: 110V DC — DC-DC Converter *
• Use a pure white LED lamp for yellow illumination.
∗DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).
14 (14/05/22)
TW Series Illuminated Pushbuttons ø22
Designation Code
Specify a designation code in place of or in the Part No.
Lens/Illumination Color Code Operating Voltage Code
Input Type
Without Lamp LED Incandescent LED Incandescent
66: 6V AC/DC 66: 6V AC/DC
11: 12V AC/DC 88: 12V AC/DC Full Voltage
22: 24V AC/DC 33: 24V AC/DC
A: amber A: amber A: amber
G: green G: green G: green 16: 100/110V AC
R: red PW: pure white R: red 126: 115/120V AC
S: blue R: red S: blue 26: 200/220V AC
W: white S: blue W: white
Y: yellow W: white 246: 230/240V AC Transformer
Y: yellow 386: 380V AC
46: 400/440V AC
486: 480V AC
16D: 110V DC — DC-DC Converter ∗
• Use a pure white LED lamp for yellow illumination.
∗DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).
(14/05/22) 15
ø22 TW Series Illuminated Pushbuttons
Designation Code
Specify a designation code in place of or in the Part No.
Lens/Illumination Color Code Operating Voltage Code
Input Type
Without Lamp LED Incandescent LED Incandescent
66: 6V AC/DC 66: 6V AC/DC
11: 12V AC/DC 88: 12V AC/DC Full Voltage
22: 24V AC/DC 33: 24V AC/DC
A: amber A: amber A: amber
G: green G: green G: green 16: 100/110V AC
R: red PW: pure white R: red 126: 115/120V AC
S: blue R: red S: blue 26: 200/220V AC
W: white S: blue W: white
Y: yellow W: white 246: 230/240V AC Transformer
Y: yellow 386: 380V AC
46: 400/440V AC
486: 480V AC
16D: 110V DC — DC-DC Converter *
• Use a pure white LED lamp for yellow illumination.
*DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).
16 (14/05/22)
TW Series Illuminated Pushbuttons ø22
Designation Code
Specify a designation code in place of or in the Part No.
Lens/Illumination Color Code Operating Voltage Code
Input Type
Without Lamp LED Incandescent LED Incandescent
66: 6V AC/DC 66: 6V AC/DC
11: 12V AC/DC 88: 12V AC/DC Full Voltage
A: amber A: amber A: amber
22: 24V AC/DC 33: 24V AC/DC
G: green G: green G: green
R: red PW: pure white R: red 16: 100/110V AC
S: blue R: red S: blue 126: 115/120V AC
W: white S: blue W: white 26: 200/220V AC
Y: yellow W: white
Y: yellow 246: 230/240V AC Transformer
386: 380V AC
46: 400/440V AC
486: 480V AC
• Use a pure white LED lamp for yellow illumination.
Note: TW series pushlock turn reset illuminated pushbuttons cannot be used as emergency stop switches under international safety
standards ISO13850 and IEC60947-5. For use as emergency stop switches, use XW or HW series.
(14/05/22) 17
ø22 TW Series Illuminated Pushbuttons
1NO-1NC AYLW411
Incandescent Transformer
2NO AYLW420
ø40 Mushroom Push Pull (Marking) 1NO AYLW4B9911
AYLW4B
(2-position Without Lamp Full Voltage 1NC AYLW4B9920
maintained)
1NO-1NC AYLW4B9922
1NO-1NC AYLW4B11
Incandescent Transformer
2NO AYLW4B20
Designation Code
Specify a designation code in place of or in the Part No.
Lens/Illumination Color Code Operating Voltage Code
Input Type
Without Lamp LED Incandescent LED Incandescent
66: 6V AC/DC 66: 6V AC/DC
11: 12V AC/DC 88: 12V AC/DC Full Voltage
A: amber A: amber A: amber 22: 24V AC/DC 33: 24V AC/DC
G: green G: green G: green
R: red PW: pure white R: red 16: 100/110V AC
S: blue R: red S: blue 126: 115/120V AC
W: white S: blue W: white 26: 200/220V AC
Y: yellow W: white 246: 230/240V AC Transformer
Y: yellow 386: 380V AC
46: 400/440V AC
486: 480V AC
• Use a pure white LED lamp for yellow illumination.
Note: TW series pushlock turn reset illuminated pushbuttons cannot be used as emergency stop switches under international safety
standards ISO13850 and IEC60947-5. For use as emergency stop switches, use XW or HW series.
Contact Statuses of Push-Pull Switch
ø40mm Mushroom Push-Pull Switch
Contact
Push Pull
1NO
1NC
1NO-1NC
2NO
2NC
18 (14/05/22)
TW Series Illuminated Pushbuttons ø22
Dimensions (Operator)
Round Extended (non-marking/marking) Round Extended with Full Shroud Square Extended (marking)
ALW2 / ALW2B / AOLW2 / AOLW2B (non-marking/marking) ALQW2B / AOLQW2B
ALFW2 / ALFW2B / AOLFW2 / AOLFW2B
Panel Thickness Panel Thickness
1 to 6 1 to 6
Panel Thickness
1 to 6
25
30
ø29
ø24
37
37
ø29
ø24
37
13 13
30 30
19 20
20 30
Marking plate: ø15.5mm Marking plate: 21mm
Marking plate: ø15.5mm
ø29 Mushroom (non-marking/marking) ø29 Mushroom Pushlock Turn Reset ø40 Mushroom Pushlock Turn Reset
ALW3 / ALW3B / AOLW3 / AOLW3B (non-marking/marking) (non-marking/marking)
Panel Thickness
AVLW3 / AVLW3B AVLW4 / AVLW4B
1 to 6
Panel Thickness Panel Thickness
1 to 6 Reset Angle: 75° Reset Angle 75°
1 to 6
ø29
37
ø29
37
ø40
37
13
30 13 13
22.5 30
22.5
Marking plate: ø13.9mm 22.5 30
Marking plate: ø13.9mm Marking plate: ø13.9mm
37
13
25 30
30.5
Marking plate: ø13.9mm
All dimensions in mm.
X1 X1
X1
X2
X2 X2
(14/05/22) 19
ø22 TW Series Illuminated Pushbuttons
Dimensions
Full Voltage Transformer
DC-DC Converter
X1
X1
X2
X2
X1 X2
X2
4 contact 106.5
2 contact 63.5
blocks
blocks
When using TW-DA1B full-voltage adapter
3 contact 68.5
blocks
When using HW-DA1B full-voltage adapter
Panel Thickness
M3.5 Terminal Screws 1 to 6
X1
X2
4 contact 83.5
blocks
When using TW-DA1B full-voltage adapter
Note: For push-pull units a maximum of two contact blocks can be used. All dimensions in mm.
20 (14/05/22)
TW Series Selector Switches ø22
ø24
ø29
37
48.5 (2 blocks) 13
68.5 (4 blocks) 25 30
Contact Arrangement Chart
Maintained Spring Return Spring Return
Contact Block Operator Position from Right from Left
Contact
—
Code Mounting
L R L R L R
Position
Contact L R
10 1 NO
ASW210 ASW2110 ASW2210 ∗
(1NO) 2 Dummy
11 1 NO
ASW211 ASW2111 ASW2211 ∗
(1NO-1NC) 2 NC
90° 2-position
20 1 NO
ASW220 ASW2120 ASW2220 ∗ —
(2NO) 2 NO
1 NO
22 2 NC
ASW222 ASW2122 ASW2222 ∗
(2NO-2NC) 3 NO
4 NC
Maintained Spring Return Spring Return Spring Return
Contact Block Operator Position from Right from Left Two-way
Contact C C C C
Code Mounting
L R L R L R L R
Position
Contact L C R
20 1 NO
ASW320 ASW3120 ASW3220 ASW3320
(2NO) 2 NO
02 1 NC
ASW302 ASW3102 ASW3202 ASW3302
(2NC) 2 NC
1 NO
22 2 NO
ASW322 ASW3122 ASW3222 ASW3322
(2NO-2NC) 3 NC
4 NC
1 NO
40 2 NO
ASW340 ASW3140 ASW3240 ASW3340
(4NO) 3 NO
4 NO
1 NC
04 2 NC
ASW304 ASW3104 ASW3204 ASW3304
45° 3-position
(4NC) 3 NC
4 NC
1 NO
2 NO
3S ASW33S-243 — — —
3 NC
4 Dummy
Position
Contact 1 2 3 4 5 4
Left Center Right
1 NC
2 NC
4S ASW44S-407 —
3 NC L C R Operator
4 NO Position
30° 5-position / 45° 4-position
1 NO
1 NO
2 NC 2 NO
4S ASW44S-411 —
3 NC 3 NC
4 NO 4 NC
1 NO 4 TOP
2 NC 2
3S ASW43S-461 —
3 NC • For more contact
4 Dummy arrangement chart,
1 NO see pages 26 to 28.
2 NC 3
4S — ASW54S-501 1
3 NC
4 NO
• On the 2-position selector switches marked with ∗ above, the contact operation is reversed as follows.
• On the contact arrangement marked with in the table above, the rated current (load switching current) is reduced to a half of the rated
current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged.
• Selector switches with one or three contact blocks contain a dummy block.
• Knob operator: White indicator on black knob
(14/05/22) 21
ø22 TW Series Selector Switches
ø29
37
ø25
48.5 (2 blocks) 13
68.5 (4 blocks) 25 30
Contact Arrangement Chart
Maintained Spring Return Spring Return
Contact Block Operator Position from Right from Left
Contact L R
—
Code Mounting
L R L R
Position
Contact L R
10 1 NO
ASW2L10 ASW21L10 ASW22L10 ∗
(1NO) 2 Dummy
11 1 NO
ASW2L11 ASW21L11 ASW22L11 ∗
(1NO-1NC) 2 NC
90° 2-position
20 1 NO
ASW2L20 ASW21L20 ASW22L20 ∗ —
(2NO) 2 NO
1 NO
22 2 NC
ASW2L22 ASW21L22 ASW22L22 ∗
(2NO-2NC) 3 NO
4 NC
Maintained Spring Return Spring Return Spring Return
Contact Block Operator Position from Right from Left Two-way
Contact C
C C C
L R
Code Mounting
L R L R L R
Position
Contact L C R
20 1 NO
ASW3L20 ASW31L20 ASW32L20 ASW33L20
(2NO) 2 NO
02 1 NC
ASW3L02 ASW31L02 ASW32L02 ASW33L02
(2NC) 2 NC
1 NO
22 2 NO
ASW3L22 ASW31L22 ASW32L22 ASW33L22
(2NO-2NC) 3 NC
4 NC
1 NO
40 2 NO
ASW3L40 ASW31L40 ASW32L40 ASW33L40
(4NO) 3 NO
4 NO
1 NC
04 2 NC
ASW3L04 ASW31L04 ASW32L04 ASW33L04
45° 3-position
(4NC) 3 NC
4 NC
1 NO
2 NO
3S ASW3L3S-243 — — —
3 NC
4 Dummy
Maintained Maintained
Contact Block Operator Position Contact Block Mounting Position
Contact 2 3
Code
1 3
1
2 4
5
and Contact Arrangement Chart
Mounting
Position
Contact 1 2 3 4 5 4 Left Center Right
1 NC
2 NC
4S ASW4L4S-407 — L C R Operator
3 NC Position
4 NO 1 NO
30° 5-position / 45° 4-position
1 NO 2 NO
2 NC
3 NC
4S ASW4L4S-411 —
3 NC
4 NO 4 NC
4 TOP
1 NO 2
2 NC • For more contact
3S ASW4L3S-461 — arrangement chart,
3 NC
4 Dummy see pages 26 to 28.
1 NO 3
2 NC 1
4S — ASW5L4S-501
3 NC
4 NO
• On the 2-position selector switches marked with ∗ above, the contact operation is reversed as follows.
• On the contact arrangement marked with in the table above, the rated current (load switching current) is reduced to a half of the rated
current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged.
• Selector switches with one or three contact blocks contain a dummy block.
• Lever operator: White indicator on black lever
22 (14/05/22)
TW Series Selector Switches ø22
ø29
ø24
37
13
48.5 (2 blocks) 19
30
Contact Arrangement Chart 68.5 (4 blocks) 41
Position
Contact L R
10 1 NO
ASW2K10 ASW21K10 ASW22K10 ∗
(1NO) 2 Dummy
11 1 NO
ASW2K11 ASW21K11 ASW22K11 ∗
(1NO-1NC) 2 NC
90° 2-position
20 1 NO
ASW2K20 ASW21K20 ASW22K20 ∗ —
(2NO) 2 NO
1 NO
22 2 NC
ASW2K22 ASW21K22 ASW22K22 ∗
(2NO-2NC) 3 NO
4 NC
Maintained Spring Return Spring Return Spring Return
Contact Block Operator Position from CRight fromC Left Two-way
Contact C C
Code Mounting
L R L R L R L R
Position
Contact L C R
20 1 NO
ASW3K20 ASW31K20 ASW32K20 ASW33K20
(2NO) 2 NO
02 1 NC
ASW3K02 ASW31K02 ASW32K02 ASW33K02
(2NC) 2 NC
1 NO
22 2 NO
ASW3K22 ASW31K22 ASW32K22 ASW33K22
(2NO-2NC) 3 NC
4 NC
1 NO
40 2 NO
ASW3K40 ASW31K40 ASW32K40 ASW33K40
(4NO) 3 NO
4 NO
1 NC
04 2 NC
ASW3K04 ASW31K04 ASW32K04 ASW33K04
45° 3-position
(4NC) 3 NC
4 NC
1 NO
2 NO
3S ASW3K3S-243 — — —
3 NC
4 Dummy
• On the spring-returned types, the key can be released only from the maintained position. On the maintained types, the key can be re-
leased from every position. Key retained positions are also available. See page 6.
• On the 2-position selector switches marked with ∗ above, the contact operation is reversed as follows.
• On the contact arrangement marked with in the table above, the rated current (load switching current) is reduced to a half of the rated
current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged.
• Key selector switches with one or three contact blocks contain a dummy block.
• Cylinder cover: Black, Cylinder: Metal
L C R Operator
Position
1 NO
3 2 NO
1 3 NC
4 NC
(14/05/22) 23
ø22 TW Series Illuminated Selector Switches
ø24
ø29
37
13
A: 63.5 (2 blocks)
83.5 (4 blocks) 25 30
Position
Contact L R
11
2 NC LED ASLW211D ASLW2111D ASLW2211D
(1NO-1NC)
20
2 NO LED ASLW220D ASLW2120D ASLW2220D
(2NO)
1 NO
Without Lamp ASLW29922 ASLW219922 ASLW229922
2 NC
22 3 NO
LED ASLW222D ASLW2122D ASLW2222D
(2NO-2NC) 4 NC
Designation Code
Specify a designation code in place of or in the Part No.
Lens/Illumination Color Code Operating Voltage Code
Input Type
Without Lamp LED Incandescent LED Incandescent
66: 6V AC/DC 66: 6V AC/DC
11: 12V AC/DC 88: 12V AC/DC Full Voltage
A: amber A: amber A: amber 22: 24V AC/DC 33: 24V AC/DC
G: green G: green G: green
R: red PW: pure white R: red 16: 100/110V AC
S: blue R: red S: blue 136: 115/120V AC
W: white S: blue W: white 26: 200/220V AC
Y: yellow W: white 256: 230/240V AC Transformer
Y: yellow 386: 380V AC
46: 400/440V AC
486: 480V AC
4 Left Right
2 TOP
L R Operator
Position
1 NO
3 2 NC
1
3 NO
4 NC
24 (14/05/22)
TW Series Illuminated Selector Switches ø22
Position
Contact L C R
Designation Code
Specify a designation code in place of or in the Part No.
Lens/Illumination Color Code Operating Voltage Code
Input Type
Without Lamp LED Incandescent LED Incandescent
66: 6V AC/DC 66: 6V AC/DC
11: 12V AC/DC 88: 12V AC/DC Full Voltage
A: amber A: amber A: amber 22: 24V AC/DC 33: 24V AC/DC
G: green G: green G: green
R: red PW: pure white R: red 16: 100/110V AC
S: blue R: red S: blue 136: 115/120V AC
W: white S: blue W: white 26: 200/220V AC
Y: yellow W: white 256: 230/240V AC Transformer
Y: yellow 386: 380V AC
46: 400/440V AC
486: 480V AC
(14/05/22) 25
ø22 TW Series Selector Switch Contact Arrangement Charts
90° 2-position (Maintained / Spring Return)
Spring
Maintained Return Spring Return from Left
Positions from Right
L R L R L R
26 (14/05/22)
TW Series Selector Switch Contact Arrangement Charts ø22
(14/05/22) 27
ø22 TW Series Selector Switch Contact Arrangement Charts
45° 3-position (Maintained) 45° 4-position (Maintained)
Maintained Maintained
2
Positions L
C
R
Positions 1 3
2 NO 1 NC
3S 243
3 NC 2 NC
405
4 Dummy 3 NC
1 NO 4 NC
2 NC 1 NC
233
3 NC 2 NC
407
4 NO 3 NC
1 NO 4 NO
4S
2 NC 1 NO
234
3 NC 2 NC
409
4 NC 3 NC
1 NC 4 NC
2 NO 1 NO
4S 235
3 NC 2 NC
411
4 NO 3 NC
1 NO 4 NO
2 NO
237
3 NC
4 NO
1 NC
30° 5-position (Maintained)
2 NC Maintained
240
3 NC Positions 2
3
4
4 NO 1 5
28 (14/05/22)
TW Series Accessories and Replacement Parts ø22
Terminal Covers
Terminal
Cover
Switch/Pilot Light 39.8H × 14.1W 37.8H × 26W 39.8H × 8.7W 39.1H × 15.5W 40H × 14.8W 36H × 29.4W
• Pilot light
APW Full Voltage X +6mm
APQW
Transformer
X +3mm
DC-DC Converter
• Pushbutton 1 contact block
ABW
AOW CB Terminal Cover X
AVW
ABQW
ABFW
AJW 2 contact blocks
AOQW
CB X
AOFW
CB 2 pieces
AXW
ABGW
AYW +3.5mm
3 contact blocks
• Selector X
CB CB
switch CB 2 pieces
ASW
4 contact blocks
CB CB X
CB CB 2 pieces
(14/05/22) 29
ø22 TW Series Accessories and Replacement Parts
Nameplates
Package
Dimensions (mm) Legend Material Part No. Ordering No. Description
Quantity
NWA NWA-0 1
29 Blank NWA-0 Black
NWA-0PN10 10
OFF Aluminium
0.8 mm thick
20
black background
NWAQ-∗PN10 10
NWAS
45
NWAS-0 1
Aluminium
Blank NWAS-0 Black
0.8 mm thick
45
NWAS-0PN10 10
NWAL
29 NWAL-0 1
Aluminium
Blank NWAL-0 Black
0.8 mm thick
25
NWAL-0PN10 10
NWAQL
29 NWAQL-0 1
Aluminium
Blank NWAQL-0 Black
0.8 mm thick
25
NWAQL-0PN10 10
14.5
Legends
Code Legend
0 (blank)
1 ON
2 OFF
3 START
4 STOP
31 OFF-ON
35 HAND-AUTO
53 HAND-OFF-AUTO
30 (14/05/22)
TW Series Accessories and Replacement Parts ø22
Accessories
Package
Shape Material Part No. Ordering No. Dimensions
Quantity
Locking Ring Wrench • Used to tighten the round bezel when installing
the TW switch/pilot light onto a panel.
Rubber
ø46
ø31
ø34
OR-14 OR-14 1
(nitryl) 90 16
ø11.6
ø14
OR-55 OR-55 1
(nitryl)
59
23
(zinc-plated)
TW-KC1 TW-KC1 1
Rubber 130
(nitryl)
ø19
39
Nut Locking Wrench • Used to tighten the locking nuts inside of the
square bezel.This tool can be inserted into the
OR-14 locking ring wrench.
20
Metal
TW-KQ2 TW-KQ2 1
(nickel-plated)
22.5
25.7
80
Metal
OGL-31 OGL-31PN10 10
(zinc-plated)
10.2
ø25
3.5
Metallic Mounting Hole Plug • Used to plug unused ø22.2mm mounting holes.
• Tightening torque: 1.2 N·m
• Degree of protection: IP66 (without the 3.2mm
Diecast Metal recess in the mounting hole)
(locking ring: LW9Z-BM LW9Z-BM 1 ø25.8
3
polyamide)
Gasket
12
Locking Ring
Plastic Mounting Hole Plug • Used to plug the unused ø22.2mm mounting
holes.
Plastic • Tighten the locking ring to a torque of 2.0 N·m.
LW9Z-BP1 LW9Z-BP1 1 IP65
(polyamide) • Mounting panel thickness: 0.8 to 6 mm
(14/05/22) 31
ø22 TW Series Accessories and Replacement Parts
Accessories
Package
Shape Material Part No. Ordering No. Description
Quantity
Contact Rubber • Oiltight rubber boot used for pushbuttons and
Boot selector switches.
For 1 layer of • Temperature range: –5 to +60°C
contact blocks • Black
OCW-99 OCW-99 1
(2 contact
blocks) OCW-99
2.2
48
Rubber
(nitryl) 38 14 45.5
For 2 layers of
contact blocks
50
OCW-299 OCW-299 1 OCW-299
(4 contact
blocks)
38 14 65.5
ø32.6
(ABW1/AOW1)
outdoor use or where the
Rubber units are subject to oil
(EPDM) splash.
For extended
pushbuttons OC-32 OC-32 1 18 (OC-31)
(ABW2/AOW2) 22 (OC-32)
(nitryl)
ø32
ø31
ø26
ø31
ø32
For extended
pushbuttons OCW-11 OCW-11 1 18.5
Button
21
Button
installed installed
(ABW2/AOW2)
Flush Extended
Polyarylate
R6
93
rubber)
30
70
24 (inside)
0 4)
ø2
ø5 44.
2.
Waterproof Rubber
:ø
2
Metal
HS9Z-PC22 HS9Z-PC22 1
(copper)
Note: Specify a button color code or lens color code in place of or in the Ordering No.
32 (14/05/22)
TW Series Accessories and Replacement Parts ø22
Accessories
Package
Shape Material Part No. Ordering No. Remarks
Quantity
ø40mm Lens
ALW4L- ALW4L- 1 : G (green), R (red),
• Applicable S (blue)
unit:
Non-marking ALW3,
ALW4LD- ALW4LD- 1 AOLW3 : A (amber),
W (white)
Plastic
• Applicable : G (green), R (red),
ALW4BL- ALW4BL- 1 unit: S (blue), W (white)
ALW3B,
Marking AOLW3B
ALW4BLD- ALW4BLD- 1 • Marking plate : A (amber)
is included
Plastic Bezel ➊Flush AW-RP1B AW-RP1BPN05 5
➊ ➋ AW-FP1B AW-FP1B 1
➋Extended
➌Extended
(for illuminated AW-FP2B AW-FP2B 1
➌ ➍ pushbuttons)
➍Square round Plastic Black
(for round AW-H1B AW-H1B 1
pushbuttons)
➎ ➎
➎Square AW-Q1B AW-Q1B 1
➏Extended
with Full AW-QF1B AW-QF1B 1
Shroud
Aluminium Bezel AW-R1 AW-R1PN05 5 Aluminium color (standard)
➊ ➋ ➊Flush
AW-R1B AW-R1B 1 Black
R4
2.5
ø22.5 15 1.6t
(14/05/22) 33
ø22 TW Series Accessories and Replacement Parts
Maintenance Parts
Package
Shape Material Part No. Ordering No. Color Code
Quantity
Lens (for pilot lights) APW1L- APW1L-PN05 5 G (green), R (red), S (blue)
AS
APW1LD- APW1LD-PN05 5 A (amber), W (white), Y (yellow)
Round flush C (clear), G (green), R (red),
AS, APW11L- APW11L-PN05 5 S (blue)
Marking
APW11LD- APW11LD-PN05 5 A (amber), Y (yellow)
AS AVLW3L-R AVLW3L-RPN02 2
ø29mm mushroom AS,
AVLW31L-R AVLW31L-RPN02 2
Marking
ø40mm mushroom AS AVLW4L-R AVLW4L-RPN02 2
Button Round flush ABW1B- ABW1B-PN05 5
Round extended ABW2B- ABW2B-PN05 5 B (black)
G (green)
Square flush ABQW1B- ABQW1B-PN05 5 R (red)
Square extended ABQW2B- ABQW2B-PN05 5 S (blue)
W (white)
ø29mm mushroom ABW3B- ABW3B-PN02 2 Y (yellow)
Polyacetal
ø40mm mushroom ABW4B- ABW4B-PN02 2
ø29mm pushlock turn
AVW3B- AVW3B-PN02 2 R (red), Y (yellow)
reset
ø40mm pushlock turn
AVW4B- AVW4B-PN02 2 R (red), Y (yellow)
reset
B (black), G (green), R (red),
ø40mm push pull AYW4B- AYW4B-PN02 2 S (blue), W (white), Y (yellow)
Marking Plate
(for pilot lights) Round flush APW2B APW2BPN05 5
Marking Plate
(for illuminated Round extended ALW2B ALW2BPN05 5
pushbuttons) Acrylic • White
Waterproof Lens
For APQW APW00LN APW00LNPN05 5
Acrylic
For ALQW APW00L APW00LPN05 5
Note: Specify a button color code or lens color code in place of or in the Ordering No.
Use a clear lens for white or pure white illumination.
34 (14/05/22)
TW Series Accessories and Replacement Parts ø22
Maintenance Parts
Package Remarks
Shape Specification Part No. Ordering No.
Quantity Housing Push Rod
Contact Block
1NO contact HW-C10 HW-C10 1 Blue Green
EM contact
HW-C10R HW-C10R 1 Blue Black
(early make)
LB contact
HW-C01R HW-C01R 1 Purple red White
(late break)
Dummy Block
• Used for non-illuminated units with
TW-DB TW-DBPN10 10 1NO or 1NC contact blocks.
• Black
Base BA9S/13 1
18V AC/DC 1W (24V) LS-2
ø11±1
22.5 ±1.5
24V AC/DC 1W (30V) LS-3
(14/05/22) 35
ø22 TW Series Accessories and Replacement Parts
Transformer Unit
Shape Primary Voltage Secondary Voltage Part No.
Transformer Unit 100/110V AC TW-T16B
120V AC TW-T126B
5.5V
200/220V AC TW-T26B
240V AC TW-T246B
Transformer
Secondary
Shape Primary Voltage Part No. Applicable Load
Voltage
Din Rail Mount Transformer 100/110V AC TWR516
For 6V
115/120V AC TWR5126
200/220V AC TWR526
LSTD-6 LED lamp (6V AC/DC) or
230/240V AC 5.5V AC, 1W TWR5246
LS-6 incandescent lamp (6V AC/DC, 1W)
380V AC TWR5386
400/440V AC TWR546
480V AC TWR5486
Specifications Dimensions
100/110V AC, 115/120V AC, 200/220V AC,
M3.5 Terminal Screw
Operating Voltage 230/240V AC, 380V AC, 400/440V AC, 480V AC
(50/60Hz)
Current Draw 2.4 VA
SEC. 4
2
JAPAN
Secondary Side Primary Side
PRI.
Rated Insulation
22
30
600V
Voltage
3
45.5
Accessories
DIN Rail
Part No. Ordering No. Length Weight (approx.) Material Package Quantity
BAA1000 BAA1000PN10 1000 mm 200g Aluminum 10
BAP1000 BAP1000PN10 1000 mm 320g Steel 10
End Clip
Part No. Ordering No. Applicable DIN Rail Weight (approx.) Material Package Quantity Dimensions
(24)
BAA1000 Steel
BNL6 BNL6PN10 15g 10
BAP1000 (Zinc-plated)
45 9
• Use plastic end clip BC9Z-E/NS35N when using 400/440V AC primary voltage transformers.
36 (14/05/22)
TW Series Instructions ø22
Safety Precautions
• Turn off the power to the TW series switches & pilot lights • Use HW-C contact blocks for the TW series. Do not re-
before starting installation, removal, wiring, maintenance, place with or add conventional TW series contact blocks.
and inspection of the products. Failure to turn power off Using a different type of contact block may lead to
may cause electrical shocks or fire hazard. malfunction.
• To avoid a burn on your hand, use the lamp holder tool HW-C TW
when replacing lamps. Contact Block Contact Block
Instructions
Panel Mounting
Panel thickness adjustment ring is used for the TW series. To attach the TW series to the panel, follow the procedures below.
Attaching the Unit to the Panel Attaching the Button, Lens, and
Panel Thickness Adjustment with the Bezel Knob
Bezel
Mounting order
Installation method
Type Method
Flush/Extended pushbuttons,
Attach the unit with the panel Press in
Remarks Square lens, Selector operator
thickness scale facing up.
29mm/40mm mushroom
Screw in
button/lens, Dome lens
Adjusting Panel Thickness Using the Contact Block Removal Tool to Adjust Panel
Thickness
The panel thickness ring provides adjustment from 1 to 6 Panel thickness can easily be adjusted to the values shown
mm in 1-mm increments. Set the panel thickness to line A. below by inserting the contact block removal tool between
Rotate the ring until the desired thickness indication around the adjustment ring and base.
the periphery is aligned with line A, as shown below.
Scale on Adjustment (in 0.1 mm)
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0
A
2
3 3
4 4
5
6
5
6
1 mm
2 mm
3.2 mm
Ex. Panel thickness 2 mm Ex. Panel thickness 2.6 mm
(14/05/22) 37
ø22 TW Series Instructions
Mounting into Panel Cut-out with Bezel Square Bezel
1. Insert the base plate from
Insertion into Panel Cut-out the front. Base Plate
Insert the base into the panel
cut-out making sure that the
panel thickness scale is facing
up.
Panel thickness
adjustment ring
Tighten
Locking Ring Wrench
Nut Locking Wrench
OR-14 (optional)
Side A TW-KQ2 (optional)
21
21
19
[Square Pilot Lens] 4 3
ø1 ø1
1. Removing the Square Lens
Insert the screwdriver into the
Square Lens
1.0
1.2
2.6
Flat screwdriver
Marking Plate (5mm wide at
maximum) Note: The depth of the engraving must be within 0.5 mm.
Installing Round Lens and Waterproof Lens
When installing or removing round lens of pilot lights and
illuminated pushbuttons and waterproof lens of square pilot
2. Removing the Marking Plate lights and illuminated pushbuttons, press the rubber part of
[Square Illuminated Pushbutton] • Pilot Light the contact block removal tool onto the lens or waterproof
Insert the screwdriver into the lens for secure tightening and easy removal.
recess of the lens.
Square Lens
Press in
Marking Plate
Small flat screwdriver
Lens Retainer
Waterproof Lens
• Illuminated Pushbuttons
Insert the screwdriver into the
hook and lightly push out the
lens.
Flat screwdriver
(5mm wide at
[Round Marking] maximum)
Lens
3. Other Notes
Marking The square lens of the illumi
Plate nated pushbutton cannot be
used without waterproof lens.
Press in
Always use the waterproof
lens.
Be sure to use the marking
plate even when it is not
engraved.
38 (14/05/22)
TW Series Instructions ø22
Installation of Selector Operators Removing the Operator
1. The shaft of each selector or illuminated selector switch
1. Removing the Color
has a recess to identify in which direction to install the
Recess Insert
operator. Align the operator with the recess and press in
the operator. Insert a flat screwdriver
2. Press color insert (non-illuminated) into the operator. The into the recess of the color
color insert retains the operator insert. Turn the screwdriver
to push out the insert from
Color insert Flat the operator
Recess screwdriver
Press in
[Example]
L
C L
L R C
C
R
R
Standard Position
Barrier (HW-VL1)
(14/05/22) 39
ø22 TW Series Instructions
Installation of LED Illuminated Units
1. Note the polarity for wiring when connecting to DC-DC 3. Notes for Pure White LED Lamps
converter unit. • Do not use the pure white LED outdoors, otherwise it will
Terminal No. Polarity lead to the degradation of brightness and color. Do not
X1 Positive remove or apply shock to the cap on the pure white LED
X2 Negative lamp, otherwise it may break or damage the cap.
2. Transformer type units are recommended for use in areas • For the pure white LED, use a white lens. The illumination
subjected to noise. color will be dull if a different color is used.
The LED lamps are rated at 6V, 12V, or 24V AC/DC, and
can be used within ±10% the rated voltage of either AC or [Protection Example 2] For DC circuit
DC. +
Noise
Io
LED elements deteriorate due to extraneous noise, resulting
in significant decrease in luminance, hue change, or failure Io: Leakage current when the output is off
of lighting. When such effects are anticipated, take a protec R: Shunt resistor
Specifications and other descriptions in this brochure are subject to change without notice.
6-64, Nishi-Miyahara 2-Chome, Yodogawa-ku, Osaka 532-0004, Japan
Tel: +81-6-6398-2527, Fax: +81-6-6398-2547
E-mail: marketing@idec.co.jp
IDEC CORPORATION (USA) IDEC ELEKTROTECHNIK GmbH IDEC IZUMI (H.K.) CO., LTD.
1175 Elko Drive, Sunnyvale, CA 94089-2209, USA Wendenstrasse 331, 20537 Hamburg, Germany Unit G & H, 26/F., MG Tower,
Tel: +1-408-747-0550 / (800) 262-IDEC (4332) Tel: +49-40-25 30 54 - 0, Fax: +49-40-25 30 54 - 24 No. 133 Hoi Bun Road, Kwun Tong, Kowloon,
Fax: +1-408-744-9055 / (800) 635-6246 E-mail: service@idec.de Hong Kong
E-mail: opencontact@idec.com Tel: +852-2803-8989, Fax: +852-2565-0171
IDEC (SHANGHAI) CORPORATION E-mail: info@hk.idec.com
IDEC CANADA LIMITED Room 701-702 Chong Hing Finance Center,
3155 Pepper Mill Court, Unit 4 No. 288 Nanjing Road West, Shanghai 200003, PRC
IDEC TAIWAN CORPORATION
Mississauga, Ontario, L5L 4X7, Canada 8F-1, No. 79, Hsin Tai Wu Road, Sec. 1,
Tel: +86-21-6135-1515 Hsi-Chih District, 22101 New Taipei City, Taiwan
Tel: +1-905-890-8561, Toll Free: (800) 262-IDEC (4332) Fax: +86-21-6135-6225 / +86-21-6135-6226
Fax: +1-905-890-8562 Tel: +886-2-2698-3929, Fax: +886-2-2698-3931
E-mail: idec@cn.idec.com E-mail: service@tw.idec.com
E-mail: sales@ca.idec.com
IDEC AUSTRALIA PTY. LTD. IDEC (BEIJING) CORPORATION IDEC IZUMI ASIA PTE. LTD.
Unit 17, 104 Ferntree Gully Road, Room 211B, Tower B, The Grand Pacific Building, No. 31, Tannery Lane #05-01,
Oakleigh, Victoria 3166, Australia 8A Guanghua Road, Chaoyang District, HB Centre 2, Singapore 347788
Tel: +61-3-8523-5900, Toll Free: 1800-68-4332 Beijing 100026, PRC Tel: +65-6746-1155, Fax: +65-6844-5995
Fax: +61-3-8523-5999 Tel: +86-10-6581-6131, Fax: +86-10-6581-5119 E-mail: info@sg.idec.com
E-mail: sales@au.idec.com IDEC (SHENZHEN) CORPORATION IDEC ASIA (THAILAND) CO.,LTD.
IDEC ELECTRONICS LIMITED Unit AB-3B2, Tian Xiang Building, Tian’an Cyber Park, 20th Fl., Sorachai Bldg., No.23/78,
Unit 2, Beechwood, Chineham Business Park, Fu Tian District, Shenzhen, Guang Dong 518040, PRC Soi Sukhumvit 63, Sukhumvit Rd.,
Basingstoke, Hampshire RG24 8WA, UK Klongton-nua, Wattana, Bangkok 10110
Tel: +86-755-8356-2977, Fax: +86-755-8356-2944
Tel: +662-392-9765, Fax: +662-392-9768
Tel: +44-1256-321000, Fax: +44-1256-327755
www.idec.com E-mail: sales@uk.idec.com
E-mail: sales@th.idec.com