Basic Fire Safety & Emergency Evacuation


3
HSE KARNAL

Presentation Outlines

What is Fire.? 1 2 Types of Fire

Fire Fighting Equipment 3 4 Fire Fighting Method

Fire Prevention & Fire


5 6 Fire Alarm System
Protection

Emergency Evacuation 7 8 General Requirements


4
HSE KARNAL

01. What is Fire.?


Fire is a chemical reaction of three
components:

❖ Oxygen
❖ Fuel
❖ Heat
5
HSE KARNAL

Fire Triangle

o Fire Triangle or Combustion


Triangle is a sample model for
understanding the necessary
ingredients for fire.
6
HSE KARNAL

Fire Tetrahedron

Fire tetrahedron can be describe as


pyramid which is solid having four
faces:
❖ Oxygen
❖ Fuel
❖ Heat
❖ Chemical Reaction
7
HSE KARNAL

The Spread of Fire

o Direct contact - in their early


stage, fires spread most entirely
by contact of flame to
combustible object.

o Conduction – transferred of
heat through solid materials.
8
HSE KARNAL

The Spread of Fire

❖ Convection – transferred of
heat by air movement, hot air
rises due to reduced density

❖ Radiation – heat transferred


from one surface to another
across the space
9
HSE KARNAL

STAGES Incipient 3
Fully
Or Growth Developed
Decay
OF FIRE Ignition

4
10
HSE KARNAL

Common Causes of Fire

Cooking Electrical Distribution Explosives


Heating Equipment's
Equipment's Smoking
Equipment's

Electrical Oil, Kerosene. Gas Pow er


Appliances Petrol & Lubricants Leakages Storages
11
HSE KARNAL

END CHAPTTER 01
12
HSE KARNAL

02. Classification of Fire

CLASS - A : Combustible solid like Wood, Paper, Plastic, etc.

CLASS - B : Flammable Liquids & Greases like LPG, Diesel, etc.

CLASS - C : Involving Electrical fire.

CLASS - D : Metal Fires like aluminium, etc.

CLASS - K : Involving kitchen fire.


13
HSE KARNAL

END CHAPTTER 02
14
HSE KARNAL

Fire Fighting Equipment

Fire Beater 1 2 Fire Bucket

Fire Blanket 3 4 Fire Extinguisher

Fire Ball 5 6 Fire Hose Reel

Fire Hydrant 7 8 Fire Sprinkler


15
HSE KARNAL

Fire Fighting Equipment

01. Fire Beater 02. Fire Bucket

A simple tool for fighting A Fire Bucket is filled with


wildfires, consisting of a sand or water and is used
piece of rubber at the to extinguish fires.
end of a pole.
16
HSE KARNAL

Fire Fighting Equipment

03. Fire Blanket 04. Fire Ball

A sheet of flexible material, A round-shaped fire extinguisher


typically woven fiberglass, that self-activates after about
used to smother a fire in an three to five seconds of fire
emergency. exposure.
17
HSE KARNAL

Fire Fighting Equipment

05. Fire Hose 06. Fire Hydrant

Fire hose reel is a flexible pipe Fire hydrants are used to


that is rolled and has a direct extinguish and control the
connection to the water. spread of fire.
18
HSE KARNAL

Fire Fighting Equipment

07. Sprinklers 06. Extinguisher

Fire sprinkler system is an Fire extinguisher is a portable or


automatic extinguishing system movable apparatus used to put
that prevent fire growth. out a small.
19
HSE KARNAL

Fire Fighting Equipment

Types of Extinguisher & Color Code & Uses

Water DCP CO2


CLASS- A CLASS- A,B,C CLASS- B,C

X
CLASS- B,C
X
CLASS- A,D

Foam W. C
CLASS- A,B X
CLASS- C CLASS- A,K
20
HSE KARNAL

Fire Fighting Equipment

Fire Extinguisher Operating Procedure

P A S S

Pull the Squeeze Sweep side


Aim the
safety the by side
target
pin trigger
21
HSE KARNAL

Fire Fighting Equipment


Fire Extinguisher Using TIPs
❖Check for your own safety before starting to extinguish a fire.
❖Assess the fire only a small fire should be fought using a fire extinguisher
❖Select the right type of fire extinguisher.
❖Remember the simple acronym P.A.S.S. : Pull, Aim, Squeeze, Sweep,
❖Always try to work in pair for safety.
❖Target the base of the fire not the flame.
❖If fire extinguished at first sight, stay ready for re-ignition.
❖Keep minimum 8-10 feet distance from fire during use fire extinguisher.
22
HSE KARNAL

Fire Fighting Equipment

Fire Hydrant Color Code & Class

CLASS - AA CLASS - A CLASS - B CLASS - C


1500 GPM 1000-1499 GPM 500-999 GPM 500 GPM
23
HSE KARNAL

Fire Fighting Equipment

Fire Sprinkler Types & Color Code

Open Fire Sprinkler: Closed Fire Sprinkler:


Sprinkler that is not equipped with actuator Sprinkler that is equipped with actuator or
or heat response element. heat response element.
24
HSE KARNAL

Fire Fighting Equipment

Fire Sprinkler Types & Color Code

57 C/ 135 F

68 C / 155 F

79 C / 175 F

93 C / 200 F
141 C / 286 F

182 C / 360 F

NOTE: Quick Response - 3MM bulb, Standard Response - 5MM bulb


25
HSE KARNAL

Fire Fighting Equipment

Percolating Hose

Delivery Hose Non-Percolate

Hose Reel Hose


Types of Hose
Soft Suction
Suction Hose Hard Suction
Partially Embedded
Fully Embedded
26
HSE KARNAL

Fire Fighting Equipment


Soft Suction:
Percolating: Dimension- 102, 127 mm
Type of Hose Dimension- 38,50,63,70 mm Length- 8 to 15 meter.
Length- 15,22.5,30 meter.

Non-Percolating:
Dimension- 38,50,63,70 mm Partially Embedded:
Length- 15,22.5,30 meter. Dimension- 75, 100,140 mm
Length- 2.5 to 3 meter.

Hose Reel Hose: Fully Embedded:


Dimension- 19 mm Dimension- 75, 100,140 mm
Length- 30 to 60 meter. Length- 2.5 to 3 meter.
27
HSE KARNAL

END CHAPTTER 03
28
HSE KARNAL

Fire Extinguishing Method

01 02 03

Starvation Smothering Cooling


29
HSE KARNAL

Fire Extinguishing Method

Starvation

Starvation is the process of depriving the


fire from fuel. i.e. combustible materials.
Or
Remove fuel from fire.
30
HSE KARNAL

Fire Extinguishing Method

Smothering

Smothering is the process of depriving the


fire of oxygen needed to sustain the fire.
Or
Remove Oxygen from fire.
31
HSE KARNAL

Fire Extinguishing Method

Cooling

Cooling is the process of depriving the fire


of Heat e.g. by applying a substance such
as water that will absorb heat from the fire.
Or
Remove heat from fire.
32
HSE KARNAL

END CHAPTTER 04
33
HSE KARNAL

Fire Prevention & Fire Protection

01. Fire Prevention:


It is a proactive steps taken to reduce fire
hazards so that a fire does not have a
chance to ignite.

02. Fire Protection:


It is a reactive approach which minimize
potential damage or loss.
34
HSE KARNAL

Fire Prevention & Fire Protection

01. Fire Prevention


o Fire safety plan (approved)
o Risk assessment (update every 6 month)
o Workplace Inspections (daily, weekly, monthly, quarterly)
o Fire safety trainings (induction, annually)
o Regular fire drills
o Preventive maintenance (as per requirements)
o Housekeeping Management
o Material Management (5-S Technique)
35
HSE KARNAL

Fire Prevention & Fire Protection

02. Fire Protection

Active Fire Protection:


Active fire protection system is detect and extinguish a
fire. This can be either manual or automatic.

Passive Fire Protection:


Passive fire protection system will help to prevent fire
from spreading or resist the initial ignition.
36
HSE KARNAL

Fire Prevention & Fire Protection

Active Fire Protection Passive Fire Protection

o Smoke and heat alarm o Compartment


o Manual Call Point o Fire proofing
o Fire Sprinklers o Fire door
o Fire extinguishers o Fire wall
o Fire hydrants o Fire Stopper
o Video monitoring o Fire Curtain / Baffle
o Etc. o Etc.
37
HSE KARNAL

END CHAPTTER 05
38
HSE KARNAL

Fire Alarm System


Fire Alarm Control Panel:
A fire panel is a safety appliance that
receives information from devices
designed to detect and report fires,
monitor their operational integrity.
39
HSE KARNAL

Fire Alarm System


Types of Fire Alarm System

Conventional fire Panel: Addressable fire Panel:


Every device on the same It indicate the exact
circuit would report the same. location of fire or smoke.
40
HSE KARNAL

Fire Alarm System


Fire Detectors

Fire Detectors:
A device which can detect a fire, and provide a signal to an alarm circuit.
Fire detectors are different types;

1. Smoke Detectors
2. Heat Detectors
3. Flame Detectors
41
HSE KARNAL

Fire Alarm System


Types of Fire Detectors

Ionization SD

1.Smoke Detector Light Obstruction

Photoelectric SD

Light Scattering
42
HSE KARNAL

Fire Alarm System


Types of Fire Detectors

Fixed Temp HD

2. Heat Detector

Rate Of Rise HD
43
HSE KARNAL

Fire Alarm System


Types of Fire Detectors

IR Detector

3. Flame Detector

UV Detector
44
HSE KARNAL

Fire Alarm System


Manual Call Point

o It is a device used to initiate an alarm signal.


o They operate by means of a simple button press or when glass is broken
revealing a button.
o They can form part of a manual alarm system or an automatic alarm system.
o MCP activation is typically achieved through the use of a pull station or call
point which then sounds the evacuation alarm for the relevant building or zone.
45
HSE KARNAL

Fire Alarm System


Types of MCP
Push Type MCP

Manual Call Point Pull Type MCP

Glass Break MCP


46
HSE KARNAL

END CHAPTTER 06
47
HSE KARNAL

Fire Evacuation Procedure


Action on Hearing Alarm

• Don’t panic and be calm.


• Stop any activity immediately and prepare to leave the
room.
• Turn off all ignition sources such as AC, Equipment.
• Evacuate the room to nearest safe assembly area.
• Remain in the assembly area (in group) until instructed to
leave.
• After the all clear alarm you may continue your work.
48
HSE KARNAL

Fire Evacuation Procedure


Assembly Area Checklist

▪ All the employee assemble at their designated


assembly area.
▪ Assembly area far enough away from flying glass and
other objects
▪ Head count of Employees is done and reported to ERT
head.
▪ Injured are informed to the ERT Team.
▪ Access to emergency vehicles are not hindered
▪ Remain in the group until further notice.
▪ Do not re enter in building without permission.
49
HSE KARNAL

Fire Evacuation Procedure


Emergency Reporting

1. Call 911 and say this is an emergency.

2. Describe the incident location.


3. Describe the nature of incident.

4. Report injuries if any.


5. Give you name, badge number and contact.

6. Repeat the above information.


7. Stay on the line until further instructed.
50
HSE KARNAL

Fire Evacuation Procedure


RACE Method

R Rescue – rescue who is in immediate danger.

A Alert – Activate fire alarm (or) Dial emergency phone number.

C Contain/Confine– Close all doors and windows when evacuate,

E Extinguish/ Evacuate – Extinguish if small fires, if not then evacuate.


51
HSE KARNAL

Fire Evacuation Procedure


Duties of ERT

o All Fire Equipment's are always in working condition. Any deviation needs to
be reported to Facilities/Security Team.
o ERT should know the locations of Fire Extinguishers and their handling
techniques
o ERT is to help Security/Fire Team in case of any Fire incident.
o ERT needs to ensure that emergency situations are handled peacefully and
authoritatively without any stampede.
o ERT should know the details of Handicap person(s) and their workstation and
contact details.
o While evacuation of employees, priority to be given to disabled employees,
pregnant ladies and visitors.
52
HSE KARNAL

Fire Evacuation Procedure


Duties of ERT

o ERT assess the situation at the scene itself.


o If situation is not risky and can be controlled without any human safety risk then
control same.
o In case situation warrants to evacuate the building, start evacuation with
assistance of team members and simultaneously inform ERT Leader/Office
Head for assistance or guidance.
o Follow the instructions of ERT Leader/Office Head and handle it appropriately.
HSE KARNAL 53

Fire Evacuation Procedure


If your clothes are on fire:

Don’t run – it will Get down onto the Roll over -


make the fire floor this will put the flames
worse! out
1 2 3
54
HSE KARNAL

END CHAPTTER 07
55
HSE KARNAL

Fire Safety General Requirements


• Storage of flammable and combustible materials shall be minimum
• Incompatible materials (flammable and oxidizer) shall not be stored together
• Vegetation (weeds &grass)shall kept down
• Minimum clearance of 0.6m or 2ft shall be maintained between the ceiling and
the top level of any stocked material below
• Minimum 0.5m or 1.5ft clearance between top level of stocked material and
sprinkler head
• Temporary wiring shall be installed according to the provision of NFPA 70.
• Electrical equipment should be regularly checked
56
HSE KARNAL

Fire Safety General Requirements


• GFCI (Ground Fault Circuit Interrupters) shall be provided where required.
• Smoking is permitted only in designated “Smoking Area”
• Open fires or open burning of materials are strictly prohibited.
• Proper bonding & grounding techniques shall be used for any operation.
• Trained and certified Fire Watch should be present all the at hot work area.
• Monthly inspection of all FACP and Fire Fighting equipment.
• CO2 fire extinguisher is prohibited to use in Confined Space.
57
HSE KARNAL

END CHAPTTER 08
58