JG 0.460 (38) [2.2°] 0.500 (42) [2.4°] 0.215 (18) [1.0°] 0.500 (42) [2.4°] N/A
JGA 0.500 (42) [2.4° 0.500 (42) [2.4°] 0.310 (26) [1.5°] 0.500 (42) [2.4°] 0.190 (16) [0.9] 0.500 (42) [2.4°]
JGW:R 0.095 (7.9) [0.45°] 0.500 (42) [2.4°] 0.025 (2.1) [0.1°] 0.500 (42) [2.4°] N/A
JGJ 0.420 (35) [2°] 0.500 (42) [2.4°] 0.105 (8.7) [0.5°] 0.450 (37) [2.1°] 0.065 (5.4) [0.3°] 0.460 (38) [2.2°]
JGH 0.375 (31) [2°] 0.500 (42) [2.4°] 0.160 (13) [0.8°] 0.500 (42) [2.4°] N/A
JGE:T 0.440 (37) [2.1°] 0.500 (42) [2.4°] 0.155 (13) [0.7°] 0.500 (42) [2.4°] 0.090 (7.5) [0.4°] 0.310 (26) [1.5°]
JGK 0.105 (8.7) [0.5°] 0.500 (42) [2.4°] 0.035 (2.9) [0.2°] 0.500 (42) [2.4°] 0.020 (1.7) [0.1°] 0.310 (26) [1.5°]
KBK 0.165 (14) [0.8°] 0.410 (34) [2.0°] 0.065 (5.4) [0.3°] 0.280 (23) [1.3°] 0.040 (3.3) [0.2°] 0.345 (29) [1.6°]
KBT 0.445 (37) [2.1°] 0.480 (40) [2.3°] 0.170 (14) [0.8°] 0.410 (34) [2.0°] 0.105 (8.7) [0.5°] 0.345 (29) [1.6°]
JGC 0.270 (22) [1.3°] 0.460 (38) [2.2°] 0.100 (8.3) [0.5°] 0.460 (38) [2.2°] 0.060 (5.0) [0.3°] 0.180 (15) [0.9°]
JGD 0.500 (42) [2.4°] 0.460 (38) [2.2°] 0.205 (17) [1.0°] 0.460 (38) [2.2°] 0.125 (10) [0.6°] 0.180 (15) [0.9°]
JGF 0.500 (42) [2.4°] 0.460 (38) [2.2°] 0.260 (22) [1.2°] 0.460 (38) [2.2°] 0.155 (13) [0.7°] 0.180 (15) [0.9°]
JGZ, KBZ 0.500 (42) [2.4°] 0.500 (42) [2.4°] 0.380 (25) [1.8°] 0.500 (42) [2.4°] 0.240 (20) [1.1°] 0.500 (42) [2.4°]
JGU, KBU 0.500 (42) [2.4°] 0.500 (42) [2.4°] 0.475 (40) [2.3°] 0.500 (42) [2.4°] 0.300 (25) [1.4°] 0.500 (42) [2.4°]
JGB N/A 0.250 (21) [1.2°] 0.075 (6.2) [0.4°] 0.180 (15) [0.9°] 0.075 (6.2) [0.4°]
JGV N/A 0.235 (20) [1.1°] 0.075 (6.2) [0.4°] 0.150 (12) [0.7°] 0.075 (6.2) [0.4°]
KBB:V N/A 0.165 (14) [0.8°] 0.500 (42) [2.4°] 0.120 (10) [0.6°] 0.500 (42) [2.4°]
With a dry sump, drains are supplied at each end of JGH 3.5° 2° N/A
the compressor frame and an additional oil pump JGE:T 4° 1.5° 1°
chain oiler is provided by Ariel. The packager must
provide a lube oil reservoir sized and located so that JGK 1° Use Dry Sumpb Use Dry Sumpb
the oil pump has oil suction regardless of the tilt of KBK 3° Use Dry Sumpb Use Dry Sumpb
the ship or floating platform. An oil sump strainer
must be installed in the pump suction line at the KBT 7.5° 2° 1°
outlet of the separate lube oil reservoir (unmounted JGC 4° 1° Use Dry Sumpb
strainer is provided by Ariel with a new dry sump
JGD 5.5° 2.5° 1°
compressor). Refer to the Ariel outline drawings for
connection sizes and locations. JGF 5° 3° 1.5°
4-3-18 4 201800258 Page 1, Table 1: “JGP:Q, KB100” was “JGP:Q”; added “KBK, 0.165 (14) [0.8°],
0.410 (34) [2.0°], 0.065 (5.4) [0.3°], 0.280 (23) [1.3°], 0.040 (3.3) [0.2°], 0.345
(29) [1.6°]”; added “KBT, 0.445 (37) [2.1°], 0.480 (40) [2.3°], 0.170 (14) [0.8°],
0.410 (34) [2.0°], 0.105 (8.7) [0.5°], 0.345 (29) [1.6°]”. Page 2, Table 2:
“JGM:P:N:Q, KB100” was “JGM:P:N:Q”; added “KBK, 3°, Use Dry Sumpb,