General Notes:
1. Project Managed Orders (Tier 2 & 3): The proposed change order charges and delivery impact will be determined by
the world area change order owner, based on the milestone schedule outlined below. Any appeals should be taken to
the Project Manager or Project Administrator for resolution.
2. Non−Project Managed Orders (Tier 1 & MRO): The world area change order pricing contact is responsible for the
change order fee and delivery impact. Contact your world area Change Order Owner.
Any appeals should be taken to the appropriate Sales Support organization in your world area for resolution.
1. Processing Charge:
All prices are “Net” with 25% commission for processing charges shown below. Charges related to construction changes
are per standard commission tables. Definitions of the below categories are located below in this document. For EU and
MEA convert to list and enter in FF2.
Change Order Charge Category(3)
Milestone Description Status in
Flex/Oracle Soft Non− Minor Major
Change(4) Construction(1) Construction Construction
Sales Order Order Detailing and/or
Booked No Charge $150 per item $150 per item $150 per item
Entered Engineering
Material Promise ship date set, $300 + 10%
Supply
Plan material orders being No Charge $300 per item of component Consult Factory(2)
Completed placed on suppliers Eligible selling price
$450 + 20%
Released to Parts are quickly being Production
No Charge $450 per unit of component Consult Factory(2)
Assembly assembled and more Open selling price
$450 + 30%
Assembly Completed assembly Awaiting $450 + 2% of unit
No Charge of component Consult Factory(2)
Completed and/or crated Shipping selling price
selling price
1. The first actuator and/or positioner orientation change with no material change is no charge if made before Release to Assembly.
2. The processing charge will also include charges for scrap and rework, if applicable.
3. If multiple changes are made to the same item, use the highest change category for the charge.
4. $100 per item will be charged for Customer Purchase Order (PO) changes made within 3 weeks prior to the Customer Request
Ship Date.
QUOTE Validity:
Change request quotations will be honored for 5 business days, while we “Proceed” with the order.
If the order is placed on “hold”, the quotation will be honored for 30 business days. Note that items on hold may incur delay
charges.
Longer validity periods need to be quoted by the appropriate Change Order Owner via Flex.
Delays caused by the customer will result in adjusting factory promise dates once item(s) have been ordered.
The customer should be informed of this charge when the valve is placed on hold. The chargeable amount will be
evaluated at the time the items are released from hold. Delay charges for partial months will be assessed at their full
monthly rate. All prices are “NET” with 25% commission for processing charges.
Price per Month(1)
Status in On hold with a On hold with a On hold with a
Milestone Description
Flex/Oracle cumulative cumulative duration cumulative duration of
duration of 30 days of 60 days more than 60 days
Sales Order Order Detailing and/or
Booked No Charge(2)
Entered Engineering
Promise ship date set,
Material Plan Supply
material orders being No Charge(2) See below note(3) See below note(4)
Completed Eligible
placed on suppliers
Released to Parts are quickly being Production
See below note(3) See below note(3) See below note(4)
Assembly assembled and more Open
Assembly Completed assembly Awaiting
See below note(3) See below note(3) See below note(4)
Completed and/or crated Shipping
1. (FF2 Note) In case, a different contractual agreement is established for the order, the established contract will take precedent.
2. (FF2 Note) The charges will be applicable if pre-ordering had been done as per request from the Impact Partners / LBP/ Sales. Consult
factory for the applicable charges.
3. (FF2 Note) 2% of unit selling price per month - minimum $350 charge applies.
4. (FF2 Note) 5% of unit selling price per month - minimum $850 charge applies.
• Emerson reserves the right to reject the hold request by the sales office should it be determined to be not feasible
and will continue to execute the order. For this case, the storage delay charges section in OED II shall be applied.
• If feasible, order delay charges quotations shall be sent to sales office. Change request with charges shall be
entered within the 7 calendar days validity period.
• If change request is not received within the validity period, then the factory will continue to execute the order until
the change request is received. The chargeable amount will be evaluated based on the order status at the time of
receiving the change request.
Hold Definition:
For all change order quotations, the item will “Proceed”, until the order is officially placed on “Hold” by issuing a Hold Change
Order by the sales office. The following below definitions apply.
Proceed (Default) − All work will continue as if no change was coming. The customer will be responsible for any
additional charges that will be incurred due to the work being continued beyond the change order quote validity period.
Hold − All work will stop if possible. All front end activities (order entry, engineering, and drafting) are stopped; all supplier
PO’s are placed on hold (due to timing some PO’s are not able to be put on hold); machining, assembly, and boxing
activities are stopped if possible. The customer needs to be informed that lead time on documentation and equipment
will be affected. Customer is responsible for any cost incurred up to the point of the hold being placed, this includes
non−stock materials, order engineering and drafting work that is no longer useable based on the customer change.
Soft Change:
This type of change typically doesn’t affect order engineering or manufacturing, unless it delays shipment.
Examples:
D PO Change D Inspection waived
D Ship to Address D Requested ship date changed (may be subject to storage
D Ship via (method) fees)
D Ship Notes D Add expediting fees
D Forwarder information/Export information changed D Do not ship before date change (may be subject to storage
D Project Services (e.g., PMF−023) fees)
D Territory Commission D Pricing
D Add CRN cert (Canadian Registration Number) D Add NACE Cert with no part number change
Non−Construction Change:
This type of change affects order engineering and involves an order or order/item change. However, risk of material
scrap is low. Manufacturing rework costs are low if prior to release to assembly. Examples:
D Orientation (instrument, actuator & handwheel) − D Signature Series
with no material change
D Drawing added or drawing requirement changed D Flow direction
D Tubing & Fittings (from standard) D Unit measurement (PSNP option)
D Tag or Nameplate change D PSID codes or documentation added
D DVC diagnostic tier D Witness inspection
D Change paint (from standard) D Change of boxing type / packaging
D Add epoxy paint report D Add DFT Witness (Dry Film Witness)
D Bench set (without spring change) D Add Certs (non−CSP)
D Add instrument D Leakage class (without construction change)
D Add M20 adaptor D Add sunshade
D Change gland packing material (from standard) D Add instrument or accessory mounting
D Add NACE Cert with part number change
Minor Construction Change (for standard OED I valves in WCC, LCC, or CF8M):
This type of change affects ordering engineering, material sourcing, and manufacturing where the scrap and rework
material costs are relatively minor compared to the effort to implement the change. Examples:
D Orientation change spring & diaphragm actuator, including instruments with material changes
D Bench set (with spring change)
D Trim change: NPS 1 to 6 (standard trim only, e.g., Linear, EQ%, Quick Opening and trims which don’t need
engineering. Severe service trim is not applicable)
D Fisher actuator change of model, size, travel, fail mode with no change in valve yoke boss size
D Change bolting material (from standard)
D Change stem/shaft material/size (from standard)
D Leakage class (with trim modification)
D Change / add / remove standard airset
D Add accessory (solenoid, booster, etc.)
D Add packing
D Change instrument mounting
Cancellation Change Order charges are comprised of the following two costs:
Non−forecasted or special ordered parts / components cost:
The cost for non−forecasted, customer special, or buyout parts and components is determined at the time of the cancellation. This
cost will be added to the above charges based on the manufacturing costs incurred up to that point.
All non−forecasted or special buyout parts / components which have been procured or manufactured for a now cancelled order
will be scrapped within 30 days. These products are not available for purchase by the customer at the cancellation charge.
Final cost will be determined by the Change Order Owner.
Assembly cost:
The assembly cost is determined by said order’s status within the factory assembly cycle. The stages and corresponding
percentages of invoice value are:
Assembly Cycle Stage Cancellation Costs
After receipt of order/prior to release to Mfg. 10% or $175 minimum
Released to Manufacturing 20% of Invoice Value
Units Built (but not yet boxed) 25% of Invoice Value
Boxed (ready to be shipped) 30% of Invoice Value
Plus any cost of non−standard boxing
A cancellation is defined as each reduction in quantity of models or part numbers per order.
The first resize is free of charge, all other resizing and selection engineering is chargeable. The resize and selection charge
covers resubmiital of the data sheets and calculations as part of the calculation, even if product doesn’t change.
These options only apply to process conditions or data sheet changes made after order award.
Offering Tiers Non−Standard
(FF2 Drop Down) Description LBP Commission Price Per Tag
Engineering Services − First Resize Resize & Select / Engineering Services 0% $0(1)
Engineering Services − Additional Additional review & resize based on
90% $240
Review & Resize process condition changes
1. Included as standard.
Product Technical
Order Entry Document Volume II
Product Technical
FEED Sizing and Selection Work:
Local office or in−house (customer based) support for sizing and selection works (spec sheets and drawings will be in PDF
format or as defined in the Emerson Document Management Index (EDDI). Item cannot be buried in the price of the valve.
This option can only be quoted/ordered as a standalone item.
If process data sheet changes or additions occur after the PO is issued, refer to the change management services price
page for Resize & Select Engineering charges to review and comment on the specification. See OED II, Section 5. All prices
shown are non−standard.
Non−Standard
Offering Tiers Description LBP Commission Price
Front end engineering and design sizing
Sizing and Selection Works 90% $393
and selection services.
In−house − Sizing & Selection Feed Sizing and Selection Work − at the
90% $3,272
Engineering Services customer’s office
Control Valve Spec Sheet Data for Intergraph SmartPlantt Instrumentation (SPI)
Many EPC’s use Intergraph SmartPlant Instrumentation (SPI) to specify instrumentation such as control valves when
designing process plants. SPI is used by over 80% of EPC’s.
Fisher and Intergraph have standardized on a “FF2−to−SPI data file” to transfer control valve spec sheet data from Fisher
First 2 (FF2) into Intergraph SmartPlant Instrumentation (SPI). The same “FF2−to−SPI data file” can be used to populate
either the Fisher control valve specification sheet (SPI Form 90) or an EPC’s custom control valve spec sheet form in SPI.
To import into SPI, the EPC must have Intergraph SPI 2009 or later.
Non−Standard Price (standard base discount or market factor applies) with 10% commission.
Special DDP:
This Special DDP file is intended for EPC’s that use a different piping design system. The EPC will provide the empty DDP
file (Excel file), along with drawings of various 3D shapes that visually define each dimension variable, such as the
face−to−face. Fisher will manually populate the valve envelope dimensions into this Special DDP Excel file.
Non−Standard Price (standard base discount or market factor applies) with 10% commission.
Product Technical
Order Entry Document Volume II
Optimization Meeting:
The local sales office, supported by factory experts, can perform tag−by−tag sizing, selection and application review to en-
sure the lowest price item has been selected. In some cases, a lower price item that may meet the intent of the specification
could be identified.
Non−Standard
Offering Tiers Description LBP Commission Price Per Tag
Detailed specification review to identify
Optimization Meeting optimum valve solutions for complex 10% Consult Factory
applications and project specifications
Drawing Definitions
Order Entry Document Volume II
Drawing Definitions
LEVEL 4
Cross−section, BOM & RSPL of Fisher Actuator
LEVEL 3
Center of Gravity
Cross−section, BOM & RSPL of Valve Body Assembly
Level 2
Accessories
Pneumatic Hookup Schematic
Volume Tanks (w/o accessories)
Serial Number
High Level Component BOM
Drawing Number and Rev
OUTLINE DRAWINGS
(On Demand from FF2(1))
Outline Dimensions
Positioner Orientation
Assembly Weight (+/−10%)
Standard Title Block
Actuator Removal Clearance
Customer Special Notes (Opt.)
Drawing Number and Rev (Opt.)
1. These drawings are available on−demand to all FF2 users. Any Outline Drawings not available in FF2 will be made available on
priority after request.
Outline Drawings:
An exterior view drawing of Fisher valve product or product assembly up to valve, actuator, positioner and regulator (if
selected with positioner component). These drawings are dimensioned to show necessary installation and “envelope”
information needed to complete piping design work or for final customer drawings direct from FF2. Users have the ability
to insert any special notes and/or assign drawing number/revision as may be required per customer specification.
Level 2 Drawings:
An exterior view drawing of Fisher valve, actuator, positioner and other accessories (as ordered). This drawing also includes
pneumatic hook up schematic, volume tank (if volume. tank accessories need to be shown in the drawing, appropriate option
needs to be selected) and a high level BOM (list of components ordered in the assembly). Drawings are pictorially typical
to the Fisher order serial card &/or entered per the customer notes. Drawing number, revision levels and serial numbers
are assigned in the title block.
Level 3 Drawings:
In addition to details included in base Level 2 Drawings, these drawings include a cross−sectional view of valve body,
bonnet, packing and trim pats including a BOM showing Fisher part numbers, part names and material specification for parts
shown along with recommended spares. This drawing may be used for product/part traceability.
Level 4 Drawings:
In addition to details included in base Level 3 Drawings, these drawings include a cross−sectional view of Fisher Actuator,
BOM showing Fisher part numbers, part names and material spec along with recommended spares. This drawing may be
used for product/part traceability.
Notes:
1. See OEDII Section 5 for pricing and full list of orderable options along with Level 2, 3, and 4 drawings.
2. For pre−ordering drawing products like 3D models, DDP (Dimensional Data for Piping) and to request
drawings for equipment already shipped, please see OEDII Section 5.
3. When an order has Rep furnished accessories/mountings, prior communication is required. Emerson Impact
Partner shall provide needed drawing and model information. Otherwise there will be parts not shown.
Description
PSID Codes Base Drawing Type Non−Std Price/Item
PSID−900 Level 2 (FLEx Documentation site) $236
PSID−901 Level 3 (FLEx Documentation site) $588
PSID−902 Level 4 (FLEx Documentation site) $3,532
PSID−903 3D CAD model file (.stp or STEP is default file format)(1) (Consult World Area $383
Drawing Team for availability)(13)
PSID−099 Special request(2) CF
PSIDE−210 Special General Arrangement drawings and Cross Sectional drawings c/w/ parts $2,685
list according to Statoil Frame agreement (Europe only)
Dimensions
PSID−905 English / Imperial $0
PSID−906 Metric $0
PSID−907 Dual − English (Imperial) &Metric $59
Options(3)
PSID Codes Language Non−Std Price/Item
None (default is ENGLISH) $0
PSID−908 Dwg Language French $88
PSID−909 Dwg Language Russian $88
PSID−910 Dwg Language Spanish $88
PSID−911 Dwg Language OTHER(4) $88
PSID−DL−1 Dwg Language English & French − Same sheet(14) $127
PSID−DL−2 Dwg Language English & Russian − Same sheet(14) $127
PSID−DL−3 Dwg Language English & Spanish − Same sheet(14) $127
PSID−DL−4 Dwg Language English & Other − Same sheet(14) CF
PSID−DL−5 Dwg Language English & French − Separate sheets(15) $170
PSID−DL−6 Dwg Language English & Russian − Separate sheets(15) $170
PSID−DL−7 Dwg Language English & Spanish − Separate sheets(15) $170
PSID−DL−8 Dwg Language English & Other − Separate sheets(15) CF
PSID−DL−9 Dwg Language Other & Other CF
PSID Codes Additional Content (Multiple Selectability) Non−Std Price/Item
PSID−912 Center of Gravity(5) $59
PSID−913 Special Butt−Weld End Preparation Details $59
PSID−914 Volume Tank Accessories(6) / Rep Supplied Accessories $59
PSID−915 Wiring Diagram (Customer Provided) $88
PSID−916 Additional Customer Special Notes(7) $88
PSID−917 Customer Title Block(8) $88
PSID−918 Nameplate/Warning Tags(9) $117
PSID−919 Lubricant Call−Outs(10) $117
PSID Codes Format (Multiple Selectability) Non−Std Price/Item
None (Default is Electronic PDF) $0
PSID−920 First Paper Copy $236
PSID−921 Additional Paper Copies(11 $59/Copy
PSID−922 2D CAD (.dwg or .dxf) $117
- Continued -
Description (Continued)
PSID Codes Format (Multiple Selectability) (Continued) Non−Std Price/Item
PSID−216 Customer Approval of Dimensional Drawings(12) No Extra
Note: This hold stops the release of item(s) to assembly process in manufactur-
ing but allows for procurement of materials.
1. Please specify in D51 note if alternate file format required. Charges/services line may be used to order this before a product
order is placed.
2. For special requests, please contact SDSE/GIS. You must enter PSID−099 code with a price and a D51 note on the
order / Item specifying the drawing requirements, SPL reference (if any) and quantity of copies required. Pricing will be
determined by SDSE/GIS. A R05 pricing note must be included on the item specifying the authorizing SDSE/GIS person and
price.
3. A base PSID code for a drawing must be ordered before an optional code may be selected.
4. Please specify in D51 note.
5. Selectable only with Level 2 drawing. Provided by default in Level 3 and Level 4 drawings.
6. Relief valves, gauges, drain valves (when purchased).
7. Include this option if you wish to request additional notes in drawing (beyond the notes added in FF2
drawings). Use D51 note.
8. Applicable if customer’s own title block needs to be added with Fisher title block. Requires .DWG or .DXF file
from customer.
9. Nameplates and warning/caution tag information for valve and actuator.
10. Applicable only to Level 3 or 4. Lubricants and their application points are identified in sectional views shown in
drawing.
11. Use PSID−920 to order a paper copy of any drawing type. If additional copies are required, please use
PSID−921. Charges for each additional copy/item will apply as applicable.
12. Item(s) cannot be released to assembly until this hold is released. To remove this hold a message should be
communicated to the manufacturing site service contact. For project managed orders, message should be sent to
Project Manager or Project Administrator. Does not require a base drawing type.
13. Contact DL3DADSModelsSupport@Emerson.com for 3D model availability of selected product before order
placement. Or contact your World Area Customer Drawing Team for 3D availability for select product(s) before order
placement − http://mtndocs.mt.na.emersonprocess.com/CDDT/wy_cddt_contacts
14. Both languages are added on the same sheet of drawings.
15. Separate sheets for both languages selected (Multiple Sheets for one drawing).
LEAD TIMES:
For lead time information, please contact Customer Drawing Teams of your respective world areas through common
mailboxes listed at http://mtndocs.mt.na.emersonprocess.com/CDDT/wy_cddt_contacts.
NOTE 1: For A4 (metric) RSPPL copies furnished and mailed by factory, specify with a D51 note.
MISCELLANEOUS
D Extra Transmittal Letters
PSID-036 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No Extra
D Special Documents Required (Specify using note D51)
PSID-099 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contact Global Industry Inside Sales or Project Management
NO COMMISSION IS AVAILABLE
SPECIAL SERVICE CODES FOR ON−LINE AND CONVENTIONAL PAPER CONSOLIDATED INSTRUCTION
MANUALS
CONSOLIDATED INSTRUCTION MANUALS, DRAWINGS, BULLETINS, SERIAL CARDS, AND RSPPL’s −ON−LINE
PROJECT DOCUMENTATION
Web access is available for instruction manuals, bulletins, serial cards, RSPPLs and BOMs. Select the appropriate PSID codes
as identified in the chart below for consolidated instruction manuals. Select the appropriate PSID code to view RSPPLs and BOMs.
PSID−084 (no charge) will also generate these documents on the web for an order and should be used if so desired and neither
drawings nor instruction manuals are required on the order.
Use the instruction below for single and multiple order consolidations. See
http://mtndocs.mt.na.emersonprocess.com/Sales__Development___Support/eBusinessSDS/sds_wy_projectdocumentation
for more details and access to this “Project Documentation” website.
As a standard, one copy of FCS instruction manuals is packed with each product shipped. If the customer requires additional copies
to be mailed, use the consolidated instruction manual special service code PSID-565 or PSID−566 in N. America or PSID−065 or
PSID−465 in other world areas to request additional manuals. PSID-065, PSID-465, PSID−565, or PSID−566 consolidates all the
items on an order, a series of orders, or a project. For example, if the customer wants 5 additional manuals, he or she will receive
5 for the entire order, order series, or project rather than 5 for each item as was sometimes the case with PSID-008 and PSID-034
(which are now inactive).
A transmittal letter will be furnished with PSID−565 and 566 listing all tag numbers (if used), serial numbers, and instruction manual
titles required for each tag or serial number. The letter is sorted by customer PO number, tag number, and serial number. The letter
is sent to the customer with the instruction manuals and it can be used to determine which manuals are required for each tag.
Instructions for use of PSID-065, PSID−465, PSID−565, and PSID−566.
From the customer’s requirements, determine if manuals are required. Also determine the ship-to address(es) for the manuals (the
address must include a street address—manuals cannot be sent to a P.O. Box).
Metric Nameplate
Order Entry Document Volume II
Enter on the Special Services screen (OE07) at an item level the appropriate PSNP code. The following note will appear
on the requisition.
************************************
Metric Nameplate Required
Pressure/Temp Only (See Below)
************************************
Enter an order level F30 note as follows, specifying the metric unit required.
F30: Nameplate Units to be in ___ (i.e., KPA, mm, Bar)
Select one of the following PSNP codes that describes your metric nameplate requirements.
Requirement Special Service Number List Price Extra
Pressure/temperature only PSNP-001
Pressure/temperature/travel only PSNP-002
Pressure/temperature/travel/size PSNP-003 No Extra
Displacer volume only PSNP-004
As specified in F30 note PSNP-099(1)
1. Requires item level F30 specifying what nameplate fields need to be changed.
APPROVAL OF LD CLAUSES
The appropriate Industry Manager in Marshalltown MUST approve ALL Liquidated Damage clauses. Any questions
regarding this policy should be directed to the appropriate Industry Manager.
Note: Since retention is not included in our Standard Terms & Conditions, the appropriate Fishert Industry Manager
must review the customer’s Term & Conditions as part of the quote submittal process. If the appropriate Fisher Industry
Manager does not review and negotiate Terms & Conditions, the Local Business Partner will be responsible for the
retention payment as well as other non−negotiated clauses in the customer’s terms.
Emerson will typically require a standby Letter of Credit or a Surety Bond in lieu of retenton.
Letter of Credit and Bond requests MUST allow for a lead time of four weeks minimum. Because of this, it is important that
the Local Business Partner recognize the requirements in the contract or request for quotation and follow this procedure
promptly to ensure due dates are met.
Note: If either Special Service code PSSC−008 or PSSC−009 is not included in the order, any retention claims will
be the responsibility of the sales office entering the order, even if the Bond or Letter of Credit were approved by
Emerson Automation Solutions.
Once this code is entered on your order, either Project Management or Global Inside Sales will request from the Local
Business Partner contact additional information regarding these requirements. Please have readily available:
D Copy of the Purchase Order
D PO Terms & Conditions
D Total Project $
D Legal entity name of beneficiary
D Mailing address for final document
Cover Sheet
The cover sheet will be the first page of the document transmitted to the customer. It will define to both parties what the
document contained includes as well as provides a status of the document. The Emerson or Local Business Partner (LBP)
assigned document controller will be required to add a cover sheet to each contractual documentation deliverable in line
with the project requirements. The Emerson preferred approach is to quote no cover sheet as standard.
The Emerson Standard Document cover sheet is automatically generated out of the DocPro documentation management
tool. The template can also be found in edocs by searching for the Emerson Standard “DocPro Cover Sheet” or by visiting
the Project Strategies Website at the following url:
http://mtndocs.mt.na.emersonprocess.com/ProjectStrategyWebsite/index.htm
Examples of the cover sheet should be provided to the customer in the final project bid as a best practice, and as part of
the Gate II meeting discussion.
Tier Options Non−Standard
(FF2 Drop Down) Description LBP Commission Price Per Tag
No Cover Sheet Standard − No cover sheet provided 0% Included as Standard
Standard Emerson Cover Sheet Standard − Emerson Cover Sheet (DocPro) 10% $34
Custom Cover Sheet Custom − Project Specific Cover Sheet 90% $114
Customer Inspection
Order Entry Document Volume II
CUSTOMER INSPECTIONS
Projects that require Inspections or Witness testing should quote one of the following options below. The Standard Emerson
approach should be to offer Inspection options to the customer that minimize delays to the manufacturing process. When
the customer insists on having the option to inspect, notification points can be used to provide the customer the opportunity
to witness key milestone tests of the valve assembly.
Notification Only definition: Emerson will notify the customer then wait for the specified duration to allow the customer to
inspect. Manufacture of the valves will continue regardless of whether the customer turns up for the inspection. If the test
is completed successfully to Fisher quality standards, Emerson will proceed with the work.
Selecting Notification Only inspection options help to minimize the impact on the order schedule impact.
Representative’s Responsibilities:
- Clearly understand the inspection requirements of the customer.
- Clearly communicate the customer’s requirements to the factory per the inspection levels shown during the order entry
process.
- Contact Global Industry Inside Sales or Project Management for any non-standard customer inspection requirements.
- Advise the factory the date the equipment must be ready for inspection in order to meet the customer requested
delivery date. To accomplish this, you must determine when the delivery to the customer’s job site is required, and
subtract the shipping time, 2 days for boxing, the time required for the customer to travel to the factory to complete
the inspection, and the required notification time prior to inspection and enter that date in the Requested Delivery Date
area of the order.
- Ensure that there is a name and phone number of the customer’s inspector clearly shown on the face of the order at
the time of order entry.
- If the name and phone number of the customer inspector is not known at the time of the order entry, a change order
needs to be entered with this information at least 2 weeks prior to the inspection date.
- If the customer inspection requirement is added after order entry, advise the new date the equipment is required to
be ready for inspection to support the customer delivery requirement.
Customer Responsibilities:
- Bring a copy of the certified and approved (if required) drawings for the equipment.
- Complete the inspection process within a reasonable period of time.
Factory Responsibilities:
- Acknowledge the delivery date for customer inspection orders as the ready for inspection date at the Emerson Process
Management factory.
- Complete the manufacture of the equipment on or before the acknowledged ready for inspection date.
- Notify the customer that the equipment is ready for inspection on or before the acknowledged ready for inspection
date. Please note that the customer inspector will only be contacted for inspection when the equipment is completed.
- Meet all of the inspection requirements of the representative order.
- If Notification Only inspection points are quoted the factory will notify either the Project Manager or LBP/Sales Office
to contact the customer to notify that the valves are ready for inspection and will be placed on hold for a set time to
allow the option for the customer inspect.
- It is the responsibility of the Project Manager or LBP/Sales Office to notify the factory to release the hold in line with
the quoted 2 or 10 notification working days period.
Photograph Inspection
Order Entry Document Volume II
Customer Inspection via Photographs must be specified at the time of order entry using the published PSCD codes
listed below and are valid for assemblies only. These are two photograph packages available. Only the photographs
listed below will be taken and sent to the Sales Office contact e−mail specified in the ACK notes on the order.
All orders for Photograph Inspections must include an ACK note with a Emerson Sales office, LBP, or Representative
e−mail address to send the pictures. Emerson manufacturing WILL NOT send photographs directly to
customers.
Emerson will allow for seven (7) days after the photographs are sent for the customer to either release the product
for shipment or communicate discrepancies. After seven days, Storage Charges will apply per the existing Storage
Charge Policy in OED II.
Once the order is entered, photographs may not be substituted for other forms of inspection such as in−person visual
inspection or witness points. If in−person inspection is waived in lieu of photographs, in−person inspection charges
still apply as well as photograph inspection and change order charges.
*The video link sent to the inspector/customer via the Emerson large file exchange is only active for 10 days. If the
inspector/customer doesn’t download the video within the allotted 10 days and link expires a $150 fee will be incurred for the link
to be resent.
(1)
Notification Only definition: Fisher will notify the customer then wait for the specified duration to allow the customer to inspect.
Manufacture of the valves will continue regardless of whether the customer turns up the inspection. If the test is completed
successfully to Fisher quality standards, Fisher will proceed with the work. Selecting Notification Only Inspection options help to
minimize the impact on the order schedule impact.
Inspector Responsibility
The valve will progress in manufacturing or be released to ship only after the inspector has reviewed and approved the
pre−recorded footage or live inspection footage. This approval can be made via email to the Customer Service
Representative/Internal Project Manager.
Customer approval is optional and not required if the notification only options are selected.
Emerson, standard policy is to ship product when ready, unless shipping restrictions have been agreed to and are noted
on the order such as, “Do Not Split Ship”, or a “Do Not Sip Before” date is provided at time of order entry. Orders are placed
with a requested ship date, which we make every attempt to meet, yet authorization to ship when ready is not always granted.
Not accepting the shipment, as agreed upon, adds significant costs to Emerson.
Emerson policy provides for storage charges to be applied to any order held at the factory due to customer imposed delays
for items that are built and in shipping or not providing inspector contact details for items in production. These customers
imposed delays include, but are not limited to, withholding shipping instructions or approvals, delaying customer
inspections, and not providing authorization to ship product as agreed upon.
Furthermore, change order charges may be applied to orders when “Do No Split Ship” or “Do Not Ship Before” date is added
after items are released to the factory.
These charges apply to customer delays of more than 10 working days. For customer inspection situations, storage charges
will be added if customer inspection and full shipping release has not been accomplished within 10 working days (or per
the contractual agreement) after the inspector has been notified. Delays caused by the customer will result in adjusting facto-
ry promise dates once item(s) have been ordered.
Notification will be provided to the customer when the delay starts. The cumulative total delay duration will be accumulated
per tag. Upon successful completion of the shipment, the final billing, including storage charges will be processed. Storage
charges for partial month will be assessed at their full month rate.
Note: A sample of the letter that can be sent to the customers explaining our Storage Charge Policy is available on FishWeb.
Please visit the Sales Administrative Manual located on the Global Industry Sales Home Page on FishWeb. Copy the letter
and use it during project negotiations.
Offering Tiers (FF2 Drop Down) Description LBP Commission Price Per Month
Order charge − for items stored or delayed
with a cumulative duration of more than 10
Storage or delays − up to 60 days 25% Consult Factory (1)
working (or per contractual agreement) days
and up to 60 days.
Order charge − for items stored or delayed
Storage or delays − more than 60 with a cumulative duration of more than 60 25% Consult Factory (2)
days days.
1. 2% item total per month − $350 minimum charge applied.
2. Subject to additional cancellation fees or additional extended storage fees − Consult WA Change Order Owner.
Validation Information
D Orders that contain customer order testing will be validated by the appropriate contact for the Test and Evaluation
lab responsible for the test.
Marshalltown − Andrew Kinser
Wuqing − Eric Yu
Cernay − Benoit Wagner
D The validation assures that a signed customer order test plan is in place, that the quoted lead time is achievable
based on the current lab schedule, and identifies any additional requirements for the valve assembly before and
after the test (for example: bare stem valve only, send parts before assembly, valve should be cleaned and
reassembled after testing, etc.).
Description Service Code Pricing
Customer Order Lab Testing SERX2−A32 TBD by each quotation
Note: For testing related to orders not already under project management, use project code 1100211 “Emerson Innovation
Center Testing.”
For a complete overview and description of this procedure, documentation and order process, consult the Sales
Administration Manual.
Emerson’s expectation is that shipment consolidation take place at the customer’s warehouse, forwarder, or third party
consolidation location. Emerson does not have warehouses on site to store built goods.
% Points Increase on
Split Ship Description Non−Standard Prices
Yes Unlimited Shipments(1) No Charge
One shipment per site, consolidation across sites or
No 4.053
any limitation on shipment number or grouping
1. Weekly consolidated shipments by plant allowed for Project Managed or export orders.
Credit Holds:
Most credit holds are resolved before product is ready to ship. However, if product has been built for 60 days past the
requested ship date and the credit hold has not been resolved, your order will be cancelled. Cancellation charges may apply.
The parts for your order will be returned to stock for use on other items. We will ask that you reenter your order once the
credit issue has been resolved. Please contact Customer Financial Services for credit hold questions.
Bill of Lading
Customers requirement for proof of shipment or delivery
Tier Option LBP Non−Standard
(FF2 Drop Down) Tier Options Commission Price
Emerson Standard − Bill of Lading Proof of Shipment from Emerson 0% $0
Proof of Delivery to INCO term Signed Proof of Delivery to INCO Term 0% $55
1. Included as standard.
Degreasing—General
Order Entry Document Volume II
DEGREASING REFERENCES
1. Fishert Valves Bulletin 59:045,
“Material Guidelines for Gaseous Oxygen Service”
2. FGS 8A11, Rev. 1988,
“Cleaning and Handling for Oxygen and Other Special Services”
PURPOSE:
The purpose of this procedure is to establish Emerson Automation Solutions guidelines for cleaning industrial−
process measurement and control equipment to be used by customers for oxygen and non-oxygen fluid services,
verifying this cleanliness, and ensuring that cleanliness of product will be maintained during transportation.
DEGREASING CLASSES:
THREE COMPANY IDENTIFICATION CLASSES are used to define the most commonly used grades of degreasing
for oxygen and non-oxygen services:
CLASS A NON-OXYGEN CLEANING: applies to product components which have surfaces that will contact fluid
other than pure oxygen. “Non-oxygen” fluids could include argon, liquid air, nitrogen, chlorine, etc.
CLASS AA CLEANING FOR OXYGEN SENSORING: applies to component parts used for sensoring and having
contact with pure liquid gaseous oxygen, or an oxygen-enriched fluid service. Specifically, this class addresses
degreasing and related factors that affect the system’s avoidance of ignition and fire. “Oxygen-Enriched Service”
applies to a fluid (gas or liquid) that contains more than 25 mol % oxygen.
CLASS AAA CLEANING FOR OXYGEN OPERATING MEDIUM: applies to components which control the flow
stream and have contact with pure liquid or gaseous oxygen, or an oxygen-enriched fluid service. Specifically, this
class addresses degreasing and related factors that affect the system’s avoidance of ignition and fire.
Degreasing−Miscellaneous
Order Entry Document Volume II
Body Size, NPS Degreasing Class Product Service Number Non−Standard Price Extra Each
A $896
1/4 thru 4 PSDG-028 PSDG-029
AAA(5) $1,537
A $1,217
6 PSDG-030 PSDG-031
AAA(5) $2,018
A $1,410
12x6, 12x8, 10x8 and 8 PSDG-032 PSDG-033
AAA(5) $2,242
A $1,704
10, 12, 14 PSDG-054 PSDG-055
AAA(5) $2,576
1. (FF2 Rule) Class A and AAA are not available on valves with ENVIRO-SEAL bellows seal bonnets.
2. (FF2 Rule) No degreasing available on CHP, D, DA, D2T, D3, D4, EAD, ED, EDR, EWD, EHD, EHS, EHT, HPAD, HPD or RSS.
3. (FF2 Rule) Class AAA is not available on GX valves with PTFE soft seat, WCC/LCC valve body material constructions, or GX valves with
bellows seal bonnets. Does not include the GX actuator. Reference Page 5B.3 for actuator degreasing options.
4. (FF2 Rule) Class AAA is available on Baumann valves, 24000 series, 51000, and the 81000 only. Class A and AAA are not available on
valves with the Baumann NOLEEK Bellows or extension style bonnets. Class AAA is not available on sanitary valves, the 24003 or the 26000.
5. (FF2 Rule) Class AAA cleaning requires a non standard seal ring for ET−C, EWT−C, and HPT−C cryogenic valves and ET/EWT Class VI with port
sizes 3-7/16 through 7-inch size. Special option and list price extra is not included in this product service number. Consult Global Industry Sales for
appropriate option and list price extra.
Below list prices provide for customer imposed stress relieving welded carbon steel items. Consult FMS 20B113 for heating
and cooling ramp rates, soak temperature, and soak time.
Size and Product Product Service Number List Price
NPS 1 & 2 — A & HP, NotchFlot DST PSHT−814 $467
NPS 1 through 2 — D, E, EW
PSHT−801 $322
(all end connections)
NPS 2−1/2 through 8 — E & EW
PSHT−801 $322
(all end connections)
NPS 2−1/2 through 8 — A, EH, HP, NotchFlo DST &
PSHT−802 $702
YD (all end connections)
NPS 10 through 24 — A, E, EH, EW, HP
PSHT−803 $1,754
(all end connections)
NPS 4 through 8 — V250, V260, V270, V280 PSHT−806 $1,403
NPS 10 through 24 — V250, V260, V270, V280 PSHT−807 $1,754
NPS 1 through 8 — CV500, V150, V150S, V200,
PSHT−808 $702
V300, V300S, V500
NPS 2 through 12 — A11, A31D, 8560, 8590
NPS 10 & 12 — CV500, V150, V150S, V200, V300, PSHT−809 $1,170
V300S
NPS 14 through 24 — A11, A31A, A31D, 8532, 8590 PSHT−816 $1,521
NPS 30 through 48 — A11 PSHT−817 $1,988
249B PSHT-812 $878
249BF (all standard sizes/end connections)(1) PSHTE-311 $878
249P
PSHTE−310 $936
Ratings 150 thru 600 lb. and equipment EN.(1)
249VS, 249BP, and 249P
PSHT−812 $878
(all standard sizes/end connections)
1−6 inlet — 6010 and 6013 PSHT−802 $702
8−24 inlet — 6010 and 6013 PSHT−806 $1,403
1−6 — 6011 and 6012 PSHT−808 $702
8−24 — 6011 and 6012 PSHT−809 $1,170
1−10 Whisper Diskt PSHT−802 $702
12− 24 Whisper Disk PSHT−806 $1,403
1. European sourcing only.
Note: This customer imposed requirement does not address compliance to NACE MR0175−2002 or −2003, NACE
MR0175/ISO 15156 or NACE MR0103, although it may be used in addition to other controls (options) that do address
those standards.
For additional information, see page 4 of PS sheet 59:020(A)
http://mtndocs.mt.na.emersonprocess.com/groups/public/documents/ps_sheets/ps_59.020(a).pdf
Oil−based vapor corrosion rust inhibitor sprayed inside body. Seal ends per WMP 10L1
Note: For this Product Service, the rust inhibitor will be sprayed inside the body, and the body will be sealed up with Masonite
covers, and tape according to WMP 10L1. If plywood covers are required, or if WMP 10L2 sealing is required, these Product
Services must be specified separately.
Valve Size, NPS Product Service Number Non−Standard Price Extra Per Unit
1/2 through 6 PSCD-160 $322
8 through 12 PSCD-240 $386
14 through 30 PSCD-241 $467
36 and larger PSCD-242 $527
Seal ends with low halogen tape and Masonite covers per WMP 10L2
Valve Size, NPS Product Service Number Non−Standard Price Extra Per Unit
1/2 through 6 PSCD-130 $164
8 through 12 PSCD-243 $216
14 through 30 PSCD-244 $252
36 and larger PSCD-245 $341
1. Enter on the ORDER ENTRY SCREEN (OE02) in the “PKG INSTR” field, Code “S”, this will call out on the
requisition that special packing is required.
2. Enter as a sub-component to Component “A” the following PSCD number that applies:
10% commission
ARAMCO Processing
Order process for ARAMCO orders apply to Control Valves for both General Service and Non−General Service in addition
to NACE and Non−NACE. The following instructions will guide you through the ordering process to ensure all applicable
ARAMCO requirements are fulfilled.
ARAMCO Processing is focused on direct ARAMCO orders. Adjustments may be necessary for additional requirements
added by EPC’s or OEM suppliers.
NACE
ARAMCO has specific requirements for NACE applications that will require that the Sales Office / LBP determine the correct
ARAMCO NACE PSCS option based on materials being supplied.
D You will need to review pressure boundary parts (i.e., body, bonnet, etc.) and major trim parts, plug, disk, cage, seat ring,
etc.
D Then select the correct ARAMCO NACE PSCS code based on the materials being supplied:
D Austenitic SST and Nickel based alloys (PSCS−012 or PSCS−022)
D Non−Austenitic SST & non−Nickel based alloys (PSCS−013 or PSCS−023)
D Non−Austenitic SST and non−Nickel based alloys require hardness testing and these requirements are included in
ARAMCO PSCS−013 and PSCS−023 options.
Common Austenitic Stainless Steel materials used in control valves: 300 series SST = Typical grades 316, 316L, 304, etc.
Nickel Alloy typical grades = Monel, Hastelloy C, Inconel, etc. (used for body and trims).
Common Non−Austenitic Stainless Steel materials used in control valves: 17−4 SST, 400 series SST (normally used for
trims)
Carbon Steel used for valve bodies and bonnets: WCC, LCC, etc., are non−Austenitic and require PSCS−013 or 023 options
when these materials are selected and NACE applies.
D If you have any questions if a material is or is not Austenitic or Nickel Alloy consult with a materials expert or contact your
local SD&S, SDSE or GIS contact to ensure the correct selection is made.
ARAMCO
Order Entry Document Volume II
ARAMCO Processing
PMI Low and High Carbon Stainless Steels:
Special Positive Material Identification (PMI) is required for low and high carbon stainless steels, (e.g., 316L, 316H, 347H,
etc.). ARAMCO requires PMI testing that measures the carbon level for low and high carbon stainless steels.
Measuring the carbon content is beyond our standard PMI testing process and requires test equipment capable of
measuring carbon content. This requirement applies to both trim and pressure boundary parts. Please consult factory for
price adder extra to meet this customer requirement.
Paint:
ARAMCO Processing assumes “manufactures standard paint” based on this statement found in ARAMCO − Material
System Specification 34−SAMSS−711 − Controls valves. When an RFQ includes additional specification specific to paint,
these documents should be reviewed and the appropriate paint system selected to comply with the additional customer
requirements.
Inspections:
For project that don’t have an assigned project manager (PM) or project administrator (PA), inspection coordination should
be organized by the manufacturing site customer service contact.
For project that have an assigned PM or PA assigned, they will assist in coordination of required inspection points.
North America requires a PM or PA to be assigned for Control Valves Non−General Service, contact the North America
Project Management Organization team for resource assignment.
Consists of:
D Standard Processing Level − 3: Control Valves (PSPL−300)
D Documentation of major weld repairs/procedures at Emerson Automation Solutions and foundry with RT of major weld repair and PMI
of Weld filler (PSCS−011)
D Minimum wall thickness verification of pressure boundary parts (Option A20)
D PMI of Pressure Boundary Parts (not required on carbon steel bodies) (Option G11)
D Assembled unpainted hydrostatic test (Option H1)
D Signature Series Testing (Option H2)
D Apply Cortec VpCI−369D oil based rust preventative to bare machined surfaces. Tape seal VpCI−126 barrier and wood or Masonite
end covers. For details, see WMP 10L1. Note: Rust preventative not applied to SST. (Option J1)
D Hold order for inspection − Inspector to inspect : (Option K1A)
D Final visual & dimensional
D Documentation
Ordering:
D Start with PSPL−300, add options A20, G11 as required, H1, H2, J1 (as required), K1A
D Select PSCS−011
D Must also order Signature Series 3 (PSCD−172) test with supporting P52 note “measure stem position at 10% intervals for both increas-
ing and decreasing travel.”
Note: PSPL−300 options outlined above and PSCD−172 are price adder in addition to PSCS−011)
Documentation included:
D Emerson Automation Solutions, Fishert Valve Division Manufacturer’s Certificate of Conformance (European type EN 10204 2.1)
D Certificate of Conformance to ASME/ASTM or other material specifications for pressure boundary parts (e.g., body, bonnet) and major
metal trim parts
D Chemical & Mechanical Test Reports (CMTR) of pressure boundary parts (European type EN 10204 3.1)
D PMI Test Reports of Pressure Boundary Parts (except carbon steel)
D Full documentation of Fisher and foundry for all major weld repairs to pressure boundary parts
D Assembly test results for hydrostatic shell test, seat leak test (valves), and operational test
D Manufacturer’s Data Report for ASME Section VIII equipment (e.g., volume tank), as applicable
D Wall thickness report
ARAMCO
Order Entry Document Volume II
ARAMCO: General Service Control Valve − NACE Processing
Test and Inspections per Form 175_340100 (rev 16 Nov. 2015) and Materials System Specification: Control Valves
34−SAMSS−711 (rev 4 Jan. 2012)
Consists of:
D Standard Processing Level − 3: Control Valves (PSPL−300)
D Documentation of major weld repairs/procedures at Emerson Automation Solutions and foundry with RT of major weld repair and PMI
of Weld filler (PSCS−012/PSCS−013)
D Certificate of Conformance to NACE MR0175 / ISO 15156 (Option A3)
D Certified Material Test Report for plug/disk/ball, seat ring (sliding stem valve), stem/shaft, and cage (not available on WhisperFlo cages)
(Option A9)
D Certified Material Test Report for pressure bolting (Option A11)
D Minimum wall thickness verification of pressure boundary parts (Option A20)
D Hardness test required of pressure boundary and major metal trim parts for Non−austenitic SST or Non−Nickel alloy constructions
meeting NACE MR0175 / ISO 15156 (PSCS−013) (Refer Note 1)
D PMI pressure boundary parts (not required on carbon steel bodies) (Option G11)
D Assembled unpainted hydrostatic test (Option H1)
D Signature Series Testing (Option H2)
D Apply Cortec VpCI−369D oil based rust preventative to bare machined surfaces. Tape seal VpCI−126 barrier and wood or Masonite
end covers. For details, see WMP 10L1. Note: Rust preventative not applied to SST. (Option J1)
D Hold order for inspection − Inspector to inspect : (Option K1A)
D Final visual & dimensional
D Documentation
Ordering:
D Start with PSPL−300, add options A3, A9, A11, A20, G11 as required, H1, H2, J1 (as required), K1A
D PSCS−012 or PSCS−013
D Must also order Signature Series 3 (PSCD−172) test with supporting P52 note “measure stem position at 10% intervals for both increas-
ing and decreasing travel.”
Note: PSPL−300 options outlined above and PSCD−172 are price adder in addition to PSCS−012 or PSCS−013)
Documentation included:
D Emerson Automation Solutions, Fishert Valve Division Manufacturer’s Certificate of Conformance (European type EN 10204 2.1)
D Certificate of Conformance to ASME/ASTM or other material specifications for pressure boundary parts (e.g., body, bonnet) and major
metal trim parts
D Certificate of Conformance to NACE MR0175 / ISO 15156
D Chemical & Mechanical Test Reports (CMTR) of pressure boundary parts and trim parts (European type EN 10204 3.1)
D Certified Material Test Report for pressure bolting
D Hardness test results for pressure boundary and major metal trim parts only where applicable (Refer Note 1)
D PMI Test Reports of Pressure Boundary Parts (except carbon steel)
D Full documentation of Fisher and foundry major weld repairs to pressure boundary parts
D Assembly test results for hydrostatic shell test, seat leak test (valves), and operational test
D Manufacturer’s Data Report for ASME Section VIII equipment (e.g., volume tank), as applicable
D Wall thickness report
Note 1: Hardness test will be performed on carbon steel bodies and major trim parts; is not applicable to Austenitic stainless steel
or nickel based alloys (both pressure boundary and trim parts) that meet NACE MR0175 / ISO 15156 requirements.
ARAMCO
Order Entry Document Volume II
ARAMCO: Non−General Service Control Valve Processing
Test and Inspections per Form 175_340150 (rev 16 Nov. 2015) and Materials System Specification: Control Valves
34−SAMSS−711 (rev 4 Jan. 2012)
Consists of:
D NDE per Processing Level 5 − PL5 NDE − Critical Area Coverage ASME B16.34 Acceptance Criteria (PL5 option selected based on
product type, size and pressure class)
D Minimum wall thickness verification of pressure boundary parts (Option A20)
D Hold point for approval of major weld repairs/procedures at Emerson Automation Solutions and foundry with RT of major weld repair
and PMI of Weld filler (PSCS−021)
D PMI of Pressure Boundary Parts (not required on carbon steel bodies) (Option G11)
D Assembled unpainted hydrostatic test (Option H1)
D Signature Series Testing (Option H2)
D Apply Cortec VpCI−369D oil based rust preventative to bare machined surfaces. Tape seal VpCI−126 barrier and wood or Masonite
end covers. For details, see WMP 10L1. Note: Rust preventative not applied to SST. (Option J1)
D Subject to ARAMCO Visual set−out dimensional inspection (PSCS−021)
D Hold Order for Inspection − Inspector to inspect : (Option K1A)
D Final visual & dimensional
D Documentation
D Hold Order for Inspection − Inspector to inspect: (Option K3A)
D Boxing and marking for shipment (crating)
D Hold Order for Inspection − Inspector to Witness: (Option K4A). Assembled hydrostatic test. Also select option H1 or H3.
D Hold Order for Inspection − Inspector to witness: (Option K6A). PMI test. Also select option and price extra for Option G10, G11, G12,
or G13.
D Hold Order for Inspection − Inspector to witness: (Option K7A). Inspector to witness seat leak test.
D Hold order for Inspection − Inspector to witness: (Option K8A). Inspector to witness operational test.
Ordering:
D Start with PSPL−500, add options A20, G11 as required, H1, H2, J1 (as required), K1A K3A, K4A, K6A (as required), K7A, K8A
D Select PSCS−021
D Must also order Signature Series 3 (PSCD−172) test with supporting P52 note “measure stem position at 10% intervals for both
increasing and decreasing travel.”
Note: PSPL−500 options outlined above and PSCD−172 are price adder in addition to PSCS−021)
Documentation included:
D Emerson Automation Solutions, Fishert Valve Division Manufacturer’s Certificate of Conformance (European type EN 10204 2.1)
D Certificate of Conformance to ASME/ASTM or other material specifications for pressure boundary parts (e.g., body, bonnet) and major
metal trim parts
D Chemical & Mechanical Test Reports (CMTR) of pressure boundary parts (European type EN 10204 3.1)
D PMI Test Reports of pressure boundary Parts (except carbon steel)
D NDE test reports per PL5 radiographic examination
D Full documentation of Fisher and foundry for all major weld repairs to pressure boundary parts
D Assembly test results for hydrostatic shell test, seat leak test (valves), and operational test
D Manufacturer’s Data Report for ASME Section VIII equipment (e.g., volume tank), as applicable
D Wall thickness report
Note 1: Hardness test will be performed on carbon steel bodies and major trim parts; is not applicable to Austenitic stainless steel
or nickel based alloys (both pressure boundary and trim parts) that meet NACE MR0175 / ISO 15156 requirements.
Pricing
Description Code Non−Standard Price/Unit
Contractor Customer Special Processing with the
PSCS-003 N/C
Contractor’s inspection requirements
10% commission
Special Handling
Order Entry Document Volume II
Product service note—enter on the OE04 screen as a subcomponent to the product assembly
PSCG-251 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $105 non−standard / item
Message: [assemble per “FMP x22”]
10% Commission
Customer Inspector Witness of Fugitive Emissions Testing, ISO 15848/2 or Shell MESC
SPE 77/312
For assemblies shipping from Asia or Europe.
PSIS-120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . List price extra per unit / valve − Consult Factory
Cryogenic Testing
Seat Leak Tests at Low or Cryogenic Temperatures for Fisher Rotary Style Valves
Test procedure defined in FGS 4L19.
Select the appropriate test below. Must specify leakage class A, B, C, D or E (consult GIS).
Description PSIS $ Non−Std/Unit/Component
Cryo−1 Test (−320_F / −196_C Test)(1) PSIS−114
Consult Factory
Cryo−2 Test (−50_F / −46_C Test)(1)(2) PSIS−115
1. Must specify Leakage Class A, B, or C.
2. Not available in North American.
Seat Leak Tests at Low or Cryogenic Temperatures for Fisher Sliding Stem Valves
Test procedure defined in FGS 4L7.
Select the appropriate test below. Must specify leakage class A, B, C (consult GIS).
From FGS 4L7 Table 1: Required Ambient Temperature Leak Classes for Sliding Stem Control Valves Rated for Cryogenic
Class A, B, or C Performance.
Valve Trim Design Type of Construction Cryogenic Class Rating Required Ambient Leak Class per FGS 4L5
ET−C(1) A, B V (air only)
EWT−C(1) A, B V (air only)
Large ET−C(1) A, B V (air only)
Large EWT−C(1) A, B V (air only)
Soft Metal−to−Metal Seat
EZ−C(1) A, B VI
GX C IV
HPT−C(2) C IV or V (air only)
HPS−C(2) C IV or V (air only)
1. These specific constructions are available with Cryogenic Class A or Cryogenic Class B ratings.
2. These specific constructions are available with Cryogenic Class C ratings.
Factory Acceptance Testing (FAT) of Critical Valves (Typically Anti Surge Applications)
Performance testing of critical valves as defined in PS Sheet 59.047(A) for compliance with FGS 4L11. Before accepting
this, the requirements and the selection of actuator and accessories MUST be checked by SDSE/GIS to ensure the
specification will be met. Any differences to these MUST be accepted by SDSE/GIS BEFORE quotation.
Class A Testing and acceptance of all requirements shown on Table 1 of PS Sheet 59.047(A).
Advanced FAT PSIS-103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . List price per valve $10,420
Basic FAT PSIS-104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . List price per valve $3,473
Class B Testing to meet stroking time requirements of PS Sheet 59.047(A) Table 1 requirements 1, 2 and 3.
Requirements 4 to 11 will be tested and results recorded and supplied to the customer.
Advanced FAT PSIS-105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . List price per valve $6,947
Basic FAT PSIS-106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . List price per valve $2,426
Class C Only Stroking times will be tested against customer requirements. No other testing performance testing
will be made.
Advanced FAT PSIS-107 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . List price per valve $1,041
Basic FAT PSIS-108 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . List price per valve $409
Note: One of these PSIS codes must be entered for any Anti Surge valve or other valve with stroking speed
requirements.
Performance testing of rotary critical valves as defined by FGS 4L27. Before accepting this, the requirements and the
selection of valve, actuator and accessories MUST be checked by GIS to ensure the specification will be met. Any
differences to these MUST be accepted by GIS BEFORE quotation.
Class B Testing and acceptance of all requirements shown in FGS 4L27 section 6.1.4a.
PSIS-136 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . List price per valve $1,041
Class C Only stroking times will be tested against customer requirements. No other testing performance will be
made.
PSIS-137 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . List price per valve $409
Note: One of these PSIS codes must be entered for any Fisher Digital Isolation Solution.
IEC 61508
Order Entry Document Volume II
IEC 61508
Order Entry Document Volume II
IEC 61508 SIL Capable Valve and Actuator Products (Continued)
Product Service
Valve Series Body Style/Trim Size NPS & Class (DN & PN) List Price
Number
8580 2−12, CL150−300 DN50−300, PN10−40
8590 3−24, CL600
High−Performance
Butterfly Valves 2−12, CL150−300
Control−Disk Valve
3−24, CL600 DN50−300, PN10−40
Design ET, EWT, ETR, and EAT With PTFE Seat Construction
Class V air test is furnished.
Optional ANSI/FCI 70-2 Class V water test
Product Service Number PSLK-013............................................................................................ List Price $514
Note: Class V water test requires that service shutoff drop must be specified in F50 note field at time of order
entry.
Note: Class V seat leak water test is not available for oxygen, cryogenic or any valves cleaned per FGS 8A11.
Any disassembly to dry and/or re-clean the valve would invalidate the seat leak test.
Reference PS Sheet 59.1:004(C) for optional seat leakage test for oxygen cleaned valves.
Note: (FF2 Rule) Class V seat leak water test is not available for Trim Cartridge.
For Design Yarway AT−18, Yarway AT−28, Yarway AT−38, Yarway AT−48, Yarway AT−37, Yarway AT−47, and
Yarway Series 4300 TempLow
Class V seat leak test is furnished for these products.
Optional ANSI/FCI 70-2 Class V Water Test
Product Service Number PSLK-015............................................................................................ List Price $514
Note: Class V test requires that service shutoff drop must be specified in F50 note field at time of order
entry.
REFERENCE: PS Sheet 59.1:004:(A)
LIST PRICE EXTRAS for optional leak tests for current published Fisher valves available with optional leak classes.
Leak classes are in accordance with ANSI/FCI 70-2.
Note: These leak tests may also require additional options and list price extras to valve body construction specified.
Refer to product bulletin or PS sheet 59.1:004(A) for construction details and to OED I and OED II for pricing
extras if required.
Product List Price Extra Product List Price Extra Product List Price Extra
Valve Size,
NPS Service Class III Over Service Class V Air Test Service Class V Water Test
Number Class II Number Over Class IV Number Over Class IV
1 - 1-1/2 N/A N/A PSLK-031 $220
PSLK-015 $514
2 - 2-1/2 PSLK-032 $220
PSLK-016 $924
3-4 PSLK-033 $383
PSLK−036(1) $1,288
PSLK-014 $514 PSLK-017 $467
6 - 10 PSLK-034 $467
PSLK−037(1) $1,579
PSLK-018 $673
12-16 PSLK-035 $673
PSLK−038(1) CF
1. For use with WhisperFlo trim construction.
Note: Current standards treat Class V water and air test as equivalent. See PS Sheet 59.1:004(A).
Note: All Class V orders must include service shutoff drop in F50 note at time of order entry.
LIST PRICE EXTRAS for optional leak tests for valves cleaned per FGS 8A11 (A or AAA).
Note: These leak test may also require additional options and list price extras to valve body construction specified.
Refer to product bulletin or PS Sheet 59.1:004(A) or (C) for construction details and to OED I and OED II
for pricing extras if required.
Note: Class V seat leak water test is not available for oxygen, cryogenic or any valves cleaned per FGS 8A11. Any
disassembly to dry and/or re-clean the valve would invalidate the seat leak test. Reference PS Sheet
59.1:004(C) for optional seat leakage tests for oxygen cleaned valves.
Note: Nitrogen will be used as the test medium instead of air on oxygen cleaned valves.
Fabrication weld NDE options PSLP−003, PSMT−004, & PSRT−005 have been replaced by
Processing Level options B7 & G7. See Processing Level section of OEDII for details.
Specialty Certification
Order Entry Document Volume II
NON−STANDARD PRICE
1. Additional miscellaneous Specialty Certifications not included with Processing Levels:
Note: for any of the Certifications below, Processing Level 2 or higher must be entered along with these additional PSCD codes (these
are additional statements that are added to Fisher’s standard Manufacturer’s Certification Form).
A. Hardness Test Cert PL − (Stress Relieve and Hardness Certification) …………….................... $93 per item
PRODUCT SERVICE NO. PSCD−082
“Pressure boundary parts have been stress relieved and the hardness does not exceed 22Rc.”
(Requires stress relieving of carbon steel castings. Price extra for stress relieving not included.)
B. Shelf Life Cert PL − (Shelf Life Statement for Equipment) ......................................................... $93 per item
PRODUCT SERVICE NO. PSCD-062
“Expiration date of shelf life on elastomeric parts is (date)”
(The date will be per the PSCD−062 listing in FGS 8A31, Table 2)
C. Low Chlorides Cert PL − (Certification to less than 200 ppm chlorides) ....................................... $84 per item
PRODUCT SERVICE NO. PSCD-063
“Material contains less than 200 ppm chlorides.”
D. Mercury Free Cert PL − (Mercury Free Certification) .................................................................... $93 per item
PRODUCT SERVICE NO. PSCD-073
“All parts mercury-free except for trace elements.”
E. Residual Risk Assessment PL − (Residual Risk Assessment) ..................................................... $58 per item
PRODUCT SERVICE NO. PSCD-252
Note: This document is to comply with EC Machinery Directive (2006/42/EC), Annex VII B Requirement when
the valve is considered Partially Completed Machinery (PCM). Processing Level Option A12 (PSPM−214) must
also be specified (EC Declaration of Incorporation).
2. Customer Cert PL − (Customer’s Certificate of Compliance or Conformance). .................. ………..$176 per Customer
Form
PRODUCT SERVICE NO. PSCD-064
The customer’s certification form must be sent in at time of order entry.
3. EX−IM Bank Analysis − (EX−IM Bank Analysis Required)................................................................... …$211 per item
PRODUCT SERVICE NO. PSIS-046
4. Fisher Manufacturing Cert PL
(Emerson Automation Solutions, Fisher Valve Division Manufacturer’s Certification Form)…………...…$123 per item
PRODUCT SERVICE NO. PSCD-081. Note: Must also specify PSID−084, documents on Website (no charge).
For use with stand alone instruments or actuators only.
5. Origin Cert PL − (Certification of Country of Origin) ............................................................................... $24 per item
PRODUCT SERVICE NO. PSCD-072
Note: Enter either K50 (domestic) or K60 (export) note specifying chamberized or nonchamberized certification or origin.
6. Lloyd’s Register Marine Approval −
(Lloyd’s Register Marine Type Approval Certificate for Digital Valve Controller DVC6000 or DVC6200 Series)
........................................................................................................................................................ $643 per unit
PRODUCT SERVICE NO. PSCD-253
NOTES:
1. If additional certification or quality assurance procedures are necessary, please contact appropriate Global Industry Inside Sales or
Project Management to determine if any charges apply.
2. Contact the appropriate Global Industry Sales Manager for Special Project Pricing.
3. If certification is required on shipped equipment, contact Global Industry Inside Sales for special ordering and pricing.
Notes:
1. If additional certification or quality assurance procedures are necessary, please contact appropriate Emerson
Automation Solutions factory to determine if any charges apply.
2. Contact Country Sales Manager for Special Project Pricing.
3. If certification is required on shipped equipment, contact the appropriate Emerson Automation Solutions Factory for
special ordering and pricing.
AIFTA: ASEAN-INDIA Free Trade Agreement, Analysis of Compliance with FTA Required………….……..$176 per item
Product Service No. PSIS−149
0% commission
The European Pressure Equipment Directive 2014/68/EU (PED) requires pressure equipment destined for certain countries
in Europe to be marked with a “CE Mark” and that the equipment meets all aspects of the directive. PED is one of a number
of EC Directives aimed at achieving free trade within Europe. Previously, these countries had their own standards and
requirements for products traded in their country. This Directive was written to remove technical trade barriers by
harmonizing the national laws within Europe. The PED applies to the design, manufacture, and conformity assessment of
pressure equipment and pressure assemblies. All equipment covered by this Directive must comply with essential safety
requirements, which will then meet the equivalent national laws of all member countries.
The PED categorizes equipment based upon the relative safety hazard represented by the application. These “Categories”
are dependent upon the type of fluid, valve size (or volume), and design pressure (class). The process of categorization
is somewhat complex, so the Valve Division has assumed the maximum design Category for each applicable product and
size, based upon the most hazardous fluid.
The Categories and applicable products are listed below, along with the associated PSCD code to ensure compliance with
the PED law.
Please note that SEP (Sound Engineering Practice) applies to pressure equipment that is not subject to PED compliance,
but must be designed and manufactured in accordance with existing “sound engineering practice”. Consequently, SEP
equipment cannot be CE marked based strictly upon PED requirements. Instead, these products will require a “Declaration
of SEP” to properly identify them and to minimize complications when exported to one of the applicable European countries.
(It should be noted, however, that there are other European directives which may apply to SEP equipment and these
components may exhibit the CE mark based upon compliance with these other directives. For example, DVC5010’s are
classified as SEP by the PED, but they bear a CE mark because they comply with the ATEX and Electromagnetic
Compatibility directives.)
Procedure
Order Processing Systems require an indicator for domestic or export shipment (Federal Export Regulations). If the order
is destined for one of the European Union countries which require adherence to the PED (refer to OED II, 5D.8), it must be
screened for the applicable directive(s) and process accordingly.
Please refer to OED II, 5D.8 for a listing of the countries which require adherence to the PED.
Please refer to the Product Matrix for PED compliance on FishWeb [Alphabetical/P/Pressure Equipment Directive (Fisher
Division)/Product Matrix]. Follow the steps to determine the following: PED applicability, material approval, manufacturing
site options, and the appropriate Product Service Code indicated (see next page).
Note: Some of the PSCD’s require a minimum of Processing Level 3 in addition to the applicable PED requirements(s). Also,
if the component is Category II or Category III, and involves fabrication welding (such as an extension bonnet, or reducers),
the order will require CSP Processing in addition to the PSCD’s (due to requirements related to weld procedure and
personnel approvals).
Also, see OED II, Section 6 if/when Processing Levels are required.
Procedure
Similar to the Pressure Equipment Directive, ATEX only applies to certain countries. Please refer to the Sales
Administrative Manual, located on the Sales Development and Support Homepage on FishWeb for a listing of the
countries which require adherence to the ATEX Directive.
ATEX Directive compliance is slightly different from the Pressure Equipment Directive. Whereas PED is mandatory,
depending upon the service conditions (pressure, size/volume, fluid), ATEX compliance is dependent upon the
customer’s application (see above “zone” classifications). Thus, we must rely upon the customer’s order to invoke
ATEX compliance in some manner (such as: ATEX; Zone 0, 1, or 2; 2014/34/EU). In some cases, the customer may
order one of the aforementioned instrument with special ATEX approved FS/Option and nameplate. This indicates
that they are interested in ATEX compliance and the order should be processed accordingly.
We have developed special Product Service Codes to allow us to properly process ATEX orders to insure correct
product marking and certification. Select the appropriate PSIS code as shown in the following table whenever the
order is identified as requiring ATEX compliance.
1) If CE marked for ATEX, then must also be processed for PED. See 5D.3.
Category II, III for 785C Series:
PSCD-306 No Charge
Includes PED and ATEX certification CE marking, Safe Use Guide.
Fishert Instruments:
See OED I for special Construction which will include CE ATEX Marking, and Safety Instructions (which includes EU
Declaration of Conformity).
In some cases, customers may order a Fisher instrument (or buyout accessory) with ATEX construction strictly because it
provides another type of safety protection unrelated to possible use in an explosive atmosphere. An example of this is
“Intrinsically Safe” wiring requirement and approvals. In these cases, the Representatives must confirm that the requirement
for ATEX (”explosive atmosphere”) is not applicable and the above PSIS codes should not be applied to the order. To clarify
this situation in a consistent and systematic way, the following code must be applied instead to document non−applicability:
PSIS−031 (no charge will apply).
Buyout Accessories:
Buyout accessories may be subject to ATEX and various other European Directives (Low Voltage, Electromagnetic
Compatibility, etc.). It is important that these components comply with, and are CE marked in accordance with, the applicable
directive(s). See OED II, Section 4 for applicability and instructions.
Final responsibility for selecting a European Directive compliant (CE marked) buyout component is incumbent upon the
Customer.
15% Commission
Contact Global Industry Inside Sales if you have any questions.
Effective: 1 October 2020
All Fisher trademarks are owned by Fisher Controls International LLC, a member of the Emerson Automation Solutions business unit of Emerson Electric Co.
Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of
their respective owners. 5D.5
© 2002, 2020 Fisher Controls International LLC. All Rights Reserved.
Emerson Confidential -- Internal Use Only
OED I/II not maintained as of October 2021 - use for REFERENCE only. Refer to FF2 for current pricing.
For OED prices not available in FF2 only: apply a 9% markup beginning 2/22 or a 5% markup prior to 2/22.
European Union Countries and Directives
Order Entry Document Volume II
Effective August 1, 2008, it will be assumed that all member states have adopted all the above Directives. These
current European member states include:
Austria Greece Norway
Belgium Hungary Poland
Bulgaria Iceland Portugal
Croatia Ireland Romania
Cyprus Italy Slovakia
Czech Republic Latvia Slovenia
Denmark Liechtenstein Spain
Estonia Lithuania Sweden
Finland Luxembourg Switzerland
France Malta Turkey
Germany Netherlands United Kingdom
The above information is required for properly processing orders per the following OED II price pages:
D OED II, Section 4 − European CE Mark and Australian C−Tick Mark (for Buyout Equipment)
D OED II, Section 5 − Pressure Equipment Directive for Valve Division Products Sourced from N. American sites
D OED II, Section 5 − ATEX Directive for Valve Division Products Sourced from N. American sites
D OED II, Section 10 − European Directives
D OED II, Section 10 − ATEX Directive for Valve Division Products Sourced from European sites
To permit shipment into the CU, it was necessary to obtain the necessary approvals for our product types. Design files were
coordinated via a third party agency, manufacturing/inspection assessments were completed, and approval was granted
by the appropriate Russian authority. These approvals (certifications) permit us to process orders in accordance with the
applicable regulation(s), issue our certification to CU TR, and apply a special mark to signify compliance: “EAC.” Additional
marking will be applied as defined by each regulation.
Procedure
Ordering processing systems require an indicator for domestic or export shipment (US Federal Export Regulations). If the
order is destined to one of the Customs Union countries, it must be screened for the applicable regulation and processed
accordingly.
Proper order processing is important to insure compliance with Customs Union requirements. If order is destined for Russia,
Kazakhstan, Belarus, or Armenia refer to CU TR Product Matrix on FishWeb (Alphabetical/C/CU TR Customs Union
Technical Regulations/Product Matrix) and apply the appropriate Product Service Code(s) to insure order processing,
certification, and marking.
Note: Only the following manufacturing locations are CU TR authorized (Lifecycle Service operations are not included in
this approval).
America’s Europe Middle East − Africa Asia Pacific
Singapore
Marshalltown Cernay Nilai
Sherman Szekesfehervar Dubai Sakura
Sorocaba Chelyabinsk Bao−an
Wuqing
Chennai
Includes EN 10204 3.1 (with statement of CU TR compliance), EAC/EX tag, CMTR’s for Main
Pressure Boundary Parts (valve or Leveltrol only). Russian Language Instruction Manual,
Safety Instructions (Incl. Russian language), Metric nameplate (Russian language).
CU TR 012/2011 Explosive Atmosphere Safety II Gb c T*X and III Db c T*X for D2T, D3
Valves & Actuator:
Note: Processing Level of 1 must be selected with this option.
Includes applicable CUTR certifications (D2T: 010/2011 Mach Safety, 012/2011 Exp At. D3:
PSIS-150 $412
010/2011 Mach Safety, 012/2011 Exp At, and 032/2013 Pressure), EAC tag, Russian
Language Instruction Manual, Safety Instructions (Incl. Russian language), Metric nameplate
(Russian language).
CU TR 012/2011 Explosive Atmosphere Safety II Gb c T*X and III Db c T*X for 685, 685SE,
685SR Actuators (includes CU TR 010/2011):
Note: Minimum Processing Level of 3 must be selected with this option (except bare−stem
actuators only require Minimum Processing Level of 2).
PSCD-304 $412
Includes EN 10204 3.1 (with statement of CU TR compliance), EAC/EX tag, CMTR’s for Main
Pressure Boundary Parts (valve only) Russian Language Instruction Manual, Safety
Instructions (Incl. Russian language), Metric nameplate (Russian language).
CU TR 012/2011 (Expl Atmos), and 010/2011 (Machine Safety) for 785C Series:
Includes Russian Certification and units marked EAC and EAC Ex as applicable (with PSCD-305 No Charge
statement of CUTR compliance).
Fishert Instruments:
See OED I for special constructions which will include CU TR Marking, and Safety
Instructions.
In some cases, customers may order a Fisher instrument (or buyout accessory) with CU TR
Expl. Safety strictly because it provides another type of safety protection unrelated to possible
use in an explosive atmosphere. An example of this is “Intrinsically Safe” wiring requirement PSIS-113 N/C
and approvals. In these cases, the LBP must confirm that the requirement for ”explosive
atmosphere” is not applicable and PSIS−111 should not be applied to the order. To clarify
this situation in a consistent and systematic way, the following code must be applied instead
to document non−applicability. This code can ONLY be used if the valve assembly is not
going into a hazardous area (explosive atmosphere).
Buyout Accessories:
See OED II, Section 4 for applicable Product Service Codes.
Note: Electrical and Non−Electrical Fisher Instruments must be ordered with special CU TR approved constructions and marking (See OED I).
15% Commission
Parts Certification/Packaging
Order Entry Document Volume II
When ordering, specify certificates by name and form number.
...................................................................... NON−STANDARD EXTRAS
1. Emerson Automation Solutions, Fisher Valve Division Manufacturer’s Certification for Parts ..... $85 per item
PRODUCT SERVICE NO. PSCD-066
(Formerly called Certificate of Conformance
or Certificate of Compliance)
See Sample Form 3426
4. Shelf Life Statement for Elastomeric Parts ....................................................................................... $141 per order
PRODUCT SERVICE NO. PSCD-069
Must enter R05 note indicating PSCD-069 is at order level. “Expiration date of shelf life of elastomeric parts is
date.” (The date will be per the PSCD−069 listing in FGS 8A31, Table 2) see QA Form 3426.
5. Special Packaging & Labeling ........................................................................................................... $282 per item
PRODUCT SERVICE NO. PSCD-131
Packaging and labeling for elastomer parts, (O-rings, diaphragms, etc.) for nuclear plant orders.
Package in ultra-violet resistant resealable plastic bags.
- Qty. (10) per bag for dia. up to 0.75 inch
- Qty. (5) per bag for dia. over 0.75 up to 1.57 inch
- Qty. (1) per bag for dia. over 1.57 inch
Special labeling to include cure date
Also includes material certification with extended life statement, provided the storage guidelines described
FGS 8A31 are followed. “Expiration date of shelf life of elastomeric parts is date.” (The date will be per the
PSCD−131 listing in FGS 8A31, Table 2) see QA Form 3426.
If additional certification or quality assurance procedures are necessary, please contact Global Industry Inside Sales to
determine if any charges apply.
Contact the appropriate Global Industry Sales for Special Project Pricing.
Available commission 10%.
For sample forms, contact Global Industry Inside Sales.
This test is a verification that the alloy metal parts are the alloy required per the order. PMI cannot verify carbon
steel (WCB, WCC, LCB, LCC, SA-105, SA-106, SA-181, SA-182, F2, SA-350 or other materials where the
Chromium, Nickel, Molybdenum, etc. are less than 1.0%). The alloy analyzer does not detect Carbon or Silicon
which precludes distinguishing between 316 and 316L or 410 and 416 stainless steel grades.
Form 2246.
Example: Item #1, Qty. 8, $184 + (8 x 40) = $510 total for Item 1
Item #2, Qty. 2, $184 + (2 x 40) = $266 total for Item 2
9. Customer Certificate of Compliance or Conformance ...................................... $169 per form
PRODUCT SERVICE NO. PSCD-064
The customer’s certification form must be sent in at time of order entry.
DOES NOT APPLY TO NUCLEAR ORDERS.
10. Chemical and Mechanical Reports for Parts (only) ........................................ $113 per item
PRODUCT SERVICE NO. PSCD-136
Chemical and test reports only available on parts where CMTRs are available (like: plug, seat ring, cages, stems,
guide post retainer, seal protector/flow ring. CMTRs are not available on WhisperFlo cages, D4, or Trim
Cartridge.)
NOTE: May require process coded part numbers. Contact Parts Department before using.
11. Hydrostatic Test and certificate for sliding stem or rotary valve body ......................... $307 per unit
PRODUCT SERVICE NO. PSCD-031
If additional certification or quality assurance procedures are necessary, please contact Global Industry Inside Sales to
determine if any charges apply.
Contact the appropriate Global Industry Sales for Special Project Pricing.
Available commission 10%.
For sample forms, contact Global Industry Inside Sales.
ENVIRO−SEAL Optional Extended Warranty – Not To Be Used in High Cycle Applications (PSA)
ENVIRO−SEAL Packing 5 Year Warranty for “Low−E” fugitive emissions requirements only for use with NA customers who
have a Department of Justice consent decree.
Select the appropriate published ENVIRO−SEAL packing option/attribute and its associated price extra. Then select the
PS code below and its price extra to provide a serialized warranty certificate shipped with the new valve.
The following note will be included on the serial card and order documentation.
*** “Low−E” packing solution with 5−year warranty in Non-High Cycle Applications ***
The complete terms and conditions of the warranty will be provided with the certificate.
The following verbiage is an excerpt from warranty:
The packing is warranted for five (5) years from the date of shipment of shipment or completion of the Fisher
Certified repair (“Packing Warranty Period“), as applicable. If, during Packing Warranty Period, Buyer
documents tests results in excess of 100ppm per EPA Method 21 after making standard adjustments per the
applicable instruction manual and notifies Seller thereof in writing, Seller shall provide new, replacement Packing
rings to Buyer. All replacement Packing rings necessitated by inadequate maintenance; normal wear and usage;
use beyond Seller’s published pressure and/or temperature limits for 100ppm service; unsuitable power sources
or environmental conditions; accident; misuse; improper installation, including without limitation, installation by
a party other than Seller or Seller’s authorized service representative (“Authorized Packing Installer”);
modification; non−Fisher Certified repair, use of unauthorized replacement parts; storage; handling; or any other
cause not the fault of Seller are not covered by this limited warranty, and shall be at Buyer’s expense.“
New packing rings will be provided per this agreement. To renew the 5−year warranty the new packing rings must be installed
by an authorized Fisher Service provider.
Warranty applies to all ENVIRO−SEAL packing options for all sliding stem and rotary control valves only within published
100ppm application limits.
Non−Standard
Special Service Number Type Price Per Unit
PSCD−860 “Low−E” solution, 5−year ENVIRO−SEAL packing warranty $567
No Commission
Extra Documents
Order Entry Document Volume II
At the representatives’ request, Emerson Automation Solutions will send extra document copies to the customer.
Extra ACKNOWLEDGMENT copies:
PSID-002 (Special Service Code) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No Extra
Extra BILL OF LADING copies:
Domestic - Enter Order Level K50 Note listing Bill of Lading requirements . . . . . . . . . . . . . . . . . . . . . . . . . No Extra
Exports - Enter Order Level K60 Note listing Bill of Lading requirements . . . . . . . . . . . . . . . . . . . . . . . . . No Extra
Extra INVOICE copies:
PSID-001 (Special Service Code) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No Extra
Extra PACKING LIST copies:
Domestic - Enter Order Level K50 Note listing Packing List requirements . . . . . . . . . . . . . . . . . . . . . . . . . . No Extra
Exports - Enter Order Level K60 Note listing Packing List requirements . . . . . . . . . . . . . . . . . . . . . . . . . . No Extra
Extra TRANSMITTAL LETTER copies:
PSID-036 (Special Service Code) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No Extra
It is Emerson Automation Solutions policy to accept accessories purchased by Emerson Sales Office or customers ONLY
when such accessories will prevent delay of shipment of product. Emerson policy is to purchase accessories direct rather
than to have these items supplied by Emerson Sales Offices or customers. In special situations when the factory cannot supply
accessories from other manufacturers such as solenoid valves, switches, special tags, etc., these accessories can be sent to the
factory for mounting on Fishert valves products. A handling charge will be imposed as follows:
Handling Charge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $393 non−standard each component*
Product Service No. PSFM-003 − requires R30 note with Emerson pre−approved contact name.
* Component is defined as a sub−level of the Emerson item number. For example, “Item 0001, component D.”
Note: Mounting kits for supplied equipment will be provided by Emerson unless pre−approval directs otherwise. The above charge
does not include any applicable charges for mounting kits provided by Emerson. Consult Global Industry Sales for pricing.
Rep Supplied Electric Actuators to be Factory Mounted with GX ISO 5210 Mounting:
Available for all GX material constructions. Apply option to standard GX construction. ISO 5210 mounting includes GX yoke,
actuator rod adaptor and spacer. Mounting is structured for Rotork actuators. Mounting may be used with any electric
actuator manufacturer with ISO 5210 F7 mount. Rep supplied actuator models other than Rotork will require form number
GG12102 completed at time of order entry for new mounting parts design. Order Entry will request this form upon receipt
of the order.
NOTE: This price extra is in addition to the Handling Charge listed above.
GX Body Size Rotork CVL Model List Price Extra
DN15−25, NPS 1/2−1 CVL500
$1,296
DN15−100, NPS 1/2−4 CVL1000, CVL1500
Emerson Automation Solutions Sales Office Supplied Equipment shall not include pressure retaining parts, other
valves/valve parts, or actuators and only applies to the purchase of buyout accessories or instruments.
The policy outlined below must be followed each time that Emerson Automation Solutions Sales Office wishes to furnish equipment.
The Emerson Automation Solutions Sales Office is responsible for ensuring that the equipment supplied is in working order, fits
on the Fisher valves equipment, and the mounting (if provided) is correct. If non−standard tubing and fittings are required, please
add the appropriate option and charges. Any additional costs incurred by Emerson to appropriately mount the furnished
accessories on the Fisher valves equipment will be billed back to the Emerson Automation Solutions Sales Office.
After Order Entry has been completed, the Emerson Automation Solutions Sales Office must send each component, including
appropriate mounting (if pre−approved), to the correct Emerson factory three (3) weeks prior to the factory acknowledged ship date.
The component and pre−approved mounting should be boxed together, but separately from other order/items. Each box should
include the appropriate original manufacture’s product instructions.
The Emerson Automation Solutions Sales Office must include a duplicate copy of the PRODCORP Screen OE39 for each order
and each item for the component being furnished. Attach said copy to equipment being supplied before forwarding to the Receiving
Department at the respective factory. When sending components to Marshalltown, please remember to send to GOVERNOR
ROAD RECEIVING. Drop Shipments are not allowed.
The following marks must be listed on the outside of each box:
1. Emerson Automation Solutions PO number
2. Emerson Automation Solutions Sales Office Furnished Equipment
3. Rep Order number, item number, and component
The Emerson factory will generate a PO for each component to the Emerson Automation Solutions Sales Office. If the Sales Office
requires reimbursement by Emerson for the equipment, the amount of credit must be stated as an R05 note at time of entry. At
the time Emerson ships and invoices the equipment, Emerson will issue the credit to the Emerson Automation Solutions Sales
Office. DO NOT INVOICE EMERSON AUTOMATION SOLUTIONS for the equipment.
This process is only valid for Fisher/Emerson Automation Solutions Equipment. We will not bill for Non−Emerson
Equipment.
As a service to our Emerson Automation Solutions Sales Offices, Emerson will invoice customers for shipments from Sales
Office stock when required by the customer. When this third party invoicing is required, the Emerson Automation Solutions
Sales Office will send a hard copy order to the Marshalltown Billing Department. The order should detail all possible
information that is to be shown on the invoice to the customer. The standard Emerson terms apply to the customer invoice
with the Emerson Automation Solutions Sales Office assuming the credit risk.
The amount of the customer invoice will be credited to the Emerson Automation Solutions Sales Office through its accounts
receivable less an administrative charge. The credit will be issued to the Emerson Automation Solutions Sales Office when
Emerson is paid by the customer. The administrative charge covers invoicing in four copies on standard Emerson invoice
forms. Additional attachments, documentation and/or certification will be priced on application and added to the
administrative invoice charge.
Invoice Charge: Fisher will impose an invoicing charge for any invoices which need to be re−issued for any non−factory
initiated change to the invoice details (e.g., Customer Number, Customer Purchase Order Number, “Invoice To” address,
“Ship To” address, pricing, or commission adjustments.) This charge may be added to the invoice or deducted from the
payable commission amount.
Catalogs
CONTENTS ONLY CONTENTS AND BINDER
CATALOG
Part Number Price (US$) Part Number Price (US$)
12 D103182X012 $10 D103183X012 $15
14 D103428X012 $20 D103184X012 $30
Price Book 100 --- --- D103190X012 $25
Control Valve Handbook --- --- D101881X012 $8
Control Valve Sourcebooks
Power and Severe Service --- --- D101449X012 $9
Refining --- --- D103205X012 $9
Pulp & Paper --- --- D103540X012 $9
Oil & Gas --- --- D103620X012 $9
SHIPPING POLICY: All orders from the Publication Zone will be shipped via FedEx (under 150 lbs) or freight (over
150 lbs) and will be prepaid by Emerson Automation Solutions, Marshalltown. For international shipments, this policy
includes the cost of transportation from the Publication Zone to the US point of embarkation if a freight forwarder or
broker is used.
The program includes dimensional data for valve−actuator assemblies, a step driven process for sizing and selection,
automated inputs for actuator sizing, powerful data comparison tools and more. [Please visit the homepage for Fisher
Specification Manager on FishWeb for more details on the program, its release, and other supporting information.]