Professional Documents
Culture Documents
BBU5900 Description 09 (20190218)
BBU5900 Description 09 (20190218)
Description
Issue 09
Date 2019-02-18
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Contents
1 Introduction....................................................................................................................................1
1.1 Functions........................................................................................................................................................................1
1.2 Exterior...........................................................................................................................................................................1
1.3 Boards.............................................................................................................................................................................2
1.3.1 UMPT..........................................................................................................................................................................3
1.3.2 UBBP...........................................................................................................................................................................8
1.3.3 USCU.........................................................................................................................................................................11
1.3.4 UPEU.........................................................................................................................................................................12
1.3.5 UEIU..........................................................................................................................................................................13
1.3.6 FAN...........................................................................................................................................................................14
1.4 Board Configuration.....................................................................................................................................................15
1.4.1 Board Configuration for a Single-RAT BBU5900....................................................................................................16
1.4.2 Board Configuration for a Separate-MPT BBU5900................................................................................................18
1.4.3 Board Configuration for a Co-MPT BBU5900.........................................................................................................23
2 Technical Specifications............................................................................................................25
2.1 Baseband Specifications...............................................................................................................................................25
2.1.1 GSM Baseband Specifications..................................................................................................................................25
2.1.2 UMTS Baseband Specifications................................................................................................................................25
2.1.3 LTE Baseband Specifications....................................................................................................................................26
2.1.3.1 LTE FDD Baseband Specifications........................................................................................................................26
2.1.3.2 LTE NB-IoT Baseband Specifications...................................................................................................................30
2.1.3.3 LTE FDD+NB-IoT Baseband Specifications.........................................................................................................34
2.1.3.4 LTE TDD+NB-IoT Baseband Specifications.........................................................................................................37
2.1.4 NR Baseband Specifications.....................................................................................................................................39
2.1.5 Co-BBP Baseband Specifications.............................................................................................................................47
2.2 Capacity Specifications................................................................................................................................................60
2.2.1 GSM Capacity Specifications....................................................................................................................................60
2.2.2 UMTS Capacity Specifications.................................................................................................................................60
2.2.3 LTE Capacity Specifications.....................................................................................................................................60
2.2.3.1 LTE FDD Capacity Specifications.........................................................................................................................60
2.2.3.2 LTE NB-IoT Capacity Specifications.....................................................................................................................61
2.2.3.3 LTE FDD+NB-IoT Capacity Specifications..........................................................................................................62
1 Introduction
1.1 Functions
The BBU5900 is a baseband control unit that provides the following functions:
Manages the entire base station system in terms of operation and maintenance (OM) and
system clock.
Processes signaling messages.
Provides physical ports for information exchange between the base station and the
transport network.
Provides an OM channel between the base station and the LMT, SMT, or U2000.
Processes uplink and downlink baseband signals, and provides common public radio
interface (CPRI) ports for communication with radio frequency (RF) modules.
Provides ports for receiving and transmitting signals from environment monitoring
devices.
1.2 Exterior
The BBU5900, 19 inches wide and 2 U high, is a universal baseband unit that can be applied
to diverse radio access technologies (RATs).
The BBU5900 exteriors with half-width and full-width slots are shown in the following two
figures.
1.3 Boards
The following table lists the boards supported by a BBU5900.
1.3.1 UMPT
The UMPT is a universal main processing and transmission unit. A BBU5900 can be
configured with a UMPTb, UMPTe, or UMPTg.
Functions
The UMPT provides the following functions:
Manages configurations and devices, monitors performance, and processes signaling of a
base station.
Processes signaling and manages resources for other BBU boards.
Provides the USB port, transmission port, and maintenance port for signal transmission,
automatic software upgrade, and BBU maintenance on the LMT or U2020.
Panel
Figure 1-1 shows the UMPTb1 panel.
Ports
Table 1-1 describes the ports on the UMTPb1 or UMPTb2.
interconnection with
the USU
USB USB 1 Used for software
upgrade and base
station
commissioning
through a USB flash
drive
CLK USB 1 Used for
multiplexing time of
day (TOD) clock
and test clock
signals
E1/T1 DB26 female 1 Used for input and
output of four
channels of E1/T1
signals
GPS SMA 1 The GPS port on
the UMPTb1 is
reserved for
future use.
The GPS port on
the UMPTb2 is
used for
transmitting RF
signals from the
antenna to the
satellite card.
RST N/A 1 Reset button
Supported RATs
The following table lists the RATs supported by the UMPTb, UMPTe, and UMPTg.
UMPTb Single-mode: GSM, UMTS, LTE FDD, LTE NB-IoT, LTE TDD
Multimode: GU, GL, UL, GUL
UMPTe Single-mode: GSM, UMTS, LTE FDD, LTE NB-IoT, LTE TDD, NR TDD
Multimode: GU, GL, UL, GUL, LN
UMPTg Single-mode: GSM, UMTS, LTE FDD, LTE NB-IoT, LTE TDD, NR TDD
Multimode: GU, GL, UL, GUL, LN, GULN
In the table, L indicates LTE FDD, but LTE FDD, LTE TDD, and LTE NB-IoT dynamically share
the specifications of the main control board.
For information about the LTE TDD single mode, see DBS5900 LTE TDD Product Description.
1.3.2 UBBP
The UBBP is a universal baseband processing unit. A BBU5900 can be configured with the
following types of UBBP boards:
UBBPd (UBBPd1/UBBPd2/UBBPd3/UBBPd4/UBBPd5/UBBPd6)
UBBPe (UBBPe1/UBBPe2/UBBPe3/UBBPe4/UBBPe5/UBBPe6/UBBPex2)
UBBPf (UBBPfw1)
UBBPg (UBBPg2/UBBPg2a/UBBPg3)
Functions
The UBBP provides the following functions:
Provides CPRI ports for communication with RF modules.
Supports deployment of multiple RATs on one UBBP.
Panel
The panels of the UBBPd1, UBBPd2, UBBPd3, UBBPd4, UBBPd5, and UBBPd6 are the
same, as shown in Figure 1-1.
The panels of the UBBPe1, UBBPe2, UBBPe3, UBBPe4, UBBPe5, and UBBPe6 are the
same, as shown in Figure 1-2.
Ports
Table 1-1 describes the ports on the UBBPd, UBBPe, or UBBPg.
Supported RATs
The following table lists the RATs supported by the UBBP.
UBBPg2 UMTS, LTE FDD, LTE NB-IoT, NR, UL, UM, LM, ULM
a
UBBPg3 UMTS, LTE FDD, LTE NB-IoT, NR, UL, UM, LM, TN, ULM
For information about the LTE TDD single mode, see DBS5900 LTE TDD Product Description.
1.3.3 USCU
The USCU is a universal satellite card and clock unit. A BBU5900 can be configured with a
USCUb11 or USCUb14.
Functions
The USCU provides the following functions:
The USCUb11 provides ports to communicate with the Remote Global Positioning
System (RGPS) and building integrated timing supply (BITS) equipment. It does not
support GPS signals.
The USCUb14 contains a u-blox satellite card. This board does not support RGPS
signals.
Panel
The USCUb11 and USCUb14 have the same panel, as shown in Figure 1-1.
Ports
The USCUb11 and USCUb14 have the same ports, as listed in Table 1-1.
signals.
The GPS port on
the USCUb11 is
reserved and
cannot receive
GPS signals.
RGPS PCB welded wiring 1 The RGPS port on
terminal the USCUb11
receives RGPS
signals.
The RGPS port on
the USCUb14 is
reserved and
cannot receive
RGPS signals.
TOD0 RJ45 1 Receives or
transmits
1PPS+TOD signals.
TOD1 RJ45 1 Receives or
transmits
1PPS+TOD signals,
and receives TOD
signals from the
M1000.
M-1PPS SMA 1 Receives 1PPS
signals from the
M1000.
BITS SMA 1 Receives BITS
clock signals, and
supports an adaptive
input from 2.048
MHz and 10 MHz
clock sources.
1.3.4 UPEU
The UPEU is a universal power and environment interface unit. A BBU5900 can be
configured with a UPEUe.
Functions
Converts –48 V DC input power into +12 V DC and provides an output power of 1100
W. Two UPEUe boards support 1100 W hot backup or 2000 W load sharing.
Provides two ports with each transmitting one channel of RS485 signals and two ports
with each transmitting four channels of Boolean signals.
Panel
Figure 1-1 shows the UPEUe panel.
Ports
Table 1-1 describes the ports on the UPEUe.
1.3.5 UEIU
The UEIU is a universal environment interface unit. A BBU5900 can be configured with a
UEIUb.
Functions
A UEIU performs the following functions:
Provides two ports, each transmitting one channel of RS485 signals.
Provides two ports, each transmitting four channels of Boolean signals, which can only
be dry contact or ordinary clock (OC) signals.
Transmits information reported by the environment monitoring device and alarm
information to the main control board.
Panel
Figure 1-1 shows the UEIUb panel.
Ports
Table 1-1 describes the ports on the UEIUb.
1.3.6 FAN
The FAN is a fan unit. A BBU5900 can be configured with an FANf.
Functions
The FAN provides heat dissipation for a BBU, controls the rotational speed of the fans,
detects the temperature of the FAN board, and reports the status of the fans and FAN board.
Panel
Figure 1-1 shows the FANf panel.
Unless otherwise specified, board configuration in this document is based on a BBU5900 with half-
width slots.
Among slots 0 to 5, any two horizontally adjacent half-width slots can be reconstructed into a
full-width slot. The number of the full-width slot is the same as that of the half-width slot on
the left before the reconstruction. The following figure shows an example of BBU5900 slots
in hybrid mode.
G&U indicates that GSM and UMTS use different main control boards. Other RAT combinations are
the same.
LTE FDD is used as a typical board configuration example. The board configuration of LTE NB-IoT
is the same.
Figure 1-3 Typical board configuration for a G&L BBU5900 (same as G&M BBU5900)
Figure 1-4 Typical board configuration for a U&L BBU5900 (same as U&M BBU5900)
G&U+L indicates that GSM and UMTS are deployed in BBU 0 and LTE is deployed in BBU 1.
Other RAT combinations are the same.
When a BBU3900 or BBU3910 involved in BBU interconnection is configured with a GTMU
board, the BBU3900 or BBU3910 must serve as the root BBU.
For details of BBU3900 and BBU3910 slot assignments, see BBU3900 Description and BBU3910
Description.
LTE FDD is used as a typical board configuration example. The board configuration of LTE NB-IoT
is the same.
The following table lists the typical board configuration for 1 BBU3900/BBU3910+1
BBU5900.
G&U+L Main control board: GTMU in slot Main control board: UMPT_L in slot
6 and UMPT_U in slot 7 7
Baseband processing board: Baseband processing board: A
− BBU3900: UBBP installed, in maximum of six UBBP_L boards
descending order of priority, in are installed, in descending order of
slots 3, 2, 0, 1, and 4 priority, in slots 4, 2, 0, 1, 3, and 5.
− BBU3910: UBBP installed, in
descending order of priority, in
slots 3, 2, 1, 0, and 4
G&U+ Main control board: GTMU in slot Main control board: UMPT_M in
M 6 and UMPT_U in slot 7 slot 7
Baseband processing board: Baseband processing board: A
− BBU3900: UBBP installed, in maximum of six UBBP_M boards
descending order of priority, in are installed, in descending order of
slots 3, 2, 0, 1, and 4 priority, in slots 4, 2, 0, 1, 3, and 5.
− BBU3910: UBBP installed, in
descending order of priority, in
slots 3, 2, 1, 0, and 4
The following table lists the typical board configuration for 1 BBU5900+1 BBU5900.
G&U+L Main control board: UMPT_G in Main control board: UMPT_L in slot
slot 7 and UMPT_U in slot 6 7
Baseband processing board: UBBP Baseband processing board: A
installed, in descending order of maximum of six UBBP_L boards
priority, in slots 4, 2, 0, 1, 3, and 5 are installed, in descending order of
priority, in slots 4, 2, 0, 1, 3, and 5.
G&U+ Main control board: UMPT_G in Main control board: UMPT_M in
M slot 7 and UMPT_U in slot 6 slot 7
Baseband processing board: UBBP Baseband processing board: A
installed, in descending order of maximum of six UBBP_M boards
priority, in slots 4, 2, 0, 1, 3, and 5 are installed, in descending order of
priority, in slots 4, 2, 0, 1, 3, and 5.
LTE FDD is used as a typical board configuration example. The board configuration of LTE NB-IoT is
the same.
Figure 1-6 Typical board configuration for a GL co-MPT BBU5900 (same as GM co-MPT
BBU5900 and GLM co-MPT BBU5900)
Figure 1-7 Typical board configuration for a UL co-MPT BBU5900 (same as UM co-MPT
BBU5900 and ULM co-MPT BBU5900)
Figure 1-8 Typical board configuration for a GUL co-MPT BBU5900 (same as GUM co-MPT
BBU5900 and GULM co-MPT BBU5900)
The typical board configuration for a co-MPT BBU5900 (NR involved) is as follows:
Main control board: A maximum of two main control boards are installed, in descending
order of priority, in slots 7 and 6.
Baseband processing board: A maximum of six UBBP boards are installed, in descending
order of priority, in slots 4, 2, 0, 1, 3, and 5.
2 Technical Specifications
UBBPd1 24
UBBPd2 24
UBBPd3 24
UBBPd4 24
UBBPd5 36
UBBPd6 48
Hybrid configurations of 1R and 2R cells are supported. In these configurations, the total number of
cells cannot exceed the maximum of 2R cells.
Hybrid configurations of 1R and 4R cells or 2R and 4R cells are supported. In these configurations,
the total number of cells cannot exceed the maximum of 4R cells.
: The Standard Ratio parameter for the board is set to FDD_ENHANCE(FDD Enhance).
(1)
Table 1-5 Number of LTE FDD UEs per main control board
Board Maximum Number Maximum Number of Uplink
of UEs in RRC Synchronized UEs
Connected Mode
3 4320 4320
5/10/15/20 4800 4800
UBBPg2 1.4 2016 2016
a
3 4320 4320
5/10/15/20 4800 4800
UBBPg3 1.4 4032 4032
3 8640 8640
5/10/15/20 9600 9600
15 110 55.056
20 150 75.376
Hybrid configurations of 1R and 2R cells are supported. In these configurations, the total number of
cells cannot exceed the maximum of 2R cells.
Hybrid configurations of 1R and 4R cells or 2R and 4R cells are supported. In these configurations,
the total number of cells cannot exceed the maximum of 4R cells.
(3)
: If a 400 kHz cell has been set up, the total number of cells cannot exceed three. If more than three
200 kHz cells have been set up, no 400 kHz cell can be set up.
(4)
:
For 4T4R cells: If a 400 kHz 4T4R cell has been set up, the total number of 4T4R cells cannot
exceed three. If more than three 200 kHz 4T4R cells have been set up, no 400 kHz cell can be set up.
For 2T4R cells: If more than six 2T4R cells have been set up, no 4T4R cell can be set up. If a 400
kHz 2T4R cell has been set up, the total number of cells cannot exceed six and the total number of
400 kHz cells cannot exceed three. If more than six 200 kHz 2T4R cells have been set up, no 400
kHz cell can be set up.
: If a 400 kHz cell has been set up, the total number of cells cannot exceed six and the total number
(5)
of 400 kHz cells cannot exceed three. If more than six 200 kHz cells have been set up, no 400 kHz
cell can be set up.
: If a 400 kHz cell or a 4T4R cell has been set up, the total number of cells cannot exceed six. If
(6)
more than six 2T4R cells have been set up, neither 400 kHz cells nor 4T4R cells can be set up.
: If a 400 kHz cell has been set up, the total number of cells cannot exceed six. If more than six 200
(7)
kHz cells have been set up, no 400 kHz cell can be set up.
(8)
: If a 400 kHz cell has been set up, the total number of cells cannot exceed twelve. If more than
twelve 200 kHz cells have been set up, no 400 kHz cell can be set up.
The following table lists the maximum number of UEs supported by an LTE NB-IoT cell.
(9)
: When Enhanced Multi-Carrier(NB-IoT) is enabled, a single 400 kHz NB-IoT cell supports a
maximum of 1200 UEs in RRC connected mode.
The following table lists the maximum number of UEs supported by a main control board
working in LTE NB-IoT.
Table 1-12 Number of LTE NB-IoT UEs per main control board
Board Maximum Number of Maximum Number of
UEs in RRC Connected UEs
Mode
The following table lists the maximum number of UEs supported by a baseband processing
board working in LTE NB-IoT.
Table 1-13 Number of LTE NB-IoT UEs per baseband processing board
Board Maximum Number of Maximum Number of
UEs in RRC Connected UEs
Mode
The following table provides the uplink and downlink LTE NB-IoT throughput per baseband
processing board.
Hybrid configurations of 1R and 2R cells are supported. In these configurations, the total number of
cells cannot exceed the maximum of 2R cells.
Hybrid configurations of 1R and 4R cells or 2R and 4R cells are supported. In these configurations,
the total number of cells cannot exceed the maximum of 4R cells.
If a UBBPd is configured with LTE NB-IoT cells, the maximum board throughput will decrease and
the proportion of the maximum throughput to the total LTE cell bandwidth will decrease.
If a UBBPd/UBBPe is configured, one LTE FDD cell can be associated with one in-band LTE NB-
IoT cell. (If a UBBPd is configured and Standard Ratio is set to FDD_ENHANCE, the LTE FDD
cells cannot be associated with in-band LTE NB-IoT cells.)
Table 1-17 Number of LTE FDD+NB-IoT UEs per main control board
Board Maximum Number of Maximum Number of LTE FDD+NB-
LTE NB-IoT UEs in IoT UEs
RRC Connected Mode
The maximum number of UEs supported by a board is affected by the traffic model. The maximum
number of UEs in the preceding table is based on the LTE NB-IoT traffic model. For details of the LTE
NB-IoT traffic model, see 2.7 Traffic Model.
The preceding specifications are supported only when uplink-downlink subframe configuration 1 or 2 is
used for TDD.
configuration 1)
1200 x uplink subframe ratio (subframe
configuration 2)
UBBPg2a DL: 2400 x downlink subframe ratio
UL:
900 x uplink subframe ratio (subframe
configuration 1)
1200 x uplink subframe ratio (subframe
configuration 2)
UBBPg3 DL: 4800 x downlink subframe ratio
UL:
1800 x uplink subframe ratio (subframe
configuration 1)
2400 x uplink subframe ratio (subframe
configuration 2)
: In this document, the NR TDD mmWave specifications in SRAN15.0 are for tests only.
(1)
FDD SUL.
Sub-6 GHz indicates frequency bands ranging from 3 GHz to 6 GHz. 3GPP defines the n77, n78,
and n79 bands as sub-6 GHz.
mmWave indicates millimeter wave bands. 3GPP defines the n257, n258, and n260 bands as
mmWave.
SUL is used to implement the UL and DL Decoupling feature. When UL and DL Decoupling is
configured, the SUL frequency band N83/N82 requires 10 MHz bandwidth resources, and the
frequency band N80/N84/N86 requires 15 MHz/20 MHz bandwidth resources.
For detailed spectrum, see 4.1 Appendix 1: NR Spectrum List.
When multiple SUL cells are configured, the SUL cells must be configured with the same number of
receive antennas and same bandwidth.
When multiple NR TDD sub-6 GHz cells are established on one baseband processing board, the
bandwidths and transmit and receive modes must be consistent for cells and the CPRI/eCPRI
interface types must be consistent for modules.
UBBPfw1 1200
UBBPg2a 600
UBBPg3 1200
A mmWave sector consists of multiple cells. In SRAN15.0 or SRAN15.1, a single sector supports a
maximum of four cells.
Table 1-30 Throughput per cell served by a baseband processing board (NSA) (SRAN15.0)
Board Cell Configuration Maximum DL Maximum UL
Throughput per Cell Throughput per Cell
(DL:UL = 4:1) (DL:UL = 4:1) (Mbit/s)
(Gbit/s) (64QAM)
(256QAM)
Table 1-31 Throughput per cell served by a baseband processing board (NSA) (SRAN15.1)
Cell Configuration Maximum DL Throughput Maximum UL
per Cell (DL:UL = 4:1) Throughput per Cell
(Gbit/s) (256QAM) (DL:UL = 4:1) (Mbit/s)
(64QAM)
MHz 32T32R
NR TDD sub-6 GHz: 20 1.080 63
MHz 64T64R
NR TDD sub-6 GHz: 40 2.267 139
MHz 64T64R
NR TDD sub-6 GHz: 50 2.857 177
MHz 64T64R
NR TDD sub-6 GHz: 60 3.519 214
MHz 64T64R
NR TDD sub-6 GHz: 80 4.689 293
MHz 64T64R
NR TDD sub-6 GHz: 90 5.293 332
MHz 64T64R
NR TDD sub-6 GHz: 100 5.960 372
MHz 64T64R
Table 1-32 Throughput per cell served by a baseband processing board (SA) (SRAN15.1)
Cell Configuration Maximum DL Throughput Maximum UL
per Cell (DL:UL = 4:1) Throughput per Cell
(Gbit/s) (256QAM) (DL:UL = 4:1) (Mbit/s)
(64QAM)
MHz 32T32R
NR TDD sub-6 GHz: 40 2.014 139
MHz 32T32R
NR TDD sub-6 GHz: 50 2.617 177
MHz 32T32R
NR TDD sub-6 GHz: 60 3.196 214
MHz 32T32R
NR TDD sub-6 GHz: 80 4.363 293
MHz 32T32R
NR TDD sub-6 GHz: 90 5.045 332
MHz 32T32R
NR TDD sub-6 GHz: 100 5.655 372
MHz 32T32R
NR TDD sub-6 GHz: 20 1.044 63
MHz 64T64R
NR TDD sub-6 GHz: 40 2.014 139
MHz 64T64R
NR TDD sub-6 GHz: 50 2.617 177
MHz 64T64R
NR TDD sub-6 GHz: 60 3.196 214
MHz 64T64R
NR TDD sub-6 GHz: 80 4.363 293
MHz 64T64R
NR TDD sub-6 GHz: 90 5.045 332
MHz 64T64R
NR TDD sub-6 GHz: 100 5.655 372
MHz 64T64R
Table 1-33 Throughput per sector served by a baseband processing board (NSA) (SRAN15.0)
Board Sector Maximum DL Maximum UL
Configuration Throughput per Throughput per Sector
Sector (DL:UL = 4:1) (DL:UL = 4:1) (Gbit/s)
(Gbit/s) (64QAM) (64QAM)
Table 1-34 Throughput per sector served by a baseband processing board (NSA) (SRAN15.1)
Boar Configuration Maximum DL Maximum UL
d Throughput per Throughput per
Sector (DL:UL = 4:1) Sector (DL:UL = 4:1)
(Gbit/s) (64QAM) (Gbit/s) (64QAM)
UMPTe 3600
UMPTg 7200
In GL, UL, and GUL co-BBP scenarios, the UBBP board supports hybrid configurations of 1R and 4R
LTE cells or hybrid configurations of 2R and 4R LTE cells.
bandwidth: 3600
UBBPd6 24 12 3x20 MHz 4T4R 1.4 MHz bandwidth: DL: 600
504 UL: 225
3 MHz bandwidth:
1080
5 MHz bandwidth:
1800
10/15/20 MHz
bandwidth: 3600
UBBP 6 512 768 6x1 384 384 3x20 MHz 1.4 MHz DL:
d6 5 4T4R bandwidth 600
: 504 UL:
3 MHz 225
bandwidth
: 1080
5 MHz
bandwidth
: 1800
10/15/20
MHz
bandwidth
: 3600
UBBP 6 384 512 6x1 288 288 3x20 MHz 1.4 MHz DL:
e3 5 2T2R bandwidth 450
: 504 UL:
3 MHz 225
bandwidth
: 1080
5 MHz
bandwidth
: 1800
10/15/20
MHz
bandwidth
: 3600
UBBP 6 512 768 6x1 384 384 3x20 MHz 1.4 MHz DL:
e4 5 4T4R bandwidth 600
: 504 UL:
3 MHz 225
bandwidth
: 1080
5 MHz
bandwidth
: 1800
10/15/20
MHz
bandwidth
: 3600
UBBP 6 512 768 6x1 384 384 6x20 MHz 1.4 MHz DL:
e5 5 2T2R bandwidth 600
: 1008 UL:
3 MHz 300
bandwidth
: 2160
5/10/15/20
MHz
bandwidth
: 3600
UBBP 6 512 768 6x1 384 384 6x20 MHz 1.4 MHz DL:
e6 5 4T4R bandwidth 1200
3x20 MHz : 1008 UL:
8T8R 3 MHz 600
bandwidth
: 2160
5/10/15/20
MHz
bandwidth
: 3600
UBBP 3 256 384 3x1 192 192 9x20 MHz 1.4 MHz DL:
e6 5 4T4R bandwidth 1200
3x20 MHz : 1512 UL:
8T8R 3 MHz 600
bandwidth
: 3240
5/10/15/20
MHz
bandwidth
: 3600
UBBP 6 512 768 6x1 384 384 6x20 MHz 1.4 MHz DL:
g2 5 4T4R bandwidth 1200
3x20 MHz : 1008 UL:
8T8R 3 MHz 600
(only bandwidth
10/15/20 : 2160
MHz) 5/10/15/20
MHz
bandwidth
: 3600
3 256 384 3x1 192 192 9x20 MHz 1.4 MHz DL:
5 4T4R bandwidth 1200
3x20 MHz : 1512 UL:
8T8R 3 MHz 600
(only bandwidth
10/15/20 : 3240
MHz)
UB 6 512 768 6x15 384 384 3x200 520,0 243, 1800 DL:
BPd kHz 00 000 0.318
6 4T4R UL:
0.6
UB 6 384 512 6x15 288 288 3x200 635,0 297, 1800 DL:
BPe kHz 00 000 0.318
3 2T2R UL:
SRAN 0.6
13.1
and
later
versio
ns:
3x400
kHz
2T4R
UB 6 512 768 6x15 384 384 3x200 635,0 297, 1800 DL:
BPe kHz 00 000 0.318
4 4T4R UL:
SRAN 0.6
13.1
and
later
versio
ns:
3x400
kHz
4T4R
UB 6 512 768 6x15 384 384 3x200 635,0 297, 1800 DL:
BPe kHz 00 000 0.666
5 4T4R UL:
SRAN 1.2
13.1
and
later
versio
ns:
3x400
kHz
4T4R
UB 6 512 768 6x15 384 384 6x200 983,0 459, 3600 DL:
BPe kHz 00 000 1.332
6 4T4R UL:
SRAN 2.4
13.1
and
later
versio
ns:
6x400
kHz
4T4R
UB 6 512 768 6x15 384 384 6x400 1,156, 540, 3600 DL:
BPg kHz 000 000 1.332
2 4T4R UL:
2.4
UB 6 512 768 6x15 384 384 6x400 1,156, 540, 3600 DL:
BPg kHz 000 000 1.332
2a 4T4R UL:
2.4
UB 12 102 102 12x1 768 768 12x40 2,081, 972, 4800 DL:
BPg 4 4 5 0 kHz 000 000 2.664
3 4T4R
UL:
4.8
Number of LTE 3x10 MHz 4T4R 3x10 MHz 2T2R 3x10 MHz 4T4R
FDD Cells
Maximum 3x200 kHz 4T4R 3x200 kHz 2T2R 3x200 kHz 4T4R
Number of LTE
NB-IoT Cells
Maximum 1800 which can be 1800 which can be 1800 which can be
Number of LTE shared with LTE shared with LTE shared with LTE
NB-IoT UEs in FDD; ≤ 3600 in total FDD; ≤ 3600 in FDD; ≤ 3600 in total
RRC Connected total
Mode
Maximum Number of LTE NB-IoT 1800 which can be shared with LTE FDD; ≤
UEs in RRC Connected Mode 3600 in total
Maximum Number of LTE NB-IoT 1800 which can be shared with LTE FDD; ≤
UEs in RRC Connected Mode 3600 in total
Number of 6 3 12
UMTS Cells
Codes
Number of LTE 6x20 MHz 4T4R 9x20 MHz 4T4R 12x20 MHz 4T4R
FDD Cells 3x20 MHz 8T8R 3x20 MHz 8T8R 6x20 MHz 8T8R
(only 10/15/20 (only 10/15/20 (only 10/15/20
MHz) MHz) MHz)
Maximum 1.4 MHz 1.4 MHz 1.4 MHz bandwidth:
Number of LTE bandwidth: bandwidth: 1512 2016
FDD UEs in 1008 3/5/10/15/20 MHz 3/5/10/15/20 MHz
RRC Connected 3 MHz bandwidth: 2520 bandwidth: 3360
Mode bandwidth:
2160
5/10/15/20 MHz
bandwidth:
2520
Maximum LTE DL: 1200 DL: 1200 DL: 2400
FDD UL: 600 UL: 600 UL: 1200
Throughput
(Mbit/s)
Maximum 3x400 kHz 4T4R 3x400 kHz 4T4R 3x400 kHz 4T4R
Number of LTE
NB-IoT Cells
Maximum 1800 which can be 1800 which can be 1800 which can be
Number of LTE shared with LTE shared with LTE shared with LTE FDD;
NB-IoT UEs in FDD; ≤ 3600 in FDD; ≤ 3600 in total ≤ 4800 in total
RRC Connected total
Mode
Item Specifications
layer is 2 Gbit/s.
One UMPTe:
The sum of uplink and downlink data rates at the MAC
layer is 10 Gbit/s.
One UMPTg:
The sum of uplink and downlink data rates at the MAC
layer is 20 Gbit/s.
Maximum number of UEs in One UMPTb: 10,800
RRC connected mode One UMPTe: 14,400
One UMPTg: 28,800
LTE FDD and LTE NB-IoT share the maximum number of LTE cells and UEs on the main control
board.
Item Specifications
LTE FDD and TDD dynamically share the specifications of the main control board.
LTE FDD cells support the 1.4, 3, 5, 10, 15, or 20 MHz bandwidth.
For details of bandwidths supported by LTE TDD cells, see DBS5900 LTE TDD Product Description.
Maximum number of Three UBBPfw1 boards and two Six UBBPg3 boards and
cells UMPTe boards: two UMPTg boards:
NR TDD sub-6 GHz: 18 cells, NR TDD sub-6 GHz: 36
100 MHz, 8T8R cells, 100 MHz, 8T8R
NR TDD sub-6 GHz: 9 cells, NR TDD sub-6 GHz: 18
100 MHz, 32T32R cells, 100 MHz,
NR TDD sub-6 GHz: 9 cells, 32T32R
100 MHz, 64T64R NR TDD sub-6 GHz: 18
NR TDD mmWave: 12 cells, cells, 100 MHz,
100 MHz, 4T4R (SRAN15.0) 64T64R
NR TDD mmWave: 18 cells,
NR TDD mmWave: 72
200 MHz, 4T4R (SRAN15.0) cells, 100/200 MHz,
4T4R
Maximum throughput DL+UL: 20 Gbit/s DL+UL: 50 Gbit/s
Maximum number of 3600 7200
UEs in RRC connected
mode
Maximum number of 10,800 21,600
DRBs per gNodeB
When the UBBPfw1 is configured, the maximum numbers of LTE and NR cells are restricted by both
main control board and baseband processing board capabilities. This section only lists the maximum cell
numbers in typical configurations. When the UMPTe is configured in LN concurrency scenarios, a
maximum of 72 LTE cells and 36 NR cells are supported, and a maximum of 5400 LTE UEs and 2400
NR UEs in RRC connected mode are supported.
The maximum numbers of LTE and NR cells are restricted by both main control board and baseband
processing board capabilities. This section only lists the maximum cell numbers in typical
configurations. In GULN concurrency scenarios, a maximum of 72 GSM cells, 48 UMTS cells, 72 LTE
cells, and 72 NR cells are supported.
UMPTb 360,000
UMPTe 1,620,000
UMPTg 3,240,000
UBBPd3/UBBPd4 270,000
UBBPd5/UBBPd6 396,000
UBBPe1/UBBPe2 270,000
UBBPe3/UBBPe4 432,000
UBBPe5 540,000
UBBPe6 648,000
UBBPex2 432,000
UBBPg2 720,000
UBBPg2a 720,000
UBBPg3 1,296,000
UMPTa 432,000
UMPTb 540,000
UMPTe 2,430,000
UMPTg 4,860,000
UBBPd3/UBBPd4 405,000
UBBPd5/UBBPd6 594,000
UBBPe1/UBBPe2 405,000
UBBPe3/UBBPe4 648,000
UBBPe5 810,000
UBBPe6 972,000
UBBPg2 1,080,000
UBBPg2a 1,080,000
UBBPg3 1,944,000
UMPTb 252,000+161,000
UMPTe 1,296,000+484,000
UMPTg 2,592,000+968,000
UBBPd3/UBBPd4 189,000+121,000
UBBPd5/UBBPd6 277,000+177,000
UBBPe1/UBBPe2 189,000+121,000
UBBPe3/UBBPe4 302,000+193,000
UBBPe5 378,000+242,000
UBBPe6 454,000+292,000
UBBPg2 504,000+324,000
UBBPg2a 504,000+324,000
UBBPg3 907,000+583,000
UMPTb 360,000
UMPTe 1,620,000
UMPTg 3,240,000
UBBPe4 302,000+193,000
UBBPe6 454,000+292,000
UBBPg2 504,000+324,000
UBBPg2a 504,000+324,000
UBBPg3 907,000+583,000
For details of the Huawei control plane reference traffic model, see 2.7.3 NR Traffic Model.
If GSM is configured with 72 TRXs (S24/24/24), each TRX can be configured with only one
SDCCH. If GSM is configured with 24 TRXs (S8/8/8), each TRX can be configured with three
SDCCHs.
Common NodeB Application Protocol (CNBAP) indicates the signaling traffic of a NodeB over the
Iub interface. The NodeB application part (NBAP) is defined in 3GPP specifications, and one
CNBAP indicates one radio link (RL) establishment procedure.
In a typical GL, UL, or GUL scenario where the signaling specifications of GSM and UMTS remain
unchanged, LTE signaling specifications (BHCA) of the main control board are affected after LTE
NB-IoT is available. LTE FDD and LTE NB-IoT share LTE signaling processing specifications of
the main control board. On commercial networks, it is recommended that 30% of LTE signaling
processing specifications be allocated to LTE NB-IoT.
1xUMPTb1+4xUBBPd2_U 24 800
1xUMPTb1+2xUBBPd2_U 24 400
1xUMPTb1+5xUBBPd1 24 1000
1xUMPTe+5xUBBPd1 24 1000
1xUMPTb1+5xUBBPd3_L 24 504,000
1xUMPTb1+3xUBBPd3_L 24 504,000
1xUMPTb1+2xUBBPd3_L 24 504,000
1xUMPTb1+2xUBBPd3 48 414,000
1xUMPTe+6xUBBPd3 48 1,170,000
1xUMPTe+6xUBBPe4_L 24 1,350,000
1xUMPTb1+2xUBBPd2_U 18 400
+3xUBBPd3_L 414,000
1xUMPTb1+3xUBBPd2_U 18 500
+2xUBBPd3_L 414,000
1xUMPTb1+1xUBBPd6_U 18 500
L+1xUBBPd1_U+1xUBBP 414,000
d3_L
1xUMPTb1+2xUBBPd2_U 18 500
+1xUBBPd3_L 270,000
1xUMPTb1+4xUBBPd1_U 24 800
+1xUBBPd3_L 234,000
1xUMPTe+1xUBBPd6_U+ 24 350
5xUBBPd3_L 1,170,000
1xUMPTe+2xUBBPd6_U+ 24 600
4xUBBPe4_L 900,000
When the UBBPfw1 is configured, the LTE and NR signaling specifications are restricted by both main
control board and baseband processing board capabilities. This section only lists the signaling
specifications in typical configurations. When the UMPTe is configured in LN concurrency scenarios,
the maximum LTE and NR signaling specifications are 540,000 BHCAs and 432,000 BHCAs,
respectively.
capabil
ity 2
(1)
: The topologies vary with the RATs and scenarios. For details, contact Huawei frontline engineers.
(2)
: The specifications are supported using a QSFP28 to SFP28 adapter (QSA28) or QDA.
For details of QSA, see 4.2 Appendix 2: QSA28.
Table 1-1 Mapping between the CPRI port rate and the number of GSM TRXs
CPRI Port Rate (Gbit/s) Number of 1T2R TRXs Number of 2T2R/1T4R
TRXs
1.25 24 12
2.5 48 24
4.9 48 24
9.8 48 24
Table 1-2 Mapping between the CPRI port rate and the number of UMTS cells
CPRI Port Rate (Gbit/s) Number of 1T2R/2T2R* Cells
1.25 4
2.5 8
4.9 16
6.144 24
9.8 32
40.55 48
The asterisk (*) indicates that the number of supported cells is reduced by half if the 2T2R cell supports
VAM and the two TX antennas are configured on two RF modules in two CPRI links for VAM.
Table 1-3 Mapping between the CPRI port rate and the number of LTE FDD cells
CPRI Number of Number of 1T2R/2T2R Number of 1T1R Cells
Port 2T4R/4T4R Cells
Rate Cells
(Gbit/s
)
Table 1-4 Mapping between the CPRI port rate and the number of LTE NB-IoT cells
CPRI Port Rate Number of 1T2R/2T2R Number of 2T4R/4T4R
(Gbit/s) Cells Cells
1.25 4 2
2.5 8 4
4.9 16 8
9.8 32 16
Table 1-5 Mapping between the CPRI port rate and the number of cells in an NR scenario
M CPR Number of Cells Number of Cells Number of Number of
od I (Sub-6 GHz (Sub-6 GHz Cells Cells
e Port 64T64R/32T32R) 8T8R) (mmWave (mmWave
Rate 4T4R) 2T2R)
(Gbi
t/s)
I 1 (cell bandwidth =
30/40 MHz)
CP 1x25 - 2 (cell bandwidth = - 8 (cell
RI 20/30/40/50/60/70/8 bandwidt
0/90/100 MHz) h = 100
MHz)
4 (cell
bandwidt
h = 200
MHz)
CP 1x10 - 2 (cell bandwidth - -
RI = 20/30/40
MHz)
1 (cell bandwidth
= 50/60/70/80
MHz)
The cell types and the number of supported cells or sectors in the preceding table only apply to typical
scenarios. For cell types that are not listed here, contact Huawei engineers to obtain the corresponding
number of supported cells.
The maximum distance between a BBU and AAUs/RRUs depends on the capabilities of optical modules
or fronthaul solutions.
The following maximum distances between a BBU and AAUs/RRUs are based on fronthauls in a point-
to-point direct drive mode.
GSM 40 km
UMTS 40 km
LTE UBBPd/UBBPe: 40 km
UBBPg: 40 km (CPRI); 20 km (eCPRI)
NR 10 km: 25 Gbit/s optical modules are used for NR TDD (sub-6 GHz).
10 km: 40 Gbit/s or 100 Gbit/s optical modules are used for NR TDD (sub-6
GHz) with AAUs using CPRI ports.
RAT Specifications
This section describes only the transmission ports on a BBU working in a single RAT. The number of
transmission ports on a BBU working in multiple RATs equals the sum of the transmission ports on the
boards in each RAT.
FANf 2100 W
Item Specifications
Rating
Atmospheric pressure 70 kPa to 106 kPa
Noise power level ETS 300 753 3.1
≤ 7.2 bels
Storage time The product must be installed and put into use within a year after
being delivered; otherwise, it may malfunction.
(1)
: Traffic models described in the preceding table are obtained during busy hours. @BH refers to at
busy hour.
The following table describes the user plane (UP) specifications for traffic model 1.
Based on the definition of traffic model 1, one BHCA (for example, one combined PS call) is
defined by taking every item in traffic model 1 divided by the PS call density. The details of
one BHCA are listed below.
PS Call Attempts 1
Dedicated Bearer Attempts 0.0278
TAU & Attach & Detach Attempts 0.1667
24 40%
2 40%
1 15%
0.5 5%
0 (0 dB) 100%
1 (10 dB) 0%
2 (20 dB) 0%
(times)
Paging number @BH (times) 400
(2)
: Traffic models described in the preceding table are obtained during busy hours. @BH refers to at
busy hour.
(3)
: The TAU timer is extended to 310 hours.