The 79-PF LED achieves a seamless, continuous line of light while softly Catalog # Type
washing perimeter walls. The 79-PF LED incorporates an optical grade
acrylic reflector that can be shipped in lengths up to 40 ft. Installed
TM
after the housing and wiring, the PentaFlex reflector beautifully Project
eliminates gaps and construction flaws. Now available with advanced
LED technology, the 79-PF represents a perfect harmony of efficacy and
refinement. Comments Date
Prepared by
PentaFlexTM
PentaFlex TM
Reflector LED
9 1/32"
Perimeter
Direct Wall Wash
Ceiling 8"
Extrusion
Wall Rail
Wall Extrusion
1 3/8"
7/8"
SERIES OPTIONS LIGHT LEVEL COLOR TEMPERATURE LENGTH OF RUN INPUT VOLTAGE
S79 = S
eries 79 PF = PentaFlexTM -1 = Light Level 1 (1386 Lms @ 29 W) -L30 = LED 3000K -Length of Run = -U = Universal (120V-277V) 2
(346 Lumens per ft @ 7.25W) -L35 = LED 3500K ____Ft ____In -3 = 347V 3
-2 = Light Level 2 (1802 Lms @ 38 W) -L40 = LED 4000K
(450 Lumens per ft @ 9.5W)
DD = 0-10V Dimming Driver 4 -1 = Single Circuit B = Battery Pack 5 -DC = Dust Cover -W = Matte White Trim
5LT = FifthLight DALI -S = Secondary Circuit D = Standard 4 -EP = End Plate (Flanged) -CC = Custom Color Trim
E = Emergency -M = Mirror Option
Notes:
* See page 2 for specific notes
Cooper Lighting Solutions
18001 East Colfax Avenue ADN142457
Aurora, CO 80011 Specifications and 05-09-19
P. 303-393-1522 dimensions subject to 1 of 3
www.cooperlighting.com change without notice.
N E O - R AY
Photometric Data - All data certified to LM-79 standards in a NAVLAB approved testing facility
208
NOTES
1. Not all dimming options available every length; please consult factory for specific details
2. For configurable runs; specify exact length; do not round up. Upon product configuration / quoting, actual fixture length will be adjusted to nominal length (1 ft increments).
Nominal fixture length will accommodate up to +6 inches of field adjustability at both ends. Sub-foot length is achieved in the field during installation by trimming 6 inch
end extensions.
3. 347V is achieved using remote transformer.
4. Not all dimming options available every length; please consult factory for specific details.
5. Battery pack options are not available in every length; please consult factory for specific details.
NOTE: A pair of end closures per run are provided by default. No flanged endplates are provided. If flanged endplates are required,
order “EP” in catalog nomenclature. EP option includes a pair of left and right flanged endplates.
12-1/4”
(311mm)
Pattern Leg 1
.
EP = Flanged endplate option.
12-1/4” Attach flanged endplate to trim tile or
(311mm) sheet rock.
Inside Corner
90o Unlit Extension
NOTE: Patterns require corner sections.
Order corner sections seperately as required.
Wall Side
Pattern Leg 2
2-11/16”
(68mm) Pattern Leg 3
2-11/16”
Outside Corner (68mm)
90o Unlit
Nominal Length Minimum Length Maximum Length Nominal Length Minimum Length Maximum Length
(Feet) (Lighted) (Lighted) (Feet) (Lighted) (Lighted)
3 3 4 52 52 53
4 4 5 53 53 54
5 5 6 54 54 55
6 6 7 55 55 56
7 7 8 56 56 57
8 8 9 57 57 58
9 9 10 58 58 59
10 10 11 59 59 60
11 11 12 60 60 61
12 12 13 61 61 62
13 13 14 62 62 63
14 14 15 63 63 64
15 15 16 64 64 65
16 16 17 65 65 66
17 17 18 66 66 67
18 18 19 67 67 68
19 19 20 68 68 69
20 20 21 69 69 70
21 21 22 70 70 71
22 22 23 71 71 72
23 23 24 72 72 73
24 24 25 73 73 74
25 25 26 74 74 75
26 26 27 75 75 76
27 27 28 76 76 77
28 28 29 77 77 78
29 29 30 78 78 79
30 30 31 79 79 80
31 31 32 80 80 81
32 32 33 81 81 82
33 33 34 82 82 83
34 34 35 83 83 84
35 35 36 84 84 85
36 36 37 85 85 86
37 37 38 86 86 87
38 38 39 87 87 88
39 39 40 88 88 89
40 40 41 89 89 90
41 41 42 90 90 91
42 42 43 91 91 92
43 43 44 92 92 93
44 44 45 93 93 94
45 45 46 94 94 95
46 46 47 95 95 96
47 47 48 96 96 97
48 48 49 97 97 98
49 49 50 98 98 99
50 50 51 99 99 100
51 51 52 100 100 101