You are on page 1of 1

15317 15317 15317 15317 15317 15317 PROPOSED

18317
15317 3000 4717 4717 4717 4717
SURYA KIDNEY CARE
15317 HOSPITAL

8242
8242

8242

8242

8242
3000

PARKING SERVICES
DIALYSIS
SERVICES
ELECTRIC
SERVICES
WASTE
SERVICES
CSSD
PLOT NO. D 226
4717 UNIT PANEL MANAGEMENT INDUSTRIAL FOCAL POINT

13425
13425

13425

13425

13425

13425
ROOM
PHASE 8-B , SECTOR 90
S.A.S NAGAR
BELONGING TO:
RAMP RAMP RAMP RAMP RAMP RAMP
11821

SHRI. ARJINDER SINGH BAINS ,

600

600

600

600
1000 1000 1000 1000 1000 1000 1000 1000 SMT. ARAPANA BAINS,
SHRI. ANMOL SINGH BAINS&
G G G G G G G G

600

600

600

600
SHRI. AMARBIR SINGH BAINS

NOTES :
1)Dimensions on the drawings are
to be read and not scaled.
STILT 2)All dimensions are in mm.
PARKING 3) This building is to have 100%
C power backup.

20329
20329

20329

20329

20329

20329
AREA=306.78 4) Artificial lighting and ventilation

20330
is to be strictly as per National
Building Code 2016 - Vol.-II, Part
20329

8 -Building services.
5) Arrangements for disposal of
hospital waste have to be made

64113
64113

64113

64113

64113

64113
as per the bio- medical waste

2100 450

2100 450

2100 450

2100 450
1200

1200

1200

1200
5467 400 5467 400 5467 400 5467 400 (management and handling)
FIRE F FIRE F FIRE F FIRE F 5467 rules1998
STAIRCASE E STAIRCASE E STAIRCASE E STAIRCASE E 6)Fire fighting system for above
F F F F
62509

2400
68700

STAIR

1200

1200

1200

1200
B 900 B 900 B 900 B 900 than 15 m building shall be

7230

7230

7230

7230

7230
7230

CASE provided as per National Building

50689
10030
10030

10030

10030

10030

10030
FIRE 870 870 870 870
B
TOWER
FIRE FIRE FIRE FIRE Code 2016 - Vol.-I, Part 4 -Fire

7130

7130

7130

7130
STAIR
7130

TOWER TOWER TOWER TOWER


H 1715 900 1715 900 1715 900 1715 900
and life safety.
CASE 3454 3600
H 3600
H 3600
H 3600
H 7) Fire Safety and structure
D D D D
10030

FIRE FIRE FIRE FIRE

2663

2663

2663

2663
2800

2800

2800

2800

2800
450

450

450

450
2100

2100

2100

2100
FIRE CONTROL
2054

CUM METER LIFT 2400 E LIFT 2400 E LIFT 2400 E LIFT 2400 E LIFT stability norms shall be provided
ROOM
F C C C C as per National Building Code
400 400 400 400 2016
LIFT 8)Fire NOC shall be obtained from

A A A A competent authority
occupying the building.
before

9)Toilet , ramp & parking shall be


STILT provided as per provision of "The
Person with Disability

20329
20329

20329

20329

20329

20329
PARKING
(Equal Opportunities-Protection
of Rights and Full Participation)
AREA=306.78
act 1995
20329

10)Building plan shall be got


approved from competent
authority before starting any
development work at site.
1000 1000 1000 1000 11) 24x7 power backup and
600

600

600

600
1000 1000 1000 1000 HVAC, Mechanical ventilation &
600

600

600

600
15317
G G G G G G G G air conditioning shall be provided
NON F.A.R AREA OF S+5 as per National Building Code
COVERED AREA OF STILT FLOOR= 15.317X TOTAL AREA S+1 (FIRST FLOOR) TOTAL AREA S+2 (SECOND FLOOR) TOTAL AREA OF S+3 (THIRD FLOOR) TOTAL AREA OF S+4 (FOURTH FLOOR) SERVICE FLOOR 2016
64.113 = 982.01SQM = 15.317X 64.113 = 982.01SQM = 15.317X 64.113 = 982.01SQM = 15.317X 64.113 = 982.01SQM = 15.317X 64.113 = 982.01SQM (FIFTH FLOOR) = 964.63 SQM 12)Automatic drainage system
TOTAL AREA TOTAL AREA TOTAL AREA TOTAL AREA TOTAL AREA TOTAL AREA
15.317X 15.317X 15.317X 15.317X 15.317X 15.317X shall be provided for drainage of
3195

982.01 SQM 982.01 SQM 982.01 SQM 982.01 SQM 982.01 SQM 982.01 SQM
18317 X 64.113 X 64.113 X 64.113 X 64.113 X 64.113 X 64.113 water from the basement
15317

COVERED AREA OF BASEMENT


Y NON F.A.R AREA Y NON F.A.R AREA Y NON F.A.R AREA Y NON F.A.R AREA Y NON F.A.R AREA
FIRE FIRE FIRE FIRE FIRE
STAIRCASE 5.467 X STAIRCASE 5.467 X STAIRCASE 5.467 X STAIRCASE 5.467 X STAIRCASE 5.467 X
39.53 SQM 39.53 SQM 39.53 SQM 39.53 SQM 39.53 SQM
B 7.230 B 7.230 B 7.230 B 7.230 B 7.230 AREA
18.317 X FIRE LIFT FIRE LIFT FIRE LIFT FIRE LIFT =37.59
A 1258.4 SQ MT PARKING
STILT
306.78X2 613.56 SQM C 3.6X2.8 10.08 SQM C 3.6X2.8 10.08 SQM C 3.6X2.8 10.08 SQM C 3.6X2.8 10.08 SQM REVISION RECORD DATE
68.700
C PLUMBING PLUMBING PLUMBING PLUMBING

13425
AR
SHAFT SHAFT SHAFT SHAFT
METER ROOM
2.66X1.715 4.562 SQM 2.66X1.715 4.562 SQM 2.66X1.715 4.562 SQM 2.66X1.715 4.562 SQM
TOTAL 1258.4 SQ MT F 3.454 X 2.054 7.095 SQM D
PLUMBING
D
PLUMBING
D
PLUMBING
D
PLUMBING
FIRE TOWER SHAFT 2(2.1X0.9 SHAFT 2(2.1X0.9 SHAFT 2(2.1X0.9 SHAFT 2(2.1X0.9
3.42 SQM 3.42 SQM 3.42 SQM 3.42 SQM DATE: APRIL, 2021

H 2.4 X 7.13 17.112 SQM


FHC
E -(0.4X0.45)
FHC
E -(0.4X0.45)
FHC
E -(0.4X0.45)
FHC
E -(0.4X0.45) SCALE:-

SHEET TITLE:-
NON F.A.R AREA RAMP 15.317X 2(1.2 X0.8) 1.92 SQM 2(1.2 X0.8) 1.92 SQM 2(1.2 X0.8) 1.92 SQM 2(1.2 X0.8) 1.92 SQM
+ PARKING 13.425
205.63SQM F
PLUMBING
F
PLUMBING
F
PLUMBING
F
PLUMBING
AREA STATEMENT - 2
SHAFT SHAFT SHAFT SHAFT NON FAR RAMP MUMTY AREA
F.A.R AREA 4(1.0X0.6) 2.4 SQM 4(1.0X0.6) 2.4 SQM 4(1.0X0.6) 2.4 SQM 4(1.0X0.6) 2.4 SQM
Y NON F.A.R AREA 882.9SQM
G G G G 5467
FIRE TOWER FIRE TOWER FIRE TOWER FIRE TOWER
SKCH/SSA-2021/AR/03
H 2.4 X 7.13 17.112 SQM H 2.4 X 7.13 17.112 SQM H 2.4 X 7.13 17.112 SQM H 2.4 X 7.13 17.112 SQM
15.317X 15.317X 15.317X 15.317X STAIR
RAMP 205.63SQM RAMP 205.63SQM RAMP 205.63SQM RAMP 205.63SQM

7230
+DIALYSIS 13.425 +ELECTRIC 13.425 +WASTE 13.425 +CSSD 13.425 CASE

9730
UNIT PANEL MANAGEMENT SERVICES
TOTAL F.A.R AREA 982.01-882.9 SERVICES SERVICES SERVICES MUMTY
= X-Y

99.08 SQM
Y NON F.A.R AREA 284.65 SQM Y NON F.A.R AREA 284.65 SQM Y NON F.A.R AREA 284.65 SQM Y NON F.A.R AREA 284.65 SQM SIGNATURE
OWNER

LIFT
TOTAL F.A.R AREA 982.01-284.65 TOTAL F.A.R AREA 982.01-284.65 TOTAL F.A.R AREA 982.01-284.65 TOTAL F.A.R AREA 982.01-284.65
TOTAL BUILT UP 882.9+99.08 = X-Y = X-Y = X-Y = X-Y NON F.A.R STAIRCASE MUMTY AREA
OF GROUND FLOOR
TOTAL 697.358 SQM TOTAL 697.358 SQM TOTAL 697.358 SQM TOTAL 697.358 SQM AR HARBAX SINGH
TOTAL STAIRCASE 5.467X CHIEF ARCHITECT PUNJAB (Retd.)
982.01 SQM MUMTY 53.19 SQM CA/76/02395
9.73 #83 PREET AVENUE , BHUPINDRA ROAD SIGNATURE
PATIALA-147001 ARCHITECT

TOTAL BUILT UP 284.65+697.358 TOTAL BUILT UP 284.65+697.358 TOTAL BUILT UP 284.65+697.358 TOTAL BUILT UP 284.65+697.358 RAMP (15.317X
MUMTY 168.04 SQM THIS DRAWING IS THE INTELLECTUAL PROPERTY
OF SECOND FLOOR OF SECOND FLOOR OF SECOND FLOOR OF SECOND FLOOR 13.425)-37.59 AND COPYRIGHT OF M/S SURINDER SAWHNEY
ASSOCIATES.THIS DRAWING SHALL NOT BE COPIED
TOTAL OR REPRODUCED IN WHOLE OR PART IN ANY
TOTAL 982.01 SQM TOTAL 982.01 SQM TOTAL 982.01 SQM TOTAL 982.01 SQM 221.23 SQM MANNER WHATSOEVER WITHOUT THE WRITTEN
PERMISSION OF M/S SURINDER SAWHNEY
ASSOCIATES.

You might also like