Professional Documents
Culture Documents
Parametros Ericsson HO
Parametros Ericsson HO
bandIndicator
Indicates the frequency band of the external GSM cell.
The BCCH frequency is unique for all GSM bands except the two GSM
bands DCS1800 and PCS1900, so the band indicator is needed to
discriminate between the two. When the ExternalGsmCell has a BCCH
frequency indicating some other frequency band, then the band
indicator is not needed and may be set to "Not applicable".
bcchFrequency BCCH frequency code in the GSM cell. Contains the absolute radio
frequency channel number of the BCCH channel for the GSM cell. It
uniquely identifies the BCCH.
cellReserved Indicates if this cell shall be reserved for operator use. If it is reserved,
there will be no service to the UEs.
fachMeasOccaCycLenCoeff
Fach Measurement Occasion Cycle Length coefficient. A factor used
when the UE performs inter-frequency and inter-system
measurements. The UE uses this parameter to calculate the interval
length in order to determine the repeating cycle of the measurement.
FALSE = No
TRUE = Yes
Idle Mode Parameter Summary
maxTxPowerUl
The maximum UE transmission power on the RACH when accessing
the system. Used in UE functions for cell selection/reselection in idle
mode and connected mode. Also used by UTRAN to control the
maximum TX power level an UE may use.
mnc The MNC part of the PLMN identity used in the radio network.
Resolution: 2
qHyst2 The hysteresis value of the serving cell. Used to perform cell ranking
for the serving cell.
Resolution: 2
qOffset1sn Signal stength offset between source and target cells. Used when the
IE "cell_selection_and_reselection_quality_measure" in SIB 11/12 is
set to "CPICH RSCP". This is configured through
UtranCell::qualMeasQuantity.
Unit: 1 dB
Resolution: 1
-50 : -50dB
-49 : -49dB
-48 : -48dB
......
50 : 50dB
qOffset1sn (WCDMA neighbor relation)
qOffset1sn (GSM neighbor relation)
qOffset2sn (WCDMA neighbor relation)
qQualMin Used in UE functions for cell selection/reselection in idle mode and
connected mode. Minimum required (acceptable) quality level in the
cell (dB). Used to set cell border between two cells.
Unit: 1 dB
Resolution: 1
-24 : -24dB
......
0 : 0dB
100 : Indicates that the minimum quality level has not been specified by
the operator. The parameter is then not
present in SIB11 for this neighbour. The UE will use the serving cell
value (UtranCell MO value) instead.
Unit: 1 dBm
Resolution: 2
-115 : -115dBm
-113 : -113dBm
-111 : -111dBm
-109 : -109dBm
.....
-25 : -25 dBm
100 : Indicates that the minimum Rx level has not been specified by the
operator. The parameter is then not
present in SIB11 for this neighbour. The UE will use the serving cell
value (UtranCell MO value) instead.
Unit: 1 dB
Resolution: 2
Idle Mode Parameter Summary
sInterSearch The decision on when measurements on inter frequencies shall be
performed.
Unit: 2 dB
Resolution: 1
1 : not sent
2 : -32 dB
3 : -30 dB
...
27 : 20 dB
sIntraSearch The decision on when measurements on intra frequencies shall be
performed.
Unit: 2 dB
Resolution: 1
1 : not sent
2 : -32 dB
3 : -30 dB
...
27 : 20 dB
sRatSearch
The decision on when measurements on GSM frequencies shall be
performed is made using this parameter in relation with Squal.
If S_qual > this parameter, UE need not perform measurements on
GSM cells.
If S_qual <= this paramter, UE shall perform measurment on GSM
cells.
Unit: 1dB
Resolution: 2
-32 : -32dB
-30 : -30dB
......
Idle Mode Parameter Summary
treSelection Control of cell selection/reselection. Time-to-trigger for cell reselection
in seconds.
Note: the values 0000 and FFFE are reserved for special cases where
no valid LAI exists in the MS.