Overvoltage and
Monitoring logic
short circuit protection K1
24V K2 K1
K2
Power K2 K1
S21 14 24 34 42
L1 L1
Applications off
E-stop
on K4
E-stop
K5
A1(+) S11 S33 S34 S12 S22 13 23 ..
A1(+) S11 S33 S34 S12 S22 13 .. ..
LG5925
LG5925
.. .. A2(-) S21 14 24 ..
A2(-) S21 14
K4 K5
N
N
Single channel emergency stop circuit. This circuit does not have any Contact reinforcement by external contactors, 2-channel controlled.
redundancy in the emergency-stop control circuit. The output contacts can be reinforced by external contactors with positive
Note: Refer to "Unit programming" guided contacts for switching currents > 8 A.
Set switch or dip switch in pos.: S1 no cross fault detection Functioning of the external contactors is monitored by looping the N.C.
S2 automatic start contacts into the closing circuit (terminals S33-S34).
Note: Refer to "Unit programming"
Set switch or dip switch in pos.: S1 no cross fault detection
S2 manual start
L1 L1 L1
E-stop E-stop
on E-stop K4
on
K5
A1(+) S11 S33 S34 S12 S22 13 .. .. A1(+) S11 S33 S34 S12 S22 S21 13 .. .. A1(+) S11 S33 S34 S12 S22 13 .. ..
N N K4 K5
2-channel emergency stop circuit without 2-channel emergency stop circuit with N
cross fault monitoring. cross fault detection. Contact reinforcement by external contactors
Note: Refer to "Unit programming" Note: Refer to "Unit programming" controlled by one contact path.
Set switch or dip switch in pos.: Set switch or dip switch in pos.: Note: Refer to "Unit programming"
S1 no cross fault detection S1 cross fault detection Set switch or dip switch in pos.:
S2 manual start S2 manual start S1 no cross fault detection
(+ ) S2 automatic start
+ -
coded actuator
coded switch
L1
sliding guard closed 2-channel emergency stop circuit with cross fault.
- +
Contact reinforcement by external contactors.
on Two coded non-contact sensors in series.
-
LG5925 K4
On
- +
A2(-) S21 14 .. .. K5
A1(+) S11 S33 S34 S12 S22 S21 13 23 .. ..
N
Activated N.O. contact BG5920
(contact position: closed) t LG5925
S2:aufHandstar
A1(+) A2(-) 13 23 33 43 53 Y1
24V K1
24V K2
A3(+) A4(-) 14 24 34 44 54 Y2
Applications
L1
Emergency
Stop
LG5925
..
A2(-) S21 S33 S34 14 24
On
Y1 Y2 A1(+) A3(+) 13 23 33 43 53
LG5929/100
A2(-) A4(-) 14 24 34 44 54
N
Contact multiplication with LG 5929/100
Note: This is a representative drawing. Depending on the LG5925 safety relay you select, different voltage
sources may be required.
Safety Products
Warning: Safety products sold by AutomationDirect are Safety components only. The purchaser/installer is solely responsible for the application of these components and
ensuring all necessary steps have been taken to assure each application and use meets all performance and applicable safety requirements and/or local, national and/or
international safety codes as required by the application. AutomationDirect cannot certify that our products, used solely or in conjunction with other AutomationDirect
or other vendors’ products, will assure safety for any application. Any person using or applying any products sold by AutomationDirect is responsible for learning the
safety requirements for their individual application and applying them, and therefore assumes all risks, and accepts full and complete responsibility, for the selection and
suitability of the product for their respective application.
AutomationDirect does not provide design or consulting services, and cannot advise whether any specific application or use of our products would ensure compliance
with the safety requirements for any application.