You are on page 1of 1

Scope of works & Required Submittals Date Input Drawings No

Roof Canopy Roof Canopy


1.Submit Design Basis report,Design of Roof Canopy using Staad pro(Ensuring Serciveability & Check Utilization ratio for limit
state for replaced members).
Note: Decide erection splice location if required. A360_FACADE DETAILS-06(3D VIEWS)
2.submit Detailed member design document and Connection Design document with Ideastatica files.
Note: Recheck the Base plate and anchor bolt requirement from the drawings submitted by client as the pedestal and anchor bolt was A361-FACADE DETAILS-06(ENLARGED PLAN,ELEVATIOS &
already casted in site . SECTIONS
3.Submit Engineering Drawings. S906-STEEL CANOPY AND DETAILS-SHEET 4 OF 4

4.Submit Detailed Erection Engineering document(Detailed Splice design,Erections cleat and lifting Lugs designs,if required).
5.Submit Erection Engineering drawings.
6.Submit fabrication drawings with BOQ.

North Canopy North Canopy


1.Submit Design Basis report,Design of North Canopy using Staad pro(Ensuring Serciveability & Check Utilization ratio for limit
state for replaced members).
Note: Decide erection splice location if required. A370-FACADE DETAILS-10(3D VIEWS)
2.Submit Detailed member design document and Connection Design document with Ideastatica files. A371-FACADE DETAILS-10(ENLARGED PLANS &
ELEVATIONS)
A372-FACADE DETAILS-10(ENLARGED PLANS &
3.Submit Engineering Drawings. SECTIONS)
4.Submit Detailed Erection Engineering document(Detailed Splice design,Erections cleat and lifting Lugs designs,if required). S903-STEEL CANOPY AND DETAILS-SHEET 1 OF 4
5.Submit Erection Engineering drawings.
6.Submit fabrication drawings with BOQ.

East Canopy
1.Submit Design Basis report,Design of East Canopy using Staad pro(Ensuring Serciveability & Check Utilization ratio for limit
state for replaced members).
Note: Decide erection splice location if required.
2.Submit Detailed member design document and Connection Design document with Ideastatica files/Design of pedestal. Will be updated soon
3.Submit Engineering Drawings.
4.Submit Detailed Erection Engineering document(Detailed Splice design,Erections cleat and lifting Lugs designs,if required).
5.Submit Erection Engineering drawings.
6.Submit fabrication drawings with BOQ.

West Canopy
1.Submit Design Basis report,Design of West Canopy with cable analysis using Staad pro(Ensuring Serciveability & Check
Utilization ratio for limit state for replaced members).
Note: Decide erection splice location if required.
2.Submit Detailed member design document and Connection Design document with Ideastatica files. Will be updated soon
3.Submit Engineering Drawings.
4.Submit Detailed Erection Engineering document(Detailed Splice design,Erections cleat and lifting Lugs designs,if required).
5.Submit Erection Engineering drawings.
6.Submit fabrication drawings with BOQ.

Glass Balustrade Glass Balustrade


1.Submit Design Basis report,Create staad model for balustrade with U-chanel and apply corresponding loads. 17.52mm (8mm glass +1.52 film +8mm glass) laminated glass
2.Check the bearing capacity ,shear resistance of U chanel and bolt. U-Chanel Aluminium: 4cm x 12.5cm x 10mm thick
Bolt: M10,Grade 4.8