Professional Documents
Culture Documents
SNG21F037717 Oa
SNG21F037717 Oa
Final Report
This report replaces our preliminary report of 08-Oct-2021
Operational
Based on the Total Sediment, it is recommended not to use this fuel. Please refer to the
comments in this report
Test Results
Unit Test Results RMG380 Test Method
Density @ 15°C kg/m3 942.9 991.0 ASTM D7042
Viscosity @ 50°C mm2/s 111.6 380.0 ASTM D7042
Water %V/V 0.40 0.50 ASTM D6304-C
Micro Carbon Residue %m/m 7.20 18.00 ISO 10370
Total Sediment Potential² %m/m 0.17 0.10 ISO 10307-2
Ash %m/m 0.06 0.10 LP 1001
Vanadium mg/kg 15 350 IP 501
Sodium mg/kg 61 100 IP 501
Calcium mg/kg 33 30 IP 501
Zinc mg/kg 2 15 IP 501
Phosphorus mg/kg 2 15 IP 501
Pour Point degC 18 30 LP 1306
Flash Point degC > 70.0 60.0 ISO 2719-B
CCAI (Ignition Quality)¹ - 818 870 ISO 8217
Aluminium + Silicon mg/kg 41 60
Acid Number mg KOH/g 0.1 2.5 ASTM D664
Total Sediment Existent² %m/m 0.12 ISO 10307-1
Total Sediment Accelerated %m/m 0.32 ISO 10307-2
²
Aluminium mg/kg 18 IP 501
Silicon mg/kg 23 IP 501
Iron mg/kg 22 IP 501
Nickel mg/kg 21 IP 501
Magnesium mg/kg 4 LP 1101
Potassium mg/kg 3 LP 1101
Net Specific Energy¹ MJ/kg 41.50 ISO 8217
GC/MS Screen Headspace - Pass LP 3404-Headspace
Screen
¹ Calculated value; ² Retested parameters
Operational Advice
Total Sediment Fuel stability is suspect and increased sludging is likely to occur in all
tanks, e.g. bunker tanks, settling and service tanks, which will result in
operational problems with separators and filters. The use of this fuel is
therefore not recommended. Do not mix with another fuel and avoid
prolonged storage at high temperatures. Consider to inspect bunker
tanks for excessive sludge build-up for next bunkering.
System samples Representative tank samples should be collected from each tank where
the fuel has been stored and should be sent at first opportunity for
testing in order to assess the current conditions.
Note
2 SNG21F037717
GLOVIS MELODY (9607007)
Best Regards,
On behalf of Veritas Petroleum Services BV
Thasneem Ali
Assistant Technical Support Engineer
For assistance or further information on this report please contact your nearest VPS office or contact us
directly at Tel : +31 (0) 180 221100, Email : Tech.Rot@vpsveritas.com
3 SNG21F037717