Engine Specs
Type : DEUTZ BF8M1015CP (G3)
Power Output Genset [COP/PRP/LTP] : 451kVA / 504kVA / 553kVA
Speed [Rpm] / Frequency [Hz] : 1500 / 50
No of cylinders : 8 (V)
Displacement [l] : 16
Bore/Stroke [mm] : 132 / 145
Governor : Electronic Engine Governor (EMR)
Compression Ratio : 16.5 : 1
Cooling System : Water Cooling
Fuel Consumption [l/h] : 118 (100% Load, PRP)
Oil Capacity [l] : 45
Alternator Specs
Type [3 Phases, Single Bearing] : STAMFORD / LEROY SOMER / PRIME
Speed [Rpm] / Frequency [Hz] : 1500 / 50
Voltage [V] : 400
Insulation : Class H
Protection : IP 23
Accessories
Batteries : 24Volts,
: Set of Connection cables and Cable terminals
Coolant Capacity [l] : 116 (incl. Cooling unit)
Exhaust System : Industrial exhaust silencer
Baseframe : Steel Channel construction (include daily tank
for 8hrs operation)
Engine and Alternator Mounting : Rubber metal elements
Set of Operation books, consist of : Engine operating instruction
: Certificate of Origin
: Alternator operating instruction
: Genset Test Report
Control Panel
DeepSea 7320, Key features : 3-phase generator and mains (utility) sensing
: Power monitoring (kW h, kV Ar, kV Ah, kV Ar h)
: Remote communications (RS232 & RS485)
: Configurable inputs/outputs (9/8)
: Fuel usage monitor and low level alarms
: Manual/automatic load transfer
: Power save mode
: DSE Configuration Suite PC Software
: Etc
According to ISO 8528-5. Continuous Power: No time limitation, plus 10% addictional, power for governing purpose only. Prime Power: Average output ≤ 80%, no time limitation, plus 5%
addictional power for governing purpose only. Limited Time Running Power: for up to 500 h/year, thereof a maximum of 300 h/year continuous running. In consideration of a generator
efficiency level of 89% - 90% and a power factor of 0.8