795X liquid flow computers

for the oil and refined products industry

F1

Remote Automation Solutions


For complete metering control:

Features
• Measurement of up to four • Compatibility with most
independent meter runs and flowmeters and inputs for
The 795X liquid flow computer proving in one flow computer density, temperature,
• Easy to set-up & commission pressure, viscosity and water
range is suitable for metering
• Intelligent PC configuration cut
a variety of hydrocarbon
tool • Compensated flow rate and
liquids in demanding fiscal and • Simple system integration totals including gross
custody transfer applications. with adaptable volume, gross standard
Two versions are available communications software volume, mass and net oil (in
and build on the success of • Flexible software - user accordance with (API 21.2)
selection of engineering units, • Comprehensive on board
the previous Solartron flow
base conditions etc. logging and batching
computers.
• Hot duty standby - fully facilities
• The 2510 liquid flow redundant system with
computer software - is suitable multistream flow computers

for single stream applications,


with or without proving, and Applications
runs on the 7951 hardware • Liquid metering to fiscal requirements
platform (see X301463X412 for • Custody transfer
details) • Tanker loading
• Sales metering
• The 2540 Multistream liquid • Pipeline distribution
flow computer software - can • Allocation metering
measure up to 4 streams • Product interface detection
• Meter proving
(meter runs) and a prover and
runs on the 7955 hardware
platform (see D301462X412 Cost effective multi-stream monitoring
for details). and control
The 2540 flow computer software can monitor up to four metering
runs/streams on the 7955 platform and handles both types of
commonly encountered flow schemes: 4x4x4 and 1x4x1.
In the 4x4x4 scheme the meter runs are completely independent,
each with its own flowmeter and associated instrumentation
(typically pressure, temperature, density and viscosity). The fluid can
be common, or may be different in each meter run.

The 1x4x1 scheme shown opposite, has a single common inlet header
which divides into 4 meter runs, each having its own flowmeter,
pressure and temperature measurement. The common inlet header
typically has on-line density and/or viscosity measurement, which
can be referred to meter run conditions, using either API/ASTM or 4x5
matrix referral, all under the control of the flow computer.
Single and Multi-stream liquid flow computers

Hot duty/standby
A complete redundancy
solution in multistream flow
measurement applications, hot
duty/standby allows two 7955
multistream flow computers to
work together to give a fiscally
secure measurement solution
with in-built redundancy in the
flow computers, with all of the
advantages of multistream flow
computers.

Hot duty standby allows full


redundancy to be built in to
the metering system using two
7955 flow computers for up to
four meter runs, and is ideal for
both fiscal and custody transfer
metering applications.

The two 7955 flow computers


work together to maintain
traceable daily reports and
batches, including PID control,
even if one flow computer should
malfunction or lose power.

Critical data such as batch ticket


numbers, PID set points, valve
status and batch quantities are
frequently synchronised across
the two flow computers using
a Peer to Peer link. There is also
an option to use an encrypted
password to allow the totalisers
of each flow computer to
synchronise with each other, thus
giving a seamless audit trail.

This practice is becoming


more acceptable worldwide,
particularly as even in the event
of a flow computer failure, the
accuracy and integrity of the flow
data is maintained without losing
any flow.

The schematic above shows a typical 4 meter run metering station. Here one flow The system is highly efficient,
computer could be used for all instrumentation including the prover. For critical accurate, and particularly cost
applications the redundancy offered by hot duty/standby is often preferred. effective for metering systems
with many metering points.

Features

• All common engineering units for Report generation and


parameters such as temperature,
logging
pressure, density, viscosity, flow, etc.
• These options cover metric units, imperial Comprehensive report generation
facilities are an integral part of the
/ English units or S.I. units. All are user
25X0 liquid flow computer. Standard
selectable, including both US and reports include a complete listing
UK gallons of configuration data, an alarm report, F1

• Displayed units and units used over a prover report and a listing of auditable
communications ports are site selectable events, which shows any critical changes
• The conditions to which base or reference made to the operation of the flow computer, such as flow and
calibration parameters.
volumes and densities are referred to are
In addition, user-defined reports can be created to generate listings
also site configurable e.g. 1013.25mBar, of specified data manually or at pre-determined intervals. All 25X0
14.7 psi, 0°C, 15°C, 20°C or 60°F liquid flow computer reports can be printed or downloaded when
• Support for turbine, ultrasonic, positive required.
displacement, Coriolis, orifice and Venturi
flow meters Transactions and batching
• Support for uni-directional, bi-directional
The 25X0 software generates and logs records - often known as
pipe provers, compact provers and master batch records or quantity transaction records (QTRs) -
meter provers of flow totals and other operating details. These can be initiated
All other features are built in to the by a variety of methods, giving total control over their generation,
standard 25X0 liquid software, including and enabling flow total for each shift or day to be recorded. Flow of
individual products can be tracked and even batched into defined
hot duty standby, viscosity measurement,
quantities, if required.
batching, reports, PID control, product
Time: A new batch is triggered automatically, typically every hour,
detection. shift or day.
Manual: Batches are triggered and stopped manually on demand
Should gas measurement be required
from the keypad or via a remote comms input.
please ask for data sheet D351485X412. Product: With automatic product detection enabled, whenever the
product changes, the current batch is completed, and a new one
started.
Quantity: Each time a batch quantity (set by the user) is reached, a
batch report is produced and the flow can be stopped. This facility
allows fluids to be batched by volume or mass.
Daily batch: a new batch is triggered automatically when the
‘contract hour’ is reached.

PID flow delivery control: this is available to either control the flow
delivery rate on each individual stream, or it can be used to maintain
the flow rate across the metering station, balancing the flow across
the optimum number of meter runs.

Net oil and water calculations


Net calculations for oil and water can be handled in either of the
following ways:
Simple method: - as per API - with an input for water cut, here the
complete mixture undergoes an API referral.
Detailed method: typically with knowledge of the water base
density - the oil and water components are split and each undergoes
separate density referrals.
Configuration and
operation
The ease and simplicity of
configuration with any flow
computer is often equally as
important as the functionality of
the software. With the 795X range
Proving of flow computers there are several
options.
To complement its outstanding flow measurement
capabilities, each 795X can provide full prover control The basic menu structure: this
for most common types of prover, including uni & is laid out to allow quick and
bi-directional pipe provers, compact provers and even logical access to all operational
master meter provers. The flexible software allows and diagnostic parameters, with
flow meters, particularly Coriolis meters, to be proved navigation between streams.
on a volume or mass basis. There are also dedicated menus
for configuration, datalogging and
Built-in reliability archives.

The 25X0 software internal database is continually The Multiview facility: allows the
updated from input channels. Measurement critical setup of user defined display
data is stored in non-volatile memory, and is pages. These can be configured
triplicated and cross-validated to ensure data remains to group together all information
uncorrupted. required on a regular basis for
simple operator access. These
FC_BASIC parameters and the text can be
modified by the user to their own
FC_BASIC is a powerful tool that allows the standard
preference.
application software to be customized to satisfy the
individual site requirements, without the need to PC _Config: is an intelligent
issue special application software. windows based configuration
‘BASIC’ routines can be quickly written to interface to tool, please see following page for
the flow computer database and carry out a selection details.
of special logic functions or scientific calculations.

Typical uses of FC_BASIC are :-


• Grab sampler control Compatible flow
• Product detection meters
based on viscosity
rather than density
• Turbines -
single or dual pulse
• Positive displacement
meters
• Coriolis - mass or volume
• Ultrasonic time of flight
• Differential pressure
∙ Orifice ∙ Venturi
∙ Dall tube ∙ V-Cone
Improved measurement uncertainty and flowmeter
performance enhancement
Built-in facilities in the 7951 and Universal calibration curve: as per
7955 flow computers significantly ISO 4124. Allows the flow computer
improve flow measurement to continually update the K-factor
uncertainty (essential for custody of each flow meter depending
transfer applications) and also upon the fluid viscosity and the
give improved product quality and meter frequency. This method is
reduced wastage. particularly suitable for turbine
meters where the fluid viscosity is
Pulse Integrity : With pulsed
continually changing due to fluid
output type flow meters, e.g.
composition and/or temperature.
turbine meters, PD meters and
some Coriolis or ultrasonic meters, Viscosity compensation: The 25X0
the integrity of pulses received by software can accept up to four
the flow computer is paramount. calibration curves to compensate
The 795X includes pulse integrity for the effect of different viscosities
checking to the highest level on flowmeter performance.
achievable – it meets the standard Alternatively, unique calibration
of ‘Level A’ as specified in IP data for each product can be
252/76 & API Ch 5.5. entered for each flow meter,
optimising the performance for
Analog Inputs : With flow meters
each product.
or transmitters that use an
analog output, the accuracy and
resolution of the receiving flow Automatic product
computer’s analog to digital
(A/D) converter is critical to
detection
accurate measurement. The The 25X0 liquid software
795X incorporates a 20 Bit A/D recognises - by density or specific
converter for resolution of better gravity - up to 20 different fluid
than 1 part per million. products flowing through any of
the metering runs. On detection,
Intelligent Transmitter : The 25X0
products can be automatically
software is also compatible with
diverted to the relevant line or tank
intelligent transmitters and
in the plant. Each named product
flowmeters, differential pressures,
has its own dedicated totalisers and
pressures, temperatures and
unique flowmeter calibration data,
densities can be read using HART
which can be invoked automatically
protocol or the flow computer
to ensure optimum accuracy and
can communicate with intelligent
quality control.
transmitters or flowmeters
The 25X0 software can generate
using Modbus commands to
individual product batch reports
read process variables as well as
when the product flowing in the
valuable diagnostic data.
meter run changes. These reports
Linearisation : The 25X0 software log all operating parameters and
stores a 10-point linearisation flow totals for a particular product
curve for correcting the inherent and provide an audit trail.
non-linearity of flowmeters,
particularly turbines and Venturi
tubes.
Point and click PC based configuration
• Configuration made easy
• Point and click based
• Dramatic reductions in time and skill set required
• Easy to operate graphical interface
• Set-up wizards

PC_Config
PC_Config is an intelligent With PC_Config the configuration The 795X supports the following
Windows PC based software tool is typically completed in an Modbus commands
that makes dramatic reductions in office environment and simply • 03 Read holding registers
the time required for configuration downloaded on to the flow • 16 Write / preset multiple
of flow computers in fiscal and computer when it is ready. Edits registers
custody transfer applications. PC_ are automatically time and date
The use of ‘High Speed Lists’
Config allows engineers to set up stamped to provide an audit
enables all critical parameters
complete flowmetering systems in trail and there is a built-in
to be grouped together within
a fraction of the time traditionally reports function for automatic
single database lists, in any order.
required for the task. documentation of the process.
This grouping then allows the use
PC_Config makes the task of In addition, the PC_Config features of more efficient multiple read
configuring both single and a virtual flow computer front panel and multiple write commands,
multistream flow computers which can be used on-line for live rather than individual locations.
much simpler and the graphical remote control of the flow These High Speed Lists lists can be
interface makes it easy to operate. computer, for trouble shooting and positioned anywhere within the
‘Point-and-click’ icons are used diagnostics, or off-line for training 0001 to 65,000 Modbus range for
to assemble a measurement task purposes. maximum compatibility.
diagram and to identify measure-
ment and alarm points, batching, Communications The process variables and other
values that are transmitted via the
proving and logging functions.
The 795X has been specifically communications ports can be in
The software then calls on its built-
designed to simplify integration user defined engineering units,
in instrument set-up wizards to
into supervisory systems and (metric, imperial/English, US, SI,
create a database showing exactly
networks. It has up to five RS232 or a mixture) further simplifying
what information is required
and RS485 serial ports supporting integration.
for the chosen measurement
MODBUS (ASCII & RTU, IEEE 32 bit
task: alarm limits, failure modes,
and IEEE 64 bit data) as well as an
communications options, prover
independent ethernet port support-
details, batching, logging etc.
ing Modbus over TCP/IP. Any of the
With basic metering principles the
5 serial communications ports can
engineer or technician simply fills
be configured on site to be a slave,
in the blanks.
master, printer driver or peer.
Further information
The 795X liquid flow computer range is based on the successful 795X hardware platform, for specific details ask for
technical bulletins:

D301463X412 7951 Specification sheets


D301462X412 7955 Specification sheets
D351485X412 795X Flow computer for gas applications

Outline functional specification


Calculates Indicated volume rate and total
Gross volume rate and total
Net volume rate and total
Indicated standard volume rate and total
Net standard volume rate and total
Mass rate and total
Net mass rate and total
Line density: - direct measurement or referral from header using API or matrix referral
Base density: - API or matrix referral
Conforms to ASTM D 1250-04 / IP 200/04 / API MPMS Chapter 11 Section 1 2004
API 2540 / API 11.1 1980 (Tables 53A/B,54A/B),
API 11.2.1M, API 11.2.2M, API 21.2
Monitors, trends
& alarm checks: Temperature, pressure, density, base density, viscosity, base viscosity and BS&W
Batch transactions: Manual, time-based, daily, product-based, or quantity-based
Alarms: System; input; limit.
All alarms and significant events are logged to facilitate an audit trail
Prover control: Support for master meter, compact and uni- or bi-directional pipe provers
Security: Via keyswitch or three password levels
Logging & reports: Pre-formatted reports containing fixed and user selected data
User-configurable reports

Bristol, Inc., Bristol Canada, BBI SA de CV, the Flow Computer Division, and Emerson Process Management Ltd, Remote Automation Solutions division (UK) , are
wholly owned subsidiaries of Emerson Electric Co. doing business as Remote Automation Solutions (“RAS”), a division of Emerson Process Management. FloBoss,
ROCLINK, Bristol, Bristol Babcock, ControlWave, TeleFlow and Helicoid are trademarks of RAS. AMS, PlantWeb and the PlantWeb logo are marks of Emerson Electric
Co. The Emerson logo is a trademark and service mark of the Emerson Electric Co. All other marks are property of their respective owners.

The contents of this publication are presented for informational purposes only. While every effort has been made to ensure informational accuracy, they are not to be
construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. RAS reserves the right to
modify or improve the designs or specifications of such products at any time without notice. All sales are governed by RAS’ terms and conditions which are available
upon request. RAS does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of
any RAS product remains solely with the purchaser and end-user. © June 2008 Remote Automation Solutions, All rights reserved.

Emerson Process Management


Remote Automation Solutions
Outgang Lane, Pickering,
North Yorkshire, YO18 7JA, UK
Tel: +44 (0)1751 471800
Fax: +44 (0)1751 471801
e-mail: sales.rasema@emersonprocess.com
www.emersonprocess.com/remote/

Literature reference number: D351484X412 June 2008