MC-1000BA-T-50008 - Piping Wall Thickness Calculation (Port) (Rev.0')
MC-1000BA-T-50008 - Piping Wall Thickness Calculation (Port) (Rev.0')
- 0
REVISIONS
IT: ISSUE A - PRELIMINARY C - FOR E - FOR CONSTRUCTION G - AS BUILT
TYPE B - FOR APPROVAL INFORMATION F - AS PURCHASED H - CANCELED
D - FOR
QUOTATION
- 0
TABLE OF CONTENTS
1 PURPOSE 3
2 APPLICATION 4
3 REFERENCE DOCUMENTS 5
4 CODES AND STANDARDS 5
5 DEFINITIONS 8
6 METHODOLOGY 9
7 DESIGN DATA 9
7.1 PROCESS DATA 9
7.2 PIPE MECHANICAL DATA 10
7.3 QUALITY FACTOR (E) 10
7.4 WELD JOINT STRENGTH REDUCTION FACTOR (W) 10
7.5 COEFFICIENT REGARDING TEMPERATURE FACTOR (Y) 10
7.6 MILL TOLERANCE 10
8 CALCULATION RESULT 10
8.1 CLASS C1A 101
8.2 CLASS C1D 11
8.3 CLASS C1F 11
8.4 CLASS C1H 11
8.5 CLASS C1K 11
CLASSIFICATION
Internal Use INDONESIA GROWTH
PROGRAM (IGP) G801520
- 0
1 PURPOSE
The purpose of this scope document is to outline the overall basic engineering design data
for EPC Contractor’s design, procurement, construction and commissioning responsibilities
for EPC Contract at the PT Vale Indonesia (PTVI) Bahodopi site. The basic engineering
design data is as described in Section 6.0 Design Data and associated documents and
drawings.
The following terminology is defined for use in this project:
• Project Design Criteria – defines the overall requirements for the project.
For example, units and abbreviations, site location, environmental
conditions, planned life of mine and annual production rates, required ore
grade, etc.
• Area Design Basis - would typically form part of the overall project design
basis document; however, has been separated to enable design relating to
different scope areas (mine, mine infrastructure and the facilities/utilities) to
proceed independently. These documents describe “functional
requirements” and key assumptions.
- Mine Design Basis - defines the assumed basis that will be used for
the mine (prepared by GE21 and agreed with PT Vale).
- Mine Infrastructure Design Basis - defines the assumed basis that will
be used for the mine infrastructure basic engineering (to be agreed
with PT Vale, and mine plan received from GE21.
- 0
2 APPLICATION
The Mines of Bahodopi Block 2-3 (MBB2-3) project will supply saprolite ore to an ore port
within the Bahodopi area, for barging to a Ferronickel (FeNi) plant located at a coastal
location on Sulawesi, Indonesia.
• Saprolite Ore Port (both offshore and onshore scope) and interconnecting
road between Port to Mine.
• Quarry Development.
CLASSIFICATION
Internal Use INDONESIA GROWTH
PROGRAM (IGP) G801520
- 0
PT Vale will own and operate the mine within the Bahodopi concession. The FeNi plant and
associated receiving port will be operated by a separate Joint Venture (JV) and are excluded
from the MBB2-3 project scope.
This document covers the basic engineering design data of the mine infrastructure, including
main haul roads, stockpiles, and ex-pit water treatment. The objective of the document is to
clearly define PT Vale’s criteria to be used as part of the engineering design and to ensure
uniformity and consistency of the design.
3 REFERENCE DOCUMENTS
Documents listed below have been used in developing this document or include instructions
and procedures applicable to it. They shall be used in their latest revision.
GENERAL
All work performed and all materials furnished under the Project shall conform to the latest
revision, addenda and supplements of all relevant approved Indonesia, national and
international standards and the relevant government acts, codes and regulations of the
statutory authorities having jurisdiction over this facility at the time of the signing of the
contract.
Work shall conform to PTVI safety standards, reference drawings and any other documents
as nominated in the discipline design criteria documents referenced in this document. All
documents shall be used in their latest revision.
CLASSIFICATION
Internal Use INDONESIA GROWTH
PROGRAM (IGP) G801520
- 0
The EPC Contractor have responsibility for identifying all applicable Indonesian standards
and regulations. Where Indonesian standards, codes and regulations do not exist, those of
the International standard shall apply, Subject to company approval.
The following standard for piping design criteria are referred in this project :
ASME (American Society of Mechanical Engineers)
ASME B16.20 Metallic Gasket for Pipe Flanges Ring-Joint, Spiral-Wound, and
Jacketed
Vale S.A. have established new Normative Technical Standards (PNRs) that establish
guidelines and minimum safety and integrity requirements relating to critical assets, that
must
be applied to new projects. Relevant PNR documents are referenced in each of the
discipline design criteria documents.
The Vale Technical Specifications (SPEs) referenced in each of the discipline Design
Criteria documents contain some requirements which are not normal in Indonesia, for
example references to Brazilian national standards (NBRs) and regulations.
CLASSIFICATION
Internal Use INDONESIA GROWTH
PROGRAM (IGP) G801520
- 0
The EPC Contractor confirm all designs are compliant with local Indonesian standards,
codes, and regulations.
The EPC Contractor may request approval for additional exceptions provided that each
exception complies with all the following requirements:
• The exception does not reduce the performance, safety, or durability of the
works
The EPC Contractor will submit requests for additional exceptions to the SPE’s in writing to
the Company. The affected clause and the proposed alternative requirements shall be
clearly identified in the request.
The Company shall respond to such requests in writing within 10 working days. Requests
for approval of exceptions meeting the above requirements shall not be unreasonably
refused.
CLASSIFICATION
Internal Use INDONESIA GROWTH
PROGRAM (IGP) G801520
- 0
5 DEFINITIONS
Critical Assets
PP PT PP (persero) Tbk.
TBC To be confirmed
TBD To be determined
- 0
6 METHODOLOGY
Wall thickness calculation is performed under code and standard for Process Piping,
ASME B31.3. Based on the code the equation for wall thickness calculation is stated
below.
𝑃×𝐷
𝑡= ............................................................................................... (Equation 6.2)
2((𝑆×𝐸×𝑊)+(𝑃×𝑌))
where:
tm : Required minimum thickness
t : Pressure design thickness
c : Corrosion Allowance
P : Internal pressure
D : Outside Diameter
S : Stress Value (from Table A-1A dari ASME B31.3)
E : Quality Factor (from Table A-1A or A-1B dari ASME B31.3)
W : Weld Joint Atrength Reduction Factor (paragraph
302.3.5(e))
Y : Coefficient from table 304.1.1 untuk t<D/6, this value (Y) is
obtained from by interpolation for intermediate temperature.
7 DESIGN DATA
Material Class
Parameter Unit
C1A C1D C1F C1H C1K
Class Rating 125# 150# 150# 150# 150# -
Design (KPag)/
1400/14.28 1863/19.2 1500/15.29 1792/18.28 1863/19.2
Pressure (kg/cm2)
Design ℃
60 60 60 79.9 60
Temperature
Corrosion
1.6 (0.062) 1.6 (0.062) 1.6 (0.062) 1.6 (0.062) 1.6 (0.062) mm (Inch)
Allowance
CLASSIFICATION
Internal Use INDONESIA GROWTH
PROGRAM (IGP) G801520
- 0
Weld joint strength joint factoris taken from table 302.3.5, ASME B31.3
Description E
Seamless (S) 1
Electric resistance welded pipe (E) 0.85
Electric Fusion Welded 0.8
the coefficient value is taken from table 304.1.1 ASME B31.3 for t<d/6, with temp. less than
482 0f is 0.4.
8 CALCULATION RESULT
- 0
- 0
ATTACHMENT A
WALL THICKNESS CALCULATION CLASS C1A
Note :
Data input is refer to document "LI-2000BA-P-5406" line list Rev.0
CLASSIFICATION
Internal Use INDONESIA GROWTH
PROGRAM (IGP) G801520
- 0
ATTACHMENT B
WALL THICKNESS CALCULATION CLASS C1D
Note :
Data input is refer to document "LI-2000BA-P-5406" line list Rev.0
CLASSIFICATION
Internal Use INDONESIA GROWTH
PROGRAM (IGP) G801520
- 0
ATTACHMENT C
WALL THICKNESS CALCULATION CLASS C1F
Note :
Data input is refer to document "LI-2000BA-P-5406" line list Rev.0
CLASSIFICATION
Internal Use INDONESIA GROWTH
PROGRAM (IGP) G801520
- 0
ATTACHMENT D
WALL THICKNESS CALCULATION CLASS C1H
Note :
Data input is refer to document "LI-2000BA-P-5406" line list Rev.0
CLASSIFICATION
Internal Use INDONESIA GROWTH
PROGRAM (IGP) G801520
- 0
ATTACHMENT E
WALL THICKNESS CALCULATION CLASS C1K
Note :
Data input is refer to document "LI-2000BA-P-5406" line list Rev.0