You are on page 1of 3

S I M D D D C

Z
N O E H
R
H D D O A S E
E I A
E X F W I C
N T G
OI N K
E R C E E N E
R A E D
T E T B D
V I Y
B B
O
N Y Y

36974R

Singapore, 15-Jul-2020

NOTE :
PANEL MAKER SHOULD FOLLOW PHASE LINE R-T-S

HULL NO.
PROJECT NAME
KMC 38 M 400
DRAWING /DOCUMENT NAME
YEAR 2020 DATE

DRAWN BY 25/06
BATTERY CALCULATION
OWNER
CHECKED BY 25/06 CLASS BV

KEMHAN
APPROVED BY 25/06 SCALE -

BUILDER
SIZE A4
ALL RIGHTS RESERVED

SHEET 01 of 02

PROJECTION SYMBOL DRW/DOCUMENT NO. :

400YE029
REV. 0 1 2
BUREAU VERITAS
Stamped document, refer to 1st page

CAPACITY CALCULATION FOR NAVIGATION BATTERY'S GROUP


CALCULATION FORMULA

Q= ∑.P.T
U.K

Q= CAPACITY OF BATTTERIES (Ah)


P= TOTAL POWER OF ALL LOAD (W)
t= TIME (h)
u= VOLTAGE (V)
k= FACTOR OF CAPACITY

LOAD FEED FROM BATTERY IN NAVIGATION

RATE FACTOR OF POWER


NAME OF DEVICE SYSTEM POWER TIME (H) CAPACITY CONSUMPTION (
N0 (W) (k) Q=Ah )

1 GYRO REPEATER 240 4 1 40


2 AUTO PILOT 240 4 0.8 32
3 GPS 168 4 0.8 22
4 MAGNETIC COMPASS 168 4 0.6 17
5 SPEED LOG 240 4 1 40
6 ECHOSOUNDER 240 4 0.6 24
7 WEATHER SYSTEM 240 4 0.6 24
8 WEATHER FACSIMILE 168 4 0.6 17
9 AIS 240 4 0.8 32
10 BNWAS 168 4 1 28
11 RAI INDICATOR 72 4 1 12
TOTAL 288
BATTERY SELECTION: THEBATTERY GROUPS OF VESSEL CONSIST OF 1 GROUPS
OF ACCU BATTERIES , EACH GROUP OF 2 BATTERIES, SERIES IT'S CAPACITY IS 24V
200 Ah. IN GENERAL GROUPS ARE AT FLOATING CHARGING

CAPACITY CALCULATION FOR RADIO BATTERY'S GROUP


CALCULATION FORMULA

Q= ∑.I.T
K

Q= CAPACITY OF BATTTERIES (Ah)


I= TOTAL POWER OF ALL LOAD (A)
T= TIME (h)
k= FACTOR OF CAPACITY
BUREAU VERITAS
Stamped document, refer to 1st page
LOAD FEED FROM BATTERY IN RADIO COMMUNICATION

RATE POWER
NAME OF DEVICE SYSTEM POWER TIME (H) FACTOR OF CONSUMPTI
N0 (I) CAPACITY (k) ON ( Q=Ah )

1 MF/HF 500 W
2 MF/HF 150 W
GMDSS 63 4 1 252
3 NAVTEX
4 GMDSS SYSTEM
4 PUBLIC ADDRESSOR 200W 8.34 4 0.6 33
5 AUTO TELPHONE 3.3 4 1 13
TOTAL 299
BATTERY SELECTION: THEBATTERY GROUPS OF VESSEL CONSIST OF 2 GROUPS OF ACCU
BATTERIES , EACH GROUP OF 2 BATTERIES, SERIES IT'S CAPACITY IS 24V 200 Ah. IN GENERAL
GROUPS ARE AT FLOATING CHARGING
`

CAPACITY CALCULATION FOR GENERAL BATTERY'S GROUP


CALCULATION FORMULA

Q= ∑.P.T
U.K

Q= CAPACITY OF BATTTERIES (Ah)


P= TOTAL POWER OF ALL LOAD (W)
t= TIME (h)
u= VOLTAGE (V)
k= FACTOR OF CAPACITY

LOAD FEED FROM BATTERY IN GENERAL

RATE FACTOR OF POWER


NAME OF DEVICE SYSTEM POWER TIME (H) CAPACITY CONSUMPTION (
N0 (W) (k) Q=Ah )

1 EMERGENCY LIGHT 842 18 1 632


2 FIRE ALARM 70 1 0.4 1
3 GENERAL ALARM 70 1 0.4 1
4 NAVIGATION LIGHT 300 1 0.4 5
5 ENGINE TELEGRAPH 100 1 0.4 2
6 MSB 24VDC SOUCE 100 0.5 0.4 1
7 ESB 24VDC SOUCE 100 0.5 0.4 1
TOTAL 642
BATTERY SELECTION: THEBATTERY GROUPS OF VESSEL CONSIST OF 1 GROUPS
OF ACCU BATTERIES , EACH GROUP OF 2 BATTERIES, SERIES IT'S CAPACITY IS 24V
400 Ah. IN GENERAL GROUPS ARE AT FLOATING CHARGING

You might also like