You are on page 1of 1

Performance Management Areas

2.2 Hardware Use Counters


This section describes the following hardware use counters:

• pmSetupAttemptsSf4–256

• pmSetupFailuresSf4–256

• pmNoOfRadioLinks4–256

2.2.1 Setup Attempts and Setup Failures pm Counters


Separate counters exist for uplink and downlink. Figure 2 shows a flowchart
for the uplink counters.

GP start

No
Setup initiated?

Yes

UplinkBaseBandPool_pmSetupAttemptsSf<4..256>* +

No
Setup failed?

Yes
UplinkBaseBandPool_pmSetupFailuresSf<4..256>* +

Yes
End of GP?

Report
No

End

*) Counters are named Sf4, Sf8, Sf16, Sf32, Sf64, Sf128, or Sf256
P017440A

Figure 2 Uplink Setup Attempts and Setup Failures

Figure 3 shows a flowchart for the downlink counters.

8/1551-LZA 701 6003 Uen A | 2009-05-25 5