Test Plugs
After a casing head or spool and Blow Out Preventers, (BOP), have been installed on a well a pressure integrity test for these items must be conducted. In order for the test to
take place, a test plug should be set in the casing head or spool.
• A BOP test plug can be installed by running it down through the BOP stack and landing it on the load shoulder in the head
• The test plug is usually run on a joint of drill pipe
• Once in place the hydraulic rams of the BOP can be closed on the pipe and a hydrostatic test performed
• This will insure the integrity of the well control equipment prior to the restart of drilling operations