Load cell en
PD 21, PD 22, PD 23, PD 25
1. Safety 2
2. Function 2
2.1 Intended usage 2
2.2 Design 3
2.3 Operation mode 4
2.4 Measuring principle 4
2.5 Calculation of resulting web tension 4
3. Mounting 6
3.1 Accessory kits for mounting work 6
3.2 Transport screws 7
3.3 Load cell mounting 7
4. Installation 8
5. Maintenance 8
6. Spare parts and accessories 9
7. Technical Data 10
BEA--200989-EN-03
Load cell PD 21, PD 22, PD 23, PD 25
1. Safety
1.1 Key to symbols operations to be performed
additional important information and hints
text sections particularly worthy of note to ensure the safe
operation of load cell PD 2.
1.2 Description Please keep the above in a safe place and make accessible to
personnel at all times.
The description is part of the package supplied and should be read
carefully prior to assembly, operation and maintenance.
All jobs listed in this description should be performed by qualified or
suitably instructed personnel only.
1.3 Safety hints Never insert your hand or tools in moving rollers.
2. Function
2.1 Intended usage Load cell PD 2. may only be used to measure web tension.
Load cell PD 2. measures the tension exercised by the web on the
measuring roller. The web should run round the measuring roller at
between 60° and 180°. The load cells at both sides of the measuring
roller are connected to an electronic amplifier which evaluates the
signals.
Amplifier
B page 2
Load cell PD 21, PD 22, PD 23, PD 25
2.2 Design Load cell PD 2. consists of an outer and inner ring and two flanges.
The centring rings on both flanges enable the load cells to be mount-
Outer ring Measuring roller ed exactly.
The measuring roller ball bearing fits into the inner ring. The inner
ring is also the measuring element, a bi-directional flexing yoke on
which strain gauges, in the form of a full electrical bridge are
mounted.
With exception of PD 25 fixed mechanical stops protect the load cells
from overloading up to ten times the nominal measuring range.
Inner ring
Flange Flange
B page 3
Load cell PD 21, PD 22, PD 23, PD 25
2.3 Operation mode A stabilized DC voltage from the electronic amplifier feeds the fully
balanced strain gauge bridge. The web tension generates a resultant
“web tension” in the measuring direction. This resultant web tension
causes an imbalance in the strain gauge bridge and alters its output
voltage. This output voltage is a signal which reacts in relation to the
web tension.
2.4 Measuring principle The measuring principle is based on the determining of the radially
aligned bearing forces of a measuring roller around which a web is
wound.
Load cell PD 2. measures all tension factors in the measuring direc-
tion. The measuring direction always corresponds to the direction of
the plug. Tension factors at right angles to the measuring direction
are not registered, although they do stress the load cell. Should the
load cell mounting position no longer be on the horizontal plane, the
dead weight of the measuring roller must be taken into consideration.
Effective measuring direction Load cell mounting position without web tension
Effective
measuring
direction measuring γ
direction
Web tension F
FG
2.5 Calculation of resulting Proceed as indicated in the following diagram when calculating
web tension the resulting web tension.
Determine the web wrapping angle around the roller. A wrapping
angle of 90° should always be aimed at.
Now specify the measuring direction and calculate the resulting
web tension (see examples, page 5).
B page 4
Load cell PD 21, PD 22, PD 23, PD 25
Calculating the resulting web tension Calculating the resulting web tension
when the measuring direction when the measuring direction is on the vertical plane
is on the horizontal plane
measuring
F direction
α FR
F measuring
β α
direction
F2 F1 FR
F F F F
β
FG
F1
F2
F F F F
F1
F F F2
α β
FR FG
measuring
direction
B page 5
Load cell PD 21, PD 22, PD 23, PD 25
Accessory kits
PD 15 PD 22 PD 23
1 2 3 4 5 6 1
1 self-aligning ball bearing x x x x x x x
1 locking ring / shaft x x x x x
2 locking rings / boring x x x x x x x
1 distance sleeve x x x
2 distance sleeves x
1 set collar x x
2 set collars x
1 rotary locking ring x x
Accessory kits for load cell PD 21/25 for rollers with inner bearings:
Accessory kits for load cell PD 21/25 for rollers with outer bearings:
Movable bearing side Fixed bearing side
B page 6
Load cell PD 21, PD 22, PD 23, PD 25
Accessory kits for load cell PD 22 for rollers with outer bearings:
Accessory kits for load cell PD 23 for rollers with outer bearings:
Movable bearing side Fixed bearing side
Locking ring for *The accessory kits for movable bearing sides contain lock-
boring to DIN 471
ing rings for the boring and shaft. The locking rings for the
Locking ring for boring must not mounted on the movable bearing side. It
shaft to DIN 472 must be possible to move the outer ring of the self-aligning
ball bearing on the movable bearing side.
3.2 Transport screws The load cell is secured by two long transport screws whenever it is
transported. These two screws secure the measuring ring on the load
cell interior and thus protect it against knocks during transportation.
The transport protection screws must be replaced by the
shorter cover screws prior to commissioning otherwise web
tension monitoring will not be possible. Please ensure that
the cover screws are tightened securely.
As an additional precaution we have listed the dimensions of the
transport screws (PD 21, 22, 25 = DIN 84, PD 23 = DIN 912) and the
Transport screws cover screws in the table below:
on load cell PD 2.
Load cell PD 2.12, 2.15, 2.17 PD 2.20. 2.25 PD 2.30, 2.35 PD 2.40, 2.45, 2.50 PD 2.55, 2.60, 2.65
3.3 Load cell mounting Please ensure that no mechanical distortions arise between
the load cells and measuring roller. Mechanical distortions in-
fluence the operation of the load cells and, in extreme cases,
may cause damage!
During the installation bear in mind the measuring direction
of the load cells. Refer to the projects planning documents or
to the computation as described in chapter 2.5.
B page 7
Load cell PD 21, PD 22, PD 23, PD 25
4. Installation When running electric cables make sure that their insulation
is not damaged and the cables correctly secured and protect-
ed. Protect signal and run apart from power lines.
In case it becomes necessary for space reasons to turn the right
angle plug of the connecting cable by 90° or 180° before inserting
it into the socket, the plug insert of the right angle plug may be
turned carefully. Make sure that the insulation is not damaged.
Under no circumstances should the socket on the load cell
be turned.
5. Maintenance Protect the load cells from coarse dirt and moisture.
The self-aligning ball bearings of the load cells do not need any lu-
brication, they are greased for life. E+L uses grease Optimol, type
Longtime.
Make sure that the shorter cover screws are used instead of the long
transport screws so that no dirt may penetrate the load cell.
In case of malfunction, the load cell must be returned to the fac-
tory for replacement. No parts can be replaced on-site.
B page 8
Load cell PD 21, PD 22, PD 23, PD 25
Ø Journal diameter 12 mm 15 mm 17 mm 20 mm 25 mm 30 mm 35 mm 40 mm 45 mm 50 mm
Accessory kit 1 067059 067060 067061 067062 067063 067064 067065 067066 067067 067068
Accessory kit 2 067070 067071 067072 067073 067074 067075 067076 067077 067078 067079
Accessory kit 3 067081 067082 067083 067084 067085 067086 067087 067088 067089 067090
Accessory kit 4 067092 067093 067094 067095 067096 067097 067098 067099 067100 067101
Ø Journal
12 mm 15 mm 17 mm 20 mm 25 mm 30 mm 35 mm 40 mm 45 mm 50 mm 55 mm 60 mm 65 mm
diameter
Accessory kit 5 064368 064369 064370 064371 064372 064373 064374 064375 064376 064377 064378 064379 064380
Accessory kit 6 064340 064341 064342 064343 064344 064345 064346 064347 064348 064349 064350 064351 064352
6.5 Connection cable A range of cables in different types and sizes is available to connect
the load cell to the amplifier. The cables are screened and have a
right angle plug.
The following part numbers refer to the connection of one load
cell to the amplifier.
Load cell PD 23 includes an integrated 5 m cable.
IP 65 for ex-i protection type 062767 062768 062769 062770 062771 062772 062773 062088
PD 25
IP 50 208534 211310 211309 211308 - - - -
B page 9