E1 1 GENERAL NOTES

SI T E
1. ALL ELECTRICAL WORKS HEREIN SHALL CONFORM WITH THE LATEST EDITION OF THE
PHILIPPINE ELECTRICAL CODE (P.E.C.) WITH THE REQUIREMENTS OF THE UTILITY
COMPANIES CONCERNED AND WITH THE LOCAL GOVERNING GOVERNMENT AGENCY.

2. SERVICE TO THE BUILDING SHALL BW SINGLE PHASE, THREE-WIRES, 220 VOLTS, 60 HERTZ.

3. WIRING METHOD SHALL BA AS FOLLOWS:
A. INTERMEDIATE METALLIC CONDUIT (MC)- USED IN EXPOSED AND WET LOCATION OR
IN HOLLOW PORTIONS OF CEILING OR WALLS.
B. POLYVINYL CHLORIDE (PVC)- USED WHEN EMBEDDED IN CONCRETE SLAB OR
MASONRY ONLY, PROVIDE ADDITIONAL WIRE SOLELY FOR GROUNDING,BONDING FOR
GROUNDING, BONDING FOR ELECTRICAL CONTINUITY, USED FOR AUXILIARY
BRANCH CIRCUITS ONLY.

4. WHEN NOT INDICATED IN THE DRAWING SIZE OF RACEWAY SHALL BE 15mmØ WIRES SHALL BE
3.5mm² WITH INSULATION, ALL WIRE SHALL RATED 600 VOLTS.

5. ADEQUATE AND EFFECTIVE GROUNDING OF EQUIPMENT SHALL BE PROVIDED.

6. WIRE DEVICES SHALL BE AS FOLLOWS:


A. WALL SHICHES- 15 AMPS, FLUSH WALL MOUNTED
B. DUPLEX RECEPTACLE- 15 AMPS, 250 VOLTS, FLUSH WALL MOUNTED.

7. ALL OUTLET BOXES SHALL BE PRESSED GALVANIZED STEEL "DEEP TYPE" GUAGE #16 AND WITH
FACTORY KNOCKOUTS. 3 VICINITY MAP
8. ALL POWER AND AUXILLIARY LAYOUT ON AREAS WITH DROP CEILING SHALL NOT BE EMBEDDED E1 N T S

4 S E R V I C E E NT R A N C E
ON CONCRETE SLAB. CONDUIT LAYOUT SHALL RUN INSIDE CEILING OF THE NEXT FLOOR
SLAB TO BE MORE FEASIBLE IN THE RELOCATION OF OUTLETS.

9. MOUNTING HEIGHT SCHEDULE SHALL BE AS FOLLOWS:


E1 SCALE NTS

A. CONVENIENCE, TELEPHONE, INTERCOM, MATV OUTLETS- 0 .30m. ABOVE.


B. PANELBOARDS, TTC- 1.70m. aAT CENTER FROM FINISHED FLOOR LINE.
C. WALL SWICHES- 1.37m. AT CENTER FROM FLOOR FINISHED
D. AIR CONDITIONING UNITS- VERIFY WITH THE ARCHITECT. B B
10. PANELBOARD SHALL BE "QUICK BREAK" DEAD FRONT EQUIPPED WITH THE MAGNETIC TRIP
INDICATING MOLDED CASE CIRCUIT BREAKERS.
A B C D E F A B C D E F
2.55 13.87
11. ALL ELECTRICAL WORKS HEREIN SHALL BE UNDER THE IMMEDIATE SUPERVISION OF THE DULY 13.87
REGISTERED ELECTRICAL ENGINEER. 2.92
2.84 2.86 2.69 0.28 2.84 2.86 2.69 0.28
0.58 1.34 1.21 0.41 2.00 0.43 1.48 1.45 1.42 1.44 2.34 0.58 0.41 2.00 0.43 0.96 1.97 2.33 2.47 0.39

0.40 0.94 1.21 0.64 1.60 0.61 0.87 0.60 1.02 0.60 1.04 2.49 0.48 1.60 0.470.64 1.60 0.610.360.60 0.98 0.98 0.73 1.60 0.52 1.60

E1 2 LEGEND 4

0.70

0.70
4 4

0.86
b a
SYMBOL DESCRIPTION a a a b b a

1.44
c c

1.70
c c c

0.84
d

2 c c

2.85

2.85
9

2.85

2.55

2.85
c c c
SERVICE ENTRANCE b b

1.41
b b

1.00
b b a a a a a a a

1.15
M a,b
K I L O W A T T H O U R M E T ER
3
a,b

3
a,b

0.55
a,b,c

0.49 1.01
1.50 c c

1.50
CIRCUIT HOMERUN
c 3 5

1.60
a a
8.70

3.00

c c

8.70

3.00

2.70

3.00
d b b

10.57
A

10.57
CIRCUIT WIRING PASS ING THRU FLOORS AN D
A
1.35
1.50

1.50
WALLS c b b b b

0.85
a,b a,b

a SWITCH LINE 2 1 d
2 a,b d a,b
a a b
b b
1.50

1.44
b
6
1.35

1.35
7

2.00
b b a a
2.85

PANEL BOARD

2.85

2.55
d
0.500.500.50

c c

1.41
1.35

c b a a c

1.50
d b
CIRCUIT BREAKER

0.85
SINGLE POLE SWITCH 1 1 d,e,f

1.17
S1

1.17
1.00
e e e f f
UP
S2 TWO GANG SWITCH
S E C O N D F L O O R L I N E

LIGHTING OUTLET
1.56 0.30 2.57 0.30 2.64 0.30 2.55 0.30 2.54 0.30
WALL LAMP
0.90 1.60 0.630.41 2.00 0.83 2.00 1.01 2.00 3.33
1.94 0.96 0.30 2.57 0.30 2.64 0.30 2.55 0.30 2.54 0.30
3.05 2.92 2.94 2.80 2.99
PINLIGH T
0.90 0.55 1.68 2.79 0.81 1.35 0.94 2.71 2.98
14.70
3.05 2.92 2.94 2.80 2.99
COVE LIGHT 14.70

CONVENIENCE OU TLET

REF
REF. OUTLET

RANGE
RANGE OUTLET 5 GROUND FLOOR LIGHTING LAYOUT 6 SECOND FLOOR LIGHTING LAYOUT
E1 SCALE 1:100M E1 SCALE 1:100M
WEATHERPROOF OUTLET
WP

ACU OUTLET

DESIGNED BY: SEAL

PROFESSIONAL ELECTRICAL ENGINEER


I CERTIFY THAT THIS DRAWING WAS PREPARED BY
TWO STOREY COMMERCIAL BUILDING Mr. Jose E. Artiaga III
Mrs. Anna Liza A. Artiaga
AS SHOWN
E-1
ME OR UNDER MY DIRECT SUPERVISION.
JJ.AA

10 12

You might also like