You are on page 1of 2

Volvo Guided Diagnostics

Date: Information Type:


10/4/2019 Diagnostics Fault Codes 187: Vehicle Control Unit 1419: Pump 1 Discharge Pressure
Profile:
EC210C L Volvo

MID187 PPID1419 / SE9121


Showing Selected Profile

Valid for serial numbers


Model Production site Serial number start Serial number stop
EC210C L Volvo

SAE code
MID/Control Unit MID187 Vehicle Control Unit
PID/PPID/SID/PSID PPID1419 Pump 1 Discharge Pressure
Machine display message
Text presentation SE9121

Reference

Fault mode diagnosis

Fault mode Detection conditions:The vehicle control unit (V-ECU) registers: that the voltage is above
FMI 3 4.8 V (VB33) when the hydraulic oil temperature is higher than 50 °C (122°F).
Symptom: Possible causes:

¡ Yellow central warning ¡ Feed cable short-circuited to higher


¡ Alarm sounds 4 times voltage
¡ "Check" screen ¡ Signal line short-circuited to 5 V or
¡ Too slow machine speed higher voltage
¡ Open circuit on ground line
¡ Ground line short-circuited to 5 V
or higher voltage
¡ Defective sensor

Action SE9121, description and measuring

Fault mode Detection conditions:The vehicle control unit (V-ECU) registers: that the voltage is below
FMI 4 0.21 V (VB33)
Symptom: Possible causes:

¡ Yellow central warning ¡ Sensor not connected (open circuit)


¡ Alarm sounds 4 times ¡ Feed cable short-circuited to frame
¡ "Check" screen ground
¡ Too slow machine speed ¡ Signal line short-circuited to frame
ground
¡ Open circuit on feed cable
¡ Open circuit on signal line
¡ Defective sensor

Action SE9121, description and measuring