Professional Documents
Culture Documents
Orbit 60 Data Sheet
Orbit 60 Data Sheet
Datasheet
Bently Nevada Machinery Condition Monitoring 137M5182 Rev. K
Overview
The Orbit 60 Series Protection and Condition Monitoring System provides a single platform for the
continuous online monitoring of both critical and plant-wide applications. The Orbit 60 Series system
is deployable in any combination of rackmounted and distributed hardware, with Bridge modules
creating a seamless connection between chassis to make a single system.
The table below gives a general overview of the components that make the Orbit 60 platform.
Table 1: Component Modules
Input User Guide Dynamic Negative Dynamic Input (PAV, PAS*, PAA, PAD*, KPH)
Modules (137M0804) 4-channel (provides power for negatively powered transducers)
Positive Dynamic Input (PVT*)
(provides power for positively powered transducers)
Linear Variable Differential Transformer (AC LVDT*)
2/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
3/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
Chassis Types
Mounting Options
l Panel Mount – Mounts to rectangular cutouts in panels and secures to the panel using clamps
supplied with the chassis in 3U Mini*, 3U 19" standard, and 6U 19" standard* configurations. The
6U 19" will fit in the space of a 3500 rack.*
l Rackmount – Mounts the 3U or 6U chassis on 19-inch EIA rails. Two 3U units or a single 6U* form
factor have been designed to fit within the space of a single 19” rackmount 3500 unit, as a
retrofit.
l Bulkhead - Typically mounts into a protective enclosure fastened to a sub panel in 3U Mini*, 3U
19" standard, and 6U 19" standard* configurations. NEMA 4 and 4X weatherproof housings are
available when required for environmental protection or when purge air is used.
* Features not available in first release.
4/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
Statuses
The Standard Front Panel Module shows the status of the power supplies and the
presence and operation of the SIM Module.
Key Switch
This front panel can send run or program requests via the key switch.
When the key is in the RUN position, the ring lights green and the
protection system is engaged, but when the key is in the PRG, or
program mode, the ring lights amber and system configuration
changes can be made through Ethernet connection to the SIM.
Reset
Ethernet
An RJ45 jack provides Ethernet connection to the SIM for external display or
configuration tasks from the public side of the system.
* Not available in first release.
5/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
Each Orbit 60 system requires a single System Interface Module (SIM) The SIM
provides the user access to manage protection configuration, local display,
system-level diagnostics, system LEDs, system contacts, and the system
protection fault relay. The SIM occupies one slot and must be adjacent to the
Power Input Module (PIM) in the chassis.
The SIM is the access point for configuring and maintaining the system. The
module communicates to the Orbit Studio configuration software and transmits
the configuration to other modules in the system. The SIM provides a physical
access security feature through a key-lock switch on the public side and a
contact on the utility side of the SIM. Either of these controls can be used to secure
the system configuration, preventing unauthorized changes.
The SIM has 3 independently configurable ethernet ports, each port can be used
for system configuration, system time synchronization, temporary
troubleshooting, or an external display.
• Ethernet - Two RJ-45 ethernet ports supporting Modbus and EGD* protocols
* Features not available in first release.
6/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
7/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
supplies. The Instrument Common(IS) and Protective Earth connections for the
system are made at the utility side of the PIM. External redundant power supplies are
recommended for the system.
Remove and insert a single Power Input Module without disrupting system operation, as
long as another PIM remains installed and connected to its input power source.
For detailed information on requied Power Supply see associated datasheet
(142M8947).
8/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
Connectors
The Dynamic Input module uses an ix Industrial connection to provide access to four buffered
transducer output (BTO) connectors for each of the dynamic channels, with short circuit protection.
The ix Industrial connection is available on the public and utility side of the module.
9/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
10/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
11/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
12/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
Relay Modules
Program Relay modules to actuate based on alarm conditions
defined in other modules. Use standard logic elements(True
AND, Normal AND, OR and NOT) to combine various alarms and
statuses(alarm statuses, OK statuses and other statuses
(Bypass, Protection State, Inhibit, Attention, Protection Fault, etc.)
into relay activation conditions. Use Orbit Studio to program the
voting logic.
Relays can operate as a system or group protection fault relay,
if programmed to do so, especially when the protection fault
relay on the SIM does not provide adequate granularity of
system health - typically for multiple machines in one system.
Pairs of relays within the module function as a single Double-
Pole, Double-Throw relay when appropriately configured. All
relay types are available for SIL system implementation.
13/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
Proximitor Displacement X X X X X X
(3-wire)
Accelerometer Acceleration1 X X X X X
(3-wire)
Seismoprobe Velocity1, 2 X
(2-wire)
DC LVDT Position X
AC LVDT Position X
TC - Type Temperature X X
J, K, E, T
14/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
Static Input
Dynamic Input Module Type
Module Type
(4 channels)
Measurement (6 channels)
Sensor Type Supported
Type
AC
PAV PAS PAA PAD PVT KPH RTD ITC PVD
LVDT
15/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
External Display
The external display utilizes an industrial computer connected to the SIM via Ethernet. The computer
and display placement varies based on application needs. The 10.4", 15", and 21.5" VGA touchscreen
displays provide excellent viewing quality for industrial applications. The 10.4" display is suitable for
use in hazardous area locations across the world. The 15" display is certified for hazardous areas for
North America only. The 21.5" display is intended for non-hazardous (safe) area applications only.
l System-event list
l Alarm-event list
l All module and channel data
l Alarm and OK status
l Nine custom display options
16/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
To configure the Orbit 60 system, refer to the Orbit Studio online help or Orbit Studio Configuration
Software User Guide (137M0696).
17/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
System 1 Integration
Offering plant-wide condition monitoring insights to reduce risk, increase productivity, and minimize
unplanned downtime, System 1 streamlines decision-making processes by bringing machine data
into a single platform, providing clarity and context to your operations and enterprise. Harnessing the
power of Bently Nevada’s decades of machinery research and advanced diagnostics expertise, this
powerful tool is a key component of successful digital transformation in any industrial facility. By
combining its Connectivity, Analytics, and Visualization capabilities, System 1 is the premier Edge
historian and condition monitoring platform among industrial operators.
Take full advantage of System 1 Condition Monitoring Software in conjunction with Orbit 60 Series for
complete monitoring and advanced diagnostics for all machine types, including roller-element
bearings. Use the Orbit 60 Series Condition Monitoring Module (CMM) for a read-only access point to
provide a cyber-secure approach for obtaining data through the business network or other systems.
When used in conjunction with the Comm Gateway module (CGW), you can relay high speed
process data to System 1 along with system measured data.
Bently Nevada has a rich heritage in helping customers solve industrial maintenance challenges that
is over 60 years strong. Through user research in 25 countries with more than 500 end users, we have
studied our customers’ team dynamics, site processes, and technology suites to determine how
System 1 can best support plant-wide machinery management. The resulting platform is the most
comprehensive and user-intuitive condition monitoring solution ever developed.
18/31
ORBIT 60 SERIES System Overview
Datasheet 137M5182 Rev. K
System Environmental
Specifications Operating
Temperature -30° C to +65° C
Orbit 60 System (-22° F to 149° F)
Range
3U 19" Full-Load Chassis (indoor use
only)
Power Consumption
Storage -40°C to +85°C
Temperature (-40° F to 185° F)
Typical 120 watts
Range
Maximum 180 watts
Relative 0% to 95% rH non-
“The Orbit 60 Series system was Humidity condensing operating and
qualified with the power supplies storage
listed in accessory section of this Vibration 5 g @ 57-500 Hz. IEC 60068-
datasheet. Use of a reduced 2-6
wattage power supply may result in
changed behavior under fault Shock 10 g, 11 ms IEC 60068-2-27
conditions.”
Altitude < 2000 m (6,562 ft)
System Interface Module (SIM) l Configure user, roles and rights account
management.
System Contacts l Uses physical Run/Program control
l Aligned to the IEC 62443 standard. 1 Performed by either closing the contact on the
l Encrypted communications using latest module or pressing the button on the front
TLS standards. panel.
l PKI implemented signed firmware
2 Performed by either closing the contact on
images to facilitate secure boot and the module or setting the key on the front to the
trusted firmware updates. RUN setting on the front panel.
l Device identity management uses
certificates for trusted connections.
Cable Length 100 meters (328 feet) max Dimensions 15.25 x 9.8 x 1.93 in
387.4 x 248.9 x 49 mm
Condition Monitoring Module Environmental Limits - Indoor Use Only
Condition Monitoring Module (CMM) IP Rating Designed for IP54 ingress
protection against dust and
Data Communications
water spray to the front only.
2 ethernet Independent Ethernet ports Operating 0 to 60°C (32 to 140°F)
ports - utility 1000/100/10 Base-T Auto- Temperature
or rear side negotiation
Standards and Certifications
Connector RJ-45
Refer to External Display Datasheet
Cable Length 100 meters (328 feet) max (154M8401)
10.4" Hazardous Area Display 15" Hazardous Location Display
10.4” Hazardous Area Display 15” Hazardous Location Display
Part Number 120M8155-01 Part Number 102M8950
Warranty 1 Year Warranty 1 Year
Features Features
Video VGA Video VGA
Interface Interface
Touch Screen Resistive Touch Screen Touch Screen 5-Wire Resistive Touch
Type Type Screen
Cable Serial Touch Screen Serial
Interface Interface
Control Front panel button Control Front panel button
Settings Settings
Mounting Panel Mount, 19” EIA Rack Mounting Panel Mount and 19” EIA Rack
Styles Mount, and Independent Styles Mount
Mount
Power
Warranty 1 Year
Display CPU Module
Features CPU Module
Number of 8
Discrete Input
Relay Outputs
Discrete Input Dry Contact,
Environmental Epoxy Sealed
Internally Wetted
Wetted Contact, Operation Each relay is configurable
0 to 10 Vdc for Normally De-Energized
or Normally Energized
Contact Rating for Standard Systems
Characteristics
Number of 8
Relay Outputs
Maritime*
Compliance and Certifications ABS Rules for Condition of Classification,
Part 1
FCC
l Steel Vessels Rules
This device complies with part 15 of the l Offshore Units and Structures
FCC Rules. Operation is subject to the
following two conditions: Functional Safety*
l This device may not cause harmful
interference. SIL 2
l This device must accept any * Approvals pending
interference received, including
interference that may cause
undesired operation.
Hazardous Area Approvals
EMC
For the detailed listing of country and
European Community Directive:
product specific approvals, refer to
EMC Directive 2014/30/EU the Approvals Quick Reference Guide
(108M1756) available from
Standards: Bently.com.
EN 61000-6-2; Immunity for
Industrial Environments
CSA/NRTL/C
EN 61000-6-4; Emissions for
Industrial Environments Class I, Zone 2: AEx/Ex ec nC IIC T4 Gc;
Class I, Zone 2: AEx/Ex nA nC IIC T4 Gc;
Electrical Safety Class I, Division 2, Groups A, B, C, D T4;
European Community Directive: Class I, Division 2, Groups A, B, C, D T4
(N.I.);
LV Directive 2014/35/EU
T4 @ Ta= -30˚C to +65˚C (-22˚F to +149˚F)
Standards:
ATEX/IECEx
EN 61010-1;
EN 61010-2-201;
II 3 G
Ex ec nC IIC T4 Gc
RoHS Ex nA nC IIC T4 Gc
European Community Directive: T4 @ Ta= -30˚C to +65˚C (-22˚F to +149˚F)
RoHS Directive 2011/65/EU
Cyber Security
Designed to meet IEC 62443
Communications
Input Modules
Chassis: 3U Rack
Input: (PAV) Prox/Accel/Velom Module
60R/CHA01 with options for:
• Country-specific codes 60R/INP01 with options for:
• SIL level • Country-specific codes
Chassis: 3U Panel • SIL level
Input: (PAA) Prox/Accel/Aero Module
60R/CHA02 with options for:
• Country-specific codes 60R/INP02 with options for:
• SIL level • Country-specific codes
Chassis: 3U Bulkhead • SIL level
Input: (KPH) Keyphasor Module
60R/CHA03 with options for:
• Country-specific codes 60R/INP06 with options for:
• SIL level • Country-specific codes
• SIL level
System Modules
Input: RTD / TC Module
System Interface Module
60R/INP07 with options for:
60R/SIM01 with options for: • Country-specific codes
• Country-specific codes • SIL level
• SIL level Input: (PVD) Isolated PV / DI Module
Protection Processing Module
60R/INP09 with options for:
60R/PPM01 with options for: • Country-specific codes
• Country-specific codes • SIL level
• SIL level
Power Input Modules
Glossary of Terms
Accel Acceleration PVD Isolated Process Variable, Discrete
Aero Aeroderivative Input
API American Petroleum Institute PVT Positive Voltage Transducer
BRG Bridge REB Roller Element Bearing
BTO Buffered Transducer Output REC Recorder Outputs
CGW Communication Gateway Module RMC Remote Monitoring Center
CMM Condition Monitoring Module RST Reset
COM Common RTD Resistance Temperature Detector
DCS Distributed Control Systems SAI System Alarm Inhibit
EGD Ethernet Global Data protocol SHLD Shield
ESD Emergency Shutdown Device SIL Safety Integrity Level
EIA Energy Information Administration SIM System Interface Module
EMR electromechanical Relay SSR Solid State Relay
HAZLOC Hazardous Location SW Software
HTVAS High Temperature Velocity/Accel TC Thermocouple
Sensor TLS Transport Layer Security
I/O Input/Output RTD/TC Resistance Temp Detector /
IEPE Integrated Electronics Piezo-Electric Thermocouple
ITC Isolated Thermocouple TCP/IP Transmission Control Protocol
KPH High Speed Keyphasor Internet Protocol
TM Trip Multiply
LVDT Linear Variable Differential
Transformer OEM Orginal Equipment Manufacturer
NC Normally Closed Velom Velomitor
NEMA National Electrical Manufacturers
Association
NO Normally Opened
NTP Network Time Protocol
OEM Orginal Equipment Manufacturer
PAA Prox, Accel, Aero
PAD Prox, Accel, DC LVDT
PAS Prox, Accel, Seismic
PAV Prox, Accel, Velom
PIM Power Input Module
PLC Programmable Logic Controller
PPM Protection Processing Module
Prox Proximitor
Bently Nevada, Orbit Logo, Keyphasor, Velomitor, Proximitor, and System 1 are registered trademarks of Bently
Nevada, a Baker Hughes Business, in the United States and other countries. The Baker Hughes logo is a trademark of
Baker Hughes Company. All other product and company names are trademarks of their respective holders. Use of
the trademarks does not imply any affiliation with or endorsement by the respective holders.
Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does not
make any representation as to the accuracy or completeness of the information and makes no warranties of any
kind, specific, implied or oral, to the fullest extent permissible by law, including those of merchantability and fitness
for a particular purpose or use. Baker Hughes hereby disclaims any and all liability for any direct, indirect,
consequential or special damages, claims for lost profits, or third party claims arising from the use of the
information, whether a claim is asserted in contract, tort, or otherwise. Baker Hughes reserves the right to make
changes in specifications and features shown herein, or discontinue the product described at any time without
notice or obligation. Contact your Baker Hughes representative for the most current information.
The information contained in this document is the property of Baker Hughes and its affiliates; and is subject to
change without prior notice. It is being supplied as a service to our customers and may not be altered or its content
repackaged without the express written consent of Baker Hughes. This product or associated products may be
covered by one or more patents. See Bently.com/legal.
31/31