You are on page 1of 16

ESP8266 Datasheet

Espressif Systems

Categories Items Values

Certificates FCC/CE/TELEC/SRRC

WiFi Protocles 802.11 b/g/n

Frequency Range 2.4G-2.5G (2400M-2483.5M)

802.11 b: +20 dBm

Tx Power 802.11 g: +17 dBm


WiFi Paramters 802.11 n: +14 dBm

802.11 b: -91 dbm (11 Mbps)

Rx Sensitivity 802.11 g: -75 dbm (54 Mbps)

802.11 n: -72 dbm (MCS7)

PCB Trace, External, IPEX Connector,


Types of Antenna
Ceramic Chip

UART/SDIO/SPI/I2C/I2S/IR Remote Control


Peripheral Bus
GPIO/PWM

Operating Voltage 3.0~3.6V

Hardware Operating Current Average value: 80mA


Paramaters Operating Temperature Range -40°~125°

Ambient Temperature Range Normal temperature

Package Size 5x5mm

External Interface N/A

WiFi mode station/softAP/SoftAP+station

Security WPA/WPA2

Encryption WEP/TKIP/AES

Firmware Upgrade UART Download / OTA (via network)


Software
Parameters Supports Cloud Server Development / SDK
Ssoftware Development
for custom firmware development

Network Protocols IPv4, TCP/UDP/HTTP/FTP

Espressif Systems 8/31 June 1, 2015


ESP8266 Datasheet
Espressif Systems

AT Instruction Set, Cloud Server, Android/


User Configuration
iOS App

1.4. Ultra Low Power Technology


ESP8266EX has been designed for mobile, wearable electronics and Internet of Things applications
with the aim of achieving the lowest power consumption with a combination of several proprietary
techniques. The power saving architecture operates mainly in 3 modes: active mode, sleep mode
and deep sleep mode.
By using advance power management techniques and logic to power-down functions not required
and to control switching between sleep and active modes, ESP8266EX consumes about than 60uA in
deep sleep mode (with RTC clock still running) and less than 1.0mA (DTIM=3) or less than 0.5mA
(DTIM=10) to stay connected to the access point.
When in sleep mode, only the calibrated real-time clock and watchdog remains active. The real-time
clock can be programmed to wake up the ESP8266EX at any required interval.
The ESP8266EX can be programmed to wake up when a specified condition is detected. This
minimal wake-up time feature of the ESP8266EX can be utilized by mobile device SOCs, allowing
them to remain in the low-power standby mode until WiFi is needed.
In order to satisfy the power demand of mobile and wearable electronics, ESP8266EX can be
programmed to reduce the output power of the PA to fit various application profiles, by trading off
range for power consumption.

1.5. Major Applications


Major fields of ESP8266EX applications to Internet-of-Things include:
• Home Appliances
• Home Automation
• Smart Plug and lights
• Mesh Network
• Industrial Wireless Control
• Baby Monitors
• IP Cameras
• Sensor Networks
• Wearable Electronics

Espressif Systems 9/31 June 1, 2015


ESP8266 Datasheet
Espressif Systems

Note: GPIO2, GPIO0, MTDO can be configurable as 3-bit SDIO mode.

2.2. Electrical Characteristics


Table 3 ESP8266EX Electrical Characteristics

Parameters Conditions Min Typical Max Unit


Storage Temperature Range -40 Normal 125 ℃
IPC/JEDEC J-
Maximum Soldering Temperature 260 ℃
STD-020
Working Voltage Value 3.0 3.3 3.6 V
VIL/VIH -0.3/0.75VIO 0.25VIO/3.6
V
I/O VOL/VOH N/0.8VIO 0.1VIO/N

IMAX 12 mA
Electrostatic Discharge (HBM) TAMB=25℃ 2 KV
Electrostatic Discharge (CDM) TAMB=25℃ 0.5 KV

2.3. Power Consumption


The following current consumption is based on 3.3V supply, and 25°C ambient, using internal
regulators. Measurements are done at antenna port without SAW filter. All the transmitter’s
measurements are based on 90% duty cycle, continuous transmit mode.
Table 4 Description on Power Consumption

Parameters Min Typical Max Unit


Tx802.11b, CCK 11Mbps, P OUT=+17dBm 170 mA
Tx 802.11g, OFDM 54Mbps, P OUT =+15dBm 140 mA
Tx 802.11n, MCS7, P OUT =+13dBm 120 mA
Rx 802.11b, 1024 bytes packet length , -80dBm 50 mA
Rx 802.11g, 1024 bytes packet length, -70dBm 56 mA
Rx 802.11n, 1024 bytes packet length, -65dBm 56 mA
Modem-Sleep① 15 mA
Light-Sleep② 0.9 mA
Deep-Sleep③ 10 uA
Power Off 0.5 uA

Espressif Systems 13/31 June 1, 2015


DHT 11 Humidity & Temperature
Sensor

1. Introduction
This DFRobot DHT11 Temperature & Humidity Sensor features a temperature & humidity sensor
complex with a calibrated digital signal output. By using the exclusive digital-signal-acquisition
technique and temperature & humidity sensing technology, it ensures high reliability and
excellent long-term stability. This sensor includes a resistive-type humidity measurement
component and an NTC temperature measurement component, and connects to a high-
performance 8-bit microcontroller, offering excellent quality, fast response, anti-interference
ability and cost-effectiveness.

Page | 2
Each DHT11 element is strictly calibrated in the laboratory that is extremely accurate on
humidity calibration. The calibration coefficients are stored as programmes in the OTP memory,
which are used by the sensor’s internal signal detecting process. The single-wire serial interface
makes system integration quick and easy. Its small size, low power consumption and up-to-20
meter signal transmission making it the best choice for various applications, including those
most demanding ones. The component is 4-pin single row pin package. It is convenient to
connect and special packages can be provided according to users’ request.

2. Technical Specifications:

Overview:

Item Measurement Humidity Temperature Resolution Package


Range Accuracy Accuracy
DHT11 20-90%RH ±5%RH ±2℃ 1 4 Pin Single
0-50 ℃ Row

Page | 3
Detailed Specifications:

Parameters Conditions Minimum Typical Maximum


Humidity
Resolution 1%RH 1%RH 1%RH
8 Bit
Repeatability ±1%RH
Accuracy 25℃ ±4%RH
0-50℃ ±5%RH
Interchangeability Fully Interchangeable
Measurement 0℃ 30%RH 90%RH
Range 25℃ 20%RH 90%RH
50℃ 20%RH 80%RH
Response Time 1/e(63%)25℃, 6 S 10 S 15 S
(Seconds) 1m/s Air
Hysteresis ±1%RH
Long-Term Typical ±1%RH/year
Stability
Temperature
Resolution 1℃ 1℃ 1℃
8 Bit 8 Bit 8 Bit
Repeatability ±1℃
Accuracy ±1℃ ±2℃
Measurement 0℃ 50℃
Range
Response Time 1/e(63%) 6S 30 S
(Seconds)

Page | 4
EVALUATION KIT AVAILABLE

MAX30100 Pulse Oximeter and Heart-Rate Sensor IC


for Wearable Health

General Description Benefits and Features


The MAX30100 is an integrated pulse oximetry and heart- ●● Complete Pulse Oximeter and Heart-Rate Sensor
rate monitor sensor solution. It combines two LEDs, a Solution Simplifies Design
photodetector, optimized optics, and low-noise analog • Integrated LEDs, Photo Sensor, and
signal processing to detect pulse oximetry and heart-rate High-Performance Analog Front -End
signals. • Tiny 5.6mm x 2.8mm x 1.2mm 14-Pin Optically
The MAX30100 operates from 1.8V and 3.3V power sup- Enhanced System-in-Package
plies and can be powered down through software with ●● Ultra-Low-Power Operation Increases Battery Life for
negligible standby current, permitting the power supply to Wearable Devices
remain connected at all times. • Programmable Sample Rate and LED Current for
Power Savings
Applications • Ultra-Low Shutdown Current (0.7µA, typ)
●● Wearable Devices
●● Advanced Functionality Improves Measurement
●● Fitness Assistant Devices
Performance
●● Medical Monitoring Devices
• High SNR Provides Robust Motion Artifact Resil-
ience
• Integrated Ambient Light Cancellation
• High Sample Rate Capability
• Fast Data Output Capability

Ordering Information appears at end of data sheet.

System Block Diagram

COVER GLASS NO INK

10
ADC

CONTROL
SIGNAL
HbO2 PROCESSING

Hb

0.1
RED IR

19-7065; Rev 0; 9/14


MAX30100 Pulse Oximeter and Heart-Rate Sensor IC
for Wearable Health

Absolute Maximum Ratings


VDD to GND..........................................................-0.3V to +2.2V Continuous Power Dissipation (TA = +70°C)
GND to PGND.......................................................-0.3V to +0.3V OESIP (derate 5.8mW/°C above +70°C).....................464mW
x_DRV, x_LED+ to PGND.....................................-0.3V to +6.0V Operating Temperature Range............................ -40°C to +85°C
All Other Pins to GND...........................................-0.3V to +6.0V Soldering Temperature (reflow)........................................+260°C
Output Short-Circuit Current Duration........................Continuous Storage Temperature Range............................. -40°C to +105°C
Continuous Input Current into Any Terminal.....................±20mA

Package Thermal Characteristics (Note 1)


OESIP
Junction-to-Ambient Thermal Resistance (θJA).........150°C/W
Junction-to-Case Thermal Resistance (θJC)..............170°C/W
Note 1: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a four-layer
board. For detailed information on package thermal considerations, refer to www.maximintegrated.com/thermal-tutorial.

Electrical Characteristics
(VDD = 1.8V, VIR_LED+ = VR_LED+ = 3.3V, TA = +25°C, min/max are from TA = -40°C to +85°C, unless otherwise noted.) (Note 2)

PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS


POWER SUPPLY

Power-Supply Voltage VDD Guaranteed by RED and IR count tolerance 1.7 1.8 2.0 V

LED Supply Voltage


VLED+ Guaranteed by PSRR of LED Driver 3.1 3.3 5.0 V
(R_LED+ or IR_LED+ to PGND)
SpO2 and heart rate modes,
600 1200
PW = 200µs, 50sps
Supply Current IDD µA
Heart rate only mode,
600 1200
PW = 200µs, 50sps
Supply Current in Shutdown ISHDN TA = +25°C, MODE = 0x80 0.7 10 µA
SENSOR CHARACTERISTICS
ADC Resolution 14 bits
Propriety ATE setup
Red ADC Count
REDC RED_PA = 0x05, LED_PW = 0x00, 23,000 26,000 29,000 Counts
(Note 3)
SPO2_SR = 0x07, TA = +25°C
Propriety ATE setup
IR ADC Count
IRC IR_PA = 0x09, LED_PW = 0x00, 23,000 26,000 29,000 Counts
(Note 3)
SPO2_SR = 0x07, TA = +25°C
RED_PA = IR_PA = 0x00,
Dark Current Count DCC 0 3 Counts
LED_PW = 0x03, SPO2_SR = 0x01

Number of ADC counts with


RED LED 0
finger on sensor under direct
DC Ambient Light Rejection
ALR sunlight (100K lux) Counts
(Note 4)
LED_PW = 0x03,
IR LED 0
SPO2_SR = 0x01

www.maximintegrated.com Maxim Integrated │  2


MAX30100 Pulse Oximeter and Heart-Rate Sensor IC
for Wearable Health

Electrical Characteristics (continued)


(VDD = 1.8V, VIR_LED+ = VR_LED+ = 3.3V, TA = +25°C, min/max are from TA = -40°C to +85°C, unless otherwise noted.) (Note 2)

PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS


Propriety ATE setup
1.7V < VDD < 2.0V,
0.25 2 %
IR ADC Count—PSRR (VDD) PSRRVDD LED_PW = 0x03, SPO2_SR = 0x01,
IR_PA = 0x09, IR_PA = 0x05, TA = +25°C
Frequency = DC to 100kHz, 100mVP-P 10 LSB
Propriety ATE setup
3.1V < X_LED+ < 5V,
RED/IR ADC Count—PSRR 0.05 2 %
PSRRLED LED_PW = 0x03, SPO2_SR = 0x01,
(X_LED+) IR_PA = 0x09, IR_PA = 0x05, TA = +25°C
Frequency = DC to 100kHz, 100mVP-P 10 LSB
LED_PW = 0x00 200 µs
ADC Integration Time INT
LED_PW = 0x03 1600 µs
IR LED CHARACTERISTICS (Note 4)
LED Peak Wavelength λP ILED = 20mA, TA = +25°C 870 880 900 nm
Full Width at Half Max Δλ ILED = 20mA, TA = +25°C 30 nm
Forward Voltage VF ILED = 20mA, TA = +25°C 1.4 V
Radiant Power PO ILED = 20mA, TA = +25°C 6.5 mW
RED LED CHARACTERISTICS (Note 4)
LED Peak Wavelength λP ILED = 20mA, TA = +25°C 650 660 670 nm
Full Width at Half Max Δλ ILED = 20mA, TA = +25°C 20 nm
Forward Voltage VF ILED = 20mA, TA = +25°C 2.1 V
Radiant Power PO ILED = 20mA, TA = +25°C 9.8 mW
TEMPERATURE SENSOR
Temperature ADC Acquisition
TT TA = +25°C 29 ms
Time
Temperature Sensor Accuracy TA TA = +25°C ±1 °C
Temperature Sensor Minimum
TMIN -40 °C
Range
Temperature Sensor Maximum
TMAX 85 °C
Range

www.maximintegrated.com Maxim Integrated │  3


MAX30100 Pulse Oximeter and Heart-Rate Sensor IC
for Wearable Health

Electrical Characteristics (continued)


(VDD = 1.8V, VIR_LED+ = VR_LED+ = 3.3V, TA = +25°C, min/max are from TA = -40°C to +85°C, unless otherwise noted.) (Note 2)

PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS


DIGITAL CHARACTERISTICS (SDA, SDA, INT)
Output Low Voltage SDA, INT VOL ISINK = 6mA 0.4 V
I2C Input Voltage Low VIL_I2C SDA, SCL 0.4 V
I2C Input Voltage High VIH_I2C SDA, SCL 1.4 V
Input Hysteresis VHYS SDA, SCL 200 mV
Input Capacitance CIN SDA, SCL 10 pF
VIN = 0V, TA = +25°C
0.01 1 µA
(SDA, SCL, INT)
Input Leakage Current IIN
VIN = 5.5V, TA = +25°C
0.01 1 µA
(SDA, SCL, INT)
I2C TIMING CHARACTERISTICS (SDA, SDA, INT)
I2C Write Address AE Hex
I2C Read Address AF Hex
Serial Clock Frequency fSCL 0 400 kHz
Bus Free Time Between STOP
tBUF 1.3 µs
and START Conditions
Hold Time (Repeated) START
tHD,START 0.6 µs
Condition
SCL Pulse-Width Low tLOW 1.3 µs
SCL Pulse-Width High tHIGH 0.6 µs
Setup Time for a Repeated START
tSU,START 0.6 µs
Condition
Data Hold Time tHD,DAT 0 900 ns
Data Setup Time tSU,DAT 100 ns
Setup Time for STOP Condition tSU,STOP 0.6 µs
Pulse Width of Suppressed Spike tSP 0 50 ns
Bus Capacitance CB 400 pF
SDA and SCL Receiving Rise
tR 20 + 0.1CB 300 ns
Time
SDA and SCL Receiving Fall Time tRF 20 + 0.1CB 300 ns
SDA Transmitting Fall Time tTF 20 + 0.1CB 300 ns

Note 2: All devices are 100% production tested at TA = +25°C. Specifications over temperature limits are guaranteed by Maxim
Integrated’s bench or proprietary automated test equipment (ATE) characterization.
Note 3: Specifications are guaranteed by Maxim Integrated’s bench characterization and by 100% production test using proprietary
ATE setup and conditions.
Note 4: For design guidance only. Not production tested.

www.maximintegrated.com Maxim Integrated │  4


HANWEI ELETRONICS CO.,LTD MQ-2 http://www.hwsensor.com

TECHNICAL DATA MQ-2 GAS SENSOR


FEATURES
Wide detecting scope Fast response and High sensitivity
Stable and long life Simple drive circuit
APPLICATION
They are used in gas leakage detecting equipments in family and industry, are suitable for detecting
of LPG, i-butane, propane, methane ,alcohol, Hydrogen, smoke.
SPECIFICATIONS
A. Standard work condition
Symbol Parameter name Technical condition Remarks
Vc Circuit voltage 5V±0.1 AC OR DC
VH Heating voltage 5V±0.1 ACOR DC
www.DataSheet4U.com RL Load resistance can adjust
RH Heater resistance 33Ω±5% Room Tem
PH Heating consumption less than 800mw
B. Environment condition
Symbol Parameter name Technical condition Remarks
Tao Using Tem -20℃-50℃
Tas Storage Tem -20℃-70℃
RH Related humidity less than 95%Rh
O2 Oxygen concentration 21%(standard condition)Oxygen minimum value is
concentration can affect sensitivity over 2%
C. Sensitivity characteristic
Symbol Parameter name Technical parameter Remarks
Rs Sensing 3KΩ-30KΩ Detecting concentration
Resistance (1000ppm iso-butane ) scope:
200ppm-5000ppm
α Concentration LPG and propane
(3000/1000) Slope rate ≤0.6 300ppm-5000ppm
isobutane butane
Standard Temp: 20℃±2℃ Vc:5V±0.1 5000ppm-20000ppm
Detecting Humidity: 65%±5% Vh: 5V±0.1 methane
Condition 300ppm-5000ppm H2
Preheat time Over 24 hour 100ppm-2000ppm
Alcohol
D. Structure and configuration, basic measuring circuit

Parts Materials
1 Gas sensing SnO2
layer
2 Electrode Au
3 Electrode line Pt
4 Heater coil Ni-Cr alloy
5 Tubular ceramic Al2O3
6 Anti-explosion Stainless steel gauze
network (SUS316 100-mesh)
7 Clamp ring Copper plating Ni
8 Resin base Bakelite
9 Tube Pin Copper plating Ni
Fig.2
Fig. 1
Configuration A Configuration B

A向 A向
Structure and configuration of MQ-2 gas sensor is shown as Fig. 1 (Configuration A or B), sensor composed by
micro AL2O3 ceramic tube, Tin Dioxide (SnO2) sensitive layer, measuring electrode and heater are fixed into a

TEL: 86-371- 67169070 67169080 FAX: 86-371-67169090 E-mail: sales@hwsensor.com


HANWEI ELETRONICS CO.,LTD MQ-2 http://www.hwsensor.com
crust made by plastic and stainless steel net. The heater provides necessary work conditions for work of
sensitive components. The enveloped MQ-2 have 6 pin ,4 of them are used to fetch signals, and other 2 are used
for providing heating current.
Electric parameter measurement circuit is shown as Fig.2
E. Sensitivity characteristic curve

MQ-2
10 Fig.3 is shows the typical
sensitivity characteristics of
the MQ-2 for several gases.
in their: Temp: 20℃、
Humidity: 65%、
O2 concentration 21%
RL=5kΩ
www.DataSheet4U.com Ro: sensor resistance at 1000ppm of
H2 in the clean air.
Rs/Ro

Rs:sensor resistance at various


1 concentrations of gases.
H2
LPG
CH4
CO
alcohol
smoke
propane
air
ppm
0.1
100 1000 10000
Fig.2 sensitivity characteristics of the MQ-2

1.8
1.6
1.4
33%RH
Fig.4 is shows the typical dependence of
1.2 85%RH
the MQ-2 on temperature and humidity.
Rs/Ro

1 Ro: sensor resistance at 1000ppm of H2 in air


0.8 at 33%RH and 20 degree.
0.6 Rs: sensor resistance at 1000ppm of H2
0.4 Fig.4 at different temperatures and humidities.
0.2 degree
0
-20 -10 0 10 20 30 40 50 60

SENSITVITY ADJUSTMENT
Resistance value of MQ-2 is difference to various kinds and various concentration gases. So,When using
this components, sensitivity adjustment is very necessary. we recommend that you calibrate the detector for
1000ppm liquified petroleum gas<LPG>,or 1000ppm iso-butane<i-C4H10>concentration in air and use value of
Load resistance that( RL) about 20 KΩ(5KΩ to 47 KΩ).
When accurately measuring, the proper alarm point for the gas detector should be determined after
considering the temperature and humidity influence.

TEL: 86-371- 67169070 67169080 FAX: 86-371-67169090 E-mail: sales@hwsensor.com


HANWEI ELETRONICS CO.,LTD MQ-9 http://www.hwsensor.com

TECHNICAL DATA MQ-9 GAS SENSOR


FEATURES
* High sensitivity to carbon monoxide and CH4,LPG.
* Stable and long life
APPLICATION
They are used in gas detecting equipment for carbon monoxide and CH4,LPG in house
and industry or car.
SPECIFICATIONS
A. Standard work condition
Symbol Parameter name technical condition Remark
Vc circuit voltage 5V±0.1 AC or DC
VH (H) Heating voltage (high) 5V±0.1 AC or DC
VH (L) Heating voltage (low) 1.4V±0.1 AC or DC
RL Load resistance Can adjust
RH Heating resistance 33Ω±5% Room temperature
TH (H) Heating time (high) 60±1 seconds
TH (L) Heating time (low) 90±1 seconds
Ps Heating consumption Less than 340mw
b. Environment conditions

Symbol Parameters Technical conditions Remark


Tao Using temperature -20℃-50℃
Tas Storage temperature -20℃-50℃ Advice using scope
RH Relative humidity Less than 95%RH
O2 Oxygen concentration 21%(stand condition) Minimum value is over 2%
the oxygen concentration can
affect the sensitivity
characteristic
c. Sensitivity characteristic

symbol Parameters Technical parameters Remark


Rs Surface resistance In 100ppm
Of sensitive body 2-20k Carbon Monoxide
а(300/100ppm) Concentration slope rate Less than 0.5 Rs (300ppm)/Rs(100ppm)
Standard working Temperature -20℃±2℃ relative humidity 65%±5% RL:10KΩ±5%
condition Vc:5V±0.1V VH:5V±0.1V VH:1.4V±0.1V
Preheat time No less than 48 hours Detecting range:20ppm-2000ppm carbon monoxide
500ppm-10000ppm CH4
500ppm-10000ppm LPG

D. Structure and configuration, basic measuring circuit


Structure and configuration of MQ-9 gas sensor is shown as Fig. 1 (Configuration A or B),
sensor composed by micro AL2O3 ceramic tube, Tin Dioxide (SnO2) sensitive layer, measuring
electrode and heater are fixed into a crust made by plastic and stainless steel net. The heater
provides necessary work conditions for work of sensitive components. The enveloped MQ-9 have
HANWEI ELETRONICS CO.,LTD MQ-9 http://www.hwsensor.com

6 pin ,4 of them are used to fetch signals, and other 2 are used for providing heating current.

Parts Materials
1 Gas sensing SnO2
layer
2 Electrode Au
3 Electrode line Pt
4 Heater coil Ni-Cr alloy
5 Tubular ceramic Al2O3
6 Anti-explosion Stainless steel gauze
network (SUS316 100-mesh)
7 Clamp ring Copper plating Ni
8 Resin base Bakelite
9 Tube Pin Copper plating Ni

Fig.1

A向 A向

Standard circuit:
Heating voltage 5v (High) 60s
As shown in Fig 2, standard measuring circuit of
VRL MQ-9 sensitive components consists of 2 parts. one
VH

is heating circuit having time control function (the


high voltage and the low voltage work
RL circularly ). The second is the signal output circuit,
Vc it can accurately respond changes of surface
Fig.2
resistance of the sensor.
Heating voltage 1.4v (Low) 90s
Electric parameter measurement circuit is shown as Fig.2
Fig.3 is shows the typical
E. Sensitivity characteristic curve
sensitivity characteristics of
10
MQ-9 the MQ-9 for several gases.
in their: Temp: 20℃、
Humidity: 65%、
LPG
O2 concentration 21%
CO

CH4
RL=10kΩ
Air Ro: sensor resistance at 1000ppm
Rs/Ro

1 LPG in the clean air.


Rs: sensor resistance at various
concentrations of gases.

ppm
0 .1
100 100 0 10 000

Fig.3 sensitivity characteristics of the MQ-9


Handson Technology
Data Specs

RC522 RFID Development Kit


This RC522 RFID Development kit is based on NXP's a highly integrated reader/writer IC MFRC522 for
contactless communication at 13.56 MHz. The MFRC522 reader supports ISO/IEC 14443 A/MIFARE and
NTAG. The MFRC522’s internal transmitter is able to drive a reader/ writer antenna designed to
communicate with ISO/IEC 14443A cards and transponders without additional active circuitry. The receiver
module provides a robust and efficient implementation for demodulating and decoding signals from
ISO/IEC 14443A compatible cards and transponders.

SKU: MDU1040

Brief Data:

 Operating Voltage: 2.5V~3.3V.


 Operating/Standby current: 13~26mA/10~13mA.
 Operating Frequency: 13.56MHz.
 Supports ISO/IEC 14443A higher transfer speed communication up to 848 KBd.
 SPI bus speed up to 10Mbit/s.
 I2C-bus interface up to 400 kBd in Fast mode, up to 3400 kBd in High-speed mode.
 RS232 Serial UART up to 1228.8 kBd, with voltage levels dependant on pin voltage
supply.
 Compatible with MIFARE and ISO 14443A cards.
 Typical operating distance in Read/Write mode up to 50 mm depending on the antenna
size and tuning.

1 www.handsontec.com
Interface Pins Function:

Mechanical Dimension:

P.S: This module does not support RFID cards which operate at 125KHz frequency range. It supports
only the cards which operate at 13.56MHz frequency range.

2 www.handsontec.com

You might also like