ESP8266 Datasheet
Espressif Systems
ESP8266 Datasheet
Espressif Systems
IMAX 12 mA
Electrostatic Discharge (HBM) TAMB=25℃ 2 KV
Electrostatic Discharge (CDM) TAMB=25℃ 0.5 KV
1. Introduction
This DFRobot DHT11 Temperature & Humidity Sensor features a temperature & humidity sensor
complex with a calibrated digital signal output. By using the exclusive digital-signal-acquisition
technique and temperature & humidity sensing technology, it ensures high reliability and
excellent long-term stability. This sensor includes a resistive-type humidity measurement
component and an NTC temperature measurement component, and connects to a high-
performance 8-bit microcontroller, offering excellent quality, fast response, anti-interference
ability and cost-effectiveness.
Page | 2
Each DHT11 element is strictly calibrated in the laboratory that is extremely accurate on
humidity calibration. The calibration coefficients are stored as programmes in the OTP memory,
which are used by the sensor’s internal signal detecting process. The single-wire serial interface
makes system integration quick and easy. Its small size, low power consumption and up-to-20
meter signal transmission making it the best choice for various applications, including those
most demanding ones. The component is 4-pin single row pin package. It is convenient to
connect and special packages can be provided according to users’ request.
2. Technical Specifications:
Overview:
Page | 3
Detailed Specifications:
Page | 4
EVALUATION KIT AVAILABLE
10
ADC
CONTROL
SIGNAL
HbO2 PROCESSING
Hb
0.1
RED IR
Electrical Characteristics
(VDD = 1.8V, VIR_LED+ = VR_LED+ = 3.3V, TA = +25°C, min/max are from TA = -40°C to +85°C, unless otherwise noted.) (Note 2)
Power-Supply Voltage VDD Guaranteed by RED and IR count tolerance 1.7 1.8 2.0 V
Note 2: All devices are 100% production tested at TA = +25°C. Specifications over temperature limits are guaranteed by Maxim
Integrated’s bench or proprietary automated test equipment (ATE) characterization.
Note 3: Specifications are guaranteed by Maxim Integrated’s bench characterization and by 100% production test using proprietary
ATE setup and conditions.
Note 4: For design guidance only. Not production tested.
Parts Materials
1 Gas sensing SnO2
layer
2 Electrode Au
3 Electrode line Pt
4 Heater coil Ni-Cr alloy
5 Tubular ceramic Al2O3
6 Anti-explosion Stainless steel gauze
network (SUS316 100-mesh)
7 Clamp ring Copper plating Ni
8 Resin base Bakelite
9 Tube Pin Copper plating Ni
Fig.2
Fig. 1
Configuration A Configuration B
A向 A向
Structure and configuration of MQ-2 gas sensor is shown as Fig. 1 (Configuration A or B), sensor composed by
micro AL2O3 ceramic tube, Tin Dioxide (SnO2) sensitive layer, measuring electrode and heater are fixed into a
MQ-2
10 Fig.3 is shows the typical
sensitivity characteristics of
the MQ-2 for several gases.
in their: Temp: 20℃、
Humidity: 65%、
O2 concentration 21%
RL=5kΩ
www.DataSheet4U.com Ro: sensor resistance at 1000ppm of
H2 in the clean air.
Rs/Ro
1.8
1.6
1.4
33%RH
Fig.4 is shows the typical dependence of
1.2 85%RH
the MQ-2 on temperature and humidity.
Rs/Ro
SENSITVITY ADJUSTMENT
Resistance value of MQ-2 is difference to various kinds and various concentration gases. So,When using
this components, sensitivity adjustment is very necessary. we recommend that you calibrate the detector for
1000ppm liquified petroleum gas<LPG>,or 1000ppm iso-butane<i-C4H10>concentration in air and use value of
Load resistance that( RL) about 20 KΩ(5KΩ to 47 KΩ).
When accurately measuring, the proper alarm point for the gas detector should be determined after
considering the temperature and humidity influence.
6 pin ,4 of them are used to fetch signals, and other 2 are used for providing heating current.
Parts Materials
1 Gas sensing SnO2
layer
2 Electrode Au
3 Electrode line Pt
4 Heater coil Ni-Cr alloy
5 Tubular ceramic Al2O3
6 Anti-explosion Stainless steel gauze
network (SUS316 100-mesh)
7 Clamp ring Copper plating Ni
8 Resin base Bakelite
9 Tube Pin Copper plating Ni
Fig.1
A向 A向
Standard circuit:
Heating voltage 5v (High) 60s
As shown in Fig 2, standard measuring circuit of
VRL MQ-9 sensitive components consists of 2 parts. one
VH
CH4
RL=10kΩ
Air Ro: sensor resistance at 1000ppm
Rs/Ro
ppm
0 .1
100 100 0 10 000
SKU: MDU1040
Brief Data:
1 www.handsontec.com
Interface Pins Function:
Mechanical Dimension:
P.S: This module does not support RFID cards which operate at 125KHz frequency range. It supports