Professional Documents
Culture Documents
Cirugia Guiada Medidas
Cirugia Guiada Medidas
compatibility specifications
the BioHorizons table of contents
guided surgery kit color-coding reference 3-4
bone-level implants 3
The BioHorizons guided surgery kit offers the precision and
tissue-level implants 4
predictability of guided implant placement with a streamlined,
single kit design. All components are color-coded to avoid the guided surgery specifications 5-7
complexity seen with other systems while offering our customers
master cylinders 5
predictable implant placement for optimal esthetic outcomes.
surgical protocols 6
offset, drill length and stop position 7
pilot guide specifications 8-9
body body
diameter 3.0mm 3.4mm 3.8mm 4.6mm 5.8mm 3.8mm 4.6mm 5.8mm 4.2mm diameter 3.0mm 3.8mm 4.6mm 5.8mm
master
master
cylinder
cylinder
(for osteotomy only)
implant driver
implant driver (for placing implant
without the guide)
3.8/3.0 Tapered Plus Tapered Internal Tapered Plus 4.6/3.5 Tapered Tapered Internal Implant Driver
Implant Driver Implant Driver Implant Driver Plus Implant Driver
The table below illustrates the guided surgery protocols for the Tapered family of implants. The implant length (L), requested in the
Master Cylinders (pack of 10) treatment plan, will determine the cylinder offset, drill length (X) and depth stop position (SP#). These three pieces of information for each
implant length are provided on page 7.
CGS-YMC-10 3.8mm Master Cylinder (pack of 10)
CGS-GMC-10 4.6mm Master Cylinder (pack of 10)
CGS-BMC-10 5.8mm Master Cylinder (pack of 10)
*Laser-Lok 3.0 implant utilizes the same surgical protocol as the Tapered 3.0.
Offset, Drill Length and Stop Position 6mm Pilot Sleeve Dimensions
Pilot sleeves can be used when interdental space is limited due to patient anatomy or if a collision between the master cylinders is anticipated.
implant length (L)
7.5mm 9mm 10.5mm 12mm 15mm 18mm*
The implant length (L), requested in the treatment option 1
plan, will determine the cylinder offset, drill length offset: 8.03mm offset 10.53mm offset 9.03mm offset 10.53mm offset 11.53mm offset 7.98mm offset
(X) and depth stop position (SP#). Some implant
CGS-PS6-10 Pilot Drill Sleeve, 6mm (pack of 10)
X: 17mm drill 21mm drill 21mm drill 24mm drill 28mm drill 28mm drill
lengths have more than one option available. SP#: SP1 SP3 SP2 SP3 SP4 SP1
Choose the option that best fits the treatment plan
by factoring in occlusal space and crown height. option 2
offset: 12.03mm offset 12.03mm offset
X: 21mm drill — 24mm drill — — — Master Cylinder Collision Master Cylinder Collision Correction
SP#: SP4 SP4
ø2.03mm
ø4.19mm
Implant drivers feature 4 depth stop positions (SP1 - SP4)
to allow the implant to be placed to the correct depth. ø3.00mm
Drill length = drill guide height + offset + implant length* The laser-marked band above SP2 is used as a visual
indicator to assist in delineating the four stop positions.
*The 28mm drill used to place the 18mm implant will progress 0.54mm deeper than the final implant placement/depth.
6mm
Offsets for bone-level Implants offset
implant length (L) 6mm 7.5mm 9mm 10.5mm 12mm 15mm 18mm
7.87mm
3.99mm
Offsets for tissue-level implants 6mm 2.17mm
offset
overall implant length (OL) 9.86mm 11.36mm 12.86mm 14.36mm 17.36mm
implant length (L) 7.5mm 9mm 10.5mm 12mm 15mm 3mm
1.97mm 25.13mm 24mm 2mm
17mm 7.14mm 5.64mm
drill length
Cell phone:
Fax:
BioHorizons Lifetime Warranty on Implants and Prosthetics: All BioHorizons implants and prosthetic components include a Lifetime Warranty. BioHorizons implant or prosthetic components
will be replaced if removal of that product is due to failure (excluding normal wear to overdenture attachments).
Please reference the patient specific protocol for Patient ID BioHorizons Sample - Maxilla.
The protocol is based upon the submitted treatment plan for case ID XXXXX.
Additional Warranties: BioHorizons warranties surgical drills, taps and other surgical and restorative instruments.
Prior to placing the guide in the patient’s mouth, visually inspect the position of the master
cylinders and/or pilot sleeve to ensure it is placed according to the treatment plan. (1) Surgical Drills and Taps: Surgical drills and taps include a warranty period of ninety (90) days from the date of initial invoice. Surgical instruments should be replaced when they become worn,
dull, corroded or in any way compromised. Surgical drills should be replaced after 12 to 20 osteotomies.*
(2) Instruments: The BioHorizons manufactured instrument warranty extends for a period of one (1) year from the date of initial invoice. Instruments include drivers, implant site dilators and
BioHorizons tools used in the placement or restoration of BioHorizons implants.
Surgical Protocol for BioHorizons Guided Surgery Kit
implant label 3 5 7 8 11 12 Return Policy: Product returns require a Return Authorization Form, which may be acquired by contacting Customer Care. The completed Return Authorization Form must be included with the
implant type TLX5807 TLX4609 TLX3815 TLX3010 TLX4612 TLXP4610 returned product. For more information, please see the reverse side of the invoice that was shipped with the product.
implant length 7.5 9 15 10.5 12 10.5
guide site Complete Complete Complete Complete Pilot Complete Disclaimer of Liability: BioHorizons products may only be used in conjunction with the associated original components and instruments according to the Instructions for Use (IFU). Use of any non-
implant site preparation BioHorizons products in conjunction with BioHorizons products will void any warranty or any other obligation, expressed or implied.
drill length 17 21 28 21 24 21
drill guide/drill 2.0 2.0 2.0 2.0 2.0 2.0 Treatment planning and clinical application of BioHorizons products are the responsibility of each individual clinician. BioHorizons strongly recommends completion of postgraduate dental implant
drill guide/drill 2.5 2.5 2.5 2.5 2.5 education and adherence to the IFU that accompany each product. BioHorizons is not responsible for incidental or consequential damages or liability relating to use of our products alone or in
drill guide/drill 3.2 3.2 3.2 3.2 combination with other products other than replacement or repair under our warranties.
drill guide/drill 3.7 3.7 3.7
drill guide/drill 4.1 4.1 4.1 Distributed Products: For information on the manufacturer’s warranty of distributed products, please refer to their product packaging. Distributed products are subject to price change without
drill guide/drill 4.7 notice.
drill guide/drill 5.4
guided implant placement Validity: Upon its release, this literature supersedes all previously published versions.
depth position SP1 SP3 SP4 SP2 SP2
Availability: Not all products shown or described in this literature are available in all countries. BioHorizons continually strives to improve its products and therefore reserves the right to improve,
implant driver 5.4 4.6 3.8 3.8 4.6
modify, change specifications or discontinue products at any time.
Any images depicted in this literature are not to scale, nor are all products depicted. Product descriptions have been modified for presentation purposes. For complete product descriptions and
Clinician judgement, as related to individual patient presentations, must always supersede recommendations in any BioHorizons Instructions for Use (IFU).
additional information, visit store.biohorizons.com.
Additional technical information is available upon request from BioHorizons, or may be viewed and/or downloaded at www.biohorizons.com,
* Heat production by 3 implant drill systems after repeated drilling and sterilization. Chacon GE, Bower DL, Larsen PE, McGlumphy EA, Beck FM. J Oral Maxillofac Surg. 2006 Feb;64(2):265-9.
2300 Riverchase Center • Birmingham, Alabama 35244 • 866.872.9785 • 205.967.7880 • fax 205.870.0304
BioHorizons products are available in over 85 markets worldwide • www.biohorizons.com
shop online at
store.biohorizons.com
L02021
REV D JUN 2018