Nomenclature
HXE V 400 T S TT F / E2614 P H 2 / C2614 J K 2
Number of Passes(1,2,3)
High-efficiency
Condenser Tube Type Code
magnetic centrifugal chiller
K-0.635mm; M-0.711mm
Start model code, Condenser Tube Count Code
V- VFD control
Compressor code:
350/400/700 Condenser Code
Number of
refrigeration circuit Evaporator Tube Type Code
(S means single) H-0.635mm; J-0.711mm
01
Technology Features
Superior Efficiency
As the global HVAC leader, Daikin has perfectly combined the most advanced
technology with water cooled chillers to provide excellent performance.
Magnetic bearing centrifugal chiller has been designed with oil free system, resulting in
eliminating oil contamination in the refrigerant and heat transfer surfaces to provide outstanding
operating efficiency without any performance penalty compared to conventional oil-system
chiller. Our magnetic bearing centrifugal chiller also integrates VFD technology. It allows the
compressor to unload smoothly from maximum to minimum load for superior part-load
performance in comfort cooling applications. An additional flash tank type economizer has
contributed to efficiency improved by operating the two-stage compression system. It makes
chiller efficiency lower to 0.52kw/RT and IPLV lower to 0.29kw/RT.
Oil-free design is no need for oil management systems to effectively improve compressor and
system reliability and also avoid performance degradation because of no oil contamination in the
refrigerant.
02
Trouble-free ownership
Low noise
The chiller sound pressure level is as low as
77.5 dB(A), creating a quiet environment. No
mechanical noise makes the chiller become
the quietest chiller. Therefore, this quiet
operation makes this ideal option for sound
sensitive environments such as schools,
concert halls and museums.
Compact Design
The compact size of the chiller makes it
2071mm available for replacement, retrofit and
energy upgrade projects. In addition,
the smaller footprint saves the chiller
plant room space.
1341mm
3556mm
Energy cost
Reduced annual energy costs due to outstanding part-load efficiency since chillers spend about 99% of
their operating hours at part-load conditions.
This chiller has been proven effective in thousands of installations around the world. It is more energy
efficient than normal centrifugal chillers.
Operational cost
Sustainable performance assured for the operating life of the chiller. The positive pressure, oil-free design
eliminates performance degradation because of no oil contamination in the refrigerant.
Magnetic bearing chiller is oil free system without any need for oil charge, oil replacement, oil filter replacement,
etc. The results are reduced operational costs and maintenance savings every year.
03
Control Features
Daikin employs microprocessor technology
into the MicroTech Ⅱ control system to
provide the optimum chiller control.
M i c r o Te c h controller incorporate
microprocessor provides all monitor and
control function for the efficient and safety
operation. The control contains many
energy-saving features to keep your chiller
running efficiently day after day.
User-friendly Operation
HXE provides an easy operator interface, with key operating parameters on the screen.
Operation Simplicity allows you to change the set points easily by pressing set button from any
screen.
Alarm history is easily accessed through intuitive touch-screen buttons. Operator can monitor
all operating conditions by using the unit-mounted HMI. The occurred Alarms are retained in the
controller's memory to aid in troubleshooting and fault analysis. Alarm history lists the alarms
with the most current on top with date stamp, action taken and the cause of the alarm. You can
download the chiller operating manual via USB.
All MicroTech II controllers offer simple and inexpensive flexibility to use the Building
Automation System. The exclusive control feature provides seamless integration and
comprehensive monitoring, control, and two-way data exchange with industry standard
protocols such as LONWORKS, Modbus or BACnet. The BAS communication module can be
ordered factory mounted with your chiller. It is easy to integrate into your building automation
system, providing comprehensive data exchange and point list for system integration,
equipment monitoring and alarm notification.
04
Technical Data
Power Evap. Evap. Cond. Cond Rated Startup In- Chiller Operation
Cooling capacity Efficiency
Consumption Flow Rate Pressure Drop Flow RatePressure Drop Load Amps rush Current Weight Weight
Model
HXEV350SSTTF/E2209-RH/C2009-MK 100.0 351.7 53.79 0.5379 6.539 15.14 15.4 18.77 14.7 96.52 2.000 2969 3400
HXEV400SSTTF/E2209-QH/C2009-KK 150.0 527.5 87.42 0.5828 6.034 22.71 21.0 28.47 24.6 145.9 2.000 3035 3508
HXEV700SSTTF/E2209-PH/C2009-JK 200.0 703.2 111.7 0.5582 6.300 30.28 26.0 37.73 29.4 185.8 2.000 3121 3658
HXEV350DSTTF/E2210-PH/C2210-KK 200.0 703.2 108.9 0.5447 6.456 30.28 28.9 37.61 30.4 195.2 2.000 3819 4363
HXEV400DSTTF/E2212-QH/C2212-KK 250.0 879.0 135.6 0.5425 6.483 37.85 66.2 46.98 50.4 229.8 2.000 4086 4673
HXEV700DSTTF/E2612-PH/C2212-JK 300.0 1055 164.5 0.5483 6.414 45.43 34.2 56.46 52.6 278.0 2.000 4752 5558
HXEV700DSTTF/E2612-QH/C2612-KK 350.0 1231 193.1 0.5516 6.376 53.00 55.6 65.92 46.2 323.1 2.000 5051 5938
HXEV700DSTTF/E2612-PH/C2612-JK 400.0 1407 229.6 0.5741 6.126 60.56 56.3 75.75 46.6 381.7 2.000 5181 6156
HXEV350TSTTF/E2614-RH/C2614-MK 300.0 1055 159.6 0.5319 6.612 45.43 61.5 56.23 51.0 286.7 2.000 6119 7032
HXEV400TSTTF/E2614-QH/C2614-MK 350.0 1231 184.0 0.5257 6.690 53.00 64.5 65.50 66.0 314.5 2.000 6187 7139
HXEV400TSTTF/E2614-PH/C2614-KK 400.0 1407 217.6 0.5441 6.463 60.56 65.3 75.20 66.8 366.9 2.000 6340 7387
HXEV700TSTTF/E2614-PH/C2614-JK 450.0 1583 244.7 0.5438 6.468 68.14 80.1 84.60 65.0 413.8 2.000 6430 7537
HXEV700TSTTF/E3014-PH/C2614-JK 500.0 1758 271.3 0.5426 6.481 75.71 56.1 93.97 77.7 455.7 2.000 7005 8247
HXEV700TSTTF/E3014-QH/C3014-KK 550.0 1934 302.7 0.5504 6.389 83.28 79.5 103.6 70.6 505.6 2.000 7535 8900
HXEV700TSTTF/E3014-PH/C3014-JK 600.0 2110 339.3 0.5655 6.219 90.85 76.9 113.4 70.7 564.3 2.000 7701 9162
Notes:
1. Above chiller cooling capacity is based on AHRI condition:
Chilled water outlet temperature 6.7°C, Chilled water inlet temperature 12.2°C;
Cooling water inlet temperature 29.4°C. Cooling water outlet temperature 34.6°C;
Evaporator-side water fouling factor: 0.018 m °C/kW, condenser-side water fouling factor: 0.044 °C/kW;
2. Above chiller is recommended, please contact local sales for other specific models;
3. The starting current is smaller than full load current; the power distribution should according to the full load current.
05
Technical Data
Power Evap. Evap. Cond. Cond Rated Startup In- Chiller Operation
Cooling capacity Efficiency
Consumption Flow Rate Pressure Drop Flow RatePressure Drop Load Amps rush Current Weight Weight
Model
HXEV350SSTTF/E2209-RH/C2009-MK 100.0 351.7 57.32 0.5732 6.136 16.82 18.5 19.57 15.5 102.1 2.000 2969 3400
HXEV400SSTTF/E2209-QH/C2009-KK 150.0 527.5 92.16 0.6144 5.724 25.23 25.2 29.64 25.9 153.5 2.000 3035 3508
HXEV700SSTTF/E2209-PH/C2009-JK 200.0 703.2 118.3 0.5913 5.948 33.65 31.2 39.31 31.0 118.3 2.000 3121 3658
HXEV350DSTTF/E2210-PH/C2210-KK 200.0 703.2 116.2 0.5808 6.056 33.65 34.6 39.21 32.0 206.6 2.000 3819 4363
HXEV400DSTTF/E2212-QH/C2212-KK 250.0 879.0 144.9 0.5795 6.069 42.06 79.4 48.99 53.2 244.2 2.000 4086 4673
HXEV700DSTTF/E2612-PH/C2212-JK 300.0 1055 178.6 0.5952 5.909 50.47 41.1 59.02 55.7 300.1 2.000 4752 5558
HXEV700DSTTF/E2612-QH/C2612-KK 350.0 1231 207.3 0.5922 5.939 58.88 66.7 68.80 48.8 345.8 2.000 5051 5938
HXEV700DSTTF/E2612-PH/C2612-JK 400.0 1407 243.1 0.6078 5.786 67.29 67.5 78.92 49.1 403.5 2.000 5181 6156
HXEV350TSTTF/E2614-RH/C2614-MK 300.0 1055 170.7 0.5690 6.181 50.47 73.8 58.64 53.8 304.3 2.000 6119 7032
HXEV400TSTTF/E2614-QH/C2614-MK 350.0 1231 197.4 0.5640 6.236 58.88 77.3 68.33 69.6 335.2 2.000 6187 7139
HXEV400TSTTF/E2614-PH/C2614-KK 400.0 1407 231.8 0.5796 6.068 67.29 78.3 78.38 70.4 389.2 2.000 6340 7387
HXEV700TSTTF/E2614-PH/C2614-JK 450.0 1583 265.7 0.5905 5.956 75.71 96.0 88.42 68.9 446.8 2.000 6430 7537
HXEV700TSTTF/E3014-PH/C2614-JK 500.0 1758 292.5 0.5851 6.011 84.12 67.3 98.11 82.1 489.4 2.000 7005 8247
HXEV700TSTTF/E3014-QH/C3014-KK 550.0 1934 323.7 0.5885 5.976 92.53 95.4 108.0 74.6 539.1 2.000 7535 8900
HXEV700TSTTF/E3014-PH/C3014-JK 600.0 2110 359.9 0.5998 5.863 100.9 92.2 118.2 74.5 597.5 2.000 7701 9162
Notes:
1. Above chiller cooling capacity is based on user condition:
Chilled water outlet temperature 7°C, Chilled water inlet temperature 12°C;
Cooling water inlet temperature 32°C. Cooling water outlet temperature 37°C;
Evaporator-side water fouling factor: 0.018 m °C/kW, condenser-side water fouling factor: 0.044 °C/kW;
2. Above chiller is recommended, please contact local sales for other specific models;
3. The starting current is smaller than full load current; the power distribution should according to the full load current.
06
Major Components
Evaporator
Condenser
Power Panel 3# Power Panel 2# Economizer
Power Panel 1#
Outlet
R e l i e f Va l v e s
Inlet
OITS
Outlet
Inlet
Control Box
07
Dimensions
AA
AA
d
C
a
BB
BB
b
K
D
H H
J G
A E
B
HXEV***SSTT*/E2209/C2009 3268 1259 2091 2808 1023 102 1146 160 217 168 217 421 143 140
Notes:
1、A、B、C dimension deviation ± 13mm;
2、Above dimension base on 2 pass water flow, Please contact your Daikin representative for other passes.
08
Dimensions
Outlet
AA
AA
Inlet
C
Outlet
BB
BB
Inlet
K
H H
D
J G
E
A
B
HXEV***DSTT*/E2210/C2210 3569 1344 2071 3108 1023 102 1126 160 217 168 217 401 160 168
HXEV***DSTT*/E2610/C2210 3665 1422 2239 3108 1110 102 1264 180 305 219 217 401 160 168
HXEV***DSTT*/E2610/C2610 3665 1427 2389 3108 1198 102 1415 180 305 219 304 489 180 219
HXEV***DSTT*/E2212/C2212 4152 1344 2071 3694 1023 102 1126 160 217 168 217 401 160 168
HXEV***DSTT*/E2612/C2212 4250 1422 2239 3694 1110 102 1264 180 305 219 217 401 160 168
HXEV***DSTT*/E2612/C2612 4250 1427 2389 3694 1198 102 1415 180 305 219 304 489 180 219
Notes:
1、A、B、C dimension deviation ± 13mm;
2、Above dimension base on 2 pass water flow, Please contact your Daikin representative for other passes.
09
Dimensions
Outlet
AA1
AA2
Inlet
C
Outlet
BB1
BB2
Inlet
K
H G
D J
E
A B
HXEV***TSTT*/E2614/C2614 4899 1402 2423 4345 1198 102 1435 180 180 219 304 305 509 180 180 219
HXEV***TSTT*/E3014/C2614 4940 1474 2454 4345 1226 102 1415 206 206 273 304 332 509 180 180 219
HXEV***TSTT*/E3014/C3014 4940 1483 2593 4345 1279 102 1547 206 206 273 332 332 590 206 206 273
Notes:
1、A、B、C dimension deviation ± 13mm;
2、Above dimension base on 2 pass water flow, Please contact your Daikin representative for other passes.
10
Options
Insulation 20mm Insulation on Evaporator and Cold Surface 40mm Insulation on Evaporator ①
②
Filter None Active Power Filter / Passive Filter
Startup Range
NOTE: Δt=5℃
40
Condenser entering water temp ℃
(8,30) (30,30)
30
20
(30,20)
10
(8,8)
0
0 10 20 30 40
11
Operation Range
CLWT
50
(18,45)
Condenser leaving water temp ℃
(3,40)
40
30
(18,30)
20
(3,18) (8,18)
10 ELWT
-5 0 5 10 15 20
Application Standard
The standard running condition of the water chiller is as follows:
Supply Voltage Rated voltage ± 10%
Nitrogen 1 mg/m3
Heat Exchange Tube Waterside Pressure Standard chiller 1.0MPa (may be designed follow the customer’s requirements)
12
Water Quality Management
During the unit running, the water quality of the cooling and chilled water will directly affect the
machine's performance and lifetime, so it is necessary to survey the water quality beforehand and
conduct water quality control as the unit runs.
The following table contains some parameters of the water quality of open system:
Item
Item Unit Reference
Value Corrosion Scaling
PH(25℃) _ <6.5~8.0 O O
-
Chloridion Cl mg(Cl - )/L <200 O
Base Items
Sulfateion SO 2-
4 mg SO 2-4 /L <200 O
Notes:
1. The “O” in the table indicates the relevant factors with corrosion or scaling.
2. We recommend you add water process device and contact Daikin professional servicer to deal with it.