You are on page 1of 7

Tendon Profile

Non-composiite Composite
Location Slope,α dp = e + yt + hf
Eccentricity, e Eccentricity, e
  in in deg in
1 2.575 8.485 4.34 44.355
2 9.772 19.222 3.72 52.142
3 25.416 34.866 1.86 67.786
4 30.63 40.08 0.00 73
Approximate Loss of Prestress
Losses Stress immd. Tendon force after Tendon force
Stress after Stress after
Location Prior to instantaneous after all
Total Inst. Long Term inst. Loss all losses
transfer, fpbt loss, Pt losses, PF
  ksi ksi ksi ksi ksi kip kip
1 19.98 19.98 218.7 198.72 178.74 1523.19 1370.04
2 19.98 19.98 218.7 198.72 178.74 1523.19 1370.04
3 19.98 19.98 218.7 198.72 178.74 1523.19 1370.04
4 19.98 19.98 218.7 198.72 178.74 1523.19 1370.04
Stress Check at Transfer
Girder Bottom Top
Non-comp. Horizontal self- stress, - Comm. stress, - Comm.
Prestressing Slope,
Loc. Eccentricity, component, weight Ptx/A - (OK/Not Ptx/A + (OK/Not
force, Pt α
e Ptx= Pt cosα moment, Ptxe/Sb + OK) Ptxe/St - OK)
M Mg/Sb Mg/St
  in kip deg kip kip-ft ksi   ksi  
1 2.575 1523.19 4.34 1518.82 0 -0.88 OK -0.583 OK
2 9.772 1523.19 3.72 1519.98 673.72 -1.61 OK -0.958 OK
3 25.416 1523.19 1.86 1522.39 2004.7 -2.00 OK -0.588 OK
4 30.63 1523.19 0.00 1523.19 2448.31 -2.13 OK -0.464 OK
Girder Bottom Tension Check

Loc. PF α PFX = PFcosα e Sb Sbc MDNC MDC MLL Mpd fbot,1 0.19√(f'c) OK/Not OK
  kip deg kip in in3 in3 kip-ft kip-ft kip-ft kip-ft ksi ksi  
33105.8
1 1370.04 4.34 1366.11 2.575 25598.9 0 0 0 0 -0.79 0.484 OK
9
18613.9
2 1370.04 3.72 1367.16 9.772 20438.2 1009.6 401.94 597.86 54.81 -0.61 0.484 OK
4
18613.9
3 1370.04 1.86 1369.32 25.416 20438.2 3053.43 1228.41 1794.23 167.51 0.74 0.484 Not OK
4
18613.9
4 1370.04 0.00 1370.04 30.63 20438.2 3734.65 1503.9 2163.39 205.08 1.18 0.484 Not OK
4

Girder Bottom Compression Check


Loc. PF α PFX = PFcosα e Sb Sbc MDNC MDC fbot,2 0.45f'c OK/Not OK
  kip deg kip in in3 in3 kip-ft kip-ft ksi ksi  
1 1370.04 4.34 1366.11 2.575 25598.9 33105.89 0 0 -0.79 2.925 OK
2 1370.04 3.72 1367.16 9.772 20438.2 18613.94 1009.6 401.94 -0.95 2.925 OK
3 1370.04 1.86 1369.32 25.416 20438.2 18613.94 3053.43 1228.41 -0.27 2.925 OK
4 1370.04 0.00 1370.04 30.63 20438.2 18613.94 3734.65 1503.9 -0.04 2.925 OK
Slab Top Compression Check
Loc. Stsc MDC MLL MPD ftop,s 0.45f'c,slab OK/Not OK
  in3 k-ft k-ft k-ft ksi ksi  
1 39806.45 0 0 0 0.00 1.8 OK
2 26054.99 401.94 597.86 54.81 -0.38 1.8 OK
3 26054.99 1228.41 1794.23 167.51 -1.15 1.8 OK
4 26054.99 1503.9 2163.39 205.08 -1.40 1.8 OK
Flexural Capacity of Flanged Section
Strength-I,
Loc. dp bw c (T-beam) c (Rect.) c fps a=β1c Mn Mn ≥ M u
Mu
  k-ft in in in in in ksi in k-ft Y/N
1 0 44.355 28 8.31 8.93 8.93 254.78 6.47 6668.95 Y
2 2941.83 52.142 10 6.74 9.01 9.01 256.94 6.53 7987.99 Y
3 8893.03 67.786 10 7.10 9.11 9.11 259.84 6.60 10674.21 Y
4 10824.85 73 10 7.19 9.13 9.13 260.54 6.62 11570.57 Y

Minimum Flexural Reinfocement

Loc. Sc = Sbc Snc = Sb MDNC PFX A e fcpe Mcr 1.33Mu Mr,min Mn Mn ≥ Mr,min
  in3 in3 k-ft kip in2 in ksi k-ft k-ft k-ft k-ft  Yes/No
25598.8
1 33105.89 0 1366.11 2093 2.575 -0.790 5098.71 0 0 6668.95 Yes
7
20438.2
2 18613.94 1009.6 1367.16 1190 9.772 -1.803 4684.36 3912.63 3912.63 7987.99 Yes
2
20438.2
3 18613.94 3053.43 1369.32 1190 25.416 -2.854 6660.03 11827.73 6660.03 10674.21 Yes
2
20438.2
4 18613.94 3734.65 1370.04 1190 30.63 -3.205 7319.77 14397.05 7319.77 11570.57 Yes
2