Survey: "3D- CRT Photon Planning Competency Evaluation"


Reviewer: Clinical Instructors (KENDRA, Tom)
Reviewee: Students (Edwards, Ryann)
Survey Period: 8/17/2023
Completed: 8/17/2023 5:51:05 PM CT

1. Select the external beam photon planning competency from the drop down menu below:

Pelvis (GYN or other)

2. If Other competency, please specify the type here:

NR

about:blank 1/3
8/18/23, 11:24 AM Typhon Group - EASI System
3. Please assign each task a score of Satisfactory or Unsatisfactory.
Unsatisfactory in any essential task constitutes competency failure.
The student will repeat the competency at a later date.

Discusses the plan prescription with the physician. Satisfactory [2 pts]

Loads the patient imaging studies into the planning computer. Satisfactory [2 pts]

Contours the appropriate anatomy on the image data set. Satisfactory [2 pts]
Additional Comments:  Second nature and identifies all critical
structures in the pelvis. Including high risk surface areas such
as genitalis and skin between target and surface posterior to
sacrum.

Successfully places the isocenter using simulation data. Satisfactory [2 pts]

Correctly generates plan using blocks, wedges, segmented Satisfactory [2 pts]


fields. Additional Comments:  Created 2 plans, one with wedges on
the lateral field and one with field in field technique. Compared
both plans side by side and chose the better plan.

Generates plan with appropriate weighting. Satisfactory [2 pts]


Additional Comments:  Hotter spots in all four corners of the
box target area indicates correct weighting of the beams.

Generates plan with appropriate energies. Satisfactory [2 pts]


Additional Comments:  Used mixed energies with 10MV Ant,
6MV Post, and 18 Laterals.

Accurately generates/evaluates plan DVH or composite DVH Satisfactory [2 pts]


(for correct # of fractions).

Communicates effectively with physician for plan review and Satisfactory [2 pts]
makes changes as requested.

Exports/Prints appropriate plan data. Satisfactory [2 pts]

Performs a verification calculation for plan MU settings. Satisfactory [2 pts]


Additional Comments:  Second calculations done with MU
Check. Understands factors that are used in hand calculations.

Enters correct parameters for the patient chart. Satisfactory [2 pts]

Performs pretreatment checks/calculations. Satisfactory [2 pts]

Utilizes respiratory gating information to determine field N/A


parameters.

Observes patient treatment. Satisfactory [2 pts]

Mean: 2.00 of 2  Points: 28  Score: 100.0%

4. Overall rating:

Pass [2 pts]
If applicable, please specify reason for failure:  Good understanding of this treatment.

Mean: 2.00 of 2   Points: 2  Score: 100.0%

about:blank 2/3
8/18/23, 11:24 AM Typhon Group - EASI System

Total points for all rating scale questions: 30


Mean percentage score for all rating scale questions: 100.0%
(Each main question equally weighted)
Responses as of 8/18/2023 11:23:06 AM CT