Professional Documents
Culture Documents
Ats-Aijes 2018 (Ta)
Ats-Aijes 2018 (Ta)
FEITENG
SUZHOU FEITENG ELECTRIC CO.,LTD.
Add:Xiangcheng District Beiqiao Jinfeng Industrial Park of Suzhou City
Tel:(0512)65761506、65497851、65991720
Fax:(0512)65498190
Service Contact:(0512)65994559
Add:No.13, Second Street, Ganzhou, Situn District,Taizhong City
Tel:00886-(04)23162179
AIJES
Fax:00886-(04)23132182
Http:www.pheteng.com
PRODUCTS
AIJES PRODUCTS CATALOG
E-mail:feiteng@pheteng.com
SUZHOU FEITENG ELECTRIC CO., LTD. COPYRIGHT (C) ALL 2014 SUZHOU FEITENG APPLIANCE CO., LTD.ALL RIGHTS RESERVED
CATALOG
DUAL POWER
AUTOMA TIC
TRANSFER SWITCH
AIJES
PRODUCTS
CATALOG
DUAL POWER
AUTOMA TIC
TRANSFER SWITCH
COMPANY
PROFILE Product Catalog
DUAL POWER AUTOMATIC TRANSFER SWITCH
Suzhou FEITENG Electric Co.,LTD. was founded in 1994, is a Taiwan-owned FEITENG Electric Co., LTD.
in the mainland to set up a low-voltage electrical business. The company is located in Suzhou, Wuxi, W series dual power automatic
Changshu intersection - North Town, Suzhou is only three kilometers away from the beltway, geographic transfer switch
location.
After ten years of experience in the development, Suzhou FEITENG Electric has grown (dual power 1.the product code and meaning
automatic transfer switch) is the largest one of the manufacturers of PC-class ATS. Company employees 2. W-2 two-stage switch parameters
150 people, including engineering staff of nearly 20 percent, more than 80 percent of college and higher 3. W-N3 three-stage switch parameters
education staff of the total engineering manpower, the factory area 11,250 square meters, which is the
4.dimensions and mounting dimensions
company's fast, robust, innovation and sustainable development a solid guarantee.
The company has long been engaged ATS dual power automatic transfer switch, ATS controllers, 5.manually and precautions
residual current monitoring system, fire detection, molded case circuit breakers, miniature circuit 6. internal switch wiring diagram
breakers, earth leakage circuit breakers and Circuit Breaker and other low-voltage electrical and electronic
equipment development and production manufacturing, complete specifications, comprehensive
product that can meet the needs of each user. The company now has injection workshop, stamping W2R series dual power automatic
workshop, mold shop, spot welding workshop, electronics workshop and various product assembly transfer switch
workshop, advanced manufacturing equipment, including 20 sets of spot welding, punching, equipment,
vehicles, milling metal processing equipment more than 30 Taiwan, as well as the electrical properties of
test equipment, product life test equipment, measuring and testing equipment, product aging test
chamber, and electrical properties laboratory.
We follow the "careful planning, strict control, the pursuit of a better, to provide customers with the
desired products and services," the quality policy, the establishment of a sound quality assurance system,
through the "ISO9001-2008" quality system certification, and has made Suzhou City "Consumer
confidence enterprise" and Suzhou City Electric Industry Association, "executive director units," the
glorious title. The company also established a nationwide sales and service network, and in good faith,
the Three Guarantees products, commitment to the province two days in the province one day on-site
service.
Suzhou FEITENG Electric Co., Ltd. Mr. Huang Zheyong staff welcome business colleagues at home and
abroad to visit our company, study, business negotiations, let us hand in hand, a win-win for a better
tomorrow!
AIJES
PRODUCTS
CATALOG
DUAL POWER
AUTOMA TIC
TRANSFER SWITCH
1-2
turn control
appliances Note: T0.95 ceiling ≈6Pe≤300ms. DC-13 power-on time when more than 0.05s T0.95 least TO.95.
DC-13 Load control solenoid
W
TRANSFER SWITCH
10
1
1. A power supply side of the
main circuit terminals
2. Power-off indicator window
2
3. Manually operated square
9
shaft
W series dual power switching equipment belonging PC level, it points to W2 W-N3 two. 3
4. Nameplate
W-2 for the two-stage automatic transfer switch, when the switch is connected to the 5. Control power supply terminal 8
switching signal does not stop in the middle of the open position immediately switched to the 6. Load side of the main circuit 4
other power supply, current specifications for a 500A 20A from a power supply. terminals
W-N3 for the three-stage automatic transfer switch, the switch after receiving the converted 7. B power supply side of the
5
signal can be immediately (or after a predetermined delay time) from a transducer connected main circuit terminals
to another power supply, you can pick from a power exchange to any intermediate position 8. Interrupter cover
does not disconnect the power interlinked. 20A current specifications for a 5000A. 9. Auxiliary contact cover 7
10. Across the phase plate
6
3-4
short, less contact loss.
Frame current Multi-piece main arc contacts: contact surface contact area and increase the contact pressure, without
Product Series Rated operating current le Poles Wiring Function number Frame current (A) 63 125 250 500
(A) (P)
W-N3 20、40、63、 80
2、3、4 F、B Wiring The front plate
W-2 、100…
Poles 2P 3P 4P 2P 3P 4P 2P 3P 4P 2P 3P
63 20、40、63、
Weight (kg) 4.5 5 5.5 5 6.3 6.8 6 6.6 7.3 11 15
Operating current
125 80、100、125 DC110V/125V 6 6 8 6 6 8 6 8 10 10 10
3:Three Level
Short time withstand
4:Four Level 10kA 15kA 20kA
800 630、800 B:After the current
II Automatic type
board Wiring
Rated conditional s
1250 1000、1250 hort-circuit current 50kA 65kA
(fuse for protection)
Performance
2500 1600、2000、2500
AC-33B(10IeConnect.10IeBreaking)cosΦ=0.35(Ie≤100A,cosΦ=0.45)
Breaking capacity
4000 3150、5000 DC-33B(4IeConnect.4IeBreaking)L/R=2.5ms
A→B
5000 5000 Conversion
time ≤0.2s
B→A
Use Lifetime Electrical life of 6,000 times, the mechanical life of 20,000 times
Note: 1) rated working voltage AC660V / 690V, and DC125V / 250V and control voltage
AC100V, 110V, and DC110V, 125V and other voltage specification of switching equipment Operating cycle frequency 120 times / hour
5-6
capacity AC: 110V5A / AC: 220V3A DC: 200V0.2A
Frame current 63A 125A 250A 500A 800A 1250A 1600A 2500A 3150A 4000A 5000A
Double throw
Vote count Double throw
Poles 2P 3P 4P 2P 3P 4P 2P 3P 4P 2P 3P 4P 2P 3P 4P 2P 3P 4P 2P 3P 4P 2P 3P 4P 2P 3P 4P 3P 4P 3P 4P
Weight(kg) 5.5 5.8 6.4 6 6.5 7.2 6 7.1 7.7 11 15 18 25 38 43 37 46 55 36 54 68.6 95 115 135 110 124 140 207 265
12 12 16 14 16 18 16 20 24 20 24 28 32 36 36 38
Operating current
DC110V/125V 6 6 8 6 6 8 6 8 10 10 10 14 12 12 12
12 12 16 14 16 18 16 20 24 20 24 28 32 36 36 38
AC100V/110V 6 6 8 6 6 8 6 8 10 10 10 14 12 12 12
AC200V/ 6 6 8 7 8 9 8 10 12 10 12 16 16 18 18 20
3 3 4 3 3 4 5 5 5 5 5 6 6 6 6
(A) 220V/230V
Tripping current
DC110V/125V 2 3 4 4 6
AC100V/110V 2 3 4 4 6
Short time withstand current 10kA 15kA 20kA 25kA 32kA 40kA 50kA
Rated conditional
short-circuit current 100kA 120kA 120kA 120kA
(fuse for protection)
Rated conditional
short-circuit current 50kA 65kA 50kA 50kA
(fuse for protection)
Performance
AC-33B(10IeConnect.10IeBreaking)cosΦ=0.35(Ie≤100A时,cosΦ=0.45) AC-33B(10IeConnect/10IeBreaking)cosΦ=0.35
Breaking capacity
DC-33B(4IeConnect.4IeBreaking)L/R=0.25ms DC-33B(4IeConnect.4IeBreaking)L/R=2.5ms
Time Conversion
A→B
≤0.2s ≤0.2s
B→A
7-8
Auxiliary switch A, B are two normally open power supply; switching capacity AC: 110V5A / AC: 220V3A DC: 200V0.2A A, B power supply side are two normally open and two normally closed; switching capacity AC: 110V5A / AC: 220V3A DC: 200V0.2A
Table 4
Table 5 Table 7
Table 6 Table 8
9-10
Note: The drawings A, B size Table 6.
Note: The drawings A, B size Table 8.
Table 9
Norm
Safe distance
Ue
Size mm 400V 690V
S1 45 90
S2 430 450
Safe distance
Ue
Size mm 400V 690V
S1 50 100
S2 560 600
Former 3150A (4P), 4000A and 5000A automatic transfer switch has been configured four lifting rings, the rings must be checked are tightened
Note: The drawing A-F, S1, S2 size Table 9. on the mounting rail switches before lifting, and check the carrying capacity of the rope should not be less than 500kg, formally lifting also:
Notes hanging must try to determine the center of gravity position switch, to prevent gravity grasp allowed to cause rollover, slipping and
other major accidents.
Table 10 Table 11
Norm Norm
Safe distance
Ue
Size mm 400V 690V
S1 50 100
S2 560 600
11-12
AIJES PRODUCTS CATALOG
Note: The drawing A-F, H, I, S1, S2 size Table 10.
The company's W-series switch in the electric operation to ensure its on-off capability, but due to the
operation manual of human factors, there are differences in the switching speed can not be guaranteed.
1)W-N3-type internal wiring diagram (two power OFF state)
Because manual transfer switch load will cause the switching transition when the silver alloy contact damage,
it is only in the manual operation of the operating mechanism, contact inspection, maintenance or electrically
operated when a fault event.
Load side
TC = trip coil
1) artificial escape method (only applies to W-N3-type, W-2 type conversion not only trip) 51 = Rectifier
LS = selector switch
ATS1, ATS2 two A power disconnect
By removing the operating handle terminals
state to a screwdriver into the hole BTS1, BTS2 = B power disconnect
and to the left TRIP internal terminals
pressure to escape. (Requested by AX, BX = control switch
the ON / OFF switch indicator
AUX = auxiliary switch
window to confirm whether the
A1 A2 = A supply side an input
trip)
terminal
A two B1 B2 B-side power input
terminal
AT1 a side trip AT2 = A power supply
2) A supply-side input method Note: W a need to operate an N3-type) can be carried out after the completion of a 2 and W-type terminal
operation is not required. " B supply-side BT1 a side trip BT2 = B power supply
terminal
A supply-side
Manual operation of the W-N3: pull up the handle, View ON / OFF indicator Remove the operating
operating handle into the you can invest. W-2: pull window to confirm input. handle after handling.
left front end of the the handle down to hear
Load side
operation side of the axis the "click" "click" twice can.
gap.
3) B-side power input method Note: W a need to operate an N3-type) can be carried out after the completion of, and W-2
type need not operate a)
13-14
Manual operation of the W-N3 SELECT screwdriver W-N3 keep the View ON / OFF indicator A1-A2: A supply-side input terminal
operating handle into the into the right hole and to screwdriver in a position window to confirm input; B1-B2: B-side input terminal of the
left front end of the internal pressure. to suppress. At the same remove the operating
operation side of the axis W-2: Just pull down the time pull up the handle handle after handling.
B supply-side power supply
Operating handle
See the application and selection
① ② ③ ④ ⑤ ⑥ ⑦ t
① ② ③ ④ ⑤ ⑥ ⑦ t
15-16
2000A 3000A 320 50(52) 19.1 25 15 Φ8 50 9(11)