Professional Documents
Culture Documents
How To Change The Full Circle Threshold On A HDS Open Series Techno CNC Systems Router
How To Change The Full Circle Threshold On A HDS Open Series Techno CNC Systems Router
How to change the Full Circle Threshold on a HDS Open Series Techno CNC Systems Router
29 Trade Zone Drive, Ronkonkoma NY 11779
Office: (631) 648-7481
www.technocnc.com
1. On the Process Explorer, select the ODM button, shown below in the red box.
2.
In the network pane on the left, navigate to 192.168.2.1>AMP>AMP3 (Or whatever amp has the blue clock next to
it)>[1] Process
Select “Process Variables” tab from the main screen (top red square) then find “Full Circle Threshold” and change
the value to 0.002.