Professional Documents
Culture Documents
Class Presentation - Abstract11
Class Presentation - Abstract11
JOB No.
PROJECT "MULTI - PURPOSE TOWER" AT DARLEY ROAD, COLOMBO, SRI LANKA
O6118
REV. No.
JOB NO. O6118 - C - TB - 01 - BQ - 0002
0
CALCULATED
DICIPLINE Structural (BOQ of Substructure)
Corewalls/Shear Walls
i) Core Walls / Shear Walls from Raft Level - Ground Level m3 819
Columns
i) Columns from Raft Level - Ground Level m3 384
2.4 Providing ready mixed concrete to site, taking delivery, laying,
compacting and curing concrete grade M60 as per specifications
using coarse graded aggregate of 20mm and down size
aggregate of approved properties for the following members of all
shapes, at all levels including necessary formwork, centering,
shuttering, all lead and lifts, tools & plants, pumping the concrete
to all levels, vibrating, curing etc. complete but excluding cost of
reinforcement. Depending on the size and location, the maximum
depth of concreting will be decided by Engineer in casting at a
time. Rate to include for all necessary formwork
Substructure:
i) Floor Slab m3 2,211
ii) Floor Beams m3
753
2.5 Providing ready mixed concrete to site, taking delivery, laying,
compacting and curing concrete grade M40 as per specifications
using coarse graded aggregate of 20mm and down size
aggregate of approved properties for the following members of all
shapes, at all levels including necessary formwork, centering,
shuttering, all lead and lifts, tools & plants, pumping the concrete
to all levels, vibrating, curing etc. complete but excluding cost of
reinforcement. Depending on the size and location, the maximum
depth of concreting will be decided by Engineer in casting at a
time. Rate to include for all necessary formwork
Substructure:
i) Raft Slab m3 9,777
ii) Retaining Walls m3 6,092
iii) Ramp Beam m3 119
iv) Ramp Slab m3 137
v) Staircase m3
41
vi) Water Retaining Structures m3 102
vii) Lintel m3 6
3.0 FORM WORK
Form work for Reinforced Cement Concrete (RCC)
3.1 Supplying, fabricating, erecting and fixing in position centering
and shuttering to correct line and levels including
strutting,propping, wtc. With necessary bracings in all axes to
give a stable assembly with provision for making the joints in the
shuttering fully leak proof and with provision for inserts, projecting
dowels, anchor bolts or any other fixture, including staging,
access and working platforms etc all complete as specified and
directed including dismantling and removing the aforesaid
assembly after the concrete attains the sufficient strength to self-
support itself without cracking and distortion, all materials and
labour complete in all respects for the following
Corewalls/Shear Walls
i) Core Walls / Shear Walls Basement - ground floor m2 3,796
Columns
ii) Columns Basement - ground floor m2 1,175
Substructure:
i) Raft Slab m2 568
ii) Retaining Walls m2 3,146
iii) Floor Slab m2 13,628
iv) Floor Beams m2 4,318
v) Ramp Beam m2 866
vi) Ramp Slab m2 784
vii) Staircase m2 214
viii) Water Retaining Structures m2 656
ix) Lintel m2 90
4.1 Providing fabricating and fixing reinforcement for RCC work with
high yield strength ribbed cold twisted tor steel of various
diameters and all lengths, including cutting, bending, fabricating,
welding, wastage and placing in position according to drawings
and binding the reinforcement with the use of 16 gauge
galvanised binding wire of double fold and providing precast
cement cover blocks for main reinforcements to ensure specified
cover according to relevant BS code. The measurements will be
in accordance with BS 5950.
Note : Unless noted otherwise the measurements in accordance
with BS 5950 or equivalent BS. However reinforcement shall be
measured only in lengths of bars as actually placed in position on
standard weight basis, no allowance being made in the weight for
rolling margin. Authorised laps and splices only will be measured.
Chairs of any shape & profile, Spacer bar of any shape & profile,
cover block, wastage and binding wire will not be measured and
shall be included in the quoted rates. Quoted rate shall be
deemed to have considered the above stipulations.
Sqm 88
b) Waterproofing treatment protection shall be in two layers in CM
1:4 of thickness 35mm for floor, 25mm for walls till floor level and
18mm till 300mm above floor level with water proof admixture as
per Manufacturer's specification approved by consultants with a
minimum guarantee period of 10 years.Note: Plan area shall be
the mode of measurement
Sqm 88
Water Tank,Lift pits and Disel storage tank
5.2 a) The method consists of application of first layer of ACRYLIC
MODIFIED / POLYMER MODIFIED CEMENTITIOUS waterproof
coating either single component or two part one after base
preparation of cleaning, brushing and removal of flacky materials,
grouting the porous area with cementations grout,fixing of weep
holes,Grouting of pipe outlets etc and second layer of coating
after fixing theGeo fabric / Fibre glass cloth with proper over
lappings using the same coating when the coating is still green.
The coatings shall be applied at intervals and as per the
manufacturers specifications.
Sqm 1,082
b) Waterproofing treatment protection shall be in two layers in CM
1:4 of thickness 25mm for floor, 18mm for walls with water proof
admixture as per Manufacturer's specification approved by
consultants with a minimum guarantee period of 10 years.Note:
Plan area shall be the mode of measurement
Sqm 4889
c) Providing and laying of 50mm screed concrete of M20 as
protection layer for waterproofing membrane Sqm 4889
5.4 Ground Waterproofing:
Providing waterproofing for Ground Floor Slab by following one or
all methods as per the specifications listed below with a minimum
guarantee period of 10 years and Testing of treatment as per the
requirements. (only plan area shall be accounted)
Sqm 2503
c) Providing and laying of 50mm screed concrete of M20 as
protection layer for waterproofing membrane Sqm 2503
5.5 Retaining Wall:
a) Providing CM as leveling course of 20-25mm thk in two layers
of plaster for receiving APP membrane.
Sqm 8126
b) Supplying, providing and applying water proofing treatment
with Membrane type water proofing methods using polymer
modified Bituminous membrane of approved makes of Atactic
Poly-Propylene (APP-4mm thk) based with UV resistant, ground
chemical resistant, high melting points, flexible and elastic with
high adhesive strength. The membrane shall be reinforced with
non woven polyester reinforcement of minimum of 180 g/sqm and
reinforced including coating with compatible primer of Bituminous
base and torch application with overlap of 100 mm wherever
required. The reinforcement provided shall be able to withstand
the traffic flow density and after construction and shall carry a
minimum guarantee period of 10 years. Cost to include laying by
loose and torching the prefabricated overlap at ends. Approved
makes (Polyplus/Fosroc/IWL/ Texsa or Equilent/Tristar intec)
Sqm 8126
c) Providing and fixing of 6mm thk bituminous board as protection
layer for waterproofing membrane for retaining walls.
Sqm 8126
6.0 Piling Works
DATE
CHECKED
Amount
-
LARSEN & TOUBRO LIMITED
ECC DIVISION - EDRC
1.0 CONCRETE
Corewalls/Shear Walls
i) Core Walls / Shear Walls from Ground Level - 10th Level m3 4,019
ii) Core Walls / Shear Walls from 11th Level - 20th Level m 3
4,342
iii) Local Lift from Ground Level - 6th Level m4 186
Columns
i) Columns from Ground Level - 10th Level m3 1,135
ii) Columns from 11th Level - 20th Level m 3
1,066
1.2 Providing ready mixed concrete to site, taking delivery, laying,
compacting and curing concrete grade M50 as per specifications
using coarse graded aggregate of 20mm and down size
aggregate of approved properties for the following members of all
shapes, at all levels including all lead and lifts, tools & plants,
pumping the concrete to all levels, vibrating, curing etc. complete.
Depending on the size and location, the maximum depth of
concreting will be decided by Engineer in casting at a time.
Corewalls/Shear Walls
i) Core Walls / Shear Walls from 21st Level - 30th Level m3 3,206
ii) Core Walls / Shear Walls from 31st Level - 40th Level m3 2,957
iii) Core Walls / Shear Walls from 41st Level - 50th Level m3 2,491
iv) Core Walls / Shear Walls from 51st & above Levels m3 2,225
Columns
i) Columns from 21st Level - 30th Level m3 1,167
ii) Columns from 31st Level - 40th Level m3 1,368
iii) Columns from 41st Level - 50th Level m3 1,131
iv) Columns from 51st & above Levels m3 464
1.3 Providing ready mixed concrete to site, taking delivery, laying,
compacting and curing concrete grade M60 as per specifications
using coarse graded aggregate of 20mm and down size
aggregate of approved properties for the following members of all
shapes, at all levels including necessary formwork, centering,
shuttering, all lead and lifts, tools & plants, pumping the concrete
to all levels, vibrating, curing etc. complete but excluding cost of
reinforcement. Depending on the size and location, the maximum
depth of concreting will be decided by Engineer in casting at a
time. Rate to include for all necessary formwork
Superstructure
i) Floor Slab from 1st Level - 20th Level m3 9,251
ii) Floor beams from 1st Level - 20th Level m3
2,511
1.4 Providing ready mixed concrete to site, taking delivery, laying,
compacting and curing concrete grade M50 as per specifications
using coarse graded aggregate of 20mm and down size
aggregate of approved properties for the following members of all
shapes, at all levels including necessary formwork, centering,
shuttering, all lead and lifts, tools & plants, pumping the concrete
to all levels, vibrating, curing etc. complete but excluding cost of
reinforcement. Depending on the size and location, the maximum
depth of concreting will be decided by Engineer in casting at a
time. Rate to include for all necessary formwork
Superstructure
i) Floor Slab from 21st - 51st & above Levels m3 14,643
ii) Floor beams from 21st - 51st & above Levels m3 4,172
1.5 Providing ready mixed concrete to site, taking delivery, laying,
compacting and curing concrete grade M40 as per specifications
using coarse graded aggregate of 20mm and down size
aggregate of approved properties for the following members of all
shapes, at all levels including necessary formwork, centering,
shuttering, all lead and lifts, tools & plants, pumping the concrete
to all levels, vibrating, curing etc. complete but excluding cost of
reinforcement. Depending on the size and location, the maximum
depth of concreting will be decided by Engineer in casting at a
time. Rate to include for all necessary formwork
Superstructure
i) Staircase m3 1,024
ii) Ramp Beam m3 172
iii) Ramp Slab m3
315
iv) Water Retaining Structures m3 331
v) Lintel at all heights m3
250
Corewalls/Shear Walls
i) Core Walls / Shear Walls from Ground Level - 10th Level m2 14,023
ii) Core Walls / Shear Walls from 11th Level - 20th Level m2 15,275
iii) Core Walls / Shear Walls from 21st Level - 30th level m2 13,670
iv) Core Walls / Shear Walls from 31st Level - 40th Level m2 13,681
v) Core Walls / Shear Walls from 41st Level - 50th Level m2 11,885
vi) Core Walls / Shear Walls from 51st & above Levels m2 10,247
Columns
i) Columns from Ground Level - 10th Level m2 3,188
ii) Columns from 11th Level - 20th Level m2 2,927
iii) Columns from 21st Level - 30th Level m2 3,789
iv) Columns from 31st Level - 40th Level m2 4,667
v) Columns from 41st Level - 50th Level m2 3,871
vi) Columns from 51st & above Levels m2 1,922
Superstructure
i) Floor Slab m2 126,831
ii) Floor beams m2 19,101
iii) Staircase m2 5,402
iv) Ramp Beam m3 1,100
v) Ramp Slab m3 1,140
vi) Water Retaining Structures m3 2,289
vii) Lintel at all heights m3 3,380
3.1 Providing fabricating and fixing reinforcement for RCC work with
high yield strength ribbed cold twisted tor steel of various
diameters and all lengths, including cutting, bending, fabricating,
welding, wastage and placing in position according to drawings
and binding the reinforcement with the use of 16 gauge
galvanised binding wire of double fold and providing precast
cement cover blocks for main reinforcements to ensure specified
cover according to relevant BS code. The measurements will be
in accordance with BS 5950.
Note : Unless noted otherwise the measurements in accordance
with BS 5950 or equivalent BS. However reinforcement shall be
measured only in lengths of bars as actually placed in position on
standard weight basis, no allowance being made in the weight for
rolling margin. Authorised laps and splices only will be measured.
Chairs of any shape & profile, Spacer bar of any shape & profile,
cover block, wastage and binding wire will not be measured and
shall be included in the quoted rates. Quoted rate shall be
deemed to have considered the above stipulations.
Sqm 14,148
b) Waterproofing treatment protection shall be in two layers in CM
1:4 of thickness 35mm for floor, 25mm for walls till floor level and
18mm till 300mm above floor level with water proof admixture as
per Manufacturer's specification approved by consultants with a
minimum guarantee period of 10 years.Note: Plan area shall be
the mode of measurement
Sqm 14,148
5.2 Terrace Water Proofing
Sqm 555
c) Providing and laying of 50mm screed concrete of M20 finished
smooth to receive waterproofing membrane
Sqm 555
5.3 Water Tank and Swimming Pool
a) The method consists of application of first layer of ACRYLIC
MODIFIED / POLYMER MODIFIED CEMENTITIOUS waterproof
coating either single component or two part one after base
preparation of cleaning, brushing and removal of flacky materials,
grouting the porous area with cementations grout,fixing of weep
holes,Grouting of pipe outlets etc and second layer of coating
after fixing theGeo fabric / Fibre glass cloth with proper over
lappings using the same coating when the coating is still green.
The coatings shall be applied at intervals and as per the
manufacturers specifications.
Sqm 2,101 -
b) Waterproofing treatment protection shall be in two layers in CM
1:4 of thickness 25mm for floor, 18mm for walls with water proof
admixture as per Manufacturer's specification approved by
consultants with a minimum guarantee period of 10 years.Note:
Plan area shall be the mode of measurement