6V 4.5ah (20hr) : Battery Construction
6V 4.5ah (20hr) : Battery Construction
5Ah(20hr)
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is
absorbed by separators and plates and thus immobilized. Should the battery be accidentally
overcharged producing hydrogen and oxygen, special one-way valves allow the gases to
escape thus avoiding excessive pressure build-up. Otherwise, the battery is completely sealed
and is, therefore, maintenance-free, leak proof and usable in any position.
Battery Construction
Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte
Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid
page1 of 2 www.vision-batt.com
CP645 6V4.5Ah
Charged
Current
Voltage
O
Volume
Discharge characteristic (25 C) Constant voltage charging
o
characteristic (0.25CA,25 C)
6.5 (%) (XCA) (V)
140
6.0
120 0.25
5.5 7.5 Charged Volume
Voltage(v)
100 0.20
5.0 7.0 Charge Voltage
80
0.15
4.5 6.5
60
4.0 0.10
40 6.0
0 0.05
20 5.5 Charging Current
0 1 2 3 5 10 20 30 60 2 3 5 10 20 30
min h 0 0
0 2 4 6 8 10 12 14 16 18 20
Discharge time Charging time (hours)
Relationship between
Self-discharge characteristic
charging voltage and temperature
110
100
7.8
90
Capacity(%)
Cycl
Voltage(V)
7.5 e Us
e
80
7.2
70
S ta n d
6.9 by Use
60 o o o
C C C
6.6 50
40
-10 0 10 20 30 40 50 60 0 2 4 6 8 10 12 14 16 18 20
Ambient temperature( oC) Storage time: months
100
100
Capacity(%)
80
Capacity(%)
80
60 60
Testing conditions:floating voltage:2.27 to 2.30V Cell 100% D.O.D. 50% D.O.D. 30% Depth of discharge
ambient temperature: 25 oC(77 oF)
40 40
20 20
100
C
0 .0 5
Life(years)
0 .1 C
Capacity (%)
80
2.30V Cell 0 . 2 C
1 60
1 .0 C
40 2 .0 C
3 .0 C
20
0.1 0
10 20 30 40 50 60
-20 -10 0 10 20 30 40 50( o C)
Temperature( oC)
MH25860 G4M19906-9202-E-16
ISO9001:2008
Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2014-1)
Page 2 of 2