You are on page 1of 8
APATOR METRIX uniSMART Residential and commercial gas meters with mechanical index (UG SERIES) uniSmart uniSMART is the product of Apatar Group dedicated for AMR systems in the gas industry and constitutes aa cheaper alternative to the smart meter. tis designed far customers and users not requiring full functionality of- fered by smart gas meters and also where low gas consumption and lawer frequency of reading requires the use of economic relevant technologies. ‘Atthe same time, it isa product offering broad functionality far reading gas and its balancing in the network, inline with European standards. uniSMART is another proposition of our company to realise the challenge of widespread implementation of smart metering in the EU countries UniSmart is based on the experience of the production of hundreds of thousands of smart meters for the EU mar. kets in recent years, THE BASIC FEATURES 1 Versatility — suitable to be connected to any type of meter equipped with a burglary Apator Metrix S.A. index, produced after 2005, Easy to install and setup — connected a5 a standard impulse transmitter in the meter hanging in the network and configured wirelessly. ® Interoperability — the usage of open communication protocol in accordance with standards EN 13757-3 and EN 13757-4 provides interoperability with devices of other manufacturers and the ability to communicate within a single system ANIR, Reading is carried out by radio. The product is compatible with ather existing technical specifications in the EU countries, such as OMS. 1m Flexibility — can be used in walk-by or stationary systems. We also offer software for these systems operating on readily available equipment (e.g. android based smartphones) Functional Features An open, widely communication protocol used wire- less IM-Bus based on European Standard, EN 13757- Power 1x A. lithium battery ™ Operation time without replacing the battery dl gms 3 and EN13757-4, (above 10 years) = Modes: ™ Parametrisation = TI (transmission frame with readings) ~ initial state = T2 (parameterisation module) ~ service mode Count the number of pulses — 1 pulse means 1 rotation of the last drum With the least significant digit of mechanical index — an algorithm af elimination errars caused for ex- ample by vibration of drum in mechanical index 1m Recalculation of pulses per volume (m") 1m History of flows (60 - daily, 120 - monthly) 1m The alarm log ~ interference by an extemal magnetic field = exceeding the maximum flow (Q,,.) no pulses 1§ Firmware upgrade through RF communication channel 1m Estimated time of battery discharge metering time (date, time) definition of flow precision definition of broadcast schedule the reading frame definition of the contents ofa sent frame § Optional parameters sent in a radio frame volume of the last billing period battery status gas meter type spacing of connector pipes manufacturer year of production ~ installation number Data Encryption AES-128 in accordance with OMS, in accordance with EN 13757-3 — OMS specification with dynamic initialisation vector) MOBILE PHONE APP FOR WIRELESS M-BUS 868 MHZ Inkasent Mobile application, '& compatible with Android versions 6,7 and 8 = currently supports English and Polish languages (other at customer's request) 1S includes a lagin and user management system and a system granting rights to users 1 allows reading the status of UniSmart and HybridSmart gas meters 1 signals the gas meter status/failures mw all data is encrypted - meet the requirements of GOPR. 1 the package also includes desktop applications for = creating application user lists = creating reading lists = encrypting and decrypting user lists and gas meters (csv format) Hel] e i Innovative index with innovative protection against fraud NEW GENERATION SOLUTION FOR SEAL Stampfiominsde INDEX BLOCKADE Appling (een aplina decdes \ x cree aieecentiele from daneerblabe Bre PLACE FOR APPLYING LEAD SEAL (OPTIONAL) BLOCKADE OF COUNTING REVERSE FLOW MECHANICAL TEMPERATURE COMPENSATION Gas meters UG G1.6 up to UG G4 can be equipped with mechanical temperature compensation (bimetal). Em — 0,1Qmaxs Qs Qmax =| cas} a a8 -4--+- 48 2 28 30 ast — E[%] Qmin s Qs 0,1Qmax 13] as SS ae Tr] aa as ma) Gas is a substance subject to thermal expansion, which means that depending on temperature, it increases or decreases its volume. Consequently, what changes is the measuring accuracy of a gas meter with relation to its energy content. In other words when gas with some energy cantent, volume and temperature is already in pipes and is heated, then the index unit is to show a bigger consumption after flow, whereas when gas is cooled, the gas meter will indicate a lower consumption. It is a very important issue as a temperature change of 3°C corresponds to a volume change of approximately 1%. Such considerable temperature changes are likely to occur especially to meters placed on the autside of a building. Consequently the meter works at various temperatures depending on the season. A gas meter with temperature compensation provides a solution to this problem as it uses and undergoes thermal expansion as well. A temperature compensation mechanism installed in the measuring unit is adjusted in such a way so that it changes the cyclic volume of the measuring mechanism exactly like gas undergoing expansion due to temperature changes. Elements responsible for compensation installed in the meter allow a radial shift of the diaphragm, which results inmoving the curve of typical error up or dawn in relation to the zera line. Thus the gas meter converts the measured value of gas volume into its value at fiducial temperature — irrespective ‘of measuring temperature. ————————— i 3 UG G4 MULTI RANGE (UG G1.6, UG G2.5, UG G4)- 3 in1 TECHNICAL DATA ‘Maxim flaw [Minimum flow ate Nominal flaw rate UG 12 dim? series gas meters are designed for measurement of gas sup- plied to apartments where consumption of gas does nat exceed 6 m:/h of air density of 1.2 kg/m? THE GAS METERS CAN BE USED FOR MEASUREMENT OF: 1m Natural gas m City gas 1m Propane-butane gas Gas meteris equipped with pulse magnet as standard. Pulse transmit- tercan be added at any time (1 imp = 0.07 m) us6a mn 5 mm [ois 70025 70.040 a yale volume 1 Max working pressure bar 05 Tndex man ineeation mh ‘gogu9 950 Scaring flow rte fo 5 Freproc ip to S086 seeordingto EN 1358 bar a Case material ‘ADDITIONAL INFORMATION ON Cycle volume ‘Allowable indication exor ints during intial werfication - Qin 901 Qmax -Dimaxto Qmax Temperature UGT-Teconection ange standard optional DIMENSIONS d lezetey Steet GAS METERS (WITH MECHANICAL TEMPERATURE COMPENSATION usT 1s de 35% 220% 25 +55" an+arc 25540" stem Aime tom ine to ee a CURVES OF TYPICAL ERROR AND PRESSURE LOSS cod © 24 ‘ann | “oom 2ension 4 2UG GB UG 2.2 dm? series gas meters are designed for measurement of gas supplied to apartments where cansumptian of gas does nat exceed 1Om*s/h ofair density of 1.2 kg/m. THE GAS METERS CAN BE LISED FOR MEASUREMENT OF: = Natural gas m City gas = Propane-butane gas Gas meter is equipped with pulse magnet as standard, Pulse transmitter can be added at any time (1 imp = 0.01 m). TECHNICAL DATA 2uces Maximum flow rate mh 10 imum ow ae mim Tost Nominal fos ae mh Bi Cycle vokime om Fa Ppeteeire pre 5 05 Index maxindeavon mh 35509599, Starting Now ate any 5 Freproof unto 650 CaccodngioENISSD | bar a ADDITIONAL INFORMATION ON GAS METERS WITH MECHANICAL TEMPERATURE COMPENSATION uct “Geievoume SNS “Allowabieincicaton ears imitsduringintilveifeation: fT -Qminta 03 gmax 235% -O1maxta mae 220% a [ust-tcemenionansel po -standard 040% optional 25-40 DIMENSIONS Ae Dp Tas Qo ni ey oe ae ‘a CURVES OF TYPICAL ERROR AND PRESSURE LOSS: aT a a [Zing risk a UG G10 & UG G16 = UG 5.Gdm* series gas metersare designed for measurement of gas supplied to commercial consumers where maximum consump- tion of gas does not exceed 25 m?/h of air density of 1.2 kg/m’. THE GAS METERS CAN BE USED FOR MEASUREMENT OF: ] 1 Notural gas m= Giygas } ™ Propane-butane gas Gas meter is equipped with pulse magnet as standard. Pulse 7 transmitter can be added at any time (Timp = 1m’) TECHNICAL DATA usG10 uss Maximum flow rate [mn 6 | 25 ‘Minimum fiw rate imi/h a 16 ‘Nominal flow ate im/h 10 76 Cycle volume i’ 56 56 ‘Max working pressure [tar 05 05 ~ Index max indication mh 9999999.99 989999.99 Starting flow race ama a 3 Freproof up to 650°C according ta ENTS bar on ar DIMENSIONS, ——— _ Atom | Elm fmm] ( } [¥ 7524 393 359 2a a all 20) 39s [s8s/ses*[ aia | 91 | 7a 280) 393 345 214 al 68 300) 303 345 2a a1 68 "8576 connections L 8 J CURVES OF TYPICAL ERROR AND PRESSURE LOSS, UG Gia UGGIB ED 3 EC) a t a 7 ae ‘alee % 20 "a0 | FREE : | %9 + L a ton es ove re Qn fae UG G25 UG 11.2 dim? gas meter is designed for measurement of gas sup- plied to commercial consumers where maximum consumption of {gas does not exceed 40 m3/h of air density of 1.2 kg/m? ‘THE GAS METERS CAN BE SED FOR MEASUREMENT OF: = Natural gas m City gas, 1m Propane-butane gas Gas meter is equipped with pulse magnet as standard. Pulse transmitter can be added at any time (1 imp = 0.1m’). TECHNICAL DATA uGG2s ‘Maximum flow rate mz/h 40 ‘Minimum flow rate mf 025 ‘Nominal flow rate mz/h 25 ‘Cyclic volume dm? n2 ‘Max working pressure bar os Index max indication mh 99999993 Starting flow rate dmv'/h 20 Fireproof up to 650 °C according to EN 1359 bar 01 DIMENSIONS, pa tei D eee ee Cy Almm)] | Blmm] | Cmm) | Ofmm] | Elm) | Weight (ks) d 280, 456 380 a3 141 120k 335, 456, 361 a3 41 Ti5kg aga 476 460 a3 1a 14.8 L B CURVES OF TYPICAL ERROR AND PRESSURE LOSS: UG G25 Ep 40 eae ae ‘ator nears Komplek Glodok Jaya, Ruko No. 90. Hayam Wuruk, Jakarta 11180 - Indonesia 188 +62.21.649 8752, 649 8755, 649 8760, 600 9805, 600 9806, 600 7975 @+62.21.626 3731 1m sales @badjaabadisentosa.com BAS Olean ——— 7

You might also like