Professional Documents
Culture Documents
CATALOG/TECHNICAL MANUAL
CODE LIST
for Dentists and Dental Technicians
th
9 Edition
T h e d e n t a l A t t a c h m e n t s c o m p a n y
1
OT EQUATOR system is a global, well-established rea-
lity in the removable prosthetic protocols. Today our
research allows its use in a fixed denture treatment.
This is possible thanks to the Seeger system, a novelty
and a revolution in the “fixed implant prosthetics” that
allows to reduce the number of the prosthetic screw
holes in the aesthetic areas. The sub-equatorial com-
ponent, an interchangeable acetal ring, will be housed
into the cylindrical “Extragrade” abutment; this acetal
seeger spring, is one of the original elements of this
product and represents a systematic alternative to the
screwed and cemented dentures.
STANDARD MINI
EXTRAGRADE ABUTMENT EXTRAGRADE ABUTMENT
Ø 3,3mm
Ø 2,5mm
Ø 3,0mm
Ø 2,2mm
h 9,5mm
h 5,7mm
Ø 3,5 mm
Ø 3,5 - Ø 4 - Ø 5 mm Ø 3,5 - Ø 4mm
Ø 2,4mm
Ø 2,4mm Ø 2,1mm
h 4,4 mm
h 4,4 mm
h 4,9mm
Ø 4 mm
SOLUTION A SOLUTION B
Model scan with the titanium through hole abut- Scan of the model with the scan abutments for the Digital structure CAD designed, ready to be realized.
ments for a CAD design. digital flow. The top beveled surface matches with The Extragrade titanium abutments will be cement-
the Extragrade incision of the titanium abutment; ed into the holes.
the Extragrade must always be positioned in cor-
respondence of the maximum undercut created by
the tilted implant.
Model analysis with the Implants divergency analysis. Analysis of the teeth set-up dimensions. The project is made
Rhein83 parallelometer. with the titanium abutments with screws, sleeves to be bond-
ed and titanium abutments inclined at 15° without screws.
Long screw on Ot Equator Extragrade Titanium Abutment inclined In case of an excessive implant inclina- It is important to position the flat surface of the ti-
analog to check where the at 15°. The white Seeger must be posi- tion, it is suggested to use an Extragrade tanium abutment in correspondence with the un-
prosthetic screw hole will tioned with its open side towards the titanium abutment inclined at 15° with- dercut created by the inclination of the implant; the
be located. Extragrade bevel. out screw and a castable sleeve to be flat surface indicates the location of the Extragrade
bonded. The abutment will be retained bevel, which will allow the denture to overcome the
by the white Seeger only. The percent- undercuts created by the tilted implant.
age of abutments without screws should
be limited to 25% of the total number of
abutments (in this case 1 out of 4).
The open side of the Seeger The castable sleeve allows the con- The castable structure must be as passive as pos- The castable structure ready to be cast.
must be positioned towards struction of a structure that later will sible. Passivity is facilitated by the use of castable
the Extragrade, a position be cast. Then the Extragrade titanium gingival connectors that can be adapted, cut and
that is forced by an anti-rota- abutments will be passively bonded. shaped, trying to leave as little space as possible be-
tional device located into the tween these and the implant abutment.
abutment.
Before bonding, the fitting of the Place the Extragrade titani- The cement should be Alternatively: screw the tita- Work polished, assembled, ready to
framework should be tested. it um abutment with the short put on the external part nium abutment and smear the be coated with the aesthetic material.
is important to cement the ele- screw onto the Ot Equator of the Extragrade tita- screw with vaseline, keeping Please note the white Seegers inserted
ments one at a time. The use of the attachment, making sure nium abutment and into the Extragrade abutment in the in the Extragrade abutment housing.
Ot Cem composite cement from to place the flat surface of the internal surface of exact position; respect the set-
Rhein83 is recommended. the titanium abutment in the metal cast sleeve. The ting time of the composite ce-
correspondence with the wax pin will seal and pro- ment as reported in the instruc-
undercut created by the tect the entrance of the tions for use.
implant inclination. It is rec- prosthetic screw.
ommended to protect the
screw hole with a wax pin.
castable abutments
Model analysis with the help of the diagnostic teeth Into the castable The Extragrade position is indicated by Cast and sand-blasted bar with 150 micron par-
set-up mask. Where the space is limited, the Extra- abutment with the flat surface outside the abutment; ticle size aluminum dioxide at 3 atmospheres.
grade castable abutment is advisable which, while screw, likewise the this must always be positioned in corre-
allowing a passive insertion, overcomes the diver- titanium abutment spondence with the undercut created by
gencies and can be shaped accordingly to the avail- with screw, you can the tilted implant.
able spaces. see the bevel called
Extragrade.
Detail of the castable Special bur to clean any oxides, micro-imperfections Test with the OT Equator Framework polished and ready to be finished with the aes-
abutment after the cast- or bubbles inside the Seeger housing in those areas analog, before proceed- thetic covering.
ing and the sandblasting. where the sandblasting is not effective. ing with the trimming
and the polishing of the
framework.
Insert the Seeger as shown in Work finished; caudal view. Vestibular view. Please note that thanks Denture completed.
the photo by placing the open to the pre-angled abutments and the
section in correspondence Seeger there are no vestibular prosthet-
with the undercut created by ic screw holes.
the inclination of the implant.
Ideal solution for cases with immediate loading or for all cases where a temporary device is required to
provide an excellent structural strength.
1,8 mm
3 mm
Titanium wire for the construction of wire reinforced Titanium wire inserted into the Insert the titanium wire into all lateral holes of the the titanium
frameworks. lateral hole (ø 1mm ) of the abut- abutments.
ment.
Screw the titanium abutments with lateral holes one The teeth are positioned and shaped accordingly to The titanium abutments with lateral holes can be
at a time and bend the titanium wire accordingly so to the mask and the available spaces. adapted accordingly to the available spaces and
follow the correct gingival and prosthetic profile. being properly opacified and then embodied with
self-curing aesthetic resin.
The titanium abutments with lateral holes do not have It is fundamental to position the Seegers so that Insertion of the Seegers into all the titanium
the Extragrade bevel, so if necessary it can be made their open side is in correspondence with the abutments.
manually, once the work is finished, paying the utmost undercut created by the tilted implant.
attention in doing it always on the divergent side.
Even with the temporary dentures, the insertion pat- In case of strong disparallelisms (like an all-on- The resin-wire-reinforced bridge is finished and deli-
terns must be followed accordingly to the implant four) it is advisable to insert the bridge first on the vered to the dentist in about 2 hours.
divergences both on the model and into the patient’s most inclined attachments, which in this case are
mouth. those located on the incisor area, then moving to
the posterior area, making the denture snap into
the correct position.
healing abutments
OT EQUATOR SEEGER
IMPRESSION COPINGS
TITANIUM LONG IMPRESSION COPING WITH TITANIUM IMPRESSION COPING WITH PLASTIC IMPRESSION PLASTIC MINI IMPRESSION
LONG SCREW FOR PICK-UP IMPRESSION SCREW FOR PICK-UP IMPRESSION COPING COPING
Option 1: Healing screw screwed onto the Option 2: Ot Equator Seeger screwed onto Example of the two options screwed onto the Ot Equator abutment.
Ot Equator abutment. the Ot Equator abutment.
OT EQUATOR SEEGER
Insertion of the Ot Equator seeger inside the self- Like the titanium seeger screw, the Ot Equator seeger 2 threaded Ot Equator for cam and 2 Ot Equator see-
extracting peek ring already in position. also removes the self-extracting peek ring during ger in position, in case of divergence (the Ot Equator
unscrewing. seegers follow the direction of the implants) the use
of Smart box housings is recommended.
Elastomer impression with Ot Equator analogs Often the plastic impression copings remain in the
matching the diameter of the inserted implants. mouth; remove and reposition them into the impres-
sion; the right position can be easily found before
pouring the model.
IMPRESSION COPINGS
Impression with the titamium impression co- Impression with the plastic impression co- Impression with the plastic mini impression
pings with screws. pings. copings, ideal solution when there is not
enough vertical dimension.
In case of an immediate loading denture, the im- Upper model cast in quick-setting plaster and sili- Lower model cast in quick-setting plaster.
pression can be taken with the mini impression cone mask.
copings and collecting all the necessary data just
after the surgery.
Telescopic bar designed for screwed structures without stress on implants for immediate loading
dentures using the bonding technique without casting and welding; available with retentive cylin-
ders (optional) for a better tooth retention. the system can also be used for screwed bridges. Avai-
lable in medical grade stainless steel and in grade 5ELI Titanium. The Titanium version joints can be
welded to the Extragrade abutments.
Ø internal Ø internal
Ø external Ø internal
Ø external Ø external
Ø internal Ø external
3,70 mm 3,705,20
mmmm 4,30 mm5,20 mm 4,30 mm5,90 mm 5,90 mm height
7,50 mm
Ø external ØØinternal
external Ø internal
3,00 mm 2,00
3,00mmmm 2,00 mm
CYLINDER
Extragrade system
The anti-rotationality of the seeger ring is possible The OT Bridge prosthetic abutment must be positioned with its
thanks to the stop inside the prosthetic abutment extragrade flaring in correspondance of the implant undercut.
which prevents any seeger rotation
The Set 42 is produced and shipped within 5 days from the order, it is mandatory to indicate:
implant brand, implant diameter and cuff height.
Available heights:
for internal hexagon implants from 0.5 to 7mm
for external hexagon implants from 2 to 7mm
OT EQUATOR ABUTMENT
set 42
• 1 ASSORTMENT SET (autoclavable) + 42 OT EQUATOR +TiN ABUTMENTS
Ref. BE42 THE SET42 CAN BE CUSTOMIZED ON THE BASIS OF THE IMPLANTS BRANDS, IMPLANTS
+ n° 42 Ot Equator DIAMETERS AND CUFF HEIGHTS DESIRED. PLEASE INDICATE, IN THE ORDER, THE QUANTITY
(Ref. 030 to be chosen) AND THE ABOVE SPECIFICATIONS FOR EVERY KIND OF ABUTMENT.
(Tools not included in the set)
IMPRESSION COPINGS
HEALING ABUTMENTS
SCREW AND HEALING RING
Ref. 159VAG SET CONTENT
• 1 HEALING TITANIUM SCREW
• 1 TITANIUM SELF-EXTRACTING HEALING RING
LABORATORY ANALOGS
Ref. 144AE • 2 LABORATORY ANALOGS ø 4mm
SCREWS
Ref. 147VME • 1 TITANIUM SCREW FOR EXTRAGRADE ABUTMENT
(for screwdriver/stem for inclined Channel)
TOOLS
Ref. 774CHE
• 1 SQUARE SCREW DRIVER + OT EQUATOR HOLDER
Ref. 775CLE* (square tip 1.25mm) (USABLE WITH THE MANUAL TORQUE WRENCH)
(*long version)
Ref. 760CSC
• 1 SCREWDRIVER/STEM FOR ANGULATED CHANNEL
Ref. 760CS* for torque controller contra angle (square 1.25mm)
(*long version)
TITANIUM T-BAR
Ref. G80T • 4 TITANIUM JOINTS
TOOLS T-BAR
SPARE PARTS
Ref. RMTSFEG • 1 EXTRAGRADE TITANIUM ABUTMENT INCLINED AT 15° Ø 3,5mm
Ref. GCMR • 1 CASTABLE SLEEVE FOR INCLINED TITANIUM ABUTMENT WITHOUT HOLE Ø 3,5mm
Ref. GCMR4 • 1 CASTABLE SLEEVE FOR INCLINED TITANIUM ABUTMENT WITHOUT HOLE Ø 4,0mm
Ref. MTFP • 1 TITANIUM ABUTMENT WITH LATERAL HOLES FOR TEMPORARY RESIN BRIDGE
WITH WIRE-REINFORCMENT h1,8mm (ONLY AVAILABLE WITH Ø 3,5mm)
Ref. MTB30FP • 1 TITANIUM ABUTMENT WITH LATERAL HOLES FOR TEMPORARY RESIN BRIDGE
WITH WIRE-REINFORCMENT h3mm (ONLY AVAILABLE WITH Ø 3,5mm)
Ref. RMCEG15SF • 1 EXTRAGRADE CASTABLE ABUTMENT WITHOUT HOLE (ONLY AVAILABLE WITH Ø 4,0mm)