CP-2000 Bedienungsanleitung Techniker 1.4(英文)
CP-2000 Bedienungsanleitung Techniker 1.4(英文)
V1. 4
2008-12-12
Operation Instructions of Controller for Screw Air Compressor
Content
1. Operating Panel .............................................................................................................................. 3
2. About Keys ...................................................................................................................................... 3
3. Characteristic of Input and Output of External Switching Quantity and Analogue Quantity ........ 4
4. Description of Operation of Air Compressor .................................................................................. 5
4.1 Starting and Home page ...................................................................................................... 5
4.2 Main Menu of Air Compressor ............................................................................................ 6
4.2.1 Page of Look ...................................................................................................................... 6
4.2.2 Page of System parameter ................................................................................................ 8
4.2.3 Page of maintenance ......................................................................................................... 9
4.2.4 Page of failure record ...................................................................................................... 10
4.3 Page of User Parameter Set ................................................................................................... 10
4.4 Page of manufacture Parameter Set ...................................................................................... 13
5. Operation, Alarm and Fault Status of Air Compressor ................................................................. 13
5.1 Operation Status .................................................................................................................... 13
5.2 Slight Fault Alarm ................................................................................................................... 14
5.3 Serious Fault Shutdown ....................................................................................................... 14
Appendix........................................................................................................................................... 15
1. User Parameter ........................................................................................................................ 15
2. Manufacture Parameters ......................................................................................................... 16
3. Hardware Parameter ................................................................................................................ 17
4. Internal Parameters .................................................................................................................. 17
5. Alarm and Fault ........................................................................................................................ 17
-2-
Operation Instructions of Controller for Screw Air Compressor
1. Operating Panel
LCD DISPLAY
START
STOP
2. About Keys
START — Start and run air compressor under the condition of free fault, and change the
mode from shut-down to running.
SET — After the parameters modified, press this key to confirm the input data.
UP — When the data being modified, press this key to increase the digital bit. This
key is used as a selection key for menu selection.
DOWN — When the data being modified, press this key to decrease the digital bit. This
key is used as a selection key for menu selection.
SHIFT/ENTER — This key is used as a shift key for the data being modified and an enter
key for the menu being selected.
RETURN — For menu operation this key is used to return the upper menu.
-3-
Operation Instructions of Controller for Screw Air Compressor
1 1
JP4 JP1
1 1
JP5 JP3
7 A RS485 communication
8 B RS485 communication
After the controller is energized, the power indicator on the operating panel shines and
then the screen displays a starting page.
PRES:0.00MPa Remo
Temp:000℃ Stop
On the above-seen screen, there are two options. The first indicates the exhaust
pressure value; the second indicates the exhaust temperature value.
Run status including: emergent stop, compressor stop, compressor start, compressor
on-load, compressor offload and compressor no-load.
-5-
Operation Instructions of Controller for Screw Air Compressor
Alarm status including: Service life of air filter, service life of oil filter, service life
of oil-air separator and service life of lubricating oil, air filter clogging, oil filter clogging,
oil-air separator clogging, exhaust high temperature alarm, high ambient temperature, low
ambient temperature, and over-current of motor.
Fault status including: broken line of pressure sensor and temperature sensor;
shutdown of high exhaust temperature, high oil barrel temperature, water-loss, high
pressure, high oil barrel pressure; wrong phase sequence, over voltage, low voltage and
abnormal current.
If a fault exists in the compressor, the display indicates the fault. If faults exist, the
display indicates the earliest one. Upon removal of the fault (s) STOP key is pressed to
return to the indication.
If an alarm signal is given, the display alternately indicates the alarm status and
running status. If alarm signals are given, the display indicates them one by one in priority.
On the default page DOWN key is pressed to enter the main menu of air compressor.
Look ◆ Care
Sys Err
On the above-seen screen, the first line indicates Look and Care options; the second
line indicates System and Error options. The right symbol “◆” indicates a current menu.
On the main menu of air compressor when the symbol “◆” is moved to the right of
Look option, the SHIFT/ENTER key is pressed to enter a page of Look option of the air
compressor
Moto ◆ Fan
Time IO
On the above-seen screen there are four options. The first indicates Main and Fan
motor of compressor; the second indicates Time and IO. The symbol “◆” is moved to the
screen indicates a current menu. Press the RETURN key and return to the upper menu
(page of main menu of compressor).
1. Page of compressor main motor: when the symbol “◆” is moved to “Moto”, press the
SHIFT/ENTER key to enter a page of Main motor.
-6-
Operation Instructions of Controller for Screw Air Compressor
A :000A B: 000A
C:000A V:000A
On the above-seen screen the first line indicates main motor phase A and B current
value; the second line indicates main motor phase C current and power voltage value. Press
the RETURN key and return to the upper menu (page of Look).
2. Page of time: when the symbol “◆” is moved to the “Time”, press the SHIFT/ENTER
key to enter a page of time.
On the above-seen screen there two options. The first indicates run time of compressor;
the second indicates load time of compressor. Press the RETURN key to return to the
upper menu (page of Look).
3. Page of Fan motor: when the symbol “◆” is moved to the “Fan”, press the
SHIFT/ENTER key to enter a page of fan motor.
A :00.0A B: 00.0A
C:00.0A
On the above-seen screen the first line indicates exhaust pressure. According to
different types of the device sometimes the screen indicates the pressure value of oil barrel
and the pressure difference of oil-air separator. Press the RETURN key to return to the
upper menu (page of Look).
4. Page of IO: when the symbol “◆” is moved to the “IO”, press the SHIFT/ENTER key
to enter a page of input and output number.
In :00000000
Out :00000000
On the above-seen screen there are two options. The first indicates input number, the
second indicates output number. Press the RETURN key to return to the upper menu (page
of Look).
-7-
Operation Instructions of Controller for Screw Air Compressor
When the symbol “◆” is moved to selection of “Sys”, press the SHIFT/ENTER key to
enter a page of system parameter.
Low Temp:-00 ℃ ↑
Unload P:0.00MPa ↓
Load P:0.00Mpa ↑
Fan Start :000℃ ↓
Baudrate:09600Bps ↑
Unit No.:01 ↓
CommMode:SLAV ↑
NetworkStart:030S ↓
NetworkUload:030S ↑
Network Turn: 100H ↓
On the above seen the screen there are fourteen options. The first indicates start up
time, the second indicates high exhaust alarm temperature, the third indicates low exhaust
alarm temperature, the fourth indicates unload pressure, the fifth indicate load pressure, the
sixth indicates fan start temperature, the seventh indicates fan stop temperature the eighth
indicates auto stop time, ninth indicates baud rate of communication, the tenth indicates the
number of compressor in combined mode, the 11th indicates the mode in combined way,
-8-
Operation Instructions of Controller for Screw Air Compressor
the 12th indicates network start time, the13th indicates network unload time, the 14th
indicates network turns time . Press the RETURN key to return to the upper menu
(System).
On the main menu of air compressor when the symbol “¡” is moved to the “Care”,
press the SHIFT/OK key to enter the page of compressor maintenance.
Air Use:00000H
Air Res:00500H
OilF Use:00000H
OilF Res:02000H
SeparUse:00000H
SeparRes:00500H
Lube Used:00000H
Lube Rema:5000H
GreaseUsed: 0000H
GreaseRema:5000H
On the above seen the screen there are ten options. The first indicates Air filter used
time, the second indicates Air filter remain time, the third indicates Oil filter used time, the
fourth indicates Oil filter remain time, the fifth indicate Oil-air separator used time, the
sixth indicates Oil-air separator remain time, the seventh indicates Lube used time, the
eighth indicates Lube remain time, ninth indicates Grease used time, the tenth indicates
Grease remain time. Press the RETURN key to return to the upper menu (page of main
menu of air compressor).
-9-
Operation Instructions of Controller for Screw Air Compressor
On the page of main menu of air compressor when the symbol “¡” is moved to “Err”,
press the SHIFT/OK key to enter the page of failure record.
Err 0:None
Time0:00000Hr ↓
Err 1:None ↑
Time1:00000Hr ↓
On the above seen the screen there are ten pages, It record the lately failure, ten record
in all (0 to 9), the first line indicates the name of failure, the second indicates the time of
failure.
On the page of default menu of air compressor, presses the SET key enter to the page
of password.
Input Password
0000
The flashing bit is current input bit. Press the UP key to increase one input bit and the
DOWN key to decrease one input bit. Move the flashing bit by pressing the SHIFT/OK key.
After the input is finished, press the SET key. Input user passwords “1111”and press SET
key to enter the page of user parameter set.
Oper ◆ Care
Time
1. Page of operate: when the symbol “¡” is moved to the “Oper”, press the
SHIFT/ENTER key to enter a page of operate.
- 10 -
Operation Instructions of Controller for Screw Air Compressor
Unload P :0.00MPa ◆
Load P :0.00Mpa ↓
FanStart:000℃ ◆↑
Fan Stop:000℃ ↓
CommMode:SLAVE ◆↑
Unit No. :01 ↓
Language :ENG ◆↑
Password :1111 ↓
ContrMod:AUTO ◆↑
When the symbol “◆” is moved to the parameter, press the SHIFT/OK key ,the
symbol “◆” “↑”and “↓” disappeared, press UP key to increase one input bit and the
DOWN key to decrease one input bit. Move the flashing bit by pressing the SHIFT/OK key.
After the input is finished, press the SET key to save the changed parameter. Press the
RETURN key return to the upper menu (page of default).
2. Page of Time: when the symbol “◆” is moved to the “Time”, press the SHIFT/ENTER
key to enter a page of time parameter set.
Start UP :15S ◆
LoadDelay:10S ↓
- 11 -
Operation Instructions of Controller for Screw Air Compressor
AutoStop:15Min ◆↑
StopTime:15S ↓
NetworkStart :030S ◆↑
NetworkUload :030S ↓
When the symbol “◆” is moved to the parameter, press the SHIFT/OK key ,the
symbol “◆” “↑”and “↓” disappeared, press UP key to increase one input bit and the
DOWN key to decrease one input bit. Move the flashing bit by pressing the SHIFT/OK key.
After the input is finished, press the SET key to save the changed parameter. Press the
RETURN key return to the upper menu (page of default).
3. Page of Time: when the symbol “◆” is moved to the “Care”, press the SHIFT/ENTER
key to enter a page of maintaining setting.
AirFLife:0500Hr ◆
OilFLife:0500Hr ↓
GreaseLife :500Hr ◆↑
AirF Use:0000Hr ↓
- 12 -
Operation Instructions of Controller for Screw Air Compressor
When the symbol “◆” is moved to the parameter, press the SHIFT/OK key ,the
symbol “◆” “↑”and “↓” disappeared, press UP key to increase one input bit and the
DOWN key to decrease one input bit. Move the flashing bit by pressing the SHIFT/OK key.
After the input is finished, press the SET key to save the changed parameter. Press the
RETURN key return to the upper menu (page of default).
On the page of password input, input the manufacture passwords and enter to the
manufacture parameter setting page. As user can not change the manufacture parameter
setting, we don’t introduce anymore.
- 13 -
Operation Instructions of Controller for Screw Air Compressor
On the PLC of the controller the status bar displays alternatively the corresponding
slight fault alarm message. For the slight fault the air compressor does not stop within a
certain time, only indicating that the compressor needs to be maintained.
If the compressor is out of serious order, it will stop automatically and not restart until
the fault is removed. On the PLC of the controller the status bar displays the serious fault
alarm message happening at present.
- 14 -
Operation Instructions of Controller for Screw Air Compressor
Appendix
1. User Parameter
When modifying the user parameters, the user need to input the user password. The
default password is 1111.
- 15 -
Operation Instructions of Controller for Screw Air Compressor
2. Manufacture Parameters
When modifying the workshop parameters, the user can only use the workshop password
(****).
3. Hardware Parameter
Note: Those parameters have set before delivery and do not modify unless necessary.
Otherwise an unexpected result will happen.
4. Internal Parameters
Note: Parameter with its quantity may vary with models and are based on workshop data.
We hold the right to add the functions and select the parts without further notice. The
password **** is available for access to the user parameters.
State of air
Fault Status Indicator
compressor
Clogging of air filter Clogging of air filter Alarm indicator shining Alarm, not stop
Reach air filter service
Air filter service life Alarm indicator shining Alarm, not stop
life
Clogging of oil filter Clogging of oil filter Alarm indicator shining Alarm, not stop
Reach oil filter service
Oil filter service life Alarm indicator shining Alarm, not stop
life
Clogging of oil-air Clogging of oil-air
Alarm indicator shining Alarm, not stop
separator separator
Reach oil-air separator Oil-air separator
Alarm indicator shining Alarm, not stop
service life service life
Reach greaser service
Oil injection to bearing Alarm, not stop
life
Low ambient Too low ambient
Alarm, not stop
temperature temperature
- 17 -
Operation Instructions of Controller for Screw Air Compressor
- 18 -