You are on page 1of 8

FLUID - Panic Exit Device

Contents
1 • 1 point: Rim
2 • 2 point: Vertical
3 • 2 point: Horizontal
4 • 2 point: Rim and vertical
5 • 3 point: Rim and vertical
6 • 3 point: Rim and horizontal
7 • 3 point: Rim, vertical top and horizontal bottom.

1 2 3 4 5 6 7

Rep Quantity
A 2 pivot axis
Abis 2 anti-noise axis

B 1 1 2 2 2 3 3
1 mm

C 1 1 2 2 2 3 3
2 mm

D 1 1 2 2 2 3 3
3 mm
E 1 1 2 2 2 3 3
F 1 1 2 2 2 3 3
G - 1 - - 1 - -
H - 2 2 1 2 2 2

I 8 16 16 12 16 16 16
Ø 4,8 x 25

J 5 9 9 7 9 9 9
M 4 x 10

Ø 4,8 x 38 K 3 5 6 6 8 9 9

L - 4 4 2 4 4 4
Ø 3,5 x 19

1
FLUID - Panic Exit Device
Installation for standard doors and rebated doors

Templates to be aligned with the frame

+2 mm
-4 mm

Edge of frame
G1
+3 mm
+8 mm

Add 1 set of plates

Edge of frame
+14 mm
+8 mm

G5
+13 mm
+19 mm
+14 mm
+8 mm

G4
+13 mm
+19 mm

Floor

Templates to be placed 10 mm from the frame


+19 mm
mini

10 mm
Edge of frame
10 mm 10 mm

10 mm 10 mm
(edge
Edge of
G5
G4

of frame)
frame
G1

2 Floor
FLUID - Panic Exit Device
Installation instructions
Mandatory radius
No seal for contact
IMPORTANT ! between bolt and frame

1 Template layout and strike installation


Use the templates included in the box 1 mm

0
E
K
F

Edge of frame

30 mm
min
0
E

K
F
1 mm

1 050 mm

Floor

K
G

1 mm
3
FLUID - Panic Exit Device
1 Point Rim
52 mm

2 9 L = see step 6-8

L - 50 mm
80 mm
==

J
10
J
3 Abis
Abis
A
I
A

• F or 2 - 3 point Vertical versions, go directly 11


to step 15 J
• F or 2 - 3 point Horizontal versions, go directly
to step 30
4

12

30 mm

5 I 7
13
30 mm
==

! Axial gap
= 1 mm J
L

6 8 14 I

4
FLUID - Panic Exit Device
2 - 3 Point Vertical

15 16 23 24 25 29
85 mm

==
22 mm I

Cutting area
to be
cleared

17 18
Spring
I ! Free
position to L H rotation
be checked Screwing
! torque
< 2 Nm

J
19 20 26 27 28
22 mm
==

Spring
109 mm

position to
I ! be checked Free
L H rotation
Screwing
! torque
< 2 Nm
21 22 Cutting area
to be
cleared

Go on step 11

5
FLUID - Panic Exit Device
2 - 3 Point Horizontal

30 31 36 37 39 40
52 mm

I I
J
80 mm
==

N + 50 mm

Top H
32
N

Free
L rotation

Cutting area
! Screwing
torque
to be
cleared < 2 Nm

38

33 34
52 mm

H
M + 50 mm

I
80 mm

Cutting area
to be L
==

cleared Free
Screwing
! torque
rotation
M

< 2 Nm

I
35

Go on step 11
Bottom

6
FLUID - Panic Exit Device
Screwing

M
Rod Cover 1 3
2 4 !

N
torque
< 2 Nm

M - 45 mm
x2

x1

x4

Installation and fixing instructions


The following shall be the minimum information and installation guidance to accompany the panic exit 14. The bolt heads and keepers should be fitted to provide secure engagement. Care should be taken
device:- to ensure that no projection of the bolt heads, when in the withdrawn position, can prevent the door
1. The producer shall specify the appropriate fixing arrangements for the door types for which the exit swinging freely.
device is designed. 15. Where panic exit devices are to be fitted to double doorsets with rebated meeting stiles and self-closing
2. Before fitting an exit device to a door, the door should be checked to ensure correct hanging and freedom devices, a door coordinator device in accordance with EN 1158 (see Bibliography) should be fitted to
from binding. It is not recommended, for example, that exit devices befitted to hollow core doors unless ensure the correct closing sequence of the doors. This recommendation is particularly important with
specially designed by the producer for this type of doors. It is recommended to verify that the door regard to fire/smoke resisting door assemblies.
construc¬tion allows the use of the device, i.e. to verify that offset hinges and engaging leaves allow both 16. No devices for securing the door in the closed position should be fitted other than that specified in this
leaves to be opened simultaneously (see A.4), or to verify that the gap between door leaves does not differ European Standard. This does not preclude the installation of self-closing devices.
from that defined by the exit device producer, or to verify that the operating elements do not interfere, 17. If a door closing device is to be used to return the door to the closed position, care should be taken not to
etc. NOTE: Panic exit devices manufactured in accordance with this European Standard will provide a high impair the use of the doorway by the young, elderly and infirm.
degree of safety and reasonable security provided that they are fitted to doors and door frames that are in
good condition. 18. Any keepers or protection plates provided should be fitted in order to ensure compliance with this
European Standard.
3. Before fitting a panic exit device to a fire/smoke resisting door, the fire certification should be examined
to ensure the suitability of the panic exit device for that particular door assembly. See Annex B. 19. A sign which reads “Push bar to open” or a pictogram should be provided on the inside face of the door
immediately above the horizontal bar, or on the bar if it has a sufficient flat face to take the size of lettering
4. Care should be taken to ensure that any seals or weather stripping fitted to the complete door assembly, required. The surface area of the pictogram should be not less than 8,000mm2 and its colours should be
does not inhibit the correct operations of the panic exit device. white on a green background. It should be designed such that the arrow points to the operating element,
5. On double doorsets with rebated meeting stiles and where both leaves are fitted with panic exit devices, when installed. The pictogram given in Figure A.1 can be used.
it is essential to check that either leaf will open when its panic exit device is activated and also that both
leaves will open freely when both panic exit devices are operated simultaneously. The use of a carry bar to
move the active leaf may be required for this application.
6. Where panic exit devices are manufactured in more than one size it is important that the correct size is
selected.
7. Category 2 (standard projection) panic exit devices should be used in situations where there is restricted Figure A.1 – Pictogram
width for escape, or where the doors to be fitted with the panic exit devices are not able to open beyond Maintenance instructions.
90°.
The following shall be the minimum information to accompany the product:
8. Where a panic exit device is designed to be fitted to a glazed door, it is essential that the glazing is
To ensure performance in accordance with this document, the following routine maintenance checks should
tem¬pered or laminated glass.
be undertaken at intervals of not more than one month (or the period recommended by the producer):
9. Different fixing may be necessary for fitting panic exit devices to wood, metal or frameless glass doors. For
a) Inspect and operate the panic exit device to ensure that all components are in a satisfactory working
more secure fixing, male and female through-door bolts can be used.
condi¬tion; using a force gauge, measure and record the operating forces to release the exit device.
10. Panic exit devices are not intended for use on double action (double swing) doors unless specifically
b) Ensure that the keeper(s) is (are) free from obstruction.
de¬signed by the producer.
c) Check that the panic exit device is lubricated in accordance with the producer’s instructions.
11. The fixing instructions should be carefully followed during installation. These instructions and any
main¬tenance instructions should be passed on by the installer to the user. See Annex C. d) Check that no additional locking devices have been added to the door since its original installation.
12. The horizontal bar should normally be installed at a height of between 900mm and 1,100mm from the e) Check periodically that all components of the system are still correct in accordance with the list of approved
finished floor level, when the door is in the secured position. Where it is known that the majority of the components originally supplied with the system.
occupants of the premises will be young children, consideration should be given to reducing the height of f) Check periodically that the operating element is correctly tightened and, using a force gauge, measure the
the bar. operating forces to release the exit device. Check that the operating forces have not changed significantly
13. The horizontal bar should be installed so as to provide the maximum effective length. from the operating forces recorded when originally installed.

7
FLUID - Panic Exit Device

N01-1002
Maintenance after 20,000 cycles
1 300 mm maxi

2 500 mm maxi

200 kg maxi

The safety features of this product are essential to its compliance with
EN1125. No modification of any kind, other than those described in these
instructions, is permitted.

Warning failure to observe these fitting instructions will


! result in loss of warranty

ASSA ABLOY Australia Pty Limited ABN 90 086 451 907 ©2016_AAA-BRO-000_V1

Disclaimer ASSA ABLOY Australia Pty Ltd


Whilst every effort has been made to ensure that the information contained in this manual is accurate at the time of publication, ASSA ABLOY Australia 235 Huntingdale Road
Pty Limited (“ASSA ABLOY”) recommends that you consult ASSA ABLOY or its agents prior to placing an order to ascertain current information on specific Oakleigh, Victoria, 3166
products, as ASSA ABLOY reserves the right to make changes without notice. ASSA ABLOY will not be liable for any injury, loss or damage whatsoever, Australia
FE100-121

arising from any errors or omissions in the information contained in the manual or arising from the use or application of the information contained herein.
© 2015 copyright by ASSA ABLOY All rights reserved 1300 LOCK UP (1300 562 587)
lockweb.com.au